Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Kapjor, Andrej" wg kryterium: Autor


Wyświetlanie 1-7 z 7
Tytuł:
Experimental study on thermal comfort at university buildings in Slovakia
Eksperymentalne badanie komfortu cieplnego w budynkach uniwersyteckich na Słowacji
Autorzy:
Orman, Łukasz J.
Kapjor, Andrej
Powiązania:
https://bibliotekanauki.pl/articles/2203969.pdf
Data publikacji:
2023
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
thermal comfort
thermal sensations
Fanger model
komfort cieplny
wrażenia cieplne
model Fangera
Opis:
The paper discusses the issue of thermal comfort expressed by the students of the University of Žilina in anonymous questionnaires. The volunteers rated their thermal sensations, preferences as well as lighting conditions in the autumn season. The students were in favour of the prevailing thermal conditions - almost 88% of the volunteers expressed positive opinions about their environment. The comparison of the test results for a computer laboratory with the Fanger model calculation results was also made and indicated differences between the experimental data and values determined with the model.
W artykule omówiono zagadnienie komfortu cieplnego studentów Uniwersytetu w Żylinie w oparciu o anonimowe ankiety. Ochotnicy oceniali swoje odczucia termiczne, preferencje oraz warunki oświetleniowe w okresie jesiennym. Studenci wyrazili się pozytywnie w zakresie panujących warunków termicznych - blisko 88% odpowiedzi. W pracy dokonano również porównania wyników badań w laboratorium komputerowym z wynikami obliczeń wg modelu Fangera i wykazano różnice między danymi eksperymentalnymi a wartościami wyznaczonymi modelem.
Źródło:
Structure and Environment; 2023, 15, 1; 1--5
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energy efficiency optimization of the operating room due to the dispositional location
Optymalizacja efektywności energetycznej w sali operacyjnej związana z lokalizacją systemu wentylacji
Autorzy:
Mičko, Pavol
Hečko, Dávid
Kapjor, Andrej
Vantúch, Martin
Hrnková, Bronislava
Powiązania:
https://bibliotekanauki.pl/articles/2055090.pdf
Data publikacji:
2021
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
energy efficiency
HVAC systems
energy consumption optimization
efektywność energetyczna
systemy HVAC
optymalizacja zużycia energii
Opis:
Clean rooms, including operating rooms, are energy-intensive. During their operation, the concentration of particles in the air, air temperature and humidity are strictly monitored. HVAC systems in the operating room are subject to high demands on maintaining a stable heat and humidity microclimate, as well as particle concentrations within the permitted range. To cover heat losses and heat loads of the building, it is necessary to dimension ventilation equipment with high outputs and high energy consumption. By suitable optimization of the dispositional location of the operating tract in the building and the use of suitable thicknesses of insulating material, it is possible to reduce the performance requirements for the HVAC system, which significantly reduces energy consumption. Heat loss and heat load of the operating tract were evaluated using TechCon software. The performance values of the heaters and coolers for the HVAC units were calculated in the VentiCad design software. The optimization indicates a significant reduction in heat loss and heat load, as well as a reduction in the required temperature of the air supplied to the room by more than 10°C.
Pomieszczenia czyste, łącznie z salami operacyjnymi wymagają dużo energii. Podczas ich pracy dokładnie monitoruje się stężenie cząstek stałych w powietrzu, jego temperaturę i wilgotność. Systemy grzewcze, wentylacji i klimatyzacji (HVAC) w salach operacyjnych podlegają wysokim wymaganiom związanym z utrzymaniem stabilnego mikroklimatu cieplno-wilgotnościowego, jak również stężenia cząstek w dozwolonym zakresie. Pokrycie strat i zysków ciepła budynku wymaga projektowania systemów wentylacyjnych o wysokim zużyciu energii. Poprzez odpowiednią optymalizację lokalizacji przewodów w budynku i zastosowanie właściwiej grubości materiału izolacyjnego możliwe jest odgraniczenie wymagań układów HVAC, co znacząco zmniejsza zużycie energii. Straty i zyski ciepła określono przy użyciu programu TechCon. Parametry nagrzewnic i chłodnic w układzie HVAC wyznaczono w programie VentiCad. Optymalizacja wskazuje na znaczącą redukcję strat i zysków ciepła, jak również zmniejszenie temperatury powietrza dostarczanego do pomieszczenia o więcej niż 10°C.
Źródło:
Structure and Environment; 2021, 13, 1; 29--34
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A study of thermal comfort at Kielce University of Technology
Badanie komfortu cieplnego na Politechnice Świętokrzyskiej
Autorzy:
Krawczyk, Natalia
Kapjor, Andrej
Powiązania:
https://bibliotekanauki.pl/articles/402332.pdf
Data publikacji:
2020
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
thermal comfort
thermal sensation
room air quality
komfort cieplny
odczucia termiczne
jakość powietrza w pomieszczeniu
Opis:
The article presents the research of thermal comfort based on the Fanger model. The research was conducted in three educational rooms. The study involved 98 people whose age is between 19 and 23 years old. The study consisted in measuring the parameters of the thermal environment. During the research, students completed surveys regarding the thermal sensation. On the basis of the research, the predicted mean vote PMV score and the predicted percentage of dissatisfied PPDs were determined. This made it possible to compare the assessment of respondents with those indicated according to the standard, which showed that the Fanger model does not reflect the results of the respondents. The best solution will be to modify the Fanger model.
W artykule przedstawiono badania komfortu cieplnego na podstawie modelu Fangera. Badania prowadzono w trzech pomieszczeniach edukacyjnych. Wzięło w nich udział 98 osób, których wiek zawiera się w przedziale od 19 do 23 lat. Badanie polegało na zmierzeniu parametrów środowiska termicznego. Podczas wykonywanych badań studenci wypełniali ankiety dotyczące odczucia cieplnego. Na podstawie przeprowadzonych badań określono przewidywaną średnią ocenę PMV oraz przewidywany odsetek osób niezadowolonych PPD. Pozwoliło to na porównanie oceny ankietowanych ze wskazanymi według normy, co pokazało, że model Fangera nie odzwierciedla wyników ankietowanych. Najlepszym rozwiązaniem będzie modyfikacja wzoru Fangera.
Źródło:
Structure and Environment; 2020, 12, 3; 127-132
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the conversion of primary energy into heat focused on a heat pump with a working substance (refrigerant) CO2
Analiza konwersji energii pierwotnej w ciepło przy zastosowaniu pompy ciepła z CO2 jako czynnikiem roboczym (chłodniczym)
Autorzy:
Hrnková, Bronislava
Hečko, Dávid
Kapjor, Andrej
Mičko, Pavol
Vantúch, Martin
Powiązania:
https://bibliotekanauki.pl/articles/2055092.pdf
Data publikacji:
2021
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
primary energy
heat pump
CO2
refrigerant
energy efficiency
energy demand
energia pierwotna
pompa ciepła
czynnik chłodniczy
efektywność energetyczna
zapotrzebowanie na energię
Opis:
The need for research in the field of energy efficiency and the ecological aspects of primary energy use is currently receiving considerable attention in the framework of European Union policy as well as in the Slovak Republic. It is necessary to deal with this issue not only for the needs of normal operations, but especially in the current situation, when due to the threat of the COVID-19 virus, the requirements for thermal energy are increased. A suitable way to achieve this is the use of renewable resources, in Slovakia mainly biomass, solar, wind, water and geothermal energy. Ambient air, ground heat, heat contained in groundwater and various other waste heat from technological processes represent a huge potential for the use of low-potential energy. The article is focused on solving the problem of conversion of primary energy into heat using thermodynamic cycles and compressor circulation with working substance (refrigerant) CO2.
Potrzeba badań w obszarze efektywności energetycznej i ekologicznych aspektów wykorzystania energii pierwotnej skupia obecnie dużo uwagi w ramach polityki Unii Europejskiej, jak również w Republice Słowackiej. Konieczne jest zajęcie się tym problemem nie tylko dla zapewnienia normalnego funkcjonowania, ale szczególnie w obecnej sytuacji, gdy w związku z zagrożeniem wirusem COVID-19 wzrastają wymagania i zapotrzebowanie na energię cieplną. Odpowiednim sposobem na osiągnięcie tego jest wykorzystanie zasobów odnawialnych, na Słowacji głównie biomasy, energii słonecznej, wiatrowej, wodnej i geotermalnej. Powietrze atmosferyczne, ciepło ziemi, ciepło zawarte w wodach gruntowych i różne inne rodzaje ciepła odpadowego z procesów technologicznych stanowią ogromny potencjał wykorzystania energii niskotemperaturowej. W artykule skupiono się na rozwiązaniu problemu konwersji energii pierwotnej na ciepło za pomocą obiegów termodynamicznych sprężarkowych z czynnikiem roboczym (chłodniczym) CO2.
Źródło:
Structure and Environment; 2021, 13, 2; 59--64
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Laminar field optimization in connection with the current pandemic situation caused by COVID-19
Optymalizacja z wykorzystaniem pola laminarnego w odniesieniu do obecnej sytuacji pandemicznej spowodowanej przez COVID-19
Autorzy:
Hrnková, Bronislava
Hečko, Dávid
Kapjor, Andrej
Mičko, Pavol
Vantúch, Martin
Powiązania:
https://bibliotekanauki.pl/articles/2055095.pdf
Data publikacji:
2021
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
laminar field
clean room
air flow
CFD model
outlet
pole laminarne
czyste pomieszczenie
przepływ powietrza
model CFD
wywiew
Opis:
COVID-19 is constantly spreading around the world. Doctors, nurses and medical staff spend more time providing their professional help than usual. It is especially important to provide them with a suitable working environment. Therefore, in the following article we will deal with the design of a computational model of a laminar field in a clean room using CFD methods.
COVID-19 nieustannie rozprzestrzenia się w świecie. Lekarze, pielęgniarki i personel medyczny spędzają więcej czasu niż zwykle niosąc profesjonalną pomoc. Jest zatem szczególnie istotne, aby zapewnić im odpowiednie środowisko pracy. Dlatego też w prezentowanym artykule zajęto się zaprojektowaniem modelu komputerowego pola laminarnego w czystym pomieszczeniu z wykorzystaniem metod CFD.
Źródło:
Structure and Environment; 2021, 13, 1; 5--9
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Requirement of pressure relief dampers for clean rooms
Potrzeba stosowania klap nadciśnieniowych do pomieszczeń czystych
Autorzy:
Hrnková, Bronislava
Hečko, Dávid
Kapjor, Andrej
Mičko, Pavol
Vantúch, Martin
Powiązania:
https://bibliotekanauki.pl/articles/2055093.pdf
Data publikacji:
2021
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
clean room
pressure dampers
supply air
pressure drop
air diffusers
pomieszczenie czyste
klapy nadciśnieniowe
dopływ powietrza
spadek ciśnienia
dyfuzory
Opis:
The clean room is designed and used to minimize the entry, generation and deposition of pollutants. Proper flow control is an important factor in determining the efficiency of clean rooms. It is important that the air stream entrains from the space all the particles that are released when people move, but also from equipment and various materials. Therefore, in the following article we will deal with the need for pressure dampers in clean rooms.
Pomieszczenie czyste jest zaprojektowane i wykorzystywane w taki sposób, aby zminimalizować wnikanie, generowanie i osadzanie się zanieczyszczeń. Właściwa kontrola przepływu powietrza jest istotnym czynnikiem określającym efektywność pomieszczeń czystych. Ważne jest, żeby strumień powietrza porywał z przestrzeni wszystkie cząstki, które są uwalniane podczas ruchu ludzi, ale także ze sprzętu i różnych materiałów. W związku z powyższym w niniejszym artykule zajmiemy się potrzebą stosowania klap nadciśnieniowych w pomieszczeniach czystych.
Źródło:
Structure and Environment; 2021, 13, 2; 55--58
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modern Methods of Thermal Comfort Measurements
Nowoczesne metody badań komfortu cieplnego
Autorzy:
Dębska, Luiza
Krakowiak, Justyna
Kapjor, Andrej
Powiązania:
https://bibliotekanauki.pl/articles/1833731.pdf
Data publikacji:
2020
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
thermal comfort
measurement methods
PMV
komfort cieplny
metody pomiaru
Opis:
The issue of thermal comfort and its subjective feelings inside a building is becoming more and more important in the modern world. It is caused by the desire to create optimal conditions in places where people stay. The article presents two methods, indirect and direct, which are typically used in the research projects. These methods enable to assess the thermal sensations of people and compare the feelings of the respondents with the value of PMV (the value of human thermal sensations) calculated using the formula from the ISO 7730 standard and the questionnaire surveys.
Zagadnienie komfortu cieplnego oraz jego subiektywnych odczuć wewnątrz budynku staje się coraz ważniejsze we współczesnym świecie. Spowodowane jest to chęcią stworzenia optymalnych warunków w miejscach przebywania ludzi. W artykule przedstawiono dwie metody, pośrednią oraz bezpośrednią, które powszechnie stosuje się w badaniach. Metody te umożliwiają ocenę wrażeń cieplnych ludzi i porównanie odczuć osób ankietowanych z wartością PMV (wartością wrażeń cieplnych człowieka) obliczoną za pomocą wzoru z normy ISO 7730 z danymi z kwestionariuszy.
Źródło:
Structure and Environment; 2020, 12, 4; 161--165
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies