Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Kokot, J." wg kryterium: Autor


Tytuł:
Abundance and diversity of fungi in oak wood
Autorzy:
Behnke-Borowczyk, J.
Kwasna, H.
Kokot, K.
Haluszczak, M.
Lakomy, P.
Powiązania:
https://bibliotekanauki.pl/articles/2077912.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Instytut Dendrologii PAN
Tematy:
abundance
deadwood
diversity
fungi
ITS
Illumina
oak
Opis:
Deadwood is an important functional and structural component of forest ecosystems since it regulates nutrient cycling, serves as a carbon (C) pool, increases the C content in the soil, and is a source of resources, including water, for a wide range of saproxylic and non-saproxylic organisms. The abundance and diversity of wood-inhabiting fungi in six fallen, horizontally lying logs of Quercus petraea, in the 1st, 2nd and 3rd decay classes, in the Drawa National Park in Poland in 2015, were studied using the Illumina se- quencing technique. The total number of OTUs obtained (264 307) included sequences of culturable fungi (242 369 = 91.70%) and non-culturable fungi (7 056 = 2.66%). The dead oak wood was colonized by 277 taxa. Culturable fungi of Zygomycota, Ascomycota and Basidiomycota comprised 75% of taxa detected and were represented by 14, 139 and 53 taxa respectively. Non-culturable organisms were represented by 70 taxa. Fungi were classified into 18 groups: (i) typical soft rot fungi, (ii) phytopathogens potentially hazard- ous to trees, (iii) epiphytes and endophytes or weak, opportunistic pathogens, (iv) ectomycorrhizal species, (v) ericoid mycorrhizal species, (vi) crust fungi, (vii) resupinate basidiomycetes, (viii) saprotrophs and soil fungi, (ix) opportunistic human pathogens causing superficial or systemic mycoses, (x) pathogens of warm- or cold-blooded animals, (xi) ascomycetous yeasts, (xii) basidiomycetous yeasts, (xiii) antagonists of fungi, (xiv) producers of metabolites effective against pathogens, (xv) hyperparasites, (xvi) lichen-form- ing species, (xvii) partners of other fungi, (xviii) species rare or uncommon in nature. It was shown that: (i) coarse, woody debris of oak is host to abundant and diverse mycobiota, (ii) abundance and diversity of fungi increase with the decay continuum, (iii) oak logs can be a habitat of phytopathogens potentially haz- ardous to forest health, (iv) different phytopathogens favour wood in different decay classes, (v) abundance of pathogens decreases, and of ericoid mycorrhizal (or soil) species increases with the decay continuum. Maintaining different types of deadwood increases fungal diversity, but also the risk of diseases.
Źródło:
Dendrobiology; 2018, 80; 143-160
1641-1307
Pojawia się w:
Dendrobiology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An evaluation of the phytotoxicity of filter backwash water coagulation products from a pool water system
Autorzy:
Łaskawiec, E.
Dudziak, M.
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/207079.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
phytotptpxicity
swimming pool water
coagulation process
Lepidium sativum
Lemna minor
fitotoksyczność
woda basenowa
proces koagulacji
Opis:
The possibility of using the process of coagulation for purifying the filter backwash water from a swimming pool water system has been presented. The assessment of the process efficiency based on the physicochemical parameters was extended by a phytotoxicity analysis of products (sludges and supernatant liquids) obtained from the coagulation processes. The phytotoxicity of sludges was examined with respect to garden cress (Lepidium sativum) and white mustard (Sinapis alba), while duckweed (Lemna minor) was used for studying liquids. Coagulation process was highly effective in purifying backwash water when the lowest of the studied aluminum coagulant doses (from 7 to 20 mg/dm3) was used. Moreover, the phytotoxicity assessment of backwash water allowed the determination of the hazard toward plants, which would be posed by using the backwash water for plant irrigation. The high stimulation of the growth of plant indices, observed in samples with raw backwash water, was caused by nutritive nitrogen and phosphorus. Their removal, in the case of postcoagulation solutions, significantly contributed to the inhibition of plant growth. In turn, sludges derived from both raw washings and coagulation exhibited phytotoxicity.
Źródło:
Environment Protection Engineering; 2018, 44, 4; 43-56
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bacterial ACC Deaminase Activity in Promoting Plant Growth on Areas Contaminated with Heavy Metals
Autorzy:
Grobelak, A.
Kokot, P.
Świątek, J.
Jaskulak, M.
Rorat, A.
Powiązania:
https://bibliotekanauki.pl/articles/124256.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
ACC deaminase
endophytes
heavy metals
plant growth promoting bacteria
PGPB
Opis:
The objective of this study was to explore the possible improvement of plant growth using the activity of the bacterial enzyme ACC (1-aminocyclopropane-1-carboxylate) deaminase (endophytes and rhizobacteria). The beneficial effect of ACC deaminase activity was tested on the plants growing under stress conditions (high concentrations of heavy metals: cadmium, lead, zinc in the soil). The bacteria were isolated from three plants species: Festuca rubra L., Agrostis capillaris L., Arabidopsis thaliana L. Heynh, acquired from the area contaminated with heavy metals. The strains with the highest ACC deaminase activity were used to prepare a bacterial consortium and inoculate the plants. It has been shown that inoculation of plants with ACC producing bacteria has a positive effect on their growth under stress conditions. The bacterial entophytes strains showed a higher activity of ACC deaminase, which resulted in a higher biomass growth of inoculated plants. The PGPB bacteria may limit the toxicity of harmful ions and thus the increase the adaptive properties of plants. Moreover, it was discovered that the bacteria mainly belonging to genus Bacillus and Pseudomonas had the highest ACC deaminase activity in the environment contaminated with multiple heavy metals. The use of selected microorganisms and plants will provide results in an increasing efficiency of phytoremediation.
Źródło:
Journal of Ecological Engineering; 2018, 19, 5; 150-157
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dobór warunków odzysku wody ze strumienia popłuczyn z instalacji wody basenowej
Selection of conditions of water recovery from the stream of washings from the swimming pool water system
Autorzy:
Łaskawiec, E.
Dudziak, M.
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/125768.pdf
Data publikacji:
2018
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
proces zintegrowany
popłuczyny
nanofiltracja
koagulacja
instalacja wody basenowej
integrated process
washings nanofiltration
coagulation
swimming pool water installation
Opis:
Przedstawiono wyniki badań dotyczących zastosowania zintegrowanego procesu: koagulacja-sedymentacja-nanofiltracja do oczyszczania popłuczyn z obiegu uzdatniania wody basenowej. Badania obejmowały ocenę wpływu warunków prowadzenia procesów wstępnych, tj. koagulacji (zakres dawek koagulantu 1,5-3,0 mg Al/dm3) oraz sedymentacji (przy czasie trwania 0,5-24 h) na własności transportowo-separacyjne membran nanofiltracyjnych. Porównawczo przeprowadzono proces nanofiltracji surowych popłuczyn. Obserwowano wyższą wartość objętościowego strumienia permeatu w trakcie procesu nanofiltracji dla popłuczyn po koagulacji (dawka koagulantu 1,5 mg Al/dm3). Stwierdzono znaczącą poprawę zdolności transportowych membrany wraz z wydłużeniem czasu sedymentacji (do 24 h). Cząsteczki osadów, które przyczyniały się do obniżenia wydajności filtracji popłuczyn po koagulacji, przy wyższej dawce koagulantu (3,0 mg Al/dm3), równocześnie spowodowały stopniowy wzrost zdolności separacyjnych membrany i utworzenie tzw. membrany wtórnej. Przy czym charakteryzowała się ona mniejszą porowatością niż membrana pierwotna. W badanym przypadku zastosowanie układu zintegrowanego pozwoliło na poprawę warunków transportowych membran nanofiltracyjnych, zmniejszenie stężenia glinu pozostałego oraz znaczną poprawę pozostałych parametrów fizykochemicznych (m.in. zmniejszenie ilości zawiesin ogólnych i obniżenie absorbancji w nadfiolecie UV254).
This study discusses the results of the preliminary tests use an integrated process coagulationsedimentationnanofiltration for the purification washings from swimming pool water treatment circulation. Studies included the effect of the terms and conditions of the preparatory process (coagulation where range of doses of coagulant 1.5-3.0 mg Al/dm3 and sedimentation where the scope of duration 0.5-24 h) on the transport and separating properties nanofiltration membranes. Comparatively, the process of nanofiltration of raw washings has been performed. A higher value of volumetric permeate flux was observed during the nanofiltration process for washings after coagulation process with dose 1.5 mg Al/dm3. There has also been significant improvement in transport capacity of the membrane with increased sedimentation time (to 24 hours). The presence of sediment molecules, which contributed to the reduction of the process efficiency during filtration of washings after Edyta Łaskawiec, Mariusz Dudziak i Joanna 184 Wyczarska-Kokot coagulation with dose 3.0 mg Al/dm3, at the same time they caused a gradual increase in membrane separation capacity. A secondary membrane having a lower porosity than the primary membrane has been produced. The use of the integrated system has improved the transport conditions of the nanofiltration membranes, reduction of residual aluminium concentration, as well as significant improvements in other physicochemical parameters (inter alia reduction the amount of suspended solids and ultraviolet absorbance UV254).
Źródło:
Proceedings of ECOpole; 2018, 12, 1; 177-184
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena możliwości recyklingu popłuczyn z systemu oczyszczania wody basenowej
Evaluation of the recycling possibility of washings from swimming poool water treatment system
Autorzy:
Łaskawiec, E.
Dudziak, M.
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/126852.pdf
Data publikacji:
2018
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
wody basenowe
popłuczyny
ocena toksykologiczna
analiza fizykochemiczna
biotest
swimming pool water
back washing water
toxicological assessment
physicochemical analysis
Opis:
Przedstawiono ocenę fizykochemiczną oraz toksykologiczną próbek popłuczyn surowych (pobranych bezpośrednio po procesie płukania złóż filtracyjnych) po procesie napowietrzania oraz procesie dechloracji. Popłuczyny pobrano z obiegów basenowych dwóch krytych pływalni. Przeprowadzono badania wstępne i zasadnicze, w których popłuczyny charakteryzowały się zróżnicowanymi parametrami fizykochemicznymi. Do oceny toksykologicznej zastosowano test inhibicji bioluminescencji Mictorox®, test przeżywalności larw owadów Chaoborus sp. oraz fitotest z wykorzystaniem rzęsy drobnej Lemna minor. Badania wstępne obejmowały charakterystykę ekotoksykologiczną popłuczyn poddanych procesom napowietrzania oraz dechloracji. W badaniach zasadniczych analizowano wpływ czasu napowietrzania na jakość popłuczyn. Wyniki badań wstępnych wskazywały, że popłuczyny surowe, jak również po 30-minutowym napowietrzaniu nie mogły być bezpośrednio odprowadzone do środowiska naturalnego ze względu na wysoką toksyczność w stosunku do organizmów żywych. Zastosowanie dłuższego czasu napowietrzania (160 minut) przyczyniło się do znacznej poprawy jakości popłuczyn i eliminacji ich właściwości toksycznych w stosunku do organizmów wskaźnikowych. Zróżnicowane efekty uzyskano po procesie chemicznej dechloracji. Odnotowano stymulację bioluminescencji bakterii (testu Microtox®), ale równocześnie zaobserwowano śmierć pojedynczych osobników larw owadów. Pomimo wysokiego przyrostu biomasy w teście z Lemna minor, zaobserwowano stopniowe odbarwienie frondów pod wpływem popłuczyn. Ze względu na zmienność jakości popłuczyn, obecność w nich ubocznych produktów dezynfekcji i koagulacji oraz toksyczne oddziaływanie na organizmy niezbędne jest rozszerzenie badań w zakresie metod umożliwiających ich recykling.
This study discusses the physical and chemical analysis as well as toxicological evaluation of backwashings samples collected after rising raw filter beds, following aeration and dechlorination process. The tested washings were collected at facilities located in two indoor swimming pools. Toxicological evaluation included Mictorox® bioluminescence inhibition assay, Chaoborus sp. larvae survivability test as well as Lemna minor duckweed fito test. The initial stage of the research was focused on eco-toxicological properties of backwashings, subject to aeration and dechlorination processes. The main stage of the research involved additional analysis of the impact of aeration duration on the quality of washings in terms of physical and chemical parameters. The results of the initial stage clearly suggest that both raw washings as well as washings after 30 minutes of aeration are not suitable for direct disposal in the environment due to biohazards resulting from high toxicity of washings. On the other hand extension of the aeration process (160 minutes) contributed to significant improvement of washings quality and removal of toxic properties in relation to the indicator species used in the research. Chemical dechlorination ended with varying results. Microtox® bioluminescence assay resulted in bacteria bioluminescence with simultaneous observation of death of individual larvae. Despite high increase of biomass in Lemna minor test, some gradual decolouration of shoots as the result of washings used. In further solutions for recycling must be sought which will provide reduced water consumption and sewage.
Źródło:
Proceedings of ECOpole; 2018, 12, 1; 185-193
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena skuteczności procesu koagulacji w oczyszczaniu popłuczyn z układu cyrkulacji wody basenowej
Evaluation of coagulation process effectiveness in purification of filter washings from swimming pool circulation system
Autorzy:
Łaskawiec, E.
Dudziak, M.
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/236975.pdf
Data publikacji:
2018
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
woda basenowa
popłuczyny z filtrów
oczyszczanie
fitotoksyczność
koagulacja
sole glinu
sole żelaza
rzęsa wodna
rzeżucha
swimming pool water
backwash water
purification
phytotoxicity
coagulation
aluminium salts
iron salts
Lemna minor
Lepidium sativum
Opis:
Oceniono możliwości zastosowania procesu koagulacji do oczyszczania popłuczyn z płukania złóż filtracyjnych pracujących w układzie cyrkulacji wody basenowej. Usunięcie części zanieczyszczeń z popłuczyn pozwoliłoby na ich odprowadzanie bezpośrednio do środowiska (np. do nawadniania zieleni) oraz na ograniczenie ilości ścieków odprowadzanych do kanalizacji. W badaniach laboratoryjnych zastosowano cztery różne koagulanty – glinowe (PAX) i żelazowe (PIX) – w zakresie dawek od 1,5 mg/dm3 do 6,0 mg/dm3. Analizie zmian wartości wybranych wskaźników fizyczno-chemicznych (barwa, zawiesiny ogólne, mętność, chlor ogólny, fosfor ogólny, absorbancja w nadfiolecie, ChZT oraz wskaźnik fenolowy) towarzyszyła także analiza fitotoksyczności składników popłuczyn (cieczy nadosadowej i osadów) w stosunku do wybranych roślin wskaźnikowych – rzęsa (Lemna minor) i rzeżucha (Lepidium sativum). Przeprowadzone testy naczyniowe procesu koagulacji pozwoliły na uzyskanie jakości popłuczyn pozwalającej na wprowadzenie ich bezpośrednio do środowiska. Niezależnie od zastosowanego rodzaju koagulantu, poprawa jakości fizyczno-chemicznej popłuczyn została osiągnięta już przy dawkach w zakresie 1,5÷3,0 mg/dm3, przy czym najskuteczniejszy okazał się PAX 25, będący mieszaniną polichlorku glinu i chlorku żelaza(II). Dodatkowo nie odnotowano efektu fitotoksycznego zarówno cieczy nadosadowej, jak i osadów pokoagulacyjnych. Tak oczyszczone popłuczyny mogą być wykorzystane na przykład do nawadniania zieleni na terenach obiektów basenowych.
Applicability of coagulation technique in purification of filter washings from the swimming pool circulation system was evaluated. Removal of some of the contaminants from washings would allow for their discharge directly into the environment (e.g., for irrigation of greenery) and limiting the amount of sewage entering the sewer. In the laboratory studies, four different coagulants were used – aluminum (PAX) and ferric (PIX) – in doses ranging 1.5–6.0 mg/dm3. In addition, the analysis of fluctuations of the values of selected physicochemical parameters (color, general suspensions, turbidity, total chlorine, total phosphorus, ultraviolet absorbance, COD and phenol index) was accompanied by the analysis of washing components (supernatant liquid and sediments) phytotoxicity against the selected indicator plants – eyelash (Lemna minor) and cress (Lepidium sativum). The jar tests conducted throughout the coagulation process resulted in washings of quality adequate to be introduced directly into the environment. Regardless of the type of coagulant used, the improvement of physicochemical parameters of washings was achieved already at doses in the range of 1.5–3.0 mg/dm3, with PAX 25, polyaluminum chloride and iron chloride(II) mixture, being the most effective. In addition, no phytotoxic effect of both the supernatant and post-coagulation sediments was noted. Such purified washings could be employed for example in watering greenery at swimming pool areas.
Źródło:
Ochrona Środowiska; 2018, 40, 1; 57-60
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of the filtration bed type in the pool water treatment system on washings quality
Wpływ rodzaju złoża filtracyjnego w układach oczyszczania wody basenowej na jakość popłuczyn
Autorzy:
Wyczarska-Kokot, J.
Lempart, A.
Powiązania:
https://bibliotekanauki.pl/articles/126751.pdf
Data publikacji:
2018
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
filter beds
washings
swimming pool
sedimentation
złoża filtracyjne
popłuczyny
basen
sedymentacja
Opis:
This paper presents the influence of the type of filtration beds, used in swimming pool water treatment systems, on the quality and possibility of reusing the washings. The research covered 4 pool cycles with sand, sand and anthracite, glass and diatomaceous beds. The degree of contamination of washings was assessed on the basis of physical, chemical and bacteriological tests. The possibility of drainage of washings into the natural environment was considered, and the results of the research were compared with the permissible values of pollution indicators for wastewater discharged to water or ground. A direct management of the washings from the analyzed filters proved impossible mainly due to the high content of TSS (total suspended solids) and free chlorine. The washings were sedimented and then the supernatant was stirred intensively. As a result of these processes, the quality of washings was significantly improved. This allowed planning to supplement the pool water installations with systems for washings management.
Przedstawiono wpływ rodzaju złóż filtracyjnych, stanowiących wypełnienie filtrów w układach oczyszczania wody basenowej, na jakość i możliwość zagospodarowania popłuczyn. Badaniami objęto 4 obiegi basenowe, w których zastosowano złoża: piaskowe, piaskowo-antracytowe, szklane oraz okrzemkowe. Stopień zanieczyszczenia popłuczyn oceniono na podstawie badań fizyczno-chemicznych i bakteriologicznych próbek popłuczyn. Rozważono możliwość odprowadzania popłuczyn do środowiska naturalnego, a wyniki badań porównano z dopuszczalnymi wartościami wskaźników zanieczyszczeń dla ścieków odprowadzanych do wód lub ziemi. Bezpośrednie zagospodarowanie popłuczyn z analizowanych filtrów okazało się niemożliwe przede wszystkim ze względu na duże zawartości zawiesin ogólnych oraz chloru wolnego. Z tego względu popłuczyny poddano sedymentacji, a wodę nadosadową intensywnemu mieszaniu. W wyniku tych procesów jakość popłuczyn uległa znacznej poprawie. Pozwoliło to planować uzupełnianie instalacji wody basenowej o układy zagospodarowania popłuczyn.
Źródło:
Proceedings of ECOpole; 2018, 12, 2; 355-361
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ultrafiltration for Purification and Treatment of Water Streams in Swimming Pool Circuits
Autorzy:
Łaskawiec, E.
Dudziak, M.
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/125442.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
swimming pool water
pressure driven
membrane processes
closed circuit
water systems
water treatment systems
water recovery
Opis:
The paper presents possible applications of pressure-driven membrane processes for treatment of swimming pool water and purification of waste streams – washings. Newly identified swimming pool water quality issues are presented that require a modernization of existing technologies. The studies used polymer membranes with the same particle distribution range (50000 Da), but made of different membrane-forming materials: polyvinylidene difluoride (PVDF) and polyether sulfone (PES) for purification of washings. The ultrafiltration process allowed obtaining a high turbidity reduction rate in washings (over 95%), and also a significant reduction of total organic carbon. The effectiveness of the PES membrane was reduced after the process commencement, whereas the separation capacity of the PVDF membrane increased during the studied filtration process. While setting the operational process parameters consideration should be given also to the resistance of used membranes to chlorine present in the swimming pool water. A prolonged exposure of the polyether sulfone membrane to chloride may have caused its gradual damage and degradation of its separation properties.
Źródło:
Journal of Ecological Engineering; 2018, 19, 3; 38-44
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zawartość chloru w różnych punktach niecki basenowej - analiza ryzyka dla zdrowia kąpiących się
Chlorine contamination in different points of pool - risk analysis for bathers’ health
Autorzy:
Wyczarska-Kokot, J.
Lempart, A.
Dudziak, M.
Powiązania:
https://bibliotekanauki.pl/articles/127220.pdf
Data publikacji:
2018
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
mapa chloru
system hydrauliczny basenu
zagrożenie zdrowia kąpiących się
map of chlorine
pool hydraulic system
risk to bathers’ health
Opis:
Stacja oczyszczania i dezynfekcji wody basenowej spełnia swoje zadanie pod warunkiem współpracy systemu hydraulicznego z odpowiednią geometrią niecki basenowej. Przepływ wody przez nieckę basenu może powodować powstawanie „martwych” stref niebiorących udziału w cyrkulacji. W strefach tych różny może być stopień wymieszania dezynfektanta z wodą. Tym samym różna może być skuteczność dezaktywacji mikroorganizmów i wpływ na zdrowie osób kąpiących się. Przedstawiono wyniki fizyczno-chemicznych badań próbek wody basenowej pobranych z charakterystycznych punktów niecki. Szczególną uwagę zwrócono na zawartość chloru wolnego i chloru związanego. Badania przeprowadzono w dwóch krytych basenach różniących się systemem przepływu wody. Na podstawie wyników analiz sporządzono mapy chloru dla niecek basenowych. Wykazano, że dla oceny ryzyka zagrożenia zdrowia osób kąpiących się próbki wody powinny być pobierane z punktów niecki basenowej uznanych za reprezentatywne.
The pool water treatment and disinfection plant fulfills its task, if the hydraulic system cooperates with the appropriate pool basin geometry. Water flow through the pool can cause “dead” zones not involved in circulation. In these zones the degree of mixing the disinfectant with water can be different. In consequence, the effectiveness of microorganisms’ deactivation and the health effects of bathers may be different. The physicochemical results of pool water samples taken from the characteristic points of the basin were presented. Attention has been paid to the content of free chlorine and combined chlorine. The study was conducted in two indoor pools, differing in water flow. Based on the analysis results, chlorine maps for swimming pools were prepared. It has been shown that in order to assess the health risk to bathers samples of water should be collected from representative points of pool.
Źródło:
Proceedings of ECOpole; 2018, 12, 1; 275-283
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Alergia na jad pszczeli u pszczelarzy
Bee venom allergy in beekeepers
Autorzy:
Matysiak, Joanna
Kokot, Zenon J.
Matysiak, Jan
Powiązania:
https://bibliotekanauki.pl/articles/1034507.pdf
Data publikacji:
2017
Wydawca:
Oficyna Wydawnicza Mediton
Tematy:
jad pszczeli
pszczelarze
reakcje alergiczne
użądlenie
Opis:
Beekeepers are a particular group of people highly exposed to stings and allergy to bee venom due to the nature of their work. Positive skin test results or bee venom specific IgE are observed in up to 60% of beekeepers. Reaction to the bee sting occurs most often as a normal local reaction, but a person allergic to bee venom may experience large local reaction, systemic symptoms, including anaphylactic shock. In patients with confirmed systemic allergic reaction in the past, basic diagnostic tests such as skin tests and bee venom specific IgE must be performed. Where appropriate, additional tests such as component- -resolved diagnosis, cell-based assays, tryptase or the venom-specific IgG4 levels should be conducted. Studies have shown significantly higher tryptase and specific IgG4 levels in beekeepers. Moreover, a correlation between clinical symptoms after the sting and the phospholipase A2 specific IgE concentration was observed. During venom-specific immunotherapy, increasing the dose to 200 µg should be considered in beekeepers.
Pszczelarze są szczególną grupą osób najbardziej narażonych na użą- dlenia i alergię na jad pszczeli z racji wykonywanej pracy. Dodatnie wyniki testów skórnych lub obecność swoistych dla jadu pszczelego IgE obserwowane są nawet u 60% badanych pszczelarzy. Reakcja po użądleniu przez pszczołę najczęściej występuje pod postacią normalnej reakcji miejscowej, ale u osoby uczulonej na jad pszczeli może wystą- pić nasilona reakcja miejscowa lub objawy ogólne, do wstrząsu anafilaktycznego włącznie. U pacjentów z reakcją systemową w wywiadzie należy wykonać podstawowe badania diagnostyczne: testy skórne i oznaczenia swoistych dla jadu sIgE, a w uzasadnionych przypadkach badania dodatkowe, takie jak: oznaczenia sIgE dla poszczególnych alergenów jadu pszczelego (diagnostyka komponentowa), testy komórkowe, oznaczanie poziomu tryptazy czy stężenia swoistych dla jadu IgG4. Badania przeprowadzone u pszczelarzy wykazały istotnie wyższe stę- żenia tryptazy oraz swoistych IgG4 w tej grupie zawodowej. Ponadto zaobserwowano korelację nasilenia objawów klinicznych po użądleniu ze stężeniem sIgE dla fosfolipazy A2 . Podejmując decyzję o prowadzeniu swoistej immunterapii jadem pszczelim u pszczelarza należy rozważyć zwiększenie dawki podtrzymującej do 200 µg.
Źródło:
Alergia Astma Immunologia - przegląd kliniczny; 2017, 22, 1; 5-11
1427-3101
Pojawia się w:
Alergia Astma Immunologia - przegląd kliniczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza możliwości zrzutu popłuczyn z obiektu basenowego do rzeki
Analysis of the possibility of washings discharge from the swimming pool to the river
Autorzy:
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/127336.pdf
Data publikacji:
2017
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
basen
popłuczyny
klasa czystości rzeki
sedymentacja
koagulacja
swimming pool
washings
cleanliness class of river
sedimentation
coagulation
Opis:
W pracy przedstawiono wyniki badań, na podstawie których określono możliwość odprowadzenia popłuczyn, powstałych w wyniku płukania złóż filtracyjnych w systemie oczyszczania wody basenowej, do pobliskiej rzeki. Na podstawie analiz fizyczno-chemicznych próbek popłuczyn określono stopień ich zanieczyszczenia. Wyniki badań porównano z zaleceniami dotyczącymi dopuszczalnego stopnia zanieczyszczeń w ściekach odprowadzanych do wód lub ziemi (DzU 2014, poz. 1800) i wymaganiami pozwolenia wodnoprawnego wydanymi dla analizowanego obiektu basenowego. Analiza wyników badań popłuczyn surowych (niepoddanych obróbce) wykazała, że bezpośrednie ich odprowadzenie do rzeki jest niemożliwe przede wszystkim ze względu na duże stężenie chloru wolnego oraz ilość zawiesin ogólnych. Analiza wyników badań popłuczyn poddanych procesowi sedymentacji lub koagulacji objętościowej w warunkach laboratoryjnych pozwoliła zaprojektować system odprowadzenia wody nadosadowej do rzeki. Warunkiem „zrzutu” wody nadosadowej do rzeki będzie konieczność zastosowania zbiornika buforowego, osadnika lub systemu wspomagającego sedymentację zawiesin w popłuczynach np. poprzez zastosowanie koagulacji objętościowej, a następnie odprowadzanie zagęszczonych ścieków do kanalizacji sanitarnej.
The paper presents the results of studies on determining of the possibility of discharge washings, as a result of rinse filter beds in the swimming pool water treatment system, to the river. Based on the physical and chemical analysis of washings samples the degree of their contamination was determined. The results were compared with the recommended acceptable level of pollutants in wastewater discharged to water or soil (OJ 2014, item 1800) and with the requirements of the water permit issued for the analyzed swimming pool. The obtained results for raw washings (untreated) showed that direct discharge of washings into the near located river is impossible, especially due to the high concentration of free chlorine and the amount of total suspended solids (TSS). Analysis of the results of washings subjected to the process of sedimentation or coagulation in the laboratory helped design the system supernatant water drain into the river. The condition of such management would be to use a buffer tank, settling tank or supporting system to sedimentation of suspended solids, e.g. the use of coagulation and then the draining of concentrated sewage into the sanitary sewage system.
Źródło:
Proceedings of ECOpole; 2017, 11, 1; 325-331
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania jakości popłuczyn ze stacji filtrów w obiekcie basenowym w aspekcie możliwości odprowadzania ich do wód lub do ziemi – studium przypadku
Studies of backwash water quality from a swimming pool filter plant in terms of their discharge to surface water bodies or into the ground – a case study
Autorzy:
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/237337.pdf
Data publikacji:
2017
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
swimming pool
backwashing
filter washings
backwash water
sedimentation
coagulation
discharge into a river
draining into the ground
basen
płukanie złóż filtracyjnych
wody popłuczne
popłuczyny
sedymentacja
koagulacja
odprowadzanie do rzeki
rozsączanie w gruncie
Opis:
Results of research on physico-chemical and bacteriological quality of effluents from backwashing of filter beds were presented for water treatment system of a selected swimming pool (waterpark). The aim of these studies was to evaluate potential to discharge the backwash water from rapid filter beds to a river or to drain them into the ground. Based on the physico-chemical and microbiological analysis of backwash water samples, degree of their contamination was determined with regard to the current quality requirements for wastewater discharged into surface water or soil as well as the requirements under the Water Law Act that defined water quality to be discharged from the analyzed pool. It was demonstrated that direct routing of the eluate from backwashing into the river or soil was impossible due to a high amount of total suspended solids and chlorine content. The concurrent efficacy testing of sedimentation and alum coagulation of backwash water performed under laboratory conditions demonstrated that the obtained supernatant water complied with the requirements and might be discharged into the river or drained into the ground.
Przedstawiono wyniki badań jakości fizyczno-chemicznej i bakteriologicznej popłuczyn powstających w wyniku płukania złóż filtracyjnych w układzie oczyszczania wody w wybranym obiekcie basenowym (park wodny). Celem badań było określenie możliwości odprowadzania popłuczyn z filtrów pospiesznych do rzeki lub ich rozsączania w gruncie. Na podstawie wyników analiz fizyczno-chemicznych i mikrobiologicznych próbek popłuczyn określono stopień ich zanieczyszczenia w odniesieniu do wymagań dotyczących jakości ścieków odprowadzanych do wód lub do ziemi obowiązujących w Polsce oraz wymagań zawartych w pozwoleniu wodnoprawnym, które określa wymaganą jakość wód odprowadzanych z analizowanego obiektu basenowego. Wykazano, że bezpośrednie odprowadzanie popłuczyn z płukania filtrów do rzeki lub ziemi jest niemożliwe, ze względu na dużą ilość zawiesin ogólnych oraz zawartość chloru w popłuczynach. Jednocześnie przeprowadzone w warunkach laboratoryjnych badania skuteczności procesów sedymentacji i koagulacji objętościowej popłuczyn koagulantem glinowym wykazały, że uzyskane w ten sposób wody nadosadowe spełniają warunki odprowadzania ich do rzeki lub rozsączania w gruncie.
Źródło:
Ochrona Środowiska; 2017, 39, 2; 45-50
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Chlorine contamination in different points of pool – risk analysis for bathers’ health
Zawartość chloru w różnych punktach niecki basenowej – analiza ryzyka dla zdrowia kąpiących się
Autorzy:
Wyczarska-Kokot, J.
Lempart, A.
Dudziak, M.
Powiązania:
https://bibliotekanauki.pl/articles/388266.pdf
Data publikacji:
2017
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
map of chlorine
pool hydraulic system
risk to bathers’ health
mapa chloru
system hydrauliczny basenu
zagrożenie zdrowia kąpiących się
Opis:
The pool water treatment and disinfection plant fulfills its task only if the hydraulic system cooperates with the appropriate pool basin geometry. Water flow through the pool can cause “dead” zones not involved in circulation. In these zones the degree of mixing the disinfectant with water can be different. In consequence, the effectiveness of microorganisms’ deactivation and the health effects on bathers may be different. The physicochemical results of pool water samples taken from the characteristic points of the basin were presented. Attention has been paid to the content of free chlorine and combined chlorine. The study was conducted in two indoor pools, differing in water flow system. Based on the analysis results, chlorine maps for swimming pools were prepared. It has been shown that in order to assess the health risk to bathers samples of water should be collected from representative points of the pool.
Stacja oczyszczania i dezynfekcji wody basenowej spełnia swoje zadanie pod warunkiem współpracy systemu hydraulicznego z odpowiednią geometrią niecki basenowej. Przepływ wody przez nieckę basenu może powodować powstawanie „martwych” stref niebiorących udziału w cyrkulacji. W strefach tych różny może być stopień wymieszania dezynfektanta z wodą. Tym samym różna może być skuteczność dezaktywacji mikroorganizmów i wpływ na zdrowie osób kąpiących się. Przedstawiono wyniki fizyczno-chemicznych badań próbek wody basenowej pobranych z charakterystycznych punktów niecki. Szczególną uwagę zwrócono na zawartość chloru wolnego i chloru związanego. Badania przeprowadzono w dwóch krytych basenach różniących się systemem przepływu wody. Na podstawie wyników analiz sporządzono mapy chloru dla niecek basenowych. Wykazano, że do oceny ryzyka zagrożenia zdrowia osób kąpiących się próbki wody powinny być pobierane z punktów niecki basenowej uznanych za reprezentatywne.
Źródło:
Ecological Chemistry and Engineering. A; 2017, 24, 2; 217-226
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selection of conditions of water recovery from the stream of washings from the swimming pool water system
Dobór warunków odzysku wody ze strumienia popłuczyn z instalacji wody basenowej
Autorzy:
Łaskawiec, E.
Dudziak, M.
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/387996.pdf
Data publikacji:
2017
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
integrated process
washings nanofiltration
coagulation
sedimentation
swimming pool water
Installation
proces zintegrowany
popłuczyny
nanofiltracja
koagulacja
instalacja wody basenowej
Opis:
This study discusses the results of the preliminary tests use an integrated process coagulationsedimentationnanofiltration for the purification washings from swimming pool water treatment circulation. Studies included the effect of the terms and conditions of the preparatory process (coagulation where range of doses of coagulant 1.5–3.0 mgAl/dm3 and sedimentation where the scope of duration 0.5–24 h) on the transport and separating properties nanofiltration membranes. Comparatively, the process of nanofiltration of raw washings has been performed. DK GE Osmonics membrane was used as a nanofiltration membrane. A higher value of volumetric permeate flux was observed during the nanofiltration process for washings after coagulation process with dose 1.5 mgAl/dm3. There has also been significant improvement in transport capacity of the membrane with increased sedimentation time (to 24 hours). The presence of sediment molecules, which contributed to the reduction of the process efficiency during filtration of washings after coagulation with dose 3.0 mgAl/dm3, at the same time they caused a gradual increase in membrane separation capacity. A secondary membrane having a lower porosity than the primary membrane has been produced. The use of the integrated system has improved the transport conditions of the nanofiltration membranes, reduction of residual aluminium concentration, as well as significant improvements in other physicochemical parameters (inter alia reduction the amount of suspended solids and ultraviolet absorbance UV254).
W pracy przedstawiono wyniki badań dotyczących zastosowania zintegrowanego procesu koagulacji–sedymentacji–nanofiltracji do oczyszczania popłuczyn z obiegu uzdatniania wody basenowej. Badania obejmowały ocenę wpływu warunków prowadzenia procesów wstępnych, tj. koagulacji (zakres dawek koagulantu 1,5–3,0 mgAl/dm3) oraz sedymentacji (czas trwania 0,5–24 h) na własności transportowo-separacyjne membran nanofiltracyjnych. Porównawczo przeprowadzono proces nanofiltracji surowych popłuczyn. Obserwowano wyższą wartość objętościowego strumienia permeatu w trakcie procesu nanofiltracji dla popłuczyn po koagulacji (dawka koagulantu 1,5 mgAl/dm3). Stwierdzono znaczącą poprawę zdolności transportowych membrany wraz z wydłużeniem czasu sedymentacji (do 24 h). Obecność cząsteczek osadów, które przyczyniały się do obniżenia wydajności filtracji popłuczyn po koagulacji, w której zastosowano wyższą dawkę koagulantu (3,0 mgAl/dm3), równocześnie spowodowała stopniowy wzrost zdolności separacyjnych membrany – utworzyła się tzw. membrana wtórna charakteryzująca się mniejszą porowatością niż membrana pierwotna. W badanym przypadku zastosowanie układu zintegrowanego pozwoliło na poprawę warunków transportowych membran nanofiltracyjnych, zmniejszenie stężenia glinu pozostałego oraz znaczną poprawę pozostałych parametrów fizykochemicznych (m.in. zmniejszenie ilości zawiesin ogólnych i obniżenie absorbancji w nadfiolecie UV254).
Źródło:
Ecological Chemistry and Engineering. A; 2017, 24, 2; 227-236
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The use of Membrane Techniques in Swimming Pool Water Treatment
Autorzy:
Łaskawiec, E.
Madej, M.
Dudziak, M.
Wyczarska-Kokot, J.
Powiązania:
https://bibliotekanauki.pl/articles/952481.pdf
Data publikacji:
2017
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
pressure membrane processes
ultrafiltration
nanofiltration
toxicological assessment
Opis:
The paper has determined the suitability of membrane processes (UF ultrafiltration, UF, and nanofiltration, NF) for the purification of waste streams, so-called backwash water, obtained from washing filtration beds in a swimming pool water system. The backwash water samples were taken from the circuits located in two indoor facilities with a different purpose of the basins. Moreover, the samples were characterized by varying quality, as described by selected physicochemical parameters (such as turbidity and ultraviolet absorbance UV254). Commercial membranes were used for the tests. The transport-separation properties of the membranes were determined based on the volumetric flux of the permeate. In addition, backwash water samples before and after the membrane process were subjected to toxicological assessment using the Microtox® screening test. The performed processes contributed to a significant reduction in turbidity and the value of UV254 ultraviolet absorbance, both in the ultrafiltration and nanofiltration processes. Whereas, significant differences in transport properties were noted within individual processes. A great influence of backwash water quality, including physicochemical parameters, on the course and results of the membrane filtration processes was demonstrated. In all of the nanofiltration cycles carried out, the removal of the toxic properties of the backwash water with respect to bacteria in the Microtox® test was found. Nevertheless, samples with high values of resultant physicochemical parameters after the ultrafiltration process were still characterized by high toxicity. Pressure membrane processes show high effectiveness in the removal of contaminants from backwash water. However, it is necessary to introduce supporting processes aimed at reducing membrane pore blocking by deposits and organic compounds, and in the case of ultrafiltration, assuring the safety of the purified stream in terms of the toxicological effect.
Źródło:
Journal of Ecological Engineering; 2017, 18, 4; 130-136
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies