Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Juszczyk, Z." wg kryterium: Autor


Wyświetlanie 1-8 z 8
Tytuł:
Subclavian steal syndrome in a patient with dizziness, left upper arm paresthesia, and exercise-related syncope-a case report
Autorzy:
Stankala, S.
Halski, T.
Kucharski, W.
Skowron, W.
Juszczyk, Z.
Płotnik, R.
Powiązania:
https://bibliotekanauki.pl/articles/2087745.pdf
Data publikacji:
2020
Wydawca:
Uniwersytet Opolski. Instytut Nauk o Zdrowiu
Tematy:
subclavian steal syndrome
dizziness
paresthesia
Opis:
Background: Dizziness, numbness, and paresthesia of upper limbs are common symptoms in patients who undergo physiotherapy. Most of the symptoms are caused by neurological and skeletomuscular diseases. Subclavian steal syndrome is a rare case of such symptoms. Aim of the study: This study aimed to analyze how to proceed with symptomatic patients suspected of subclavian steal syndrome. Material and methods: Medical documentation was used. Case report: A 69-year-old patient, long term cigarette smoker, with the anamnesis of spine surgery due to discopathy, atherosclerosis of the lower extremities, and hypertension was referred to our hospital due to exacerbation of coronary artery disease. During his stay in the cardiac department, after smoking a cigarette, he felt pain and numbness in his left arm. He began intense movement of this hand, and then lost consciousness. A difference in pulse filling and blood pressure between the upper extremities was noted. In a duplex Doppler study, reversal flow in the left vertebral artery due to stenosis of the left subclavian artery was found. Angio-CT of the head vessels confirmed a significant stenosis of the proximal left subclavian artery. The patient was referred for further treatment to a Vascular Surgery Clinic. Conclusions: The subclavian steal syndrome is a rare cause of dizziness and paresthesia of the upper extremities. Physiotherapy procedures on the affected limb can exacerbate neurological symptoms. It is easy to identify the disease based on differences in pulse amplitude and blood pressure between upper limbs. Diagnosis should be established before proceeding with physiotherapy, due to the fact that some procedures can worsen the patient’s condition.
Źródło:
Medical Science Pulse; 2020, 14, 3; 73-77
2544-1558
2544-1620
Pojawia się w:
Medical Science Pulse
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Autonomiczny system monitorowania parametrów pracy baterii ogniw ołowiowych
Autonomous system for monitoring lead-acid battery parameters
Autorzy:
Polnik, B.
Kurpiel, W.
Juszczyk, Z.
Powiązania:
https://bibliotekanauki.pl/articles/199268.pdf
Data publikacji:
2017
Wydawca:
Instytut Techniki Górniczej KOMAG
Tematy:
górnictwo
elektrotechnika
zasilanie akumulatorowe
bezpieczeństwo
mining
electro technical
battery supply
safety
Opis:
Górnicze maszyny zasilane są często z akumulatorów składających się z ogniw kwasowo-ołowiowych. Ogniwa te w czasie ładowania bądź doładowywania wydzielają wodór, który po przekroczeniu określonych stężeń staje się gazem wybuchowym. Zagrożenie to jest znane większości użytkownikom maszyn z zasilaniem akumulatorowym, stąd ich zainteresowanie jego wyeliminowania bądź możliwie największego zminimalizowania. W artykule przedstawiono wyniki badań stężenia gazu elektrolitycznego – wodoru wewnątrz skrzyni akumulatorowej, w trakcie pracy górniczej lokomotywy akumulatorowej z rekuperacją energii w czasie hamowania elektrycznego, jak również podczas ładowania baterii ogniw w komorze ładowania w kopalni. Zaproponowano rozwiązanie poprawiające bezpieczeństwo eksploatacji maszyn zasilanych z baterii ogniw ołowiowych w postaci autonomicznego systemu monitorowania parametrów baterii ogniw ołowiowych. Omówiono jego budowę oraz zasadę działania. Wskazano zalety jakie będzie mógł uzyskać użytkownik poprzez zastosowanie opracowanego systemu.
Mining machines are often powered by batteries consisting of lead-acid batteries. These cells release hydrogen when they are loaded or recharged, which, after exceeding certain concentrations, becomes explosive gas. This danger is most of the users of machines with battery power known, hence their interest in eliminating it or minimizing it as much as possible. The paper presents the results of investigations of the concentration of electrolytic gas - hydrogen inside the battery box, during the mining operation of the battery locomotive with energy recuperation during electrical braking as well as during charging the cells in the charging chamber in the mine. A solution has been proposed to improve the operational safety of lead-powered batteries in the form of an autonomous system for monitoring lead battery batteries. It discusses its construction and principle of operation. The benefits of using the developed system can be identified by the user.
Źródło:
Maszyny Górnicze; 2017, 35, 3; 58-64
0209-3693
2450-9442
Pojawia się w:
Maszyny Górnicze
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metastatic and non-metastatic sentinel inguinofemoral lymph nodes in vulvar cancer show an increased lymphangiogenesis
Autorzy:
Piechowicz, M.
Mikos, M.
Banas, T.
Okon, K.
Pietrus, M.
Balajewicz-Nowak, M.
Szczudlik, L.
Kojs, Z.
Czerw, A.
Juszczyk, G.
Pityński, K.
Powiązania:
https://bibliotekanauki.pl/articles/2085422.pdf
Data publikacji:
2020
Wydawca:
Instytut Medycyny Wsi
Tematy:
anti-D2–40 antibody
lymphatic vessel density
immunohistochemistry
sentinel lymph node
vulvar cancer
Opis:
Introduction and objective. Lymph node involvement is a strong predictor of disease recurrence and patient survival in vulvar cancer. The aim of the study was to evaluate the feasibility of sentinel lymph node (SLN) screening, the incidence of skip metastases, and lymph node lymphangiogenesis. Materials and method. Fifty-five patients participated in this prospective, single centre study. A double SLN screening method was employed using radiocolloid (technetium-99 sulfur colloid) and 1.0% Isosulfan Blue. Immunohistochemistry, using a mouse monoclonal antibody against D2–40, was used to evaluate lymphatic vessel density (LVD). All calculations were performed using STATISTICA software v. 10 (StatSoft, USA, 2011); p<0.05 was considered significant. Results. Using both methods of SLN detection, 100% accuracy was achieved, and skip metastases were diagnosed in only one woman (1.82%). Peri-tumour median LVD was significantly increased compared with matched intra-tumour samples (p<0.001), while median LVD was significantly lower in negative, compared with positive SLN, regardless of whether matched non-SLN were negative (p<0.001) or positive (p=0.005). Metastatic SLN exhibited significantly higher median LVD compared with matched negative non-SLN (p=0.015), while no significant difference in median LVD was detected between positive SLN and matched positive non-SLN. However, negative SLN had a significantly higher median LVD compared with matched negative non-SLN (p = 0.012). Conclusions. SLN detection is a safe and feasible procedure in vulvar cancer. In patients without nodular involvement, SLN, compared with non-SLN, exhibited significantly higher median LVD, which may be an indication of its preparation to host metastases, and thus requires further investigation.
Źródło:
Annals of Agricultural and Environmental Medicine; 2020, 27, 1; 123-128
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sulphur hexafluoride as a high-voltage insulation - selected problems
Autorzy:
Opydo, W.
Juszczyk, Z.
Stawicki, J.
Opydo-Szymaczek, J.
Powiązania:
https://bibliotekanauki.pl/articles/97179.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
high-voltage insulation
electric strength
sulphur hexafluoride (SF6)
toxic byproducts
Opis:
The paper presents some selected properties of sulphur hexafluoride (SF6) a medium used for high-voltage insulation and electric arc suppression purposes. The results are presented of the studies aimed at determining the effect of the electrode material type, temperature, gas density and interelectrode gap on the SF6 electric strength. The considered systems had both flat electrodes or one flat and the other (cathode) having the form of a rod of 3 mm or 30 mm diameter, ended with a hemisphere. The electrodes have been made of stainless steel or aluminum. The results were mathematically processed with the use of the Statistica [11] computer software. It was found that SF6 temperature changes in the range from 243 K to 293 K with constant SF6 density did not cause variation of electric strength of the gas. Moreover, the effect of the electrode material type on electric strength of SF6 was observed only in the systems distinguished by macroscopic uniformity of the electric field and in case of the gas density exceeding 15 kg/m3, corresponding to SF6 pressure amounting about to 2.5-105 Pa in the temperature 293 K. Physical interpretation of the study results is proposed and formulated. Additionally, the paper discusses the hazards arising from the use of SF6 for the health of the persons operating the equipment and for the environment.
Źródło:
Computer Applications in Electrical Engineering; 2014, 12; 206-216
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ rodzaju materiału elektrod, temperatury i gęstości sześciofluorku siarki na jego wytrzymałość elektryczną
Effect of electrode material, temperature and sulfur hexafluoride density on its electric strength
Autorzy:
Opydo, W.
Juszczyk, Z.
Powiązania:
https://bibliotekanauki.pl/articles/377326.pdf
Data publikacji:
2014
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
sześciofluorek siarki
inicjowanie przeskoku
wytrzymałość elektryczna
Opis:
W pracy przedstawiono wyniki badań wpływu na wytrzymałość elektryczną SF6 przy napięciu stałym: rodzaju materiału elektrod, temperatury, gęstości gazu oraz odstępu elektrod. Badane układy miały obydwie elektrody płaskie bądź jedną elektrodę płaską, a drugą (katodę) w kształcie pręta o średnicy 3 lub 30 mm, zakończonego półkulą. Elektrody były wykonane ze stali nierdzewnej lub aluminium. Stwierdzono, że zmiany temperatury SF6 w zakresie od 243 K do 293 K, przy stałej gęstości SF6, nie powodowały zmian wytrzymałości elektrycznej gazu. Ponadto, wpływ rodzaju materiału elektrod na wytrzymałość elektryczną SF6 występował tylko w układach z polem elektrycznym jednostajnym makroskopowo i pojawiał się ze wzrostem gęstości gazu powyżej 15 kg/m3, co odpowiada ciśnieniu SF6 około 2,5 105 Pa przy temperaturze 293 K. Do opracowania matematycznego wyników badań wykorzystano program komputerowy Statistica [4].
The paper presents results of the study on the effects of electrode material, temperature, gas density and electrode separation on SF6 electric strength under constant voltage. Tested systems consisted of two plane electrodes or one plane electrode and the second one (cathode) rod-shaped, 3 or 30 mm diameter, tipped with hemisphere. Electrodes were made of stainless-steel or aluminum. The results revealed that SF6 temperature variations within the range of 243 K to 293 K, under stable SF6 density, did not result in changes of electric strength of the gas. Moreover, effect of electrode material on SF6 electric strength was observed only in systems with macroscopically uniform field and appeared with the increasing density of gas in system, exceeding 15 kg/m3, which corresponds to SF6 pressure of approximately 2,5 105 Pa, at the temperature of 293 K. Statistica [3] software was used for mathematical analysis of the results.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2014, 78; 175-183
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fault detection and isolation for power electronic systems featuring parameter uncertainty
Detekcja i lokalizacja uszkodzeń układu energoelektronicznego zawierającego niedokładnie określone parametry
Autorzy:
Juszczyk, W.
Kich, Z.R.
Zając, M.
Powiązania:
https://bibliotekanauki.pl/articles/159700.pdf
Data publikacji:
2003
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
system diagnostyczny
układy energoelektroniczne
Opis:
An assumption was made in this paper that monitoring both the converter and its control means actually continuous formulation (i.e. repeatedly) of diagnoses of their states automatically via a suitable computer diagnostic system. In other words it is diagnosing on-line carried out in real time. The authors assume that mainly the operating signals are used for diagnostic purposes since it is not recommendable to disturb the process with any additional test signals. This paper presents a fault detection and isolation scheme for systems with modeling uncertainties where not all the state variables are measurable. The proposed fault diagnosis architecture consists of a fault detection estimator and a set of isolation estimators. Each estimator corresponds to a specific fault type. Employing orthogonal transforms made it possible to depict the power electronics state variable in terms of appropriate linear combination of base functions, so far approximated by a time set. There were families of binary orthogonal Walsh and Haar functions used in the investigation. The presented approach may be considered a numeric-analytical method. The investigation of power electronic converter signals was carried out using fast processing algorithms.
W pracy przyjęto, że monitorowanie przekształtnika i jego sterowania jest prowadzone w sposób ciągły (cyklicznie) poprzez automatyczne formułowanie diagnoz jego stanu przez komputerowy system diagnostyczny. Innymi słowy diagnozowanie jest prowadzane w czasie rzeczywistym. Autorzy zakładali, że jako sygnały diagnostyczne użyte będą sygnały procesu, ponieważ wprowadzanie dodatkowych sygnałów testowych mogło by zakłócać jego dynamikę. Praca przedstawia układ wykrywania i lokalizacji uszkodzeń układu energoelektronicznego zawierającego niedokładnie określone parametry przy braku możliwości pomiaru wszystkich zmiennych stanu. Zaproponowana architektura diagnostyki uszkodzeń obejmuje estymator ich wykrywania oraz zbiór estymatorów lokalizacji. Każdy estymator lokalizacji odpowiada konkretnemu typowi uszkodzenia. Zastosowanie przekształceń ortogonalnych umożliwia przedstawienie zmiennej stanu układu energoelektronicznego w postaci odpowiednich kombinacji liniowej funkcji bazowych, dotychczas aproksymowanej szeregiem czasowym. W badaniach zastosowano rodziny binarnych funkcji ortogonalnych Walsha i Haara. Opisane podejście można zaliczyć do metod analityczno - numerycznych. Badanie własności sygnałów przekształtników energoelektronicznych przeprowadzono w oparciu o opracowane przez autorów algorytmy szybkich przekształceń.
Źródło:
Prace Instytutu Elektrotechniki; 2003, 218; 61-78
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fault detection in power electronics systems based on qualitative and quantitative models
Detekcja uszkodzeń w układach energoelektronicznych oparta na modelach jakościowych i ilościowych
Autorzy:
Juszczyk, W.
Kich, Z.R.
Zając, M.
Powiązania:
https://bibliotekanauki.pl/articles/158608.pdf
Data publikacji:
2002
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Opis:
It is assumed in this paper that monitoring both the converter and its control states means continuous formulation (i.e. in a repeatable way) of a diagnosis of the plant's state automatically via a suitable computer diagnostic system. In other words it is on-line diagnosing carried out in real time. The authors assume that mainly the operating signals are used for diagnostic purposes since it is not recommendable to disturb the process with any additional test signals. Implementation of the orthogonal expansion made it possible to depict the system state approximated by a sequence of its values' observations in a form of some linear combination of basic functions. Complete families of binary orthogonal Walsh and Haar functions are emploed. The employed research methods may be considered numeric-analytical ones. The investigation of the signal properties in power electronics inverters was carried out using fast processing algorithms (both in serial and parallel modes). Along with the simulational modeling the presented approach made it possible to execute a complex fault detection and isolation for a typical arrangement of the inverter. The fast transform algorithm used in this paper is based on the Haar matrix factorization.
Przyjęto, że monitorowanie stanu wybranego przekształtnika i jego układu sterowania jest powtarzalnym cyklicznie w sposób automatyczny komputerowym formułowaniem diagnoz o jego stanie. Innymi słowy jest to diagnozowanie prowadzone na bieżąco w czasie rzeczywistym. Autorzy założyli, że do celów diagnostyki układów energoelektronicznych wykorzystywane są głównie sygnały robocze, niewskazanym jest bowiem zakłócanie procesu dodatkowymi sygnałami testowymi. Przedstawione typowe schematy możliwych testów diagnostycznych używanych do oceny własności wybranych sygnałów przekształtnika, oraz sklasyfikowano spotykane w literaturze metody detekcji uszkodzeń, które mogą znaleźć zastosowanie do oceny niezawodności działania podobnych układów energoelektronicznych. Przedstawiono schemat blokowy procesu monitorowania przekształtnika. Szczególną uwagę zwrócono na przyczyny istnienia opóźnień czasowych powstawania symptomów. Sklasyfikowano czynniki od których zależą te opóźnienia. Zaproponowano formalizację opisu stanu pracy przekształtnika i opisu możliwych testów diagnostycznych. Do badań wybrano testy oparte na zastosowaniu analizy spektralnej sygnałów. Obiektem badań był typowy prostownik sterowany. Zastosowanie teorii rozwinięć ortogonalnych umożliwiło przedstawienie stanu układu aproksymowanego ciągiem obserwacji jego wartości w postaci pewnej kombinacji liniowej funkcji bazowych. W badaniach zastosowano pełne rodziny binarnych funkcji ortogonalnych Walsha i Haara. Użyty w tej pracy algorytm szybkiego przekształcenia oparto na faktoryzacji macierzy Haara. Zastosowane metody badawcze można zaliczyć do metod numeryczno-analitycznych. Badania własności sygnałów prostownika przeprowadzono w oparciu o wykorzystanie szybkich algorytmów przetwarzania (w wersjach szeregowej i równoległej). Wykazały one swą przydatność dla formułowania diagnoz o miejscach i zakresach pojawiania się typowych uszkodzeń w zasilaniu, sterowaniu czy też obciążeniu prostownika. W połączeniu z modelowaniem symulacyjnym prezentowane podejście pozwoliło na przeprowadzenie kompleksowego procesu detekcji i lokalizacji uszkodzeń dla typowego układu prostownika sterowanego.
Źródło:
Prace Instytutu Elektrotechniki; 2002, 211; 167-202
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Produkcja drożdży paszowych Yarrowia lipolytica wzbogaconych w aminokwasy selenowe i witaminę B12
Production of the Yarrowia lipolytica fodder yest enriched in selenoaminoacids and B12 vitamin
Autorzy:
Juszczyk, P.
Smolczyk, A.
Gil, Z.
Rywińska, A.
Rymowicz, W.
Powiązania:
https://bibliotekanauki.pl/articles/2073175.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
drożdże paszowe Yarrowia lipolytica
selenoaminokwasy
cyjanokobalamina
Yarrowia lipolytica
fodder yeast
selenoaminocids
cyanocobalamine
Opis:
Celem pracy było opracowanie warunków procesu produkcji drożdży paszowych Yarrowia lipolytica A-101, wzbogaconych o aminokwasy selenowe (selenometionina i selenocysteina) oraz w witaminę B12 (cyjanokobalaminę) w procesie prowadzonym w instalacji pilotowej (bioreaktory o pojemności roboczej do 2 m3). Stwierdzono, że dodatek do pożywki seleninu sodu oraz cyjanokobalaminy pozwala uzyskać drożdże paszowe o wysokiej wartości odżywczej. Stężenie selenometioniny i selenocysteiny w białku drożdży było w ilości odpowiednio 58 i 8 mg/100g białka. Ponadto, drożdże akumulowały do 12,5 µg/g witaminy B12.
The aime of this study was to determine the effect of culture conditions and medium composition on the production of biomass Yarrowia lipolytica enriched with selenoaminocides and B12 vitamin in a pilot scale (working capacity to 2 m3). The studies showed thatthe addition of sodium selenite and cyanocobalamin into the culture broth correlated with a hight nutrition level of yeast. The concentration of selenomethionine and selenocysteine in the yeast protein was equal to 58 ang 8 mg/100g of protein, respectively. Additionally, the yeast accumulated B12 vitamin up to 12,5 µg/g.
Źródło:
Inżynieria i Aparatura Chemiczna; 2015, 4; 165--166
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies