Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Kabaciński, J." wg kryterium: Autor


Wyświetlanie 1-14 z 14
Tytuł:
Packet switch architecture with multiple output queueing
Autorzy:
Danilewicz, G.
Głąbowski, M.
Kabaciński, W.
Kleban, J.
Powiązania:
https://bibliotekanauki.pl/articles/308342.pdf
Data publikacji:
2004
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
high-speed packet switching
output queueing
buffer
switch fabric
switching node
multicast
Opis:
In this paper the new packet switch architecture with multiple output queuing (MOQ) is proposed. In this architecture the nonblocking switch fabric, which has the capacity of N _N2 N2, and output buffers arranged into N separate queues for each output, are applied. Each of N queues in one output port stores packets directed to this output only from one input. Both switch fabric and buffers can operate at the same speed as input and output ports. This solution does not need any speedup in the switch fabric as well as arbitration logic for taking decisions which packets from inputs will be transferred to outputs. Two possible switch fabric structures are considered: the centralized structure with the switch fabric located on one or several separate boards, and distributed structure with the switch fabric distributed over line cards. Buffer arrangements as separate queues with independent write pointers or as a memory bank with one pointer are also discussed. The mean cell delay and cell loss probability as performance measures for the proposed switch architecture are evaluated and compared with performance of OQ architecture and VOQ architecture. The hardware complexity of OQ, VOQ and presented MOQ are also compared. We conclude that hardware complexity of proposed switch is very similar to VOQ switch but its performance is comparable to OQ switch.
Źródło:
Journal of Telecommunications and Information Technology; 2004, 4; 76-83
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Performance evaluation of the multiple output queueing switch with different buffer arrangements strategy
Autorzy:
Danilewicz, G.
Kabaciński, W.
Pleban, J.
Parniewicz, D.
Dąbrowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/308008.pdf
Data publikacji:
2006
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
packet switching
switch fabric
multiple output queueing
Opis:
Performance evaluation of the multiple output queueing (MOQ) switch recently proposed by us is discussed in this paper. In the MOQ switch both the switch fabric and buffers can operate at the same speed as input and output ports. This solution does not need any speedup in the switch fabric as well as any matching algorithms between inputs and outputs. In this paper new performance measures for the proposed MOQ switch are evaluated. The simulation studies have been carried out for switches with different buffer arrangements strategy and of capacity 2×2, 4×4, 8×8, 16×16 and 32×32, and under selected traffic patterns. The simulations results are also compared with OQ switches of the same sizes.
Źródło:
Journal of Telecommunications and Information Technology; 2006, 3; 43-48
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reference values of spatiotemporal parameters, joint angles, ground reaction forces, and plantar pressure distribution during normal gait in young women
Autorzy:
Fryzowicz, A.
Murawa, M.
Kabaciński, J.
Rzepnicka, A.
Dworak, L. B.
Powiązania:
https://bibliotekanauki.pl/articles/307416.pdf
Data publikacji:
2018
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
kobieta
kinematyka
biomechanika chodu
pedobarografia
women
kinematics
ground reaction forces
gait biomechanics
pedobarography
reference data
Opis:
The aim of this study was to establish the reference values of spatiotemporal parameters, joint angles, ground reaction forces and plantar pressure distribution collected simultaneously on the same measurement path during normal gait in a homogenous group of young, healthy women. Methods: The studied group consisted of 28 healthy women aged 21 years on average. The motion capture system BTS Smart-D, 2 AMTI force platforms and Footscan pedobarographic platform were used in this research. The 14-metre measurement path and the 6-metre distance that examined women had to walk through before entering the measurement area ensured that a natural gait pattern was recorded. Statistical analysis was performed to evaluate differences between right and left lower extremities. Results: The applied method enabled collecting several parameters regarding normal female gait biomechanics such as: spatiotemporal parameters, angle-time characteristics as well as range of motion of pelvis, hip, knee and ankle joints in gait cycle, force-time characteristics and peaks of ground reaction force components in stance phase, peak pressure and time of loading of defined foot regions in stance phase. Conclusions: The results may be used by clinicians, physiotherapists or researchers as a reference in diagnosing gait disorders or evaluating patient’s walking pattern. In recent literature there are some disparities in gait parameters reference values even regarding similar research groups. These differences may arise from distinct method, slower or faster gait, other laboratory environment etc. This should be considered and more than one source of normative values should be checked when searching for reference data.
Źródło:
Acta of Bioengineering and Biomechanics; 2018, 20, 1; 49-57
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Parametry wyskoku pionowego a wartości momentów siły mięśniowej kończyn dolnych tancerzy zawodowych
Vertical jump parameters and lower extremities muscles torques of professional dancers
Autorzy:
Gorwa, J.
Kabaciński, J.
Murawa, M.
Mączyński, J.
Dworak, L.
Powiązania:
https://bibliotekanauki.pl/articles/98692.pdf
Data publikacji:
2017
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
CMJ
SJ
moment siły mięśniowej
statyka
taniec zawodowy
extremities muscles torques
statics
professional dance
Opis:
Praca przedstawia związki pomiędzy parametrami skoku pionowego i wartościami względnych, momentów sił wybranych grup mięśniowych, kończyn dolnych, dla 43 tancerzy zawodowych uprawiających dwa, odmienne style taneczne: klasykę oraz taniec współczesny. Parametry CMJ i SJ oraz wartości względne, wybranych momentów siły mięśniowej kończyn dolnych mierzonych w warunkach statyki, są ze sobą powiązane, a najistotniejszymi informacjami wyciągniętymi w toku analiz do niniejszej pracy, jest wpływ danego stylu tańca na parametry CMJ i SJ.
The study presents correlations between vertical jump parameters and relative values of selected muscles torques of lower extremities of 43 professional dancers who practice two different styles of dance: classic and modern. CMJ and SJ parameters turned out to be slightly correlated with relative values of selected muscles torques measured in static conditions. The analysis mainly focused on the influence of the dance style on the CMJ and SJ parameters.
Źródło:
Aktualne Problemy Biomechaniki; 2017, 13; 21-28
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Accuracy analysis of stowing computations for securing non-standard cargoes on ships according to IMO CSS Code
Autorzy:
Kabaciński, J.
Wiśnicki, B.
Powiązania:
https://bibliotekanauki.pl/articles/258714.pdf
Data publikacji:
2009
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
safety of transportation
stowing
cargo securing
non-standard cargoes
lashing
Opis:
The article takes up a subject of effectiveness of securing arrangements while stowing non-standard cargoes on ships. Accuracy analysis of stowing calculations was based on procedures proposed by Code of Safe Practice for Cargo Stowage and Securing – CSS Code. Detailed calculations of forces and moments related to lashings, which prevents non-standard cargo against transverse tipping, were performed. Some simplifications were proven that may result in underestimating or overstating the calculated righting moment, which decides of safety margin of securing non-standard cargoes. The alternative more reliable procedure, without simplifications, was proposed.
Źródło:
Polish Maritime Research; 2009, 2; 67-71
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dynamic load indicators for take-off–landing sequence in blocks and attacks of elite female volleyball players
Autorzy:
Kabaciński, J.
Dworak, L. B.
Murawa, M.
Rzepnicka, A.
Powiązania:
https://bibliotekanauki.pl/articles/307295.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
siła reakcji podłoża
obciążenie dynamiczne
start
atak
biomechanika
ground reaction forces
take-off–landing
dynamic loads
blocks
attacks
volleyball
biomechanics
Opis:
Purpose: Dynamic loads during landings determined by the ground reaction forces (GRFs) may elaborate internal loads and increase the risk of overload knee injuries as a result of performing volleyball jumps many times. The study dealt with a biomechanical assessment of dynamic load indicators in female volleyball players for the motion sequence of take-off–landing in blocks and attacks. Methods: Twelve professional female volleyball players participated in the study. Blocks and attacks were filmed by two cameras. GRFs vs. time graphs were recorded with the use of a force platform. Values of dynamic load indicators in terms of the relations of peak of vertical component of GRF, build-up index of this force (BIF), and power output (P) during landing to the vGRF, BIF and P during take-off (L/T) were calculated. Results: The statistically significant ( p < 0.05) highest values of L/T indicators were found for back row attack spikes: 2.4 (vGRF), 12.2 (BIF) and 3.1 (P). In the case of blocks, slide attack spikes and attack line spikes, results of these variables were in range: 1.8÷2.1, 5.9÷7.6 and 2.1÷2.9, respectively. Conclusions: The reduction of GRFs during landings contributes to decreasing the level of the load indicators L/T which should minimize the incidence of anterior cruciate ligament and patellar tendon injuries in female volleyball players.
Źródło:
Acta of Bioengineering and Biomechanics; 2016, 18, 1; 41-46
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Izokinetyczna ocena ekscentrycznej siły mięśni grupy tylnej i przedniej uda siatkarzy
Isokinetic evaluation of hamstrings and quadriceps eccentric muscles strength in volleyball players
Autorzy:
Kabaciński, J.
Murawa, M.
Żyła, T.
Gorwa, J.
Dworak, L. B.
Powiązania:
https://bibliotekanauki.pl/articles/98678.pdf
Data publikacji:
2017
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
izokinetyka
siła ekscentryczna
staw kolanowy
siatkówka
isokinetics
eccentric strength
knee joint
volleyball
Opis:
W pracy określono wartości wybranych wskaźników ekscentrycznej siły mięśni uda siatkarzy w warunkach izokinetycznych. Ocenie poddano stosunek momentu siły hamstrings do quadriceps (H/Q) oraz bilateralny deficyt maksymalnego momentu siły mięśni (BD) dla prędkości kątowych 30°/s, 60°/s i 90°/s. Wartości maksymalnego H/Q zawierały się od 69.0% (90°/s) do 81.3% (30°/s), natomiast średniego H/Q od 68.6% (90°/s) do 78.7% (30°/s). Ponadto, stwierdzono nieistotny BD (poniżej 7%) dla obu zespołów mięśniowych.
In the study the values of selected indicators of thigh eccentric isokinetic strength in volleyball athletes at angular velocities 30°/s, 60°/s and 90°/s was determined. The evaluation included the hamstrings to quadriceps torque ratio (H/Q) and peak torque bilateral deficit (BD). The peak H/Q values ranged from 69.0% (90°/s) to 81.3% (30°/s), whereas average H/Q values ranged from 68.6% (90°/s) to 78.7% (30°/s). Moreover, no significant BD values (less than 7%) were found for both muscle groups.
Źródło:
Aktualne Problemy Biomechaniki; 2017, 12; 35-40
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of flowing fluid effect on flow averaging tube
Autorzy:
Kabaciński, M.
Lachowicz, C.
Pospolita, J.
Powiązania:
https://bibliotekanauki.pl/articles/1943247.pdf
Data publikacji:
2008
Wydawca:
Politechnika Gdańska
Tematy:
flow averaging tubes
numerical simulations
flow measurements
Opis:
This paper presents a mathematical model and results of numerical simulations for a fluid flow around a flow averaging tube. The calculations have been performed using the commercially available FLUENT software. The authors have applied the currently known studies of the models of turbulence and their applicability in certain flow conditions and hence selected the RNG k-epsylon turbulence model including appropriate functions to be used for determination of pressures and velocities at the sites of occurrence of considerable gradients. The distributions of pressures and velocities around a sensor are presented along with pressure distributions, instantaneous and averaged in time, on the measuring tube surface. The paper determines the frequencies of measuring tube free vibrations for one sided and two-sided tube fitting for the tube length in the range 100–1500mm. This analysis has been conducted with the aid of solving equations for free undamped vibrations for specific models. The graphical presentation involves an admissible range of tube lengths with one and two-sided fitting for the specified flowing air velocities.
Źródło:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk; 2008, 12, 3-4; 217-226
1428-6394
Pojawia się w:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Flow averaging tube geometry improvement for K-factor stability increase
Autorzy:
Kabaciński, M.
Pospolita, J.
Powiązania:
https://bibliotekanauki.pl/articles/114099.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
velocity profiles
air flow measurement
closed conduits
automated test stand
flow averaging Pitot tube
Opis:
Fluid flow around two-profile averaging differential pressure sensor was investigated in this paper. Research concentrated particularly on fluid movement direction and velocity over the investigated flow sensor. Analysis was conducted experimentally in low velocity wind tunnel. Because of large number of measuring points placed very close to each other, it was decided that velocity profile measurement will be performed by means of fully automated test stand. Due to a recirculation of the stream in the vicinity of the probe tested in the wind tunnel, an original two-direction probe was used. A linear module with a stepper motor formed an integral part of the measurement system. The location of the measuring probe, the possibility of adjusting stream mean velocities and data acquisition was undertaken by means of a dedicated program. The above mentioned investigation method helped to improve the metrological properties of the flowmeter applying non symmetrical probe cross-section forced air stream to be redirected in the desired direction. This modification significantly increased K-factor value and stability of air flow through the contraction of the flowmeter.
Źródło:
Measurement Automation Monitoring; 2017, 63, 1; 2-5
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical analysis of flow averaging tubes in the vortex-shredding regime
Numeryczna analiza drgań czujników uśredniających ciśnienie dynamiczne
Autorzy:
Kabaciński, M.
Lachowicz, C. T.
Pospolita, J.
Powiązania:
https://bibliotekanauki.pl/articles/139634.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
computational fluid dynamics (CFD)
numerical analysis of vibration
averaging Pitot tubes
flowmeter
obliczeniowa dynamika płynów
analiza numeryczna wibracji
rurki uśredniające Pitota
przepływomierz
Opis:
This paper presents a study on flowmeters oscillatory motion when subjected to periodical, enforced vibrations induced by vortex-shedding. The proposed mathematical modelling of flow was compared to corresponding numerical simulation, in form of modal analysis. The frequencies of vortices generation and detachment were calculated for a number of flow velocities in two different flowmeter profile variants. The performed modal evaluation enabled estimating their natural frequencies, and in consequence the acquired data helped us to determine flow velocity for which the analyzed structures were prone to resonant vibrations.
W artykule zaprezentowano proces oddziaływania wymuszonych przepływem płynu wirów na drgania przepływomierzy spiętrzających. Zaproponowany model matematyczny przepływu porównano z wynikami symulacji numerycznych w formie analizy modalnej. Częstotliwość generowania i odrywania się wirów policzono dla różnych predkości przepływu dla czujnika jedno- i dwuprofilowego. Przeprowadzone analizy modalne umożliwiły wyznaczenie ich częstotliwości, a w rezultacie pomogły w wyznaczeniu prędkości przepływu, dla których analizowany czujnik podatny jest na zjawisko rezonansu.
Źródło:
Archive of Mechanical Engineering; 2013, LX, 2; 283-297
0004-0738
Pojawia się w:
Archive of Mechanical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stanowisko laboratoryjne do badań przepływomierzy
Laboratory stand for flowmeters tests
Autorzy:
Kabaciński, M.
Kabza, Z.
Pospolita, J.
Powiązania:
https://bibliotekanauki.pl/articles/277605.pdf
Data publikacji:
2010
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
pomiary przepływów
rurki uśredniające ciśnienie dynamiczne
badania eksperymentalne
automatyzacja pomiarów
flow measurements
flow averaging tubes
experimental tests
measurement automation
Opis:
W artykule omówiono budowę i zasadę działania zautomatyzowanego stanowiska do badania i wzorcowania przepływomierzy spiętrzających przepływ. Przedstawiono podstawowe elementy wchodzące w skład stanowiska: tunel aerodynamiczny typu otwartego oraz zespół rurociągów o średnicach od 104 do 381 mm wraz z instrumentami pomiarowymi. Stanowisko zarządzane było autorskimi programami pracującymi w środowisku LabView, dzięki którym możliwe było m.in. wyznaczanie charakterystyk współczynnika przepływu K rurek uśredniających ciśnienie dynamiczne w czasie rzeczywistym oraz ich archiwizacja w celu przygotowania charakterystyk metrologicznych. Zamieszczono w pracy analizę niepewności pomiaru rurkami uśredniającymi ciśnienie dynamiczne oraz wykresy współczynnika przepływu dla wybranych średnic rurociągu i porównano je ze sobą. Sformułowano wnioski natury metrologicznej.
In this article it was discussed construction and principle of operation of automated measurement stand for testing differential pressure flowmeters. It was shown basic elements of measurement stand: open type wind tunnel and system of pipelines (D=104-381 mm) with measurement instrumentation. This stand was controlled by means of author’s computer programs working in LabView environment. The programs served to observe flow coefficient K in real time and to archive them in order to prepare metrological characteristics. Additionally it was placed metrological uncertainty analysis using two-profile Flow Averaging Tube and its flow coefficient K characteristics for selected diameters of pipeline. Results of measurements was compared to each other for different pipeline diameters. Metrological summary was formulated.
Źródło:
Pomiary Automatyka Robotyka; 2010, 14, 10; 53-57
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dynamic parameters of three-point crutch gait in female patients after total hip arthroplasty
Autorzy:
Murawa, M.
Dworak, L. B.
Kabaciński, J.
Syczewska, M.
Rzepnicka, A.
Powiązania:
https://bibliotekanauki.pl/articles/951831.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
staw biodrowy
endoproteza
biomechanika
total hip arthroplasty
three-point crutch gait
partial weight bearing
biomechanics
Opis:
Purpose: Patient recovery after a surgical procedure depends, among other factors, on the amount of the body weight with which patient loads lower limb. Research studies report different results of the degree of body weight with which lower limb is loaded during three-point crutch gait. The aim of this study was to evaluate the level of the ground reaction forces (GRF) during crutch gait used by patients after total hip arthroplasty (THA) in the first week after discharge from the orthopaedic units. Methods: Ten female patients diagnosed with primary unilateral coxarthrosis participated in a single measurement session. In order to record kinematic and dynamic variables of this gait pattern motion analysis system was used together with two force plates. The static test of body weight distribution between lower limbs was performed on a dual-top stabilometric plate. Results: The average peak values of loading on the operated (O) limb during mid stance and terminal stance of three-point crutch gait were 64.6% and 64.3% of body weight (BW), respectively, whereas in the case of the nonoperated (NO) limb 103.5%BW and 108.8%BW, respectively. The maximum loads on the crutches were significantly higher (by 9%BW) on the NO side as compared to the O side ( p < 0.05). During the static test, average values of body weight distribution on the O and NO limb were 36%BW and 64%BW, respectively. Conclusions: The patients showed surprisingly similar level of loading on the O limb. The weight bearing on the O limb was lower during static trial than during three-point crutch gait.
Źródło:
Acta of Bioengineering and Biomechanics; 2016, 18, 2; 131-135
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of typical flow disturbing elements on the flow rate in selected averaging Pitot tubes
Autorzy:
Pochwała, S.
Kabaciński, M.
Pospolita, J.
Powiązania:
https://bibliotekanauki.pl/articles/1933974.pdf
Data publikacji:
2012
Wydawca:
Politechnika Gdańska
Tematy:
averaging pitot tubes
flowmeter
Opis:
Flowmeters with averaging Pitot tubes are becoming more and more common in the industrial practice. It is often the case in long straight sections of channels with large diameters that the conditions regarding the adequately long sections of pipelines before and behind a flowmeter cannot be fulfilled. This is associated with the occurrence of an additional measurement uncertainty with an unknown value. Most of the information regarding this issue can be found for the case of Venturi probes. The amount of data regarding the flow averaging Pitot tubes is also limited. Hence, the decision to undertake the proposed subject. The conducted research made it possible to state recommendations regarding the metrology of testing. The results indicate that it is not only the distance from the flow disturbing element that plays a role but it is also the plane in which the sensor is located that affects the uncertainty of measurements of the flow averaging Pitot tubes.
Źródło:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk; 2012, 16, 3-4; 219-228
1428-6394
Pojawia się w:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Własności metrologiczne i możliwości zastosowań przepływomierzy z rurkami spiętrzającymi oraz mikrozwężkami
Metrological properties and ability applications of self averaged pitot probes and micro - venturi tubes
Autorzy:
Pospolita, J.
Kabaciński, M.
Chwastek, C.
Powiązania:
https://bibliotekanauki.pl/articles/158087.pdf
Data publikacji:
2004
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
własności metrologiczne
zastosowania przepływomierzy
rurki spiętrzające
mikrozwężki
metrological properties
ability of applications
flowmeters
Opis:
W pracy przedstawiono rozwiązania konstrukcyjne przepływomierzy piętrzących, w których czujnikami są rurki uśredniające ciśnienie dynamiczne oraz mikrozwężki. Podano przykłady numerycznych badań piętrzących czujników przepływu. Omówiono ich własności metrologiczne i eksploatacyjne. Podano przykłady zastosowań.
Constructions of impact flowmeters based on averaged pitot probes and micro - venturi tubes are presented in this paper. Examples of numerical simulations of impact flowmeters are displayed. Metrological and operating properties of these probes are shown. Moreover examples of their applications are given.
Źródło:
Pomiary Automatyka Kontrola; 2004, R. 50, nr 12, 12; 22-25
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-14 z 14

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies