Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Kędra, R." wg kryterium: Autor


Wyświetlanie 1-9 z 9
Tytuł:
Preload monitoring in a bolted joint using Lamb wave energy
Autorzy:
Kędra, R.
Rucka, M.
Powiązania:
https://bibliotekanauki.pl/articles/201172.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Lamb waves
steel structures
bolted joints
non-destructive testing
structural health monitoring
Opis:
The knowledge of the load in prestressed bolted connections is essential for the proper operation and safety of engineering structures. Recently, bolted joints have become an area of intensive research associated with non-destructive diagnostics, in particular in the context of wave propagation techniques. In this paper, a novel procedure of bolt load estimation based on the energy of Lamb wave signals was proposed. Experimental tests were performed on a single lap joint of two steel plates. Ultrasonic waves were excited and registered by means of piezo-electric transducers, while precise measurement of the bolt load was obtained by means of using the force washer transducer. Experimental tests were supported by the finite element method analysis based on Schoenberg’s concept. The results showed that the relationship between the bolt load and signal energy was strongly nonlinear and it depended on the location of acquisition points.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2019, 67, 6; 1161-1169
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostics of bolted lap joint using guided wave propagation
Diagnostyka zakładkowego połączenia śrubowego z użyciem propagacji fal prowadzonych
Autorzy:
Kędra, R.
Rucka, M.
Powiązania:
https://bibliotekanauki.pl/articles/329436.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
elastic waves
non-destructive testing
bolted lap joint
finite element method
fala sprężysta
diagnostyka nieniszcząca
połączenie śrubowe
metoda elementów skończonych
Opis:
The paper presents numerical and experimental analyses of elastic waves propagation in a bolted lap joint. In experimental investigations condition assessment of the joint was performed with the use of symmetric waves excited by a piezoactuator. Numerical calculations were conducted in commercial finite element method software Abaqus. The influence of number of bolts and the value of the initial stress on recorded signals was examined. The study showed the possibility of using elastic waves in the context of diagnostics of bolted joints.
Praca przedstawia numeryczne i eksperymentalne analizy propagacji fal sprężystych w zakładkowym połączeniu śrubowym. W badaniach eksperymentalnych wykorzystano fale wzbudzane w płaszczyźnie połączenia za pomocą piezoaktuatora. Obliczenia numeryczne wykonano w środowisku komercyjnego programu metody elementów skończonych Abaqus. W badaniach analizowano wpływ liczby śrub i wartości momentu dokręcającego na zarejestrowane sygnały. Wykazano możliwość zastosowania fal sprężystych do diagnostyki połączeń.
Źródło:
Diagnostyka; 2014, 15, 4; 35-40
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelling of Mechanical Behaviour of High-Frequency Piezoelectric Actuators Using Bouc-Wen Model
Autorzy:
Kędra, R.
Rucka, M.
Powiązania:
https://bibliotekanauki.pl/articles/221301.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
piezoelectric actuators
Bouc-Wen model
parameters identification
Opis:
The paper presents application of a modified, symmetrical Bouc-Wen model to simulate the mechanical behaviour of high-frequency piezoelectric actuators (PAs). In order to identify parameters of the model, a two-step algorithm was developed. In its first stage, the mechanical parameters were identified by taking into account their bilinear variability and using a square input voltage waveform. In the second step, the hysteresis parameters were determined based on a periodic excitation. Additionally, in order to reduce the influence of measurement errors in determination of selected derivatives the continuum wavelet transform (CWT) and translation-rotation transformation (TRT) methods were applied. The results proved that the modified symmetrical Bouc-Wen model is able to describe the mechanical behaviour of PAs across a wide frequency range.
Źródło:
Metrology and Measurement Systems; 2017, 24, 2; 413-424
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numeryczna i doświadczalna analiza propagacji fal sprężystych przez stalowe połączenie śrubowe
A study on propagation of elastic waves in steel bolted joints
Autorzy:
Rucka, M.
Kędra, R.
Powiązania:
https://bibliotekanauki.pl/articles/391218.pdf
Data publikacji:
2014
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
propagacja fal sprężystych
węzły konstrukcji stalowych
połączenia śrubowe
modelowanie MES
badania doświadczalne
wave propagation
nodes of steel structures
bolted joints
FEM calculations
experimental investigations
Opis:
W pracy przedstawiono numeryczną i doświadczalną analizę propagacji fal sprężystych w połączeniu śrubowym dwóch blach stalowych. Obliczenia numeryczne metodą elementów skończonych przeprowadzono dwuetapowo. W pierwszej fazie analizowano statyczny wpływ sił sprężających na stan odkształceń i naprężeń połączenia śrubowego, formułując warunki kontaktu zastosowane następnie w modelu dynamicznym. W analizie propagacji fal sprawdzono wpływ naprężeń wstępnych na rezultaty obliczeń. Porównawcze badania doświadczalne wykonano przy wykorzystaniu wzbudnika piezoelektrycznego oraz wibrometru laserowego.
The paper presents experimental and numerical analysis of elastic waves propagation in bolted connection of two steel plates. Numerical calculations were carried out using finite element method in two stages. In the first stage, static behavior of the joint during bolts compression was analyzed. Results of static analysis were used to formulate contact conditions for dynamic models. The analysis of wave propagation was taken for four types of bolt connection model. Finally, experimental tests by using a laser vibrometer and piezoelectric actuator were made in order to validate finite element models.
Źródło:
Budownictwo i Architektura; 2014, 13, 2; 299-306
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Aplication of guided wave propagation in diagnostics of steel bridge components
Autorzy:
Rucka, M.
Zima, B.
Kędra, R.
Powiązania:
https://bibliotekanauki.pl/articles/230884.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
badanie nieniszczące
wykrywanie uszkodzenia
ocena stanu
propagacja fali
fala kierowana
most stalowy
non-destructive testing
damage detection
condition assessment
wave propagation
guided wave
steel bridge
Opis:
Early detection of potential defects and identification of their location are necessary to ensure safe, reliable and long-term use of engineering structures. Non-destructive diagnostic tests based on guided wave propagation are becoming more popular because of the possibility to inspect large areas during a single measurement with a small number of sensors. The aim of this study is the application of guided wave propagation in non-destructive diagnostics of steel bridges. The paper contains results of numerical analyses for a typical railway bridge. The ability of damage detection using guided Lamb waves was demonstrated on the example of a part of a plate girder as well as a bolted connection. In addition, laboratory tests were performed to investigate the practical application of wave propagation for a steel plate and a prestressed bolted joint.
Źródło:
Archives of Civil Engineering; 2014, 60, 4; 493-515
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Laboratory Load Model Based on 150 kVA Power Frequency Converter and Simulink Real-Time – Concept, Implementation, Experiments
Laboratoryjny model odbioru oparty na przekształtniku częstotliwości o mocy 150 kVA i platformie Simulink Real-Time – koncepcja, realizacja, badania eksperymentalne
Autorzy:
Małkowski, R.
Kędra, B.
Powiązania:
https://bibliotekanauki.pl/articles/397357.pdf
Data publikacji:
2016
Wydawca:
ENERGA
Tematy:
power converter
Simulink Real-Time
MATLAB
load
tap controller
przekształtnik mocy
Matlab
obciążenie
regulator zaczepów
Opis:
First section of the paper provides technical specification of laboratory load model basing on 150 kVA power frequency converter and Simulink Real-Time platform. Assumptions, as well as control algorithm structure is presented. Theoretical considerations based on criteria which load types may be simulated using discussed laboratory setup, are described. As described model contains transformer with thyristor-controlled tap changer, wider scope of device capabilities is presented. Paper lists and describes tunable parameters, both: tunable during device operation and changed only before starting the experiment. Implementation details are given in second section of paper. Hardware structure is presented and described. Information about used communication interface, data maintenance and storage solution, as well as used Simulink real-time features are presented. List and description of all measurements is provided. Potential of laboratory setup modifications is evaluated. Third section describes performed laboratory tests. Different load configurations are described and experimental results are presented. This includes simulation of under frequency load shedding, frequency and voltage dependent characteristics of groups of load units, time characteristics of group of different load units in a chosen area and arbitrary active and reactive power regulation basing on defined schedule. Different operation modes of control algorithm are described: apparent power control, active and reactive power control, active and reactive current RMS value control.
W artykule opisano koncepcję oraz sposób realizacji laboratoryjnego modelu odbioru o mocy 150 kVA. Odbiornik zaprojektowano w taki sposób, aby umożliwić emulację zmienności mocy dowolnego odbioru. Integralnym elementem modelu jest transformator z energoelektronicznym przełącznikiem zaczepów. W pierwszej części artykułu przedstawiono założenia, strukturę przyjętego algorytmu sterowania, wymieniono i opisano podstawowe wielkości wejściowe i wyjściowe, a także wybrane wielkości parametryzujące. W drugiej części artykułu opisano strukturę sprzętową. Podano informacje o zastosowanym interfejsie komunikacyjnym, na temat sposobu zbierania i archiwizacji danych oraz wybranych funkcjonalności wykorzystywanego narzędzia, jakim jest Simulink Real-Time. W części trzeciej zaprezentowano przykładowe wyniki prób eksperymentalnych potwierdzające słuszność przyjętej koncepcji sterowania. Zamieszczone przykłady pokazują m.in. możliwości kształtowania zmienności mocy odbioru, skuteczności działania energoelektronicznego przełącznika zaczepów, czy wreszcie efekt działania zaimplementowanego algorytmu automatyki samoczynnego podczęstotliwościowego odciążenia.
Źródło:
Acta Energetica; 2016, 3; 94-101
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Laboratoryjny model odbiornika dużej mocy. Koncepcja, wykonanie, eksperymenty
Laboratory large power load model. Concept, implementation, experiments
Autorzy:
Kędra, B.
Małkowski, R.
Powiązania:
https://bibliotekanauki.pl/articles/268999.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
przekształtniki mocy
simulink Real-Time
Matlab
model odbioru
power converter
simulink real-time
MATLAB
load
tap controller
Opis:
W referacie przedstawiono koncepcję oraz sposób realizacji laboratoryjnego modelu odbioru o mocy 150 kVA. Odbiornik zaprojektowano w taki sposób aby umożliwić emulację zmienności mocy dowolnego odbiorcy, jak również pracę transformatora zasilającego takiego odbiorcę. W referacie zaprezentowano też przykładowe wyniki prób eksperymentalnych potwierdzające słuszność przyjętej koncepcji sterowania.
First section of the paper provides concept of laboratory load model basing on 150 kVA power frequency converter and Simulink Real-Time platform. Assumptions, as well as control algorithm structure is presented. Theoretical considerations based on criteria which load types may be simulated using discussed laboratory setup, are described. Implementation details are given in second section of paper. Hardware structure is presented and described. Information about used communication interface, data maintenance and storage solution, as well as used Simulink real-time features are presented. Third section describes performed laboratory tests and their results.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 42; 215-218
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hiatus hernia – Late complication after gastrectomy followed by double tract reconstruction (DTR): a case report
Autorzy:
Bandurski, R.
Gryko, M.
Dawidziuk, T.
Zaręba, K.
Cepowicz, D.
Kędra, B.
Powiązania:
https://bibliotekanauki.pl/articles/1916509.pdf
Data publikacji:
2014
Wydawca:
Uniwersytet Medyczny w Białymstoku
Tematy:
gastric cancer
hiatus hernia
late complication
surgery
Opis:
In patients with dyspeptic symptoms who have been treated for gastric cancer, other medical conditions apart from cancer recurrence should be considered. A long small-bowel loop left after esophagogastric anastomosis, flaccid diaphragmatic crura, and several external factors such as hard physical exertion can promote the development of postoperative hiatus hernia. The authors of this paper present a rare case of hiatus hernia considered a late complication of primary surgery performed due to gastric cancer. The 63-year-old patient had undergone total gastrectomy with double tract reconstruction (DTR) six years earlier. Gastrectomy was performed with extended lymphadenectomy (>D2). Histopathologic examination of tumor specimens showed mucinous adenocarcinoma with no lymph node metastasis and no distant metastases (pathologic staging: pT2, pN0, pM0). After six years, the patient was admitted to the 2nd Department of General and Gastroenterologic Surgery with abdominal pains, malaise, weight loss and feeling of fullness after small meals. Diagnostic procedures performed showed the presence of hiatus hernia, a very rare complication after this particular surgery, with no features of cancer recurrence. The patient was underwent surgery and the hernia was successfully repaired.
Źródło:
Progress in Health Sciences; 2014, 4, 1; 265-268
2083-1617
Pojawia się w:
Progress in Health Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Studying of Perovskite Nanoparticles in PMMA Matrix Used as Light Converter for Silicon Solar Cell
Autorzy:
Lipiński, M.
Socha, R. P.
Kędra, A.
Gawlińska, K.
Kulesza-Matlak, G.
Major, Ł.
Drabczyk, K.
Łaba, K.
Starowicz, Z.
Gwóźdź, K.
Góral, A.
Popko, E.
Powiązania:
https://bibliotekanauki.pl/articles/356850.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
perovskite nanoparticles
light converters
solar cells
solar energy materials
Opis:
The nanoparticles of CH3NH3PbBr3 hybrid perovskites were synthesized. These perovskite nanoparticles we embedded in polymethyl methacrylate (PMMA) in order to obtain the composite, which we used as light converter for silicon solar cells. It was shown that the composite emit the light with the intensity maximum at about 527 nm when exited by a short wavelength (300÷450 nm) of light. The silicon solar cells were used to examine the effect of down-conversion (DC) process by perovskite nanoparticles embedded in PMMA. For experiments, two groups of monocrystalline silicon solar cells were used. The first one included the solar cells without surface texturization and antireflection coating. The second one included the commercial cells with surface texturization and antireflection coating. In every series of the cells one part of the cells were covered by composite (CH3NH3PbBr3 in PMMA) layer and second part of cells by pure PMMA for comparison. It was shown that External Quantum Efficiency EQE of the photovoltaic cells covered by composite (CH3NH3PbBr3 in PMMA) layer was improved in both group of the cells but unfortunately the Internal Quantum Efficiency was reduced. This reduction was caused by high absorption of the short wavelength light and reabsorption of the luminescence light. Therefore, the CH3NH3PbBr3 perovskite nanoparticles embedded in PMMA matrix were unable to increase silicon solar cell efficiency in the tested systems.
Źródło:
Archives of Metallurgy and Materials; 2017, 62, 3; 1733-1739
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-9 z 9

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies