Tytuł:
Angular position determination of heart valves in the pediatric ventricular assist device with use of computational fluid dynamics
Autorzy:
Jodko, D.
Obidowski, D.
Reorowicz, P.
Kłosiński, P.
Jóźwik, K.
Powiązania:
https://bibliotekanauki.pl/articles/98935.pdf
Data publikacji:
2014
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
CFD
pediatric VAD
heart valve
blood stagnation
sztuczna komora serca
zastawka serca
zastój krwi
Opis:
This study shows a method than can be used to determine the best angular position of heart valves installed at the inlet and the outlet of a blood chamber during the diastolic phase with use of Computational Fluid Dynamics (CFD). Steady state simulations of the blood flow through the blood chamber of Pediatric Ventricular Assist Device (PVAD) have been performed with ANSYS CFX 14.0. Main assumptions in the present paper have included: motionless discs, rigid walls, non-Newtonian model of blood. The obtained results show that areas of blood stagnation in the blood chamber are smallest for one particular angular position of the inlet valve and are not significantly dependent on the angular position of the outlet valve.
Źródło:
Aktualne Problemy Biomechaniki; 2014, 8; 57-62
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Validation of the Polish language version of the SF-36 Health Survey in patients suffering from lumbar spinal stenosis
Autorzy:
Klosinski, M.
Tomaszewski, K.A.
Tomaszewska, I.M.
Klosinski, P.
Skrzat, J.
Walocha, J.A.
Powiązania:
https://bibliotekanauki.pl/articles/51758.pdf
Data publikacji:
2014
Wydawca:
Instytut Medycyny Wsi
Źródło:
Annals of Agricultural and Environmental Medicine; 2014, 21, 4
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
O racjonalnych wymaganiach wobec betonów do fundamentów głębokich
On rational requirements for concrete used in foundations
Autorzy:
Kłosiński, B.
Kamiński, P.
Powiązania:
https://bibliotekanauki.pl/articles/953631.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Komunikacji Rzeczpospolitej Polskiej
Tematy:
mieszanka betonowa
betony "fundamentowe"
wymagania
norma EN 206:2013
concrete mix
"foundation" concrete
requirements
standard EN 206:2013
Opis:
Mieszanka betonowa w palach lub ścianach szczelinowych jest układana pod zawiesiną bentonitową i nie jest zagęszczana Powinna spełniać specjalne wymagania, wynikające z technologii, odmienne niż w innych konstrukcjach. Nie mogą być stosowane wymagania dotyczące tzw. betonów mostowych. Nowa wersja normy EN 206:2013 „Beton – Wymagania, właściwości, produkcja i zgodność” zawiera Załącznik D (normatywny) „Wymagania dodatkowe dotyczące specyfikacji i zgodności betonu do specjalnych robót geotechnicznych” regulujący właściwości betonów do robót fundamentowych. Są one w sprzeczności z Rozporządzeniem z 2000 r. w sprawie warunków technicznych jakim powinny odpowiadać drogowe obiekty inżynierskie, które podaje nieracjonalne wymagania. Jest ono przestarzałe i wymaga aktualizacji.
Concrete mixes used for piles and diaphragm walls are cast in a bentonite slurry and are not compacted. It should fulfill special requirements, different then in other structures. The new standard EN 206:2013 includes an Annex D “Additional requirements for specification and conformity of concrete for special geotechnical works” It is in contradiction with the decree of Ministry of Transport of 2000, which needs to be updated.
Źródło:
Drogownictwo; 2014, 10; 327-331
0012-6357
Pojawia się w:
Drogownictwo
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie i analiza właściwości elektrycznych stanowiska do wysokonapięciowych prób izolacji
Research and analysis of electrical properties of laboratory station for high-voltage tests of insulation
Autorzy:
Kłosiński, R.
Chulist, P.
Powiązania:
https://bibliotekanauki.pl/articles/267215.pdf
Data publikacji:
2017
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
badanie
sprzęt elektroizolacyjny
analiza widmowa
charakterystyki częstotliwościowe
ferrorezonans prądów
electro-insulating equipment
testing
spectral analysis
frequency response
ferroresonance of currents
Opis:
Artykuł dotyczy analizy działania obwodu elektrycznego stanowiska do badania elektroizolacyjnego sprzętu ochronnego. Podczas pracy stanowiska stwierdzono, że napięcie probiercze jest znacznie odkształcone. Aby poznać przyczyny zniekształceń wykonano pomiary sygnałów napięcia i prądu w trzech miejscach obwodu. Ciągi próbek sygnałów poddano analizie widmowej i wyznaczono charakterystyki elementów układu. Analiza wyników pozwoliła stwierdzić, że przyczyną zniekształceń jest praca jednego z transformatorów w stanie nasycenia. Można zaobserwować zjawisko ferrorezonasu prądów powodujące znaczne ich zniekształcenie. Drugim zaobserwowanym niekorzystnym zjawiskiem jest rezonans napięć powodujący wzmocnienie wybranych harmonicznych.
This article deals with the analysis of the electrical circuit of the electrical insulating equipment inspection stand. The test stand consists o f two transformers, the TRS-10 regulator and the TP-60 tester. The test voltage can be adjusted from 0 to 30 KV. During the operation of the station it was found that the test voltage is significantly deformed. In order to know the causes of distortion, measurements of voltage and current signals were made at three locations of the circuit. Signal samples were subjected to spectral analysis and the characteristics of system components were designated. Analysis of the results showed that the cause of the distortion is the operation of one of the transformers in the saturation state. The signals of currents obtained for different settings of the transformer have a deformed waveform (fig. 2), typical of the ferroresonance phenomenon. The occurrence of this phenomenon confirms the course of the characteristic (Fig. 4). The second observed unfavorable phenomenon is resonance of voltages in the high voltage circuit, resulting in the strengthening of selected harmonics of voltage. This phenomenon can be observed on the basis of the shape of frequency characteristics of the loaded test transformer TP-60 (Fig. 6).
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2017, 54; 123-126
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
ILUSTROWANA encyklopedia współczesnego lotnictwa.
Powiązania:
Nowa Technika Wojskowa 1996, nr 1 ->
Współwytwórcy:
Cebulok, Piotr. Autor
Kłosiński P. Autor
Data publikacji:
1996
Tematy:
F-16 AB Fighting Falcon (samolot) budowa i wykorzystanie Stany Zjednoczone
McDonnell Douglas MD-520 N, śmigłowiec budowa i wykorzystanie Stany Zjednoczone
Samoloty wojskowe budowa i wykorzystanie
Śmigłowce wojskowe budowa i wykorzystanie Stany Zjednoczone
Opis:
[1]:; General Dynamics F-16 A/B Fighting Falcon; Piotr Cebulok; nr 1, s. 27-28; nr 2, s. 29-30.
[2]:; [Śmigłowce] McDonnell Douglas MD-520 N [USA]; P. Kłosiński; nr 3; s. 29-30.
Il.
Dostawca treści:
Bibliografia CBW
Artykuł
Tytuł:
Urządzenia pomiarowe wykorzystywane w dydaktycznych stanowiskach laboratoryjnych
Measuring devices used in didactic stands
Autorzy:
Maślanka, K.
Rękawek, P.
Janusz, J.
Kłosiński, J.
Powiązania:
https://bibliotekanauki.pl/articles/154211.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomiar położenia
wahadło odwrócone
enkoder obrotowy
czujnik odbiciowy
displacement measurements
inverted pendulum
rotary encoder
proximity switch
control systems
Opis:
W pracy zaprezentowano urządzenia pomiarowe zainstalowane w dwu stanowiskach do badania zachowania wybranych układów regulacji położenia. Są to: stanowisko wahadła odwróconego umieszczonego na ruchomej platformie poruszającej się po poziomych prowadnicach oraz stanowisko równoważni utrzymującej kulkę w wybranej pozycji na prowadnicach, które mogą wykonywać ruch obrotowy względem osi poziomej. Obydwa obiekty regulacji są strukturalnie niestabilne i wymagają doboru regulatorów o odpowiednio dobranych nastawach. Stanowiska wykonano i przetestowano. Wyniki badań eksperymentalnych przeprowadzonych w trakcie testów stanowisk przedstawiono w postaci charakterystyk czasowych, również zamieszczono zauważone uwagi eksploatacyjne. Poza tym w pracy umieszczono również schemat układu elektrycznego enkodera oraz okna programu wizualizacyjnego obsługującego układy regulacji przemieszczenia w stanowiskach. Stanowiska były prezentowane na kilku prestiżowych prezentacjach i konkursach ciesząc się dużym zainteresowaniem i bardzo dobrą oceną komisji konkursowych. Mogą być wykorzystane zarówno w działalności dydaktycznej jak i pracach naukowych dotyczących sterowania obiektami strukturalnie niestabilnymi.
The measuring devices used in two stands for testing selected displacement control systems are described in the paper. The stands are: the stand of inverted pendulum located on a movable platform – the platform can move on horizontal guides, and the stand with a balancing beam ensuring the stabilization of the ball in a selected position on rail guides – the beam can rotate in regard to the horizontal axis. Both controlled objects are structurally unstable and require the use of controllers with specially selected parameters. The stands have been built and tested. The results of experimental tests shown in the form of time characteristics as well as the remarks concerning stands exploitation of the stands are presented. Moreover, the electric scheme of the encoder system and the computer interface windows of the monitoring programs used for controlling the displacement control systems are contained in the paper. The stands were presented on several prestigious presentations and competitions with a very good estimate of the competitive commission. They can be used in didactic activity as well as in research works concerning control of structurally instable objects.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 8, 8; 556-559
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies