Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Kłaczyński, Krzysztof" wg kryterium: Autor


Wyświetlanie 1-4 z 4
Tytuł:
On estimation of parameter functions in a weakly singular linear model with linear inequality restrictions
Autorzy:
Kłaczyński, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/748076.pdf
Data publikacji:
1994
Wydawca:
Polskie Towarzystwo Matematyczne
Tematy:
Linear regression
Applications of mathematical programming
Opis:
.
In this paper, the problem of ICGLS (Inequality Constrained Generalized Least Squares) estimation of a given set function K in the weakly singular model M={y, X| A > b, ^2V} is considered. The ICGLS estimator is not linear and it is expressed in a form of at most of 2^m formulae, where m denotes a number of rows in the matrix A. For a given vector y the one of these formulae can be used. On the basis of the Kuhn-Tucker optimality conditions, necessary and sufficient conditions for a vector Kβ^t to be the ICGLS estimator of Kβ are presented. The estimators are given in explicit form.
Źródło:
Mathematica Applicanda; 1994, 23, 37
1730-2668
2299-4009
Pojawia się w:
Mathematica Applicanda
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Consistency examination of linear inequality system
Autorzy:
Brzeskwiniewicz, Henryk
Kłaczyński, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/747539.pdf
Data publikacji:
1997
Wydawca:
Polskie Towarzystwo Matematyczne
Tematy:
Linear inequalities
Opis:
.
An investigation of the consistency of a linear inequality system is considered. It is proven that the system of linear inequalities Ax≥b is consistent if and only if for any generalized inverse A− of a matrix A the system of equations (I−AA−)v=−(I−AA−)b has a nonnegative solution for the vector v. Consistency of the above system does not depend on the choice of the matrix A−. The paper also presents methods for investigating the existence of nonnegative solutions of systems of linear equations.
Źródło:
Mathematica Applicanda; 1997, 26, 40
1730-2668
2299-4009
Pojawia się w:
Mathematica Applicanda
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The estimation of parameters in a one-dimensional linear model with restrictions
Autorzy:
Kala, Radosław
Kłaczyński, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/747623.pdf
Data publikacji:
1985
Wydawca:
Polskie Towarzystwo Matematyczne
Tematy:
Linear regression
Estimation and detection
Opis:
Artykuł nie zawiera streszczenia
The article contains no abstract
Źródło:
Mathematica Applicanda; 1985, 12, 24
1730-2668
2299-4009
Pojawia się w:
Mathematica Applicanda
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hearing tester - mobile application for hearing loss screening
Tester słuchu - mobilna aplikacja do przesiewowych badań utraty słuchu
Autorzy:
Krzyżek, Krzysztof
Kłaczyński, Maciej
Powiązania:
https://bibliotekanauki.pl/articles/328640.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
hearing screening
hearing test
hearing loss
hearing impairment
vibroacoustic diagnostics
badanie przesiewowe słuchu
utrata słuchu
upośledzenie słuchu
diagnostyka wibroakustyczna
Opis:
The article presents results of the work on creation of an application for Android mobile devices to perform hearing screening using pure-tone air conduction audiometry. The application was created in accordance with the procedure defined in the ISO 8253-1: 2010 standard and is to serve the widest possible group of people in a domestic environment, using headphones included with mobile devices. The effectiveness of the application was verified by performing comparative hearing tests on a representative group of patients with different hearing status. Validation was performed using the Interacoustics AD629 clinical audiometer and procedures adopted in the standards. The results of the test comparison were satisfactory. The mean error of the hearing threshold tested using the mobile application, compared to the clinical audiometer was 5.2 dBHL. In addition, the hearing threshold curves for the mobile application are similar in shape to the hearing thresholds for the clinical audiometer and coincide with the auditory experiences of the patients.
Artykuł przedstawia wyniki prac nad stworzeniem aplikacji na urządzenia mobilne z systemem Android w celu wykonania przesiewowych badań słuchu w zakresie progowej audiometrii tonalnej przy przewodnictwie powietrznym. Aplikacja została stworzona zgodnie z procedurą określoną w normie ISO 8253-1:2010 i ma służyć jak najszerszej grupie osób w domowych warunkach badań przy wykorzystaniu słuchawek dedykowanych urządzeniom mobilnym. Działanie aplikacji zostało zweryfikowane poprzez wykonanie porównawczych badań słuchu na reprezentatywnej grupie pacjentów o zróżnicowanym stanie słuchu. Walidację przeprowadzono przy użyciu audiometru klinicznego Interacoustics AD629 i procedur przyjętych w normach. Wyniki badań porównawczych okazały się zadowalające. Średni błąd zbadanego progu słyszenia przy pomocy aplikacji mobilnej, w porównaniu do badań przeprowadzonych przy pomocy audiometru klinicznego, wyniósł 5.2 dBHL. Dodatkowo, krzywe progu słyszenia dla aplikacji mobilnej są zbliżone w kształcie do krzywych progu słyszenia dla audiometru klinicznego i pokrywają się z wrażeniami słuchowymi pacjentów.
Źródło:
Diagnostyka; 2019, 20, 3; 87-95
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies