Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Kania, Jarosław" wg kryterium: Autor


Wyświetlanie 1-9 z 9
Tytuł:
Transport parameters of selected neonicotinoids in different aquifer materials using batch sorption tests
Autorzy:
Pietrzak, Damian
Kania, Jarosław
Kmiecik, Ewa
Powiązania:
https://bibliotekanauki.pl/articles/2172910.pdf
Data publikacji:
2022
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
pesticides
neonicotinoids
transport parameters
sorption
batch tests
soil
Opis:
Contamination of surface and groundwater by neonicotinoids is a global problem and requires comprehensive action by individual countries in order to identify in detail the processes affecting the transport of these pesticides, their properties, and their harmfulness to the environment. The aim of this study was to assess the transport (expressed by sorption parameters) of selected neonicotinoids in the aquatic environment, using batch tests. Tests were carried out for acetamiprid individually and a mixture of five neonicotinoids (acetamiprid, clothianidin, imidacloprid, thiacloprid, and thiamethoxam), for three different aquifer materials and quartz sand. Based on the obtained values of the sorption parameters, the greatest sorption of neonicotinoids was observed on soil with the highest content of organic matter and clay minerals content, while no sorption of these pesticides was observed on quartz sand. In addition, it was noticed that individual neonicotinoids undergo sorption to a different degree — thiacloprid was the most sorbed (R-value in the range 3.13–26.03), while thiamethoxam was the least (R-value in the range 1.89–8.41).
Źródło:
Geology, Geophysics and Environment; 2022, 48, 4; 367--379
2299-8004
2353-0790
Pojawia się w:
Geology, Geophysics and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Identification of transport parameters of chlorides in different soils on the basis of column studies
Autorzy:
Pietrzak, Damian
Kania, Jarosław
Kmiecik, Ewa
Wątor, Katarzyna
Powiązania:
https://bibliotekanauki.pl/articles/94612.pdf
Data publikacji:
2019
Wydawca:
Uniwersytet im. Adama Mickiewicza w Poznaniu
Tematy:
pore-water velocity
dispersion coefficient
dispersivity constant
CXTFIT
STANMOD
współczynnik dyspersji
stała dyspersyjności
Opis:
Knowledge of transport patterns of chemicals in groundwater is essential for environmental assessment of their potential impact. In the present study, the mobility of a chloride tracer injected into three different soils was investigated, using column experiments. The column tests were performed under steady-state conditions to determine parameters of chloride migration through soils. Based on breakthrough curves, pore-water velocity, dispersion coefficient and dispersivity constant were calculated for each soil sample using CXTFIT/STANMOD software. Pore-water velocity was in the range of 0.31 cm/min for fine sand, to 0.35 cm/min for silty sand and to 0.40 cm/min for vari-grained sand. The highest values of dispersion coefficient and dispersivity constant were observed for silty sand (0.55 cm2/min and 1.55 cm, respectively), while the lowest value was found for fine sand (0.059 cm2/min and 0.19 cm, respectively). Column experiments for chlorides (conservative tracer) are a preliminary stage for further research which will be undertaken to investigate migration parameters of selected neonicotinoids (reactive tracers) through different soils.
Źródło:
Geologos; 2019, 25, 3; 225-229
1426-8981
2080-6574
Pojawia się w:
Geologos
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optymalizacja właściwości balistycznych blach ze stali nanostrukturalnej bainitycznej przeznaczonych na opancerzenie kontenera LOOK
Optimisation of ballistic properties of nanostructured bainitic steel plates for container armour system
Autorzy:
Marcisz, Jarosław
Garbarz, Bogdan
Zalecki, Władysław
Kania-Pifczyk, Zofia
Starczewski, Lech
Gołuński, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/235593.pdf
Data publikacji:
2019
Wydawca:
Wojskowy Instytut Techniczny Uzbrojenia
Tematy:
stal nanostrukturalna
ochrona balistyczna
kontener opancerzony
nanostructured steel
ballistic protection
armoured container
Opis:
W celu podwyższenia właściwości eksploatacyjnych kontenera obserwacyjno-obronnego LOOK opracowywane jest innowacyjne opancerzenie, którego elementy będą wykonane z blach ze stali nanostrukturalnej bainitycznej, co zapewni poziom 2 ochrony wg STANAG 4569. Z uwagi na odmienne właściwości mechaniczne i technologiczne tych blach w odniesieniu do blach pancernych stosowanych obecnie, modyfikacji uległa konstrukcja opancerzenia kontenera. Artykuł zawiera wyniki badań charakterystyk materiałowych oraz testów ostrzałem blach ze stali nanostrukturalnej wytworzonych w warunkach półprzemysłowych. W celu optymalizacji parametrów obróbki cieplnej blach wykonano badania kinetyki przemian fazowych, a następnie dla różnych wariantów obróbki prze-prowadzono pomiary właściwości mechanicznych oraz analizę zmian mikrostruktury i właściwości w miejscach oddziaływań pocisków w trakcie testów ostrzałem. Przedstawione badania poprzedzają uruchomienie procesu produkcji blach arkuszowych z nowego gatunku stali do produkcji systemu opancerzenia kontenera LOOK. Optymalizację właściwości mechanicznych blach wykonano przez dobór następujących parametrów wytwarzania: składu chemicznego stali, przeróbki plastycznej i wstępnej obróbki cieplnej oraz temperatury i czasu finalnej obróbki cieplnej (wygrzewania izotermicznego). W badaniach zwrócono uwagę na wpływ segregacji pierwiastków stopowych i domieszkowych na właściwości ochronne blach. W wyniku zastosowania temperatury wygrzewania w zakresie 210-225°C (temperatura MS = ok. 200°C dla szybkości chłodzenia 1-2 °C/s) i czasu odpowiednio w przedziale 120-70 godzin uzyskano następujące właściwości mechaniczne materiału: Rp0,2 1400-1500 MPa, Rm 2000-2150 MPa; A 10-13%; KV (w temp. otoczenia) 10-16 J oraz twardość 590-610 HV10 (53-54 HRC). Mikrostrukturę blach stanowił bezwęglikowy nanobainit listwowy oraz austenit resztkowy w ilości 10-21%. W testach ostrzałem zastosowano blachy o grubości 6,3 i 7,5 mm oraz amunicję 5,56x45 mm M193 i 7,62x51 mm API BZ. Na podstawie wyników tych testów oraz badań mikrostruktury w miejscach ostrzału stwierdzono występowanie zjawisk świadczących o wysokiej skuteczności ochronnej badanych blach, przejawiających się dużą zdolnością do pochłaniania i rozpraszania energii pocisku bez skłonności do pękania. Na podstawie wyników badań właściwości mechanicznych i testów ostrzałem blach eksperymentalnych, opracowano skład chemiczny stali nanostrukturalnej bainitycznej, dostosowany do wykonania w warunkach przemysłowych blach o grubości w zakresie 6-8 mm. Przeprowadzono analizę możliwości obniżenia masy opancerzenia kontenera na podstawie wyników badań blach ze stali nanostrukturalnej wytworzonych w warunkach półprzemysłowych. Na podstawie analizy konstrukcji i warunków użytkowania kontenera wskazano obszary newralgiczne z punktu widzenia ochrony balistycznej, które poddane będą testom ostrzałem. Badania balistyczne zostaną wykonane na segmentach kontenera reprezentujących wytypowane obszary newralgiczne.
An innovative armour system containing plates made of nanostructured bainite steel is under development to improve operating properties of a light armoured observation-protective container (LAOC) providing the 2nd protection level according to STANAG 4569. Armour system solution of the container has been modified because the new plates have different mechanical and technological properties than currently used armour plates. The paper presents results of investigation of material characteristics and firing tests of plates made of nanostructured steel in the semi-industrial scale. To optimise parameters of heat treatment of the plates the kinetics of phase transformation was examined, and mechanical properties were measured, and changes in microstructure in the area of projectile interaction at firing tests were analysed for different variants of treatment. The reported investigations precede the industrial scale production process for plates made of the new grade steel designed for the armour system of LAOC. Optimisation of mechanical properties of the plates has been carried out by selection of such production parameters as chemical composition of the steel, hot working, interprocess heat treatment and temperature and time of final heat treatment (isothermal annealing). Effect of primary segregation of alloying and residual elements on protective properties of the plates is indicated. As a result of applying the annealing temperature in the range of 210-225°C (Ms temperature is ca. 200°C at cooling rate 1-2°C/s) and time in the range of 120-70 hours respectively, the following properties have been achieved: YS0.2 (yield strength) 1400-1500 MPa; UTS (ultimate tensile strength) 2000-2150 MPa; TE (total elongation) 10-13%, impact toughness KV at room temperature 10-16 J and hardness 590-610 HV (53-54 HRC). Microstructure of the plates consists of carbide free lathy nanobainite and 10-21% (volume fraction) of retained austenite. Plates of thickness 6.3 and 7.5 mm and ammunition type of 5.56x45 mm M193 and 7.62x51 mm API BZ have been used in the firing tests. Based on results of firing tests and microstructure examination in the area of projectile interaction the phenomena have been identified indicating high efficiency of ballistic protection of investigated plates, manifested by high ability to absorption and dissipation of projectile energy without susceptibility to cracking. Based on the results of mechanical properties measurements and firing tests a chemical composition of the nanostructured bainitic steel adjusted for industrial production of plates of thickness in the range of 6-8 mm has been developed. An analysis of container armour system mass reduction possibility, basing on results of investigation of the nanostructured bainite steel plates made in the semi-industrial scale, has been carried out. Basing on the analysis of the container construction and operational conditions some sensitive areas of ballistic protection have been specified to be subjected to firing tests. Ballistic examination will be carried out using the container segments representing the selected sensitive areas.
Źródło:
Problemy Techniki Uzbrojenia; 2019, 48, 151; 97-119
1230-3801
Pojawia się w:
Problemy Techniki Uzbrojenia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tonsillectomy in own material
Autorzy:
Bant, Przemysław
Szczygielski, Kornel
Cierniak, Szczepan
Kosek, Jarosław
Kania, Joanna
Sienicki, Rafał
Jurkiewicz, Dariusz
Powiązania:
https://bibliotekanauki.pl/articles/1397346.pdf
Data publikacji:
2020
Wydawca:
Index Copernicus International
Tematy:
chronic tonsillitis
histopathological examination
palatine tonsil
tonsillar hyperthrophy
Opis:
Introduction: Tonsillectomy belongs to the most frequently performed surgical treatments; however, the necessity of its performance is questioned. Therefore, there are many attempts to unify and define the indications for the procedure. Aim: The main objective of the current dissertation was an analysis of the clinical symptoms occurring in patients qualified for tonsillectomy, as well as a comparison of those with a histopathological image of the removed tonsils in a repeatedly carried out, unified pathomorphological examination. The secondary objective was the designation of the demographic profile, existing comorbidities, and complications in the form of postoperative bleeding in patients after tonsillectomy in own material. Material and method: A retrospective analysis of 301 procedures of palatine tonsil removal was performed, which were completed in the years 2017–2019 at the Department of Otolaryngology with Division of Cranio-Maxillo-Facial Surgery of the Military Institute of Medicine, Warsaw, Poland. The indications were defined on the grounds of data from the anamnesis. Based on unified criteria, the removed material was divided into 2 groups: with the signs of Chronic Tonsillitis (CT) as well as Tonsillar Hyperthrophy (TH). Results: The average size of tonsils was the greatest in a group of patients under 35 years of age, and smallest in the group over 51 years of age. As patients aged, the reduction in size of the palatal tonsils was observed. In the examined group, the histopathological diagnosis in the form of HT was found in 165 patients (54.8%), while CT in 136 (45.2%). It was proven that the larger the tonsils in the clinical picture, the more often the histopathological image responded to HT. Among clinical symptoms reported by patients qualified for tonsillectomy, the following were observed: recurring tonsil inflammation in 211 (70.1%), snoring and sleep apnea in 47 (15.6%), as well as sleep apnea in 33 (11%) patients. Primary bleeding occurred in 10 patients (3.34%), and secondary in 8 patients (2.66%). The most common comorbidities were cardiovascular burdens. Conclusions: For most cases, clinical symptoms were confirmed by adequate features of removed material in histopathological examination. The most common histopathological diagnosis was tonsillar hyperthrophy.
Źródło:
Polish Journal of Otolaryngology; 2020, 74, 6; 29-34
0030-6657
2300-8423
Pojawia się w:
Polish Journal of Otolaryngology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Londyńska reduta. 2, Prezydenci RP na uchodźstwie i działalność polskiej emigracji niepodległościowej
Prezydenci RP na uchodźstwie i działalność polskiej emigracji niepodległościowej
Współwytwórcy:
Golon, Mirosław (1964- ). Redakcja
Kania, Krzysztof (1976- ). Redakcja
Girzyński, Zbigniew (1973- ). Redakcja
Kłaczkow, Jarosław (1972- ). Redakcja
Wydawnictwo Adam Marszałek. Wydawca
Data publikacji:
2017
Wydawca:
Toruń : Wydawnictwo Adam Marszałek
Tematy:
Rząd Rzeczypospolitej Polskiej na uchodźstwie
Prezydenci
Emigracja polityczna
Polacy za granicą
Praca zbiorowa
Biografia
Opis:
Bibliografia na stronach [221]-250. Indeks.
Dostawca treści:
Bibliografia CBW
Książka
    Wyświetlanie 1-9 z 9

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies