Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Jung, M." wg kryterium: Autor


Tytuł:
Semiempirical model for diagnostication Helicobacter pylori infection by use of 14C labelled urea
Autorzy:
Jung, A.
Wasilewska-Radwanska, M.
Kopanski, Z.
Powiązania:
https://bibliotekanauki.pl/articles/147046.pdf
Data publikacji:
2002
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
computing modelling
Helicobacter pylori infection
kinetics of 14C labelled urea
Opis:
The main aim of this study was to create a semiempirical model, helpful in estimating severity of the Helicobacter pylori (H. pylori) infection by using the urea breath test (UBT), when urea labelled 14C has been used for diagnostics. The model consists of four compartments representing stomach (1), blood vascular system (2), lungs (3) and urinary system (4). Mathematical model is based on the balance of radioactive 14C in compartments from 1 to 4. The histological investigations were used as reference methods. Comparison of the results obtained from simulation, which yields dependence of 14C activity on time, to experimental results of UBT, made it possible to determine the ranges of coefficient hB value, which characterized each degrees of severity of H. pylori infection: degree 0 (lack of infection) - hB below 0.025; degree 1 (not large) - hB in range 0.025-0.115; degree 2 (moderate) - hB in range 0.115-0.300; degree 3 (significant) - hB above 0.300. It was possible to estimate severity of H. pylori infection in clinical practice on the basis of comparing the 14C activity value of experimental points as obtained from the breath test, to the results of simulation with suitable value of the fitted parameter hB indicating degree of severity of infection.
Źródło:
Nukleonika; 2002, 47, 3; 95-99
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ergonomic Hand Tool and Desk and Chair Development Process
Autorzy:
Shin, D.
Kim, J. Y.
Hallbeck, M. S.
Haight, J. M.
Jung, M. C.
Powiązania:
https://bibliotekanauki.pl/articles/89795.pdf
Data publikacji:
2008
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
ergonomics process
hand tool
desk and chair
Opis:
This paper suggests a practical and simple process consisting of 8 stages: needs assessment, ergonomics guidelines, anthropometry, brainstorming and idea sketch, preliminary model, drafting and rendering, working prototype, and user trials. The feasibility of this process was verified with the development of a modified clamping hand tool and a new student desk and chair. The case studies showed how design difficulties were overcome by integrating ergonomics guidelines in the process.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2008, 14, 2; 247-252
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prevention of tick bites and protection against tick-borne diseases in South-Eastern Poland
Autorzy:
Bartosik, K
Kubrak, T.
Olszewski, T.
Jung, M.
Buczek, A.
Powiązania:
https://bibliotekanauki.pl/articles/49324.pdf
Data publikacji:
2008
Wydawca:
Instytut Medycyny Wsi
Tematy:
tick bite
tick-borne disease
borreliosis
health
tick
prevention method
prevention
human disease
European country
risk
behaviour
Źródło:
Annals of Agricultural and Environmental Medicine; 2008, 15, 2
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of undecanones and their derivatives on tumor angiogenesis and VEGF content
Autorzy:
Gibka, J
Wasiutynski, A.
Skopinska-Rozewska, E.
Siwicki, A.K.
Chorostowska-Wynimko, J.
Sommer, E.
Mazurkiewicz, M.
Glinski, M.
Skurzak, H.
Wojcik, R.
Jung, L.
Powiązania:
https://bibliotekanauki.pl/articles/31734.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
mice
mouse
undecan-x-one
derivative
angiogenesis
tumour
VEGF zob.vascular endothelial growth factor
enantiomer
histological examination
vascular endothelial growth factor
sarcoma cell
Opis:
The in vivo effects of some derivatives of aliphatic ketones (2-undecanone, 3-undecanone, 4-undecanone and their derivatives) on L-l sarcoma tumor angiogenesis and VEGF content were studied in Balb/c mice. Mice that inhaled 10% solution of 3-undecanone(3-on) or 1% solution of 2-undecanone propylene acetal (Acpr2) for 3 days after tumor cells implantation, presented lower neovascular response measured by tumor-induced cutaneous angiogenesis test (TIA) and lower tumor VEGF content in 5-days tumors, than non-inhaled controls. Other substances presented various effects on tumor VEGF concentration and angiogenesis. Histological examination of lesions collected from mice inhaled Acpr2, or non-inhaled controls, revealed small diffused areas of necrosis in the former group. In both groups, slight to moderate inflammatory infiltrations were seen at the tumor's margin. In Acpr2 group, there were less small blood vessels at tumor's margin than in the control group.
Źródło:
Polish Journal of Veterinary Sciences; 2010, 13, 1; 105-115
1505-1773
Pojawia się w:
Polish Journal of Veterinary Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Capability of Semiconducting NiO Films in Gamma Radiation Dosimetry
Autorzy:
Guziewicz, M.
Jung, W.
Grochowski, J.
Borysiewicz, M.
Golaszewska, K.
Kruszka, R.
Baranska, A.
Piotrowska, A.
Witkowski, B.
Domagala, J.
Gryzinski, M.
Tyminska, K.
Stonert, A.
Powiązania:
https://bibliotekanauki.pl/articles/1492706.pdf
Data publikacji:
2011-12
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
73.61.Jc
29.40.-n
87.53.Bn
Opis:
Electrical properties of RF magnetron sputtered p-NiO films were characterized after fabrication and after gamma irradiations using $\text{}^{137}Cs$ and $\text{}^{60}Co$ sources. Electrical parameters are obtained from the Hall measurements, impedance spectroscopy and C-V measurement of n-Si/p-NiO junction diodes. The results show that resistivity of the NiO film is gradually increased following after sequential irradiation processes because of the decrease in holes' concentration. Hole concentration of a NiO film decreases from the original value of $4.36 \times 10^{16} cm^{-3}$ to $2.86 \times 10^{16} cm^{-3}$ after $\text{}^{137}Cs γ$ irradiation with doses of 10 Gy. In the case of γ irradiation from $\text{}^{60}Co$ source, hole concentration of the film decreases from $6.3 \times 10^{16}//cm^3$ to $4.1 \times 10^{16}//cm^3$ and to $2.9 \times 10^{16}//cm^3$ after successive expositions with a dose of 20 Gy.
Źródło:
Acta Physica Polonica A; 2011, 120, 6A; A-069-A-072
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Current Distribution in Y-Ba-Cu-O Superconducting Microbridges Containing Π-Shaped Channel for Easy Vortex Motion
Autorzy:
Sulcas, J.
Steponaviciene, L.
Jukna, A.
Jung, G.
Plausinaitiene, V.
Abrutis, A.
Gong, M.
Sobolewski, R.
Powiązania:
https://bibliotekanauki.pl/articles/1505543.pdf
Data publikacji:
2011-02
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
74.78.-w
74.25.Sv
74.25.F-
74.25.Wx
Opis:
A mixed state in dc-biased thin films of II-type superconductors realizes the Abrikosov magnetic vortices/antivortices, which are the result of the current-self magnetic field penetration into the film at temperatures lower than its critical temperature $T_{c}$. A nucleation of vortices/antivortices at the superconducting film's edges, their motion perpendicular to the direction of biasing current, and the annihilation in the film's center originates from a current dissipation in the superconductor and expresses itself in experiments as a dc voltage. This work reports on the results of simulation of current density in a 50 μm wide, 100 μm long, and 0.3 μm thick $YBa_2Cu_3O_{7 - x}$ microbridges containing Π-shaped 5 μm wide single channel of easy vortex motion fabricated by means of laser-writing technique. Analyzing a two-dimensional-net of resistors and assuming that, due to the Meissner-Ochsenfeld effect, the magnetic flux penetration into superconducting film is nonlinear, we demonstrate that presence of a Π-shaped channel causes a non-homogeneous distribution of current in the microbridge.
Źródło:
Acta Physica Polonica A; 2011, 119, 2; 183-185
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation Details of Vortex Density in Laser-Written Π-Shaped Channel of YBCO Bridge by Means of I-V Dependences
Autorzy:
Steponaviciene, L.
Sulcas, J.
Jukna, A.
Jung, G.
Plausinaitiene, V.
Abrutis, A.
Maneikis, A.
Gong, M.
Sobolewski, R.
Powiązania:
https://bibliotekanauki.pl/articles/1505530.pdf
Data publikacji:
2011-02
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
74.78.-w
74.25.Sv
74.25.F-
74.25.Wx
Opis:
A current-self-induced magnetic field $H_{j}$, such that $H_{c1} < H_{j} < H_{c2}$ at $T < T_{c}$, penetrates a thin-film, type-II superconductor forming the Abrikosov magnetic vortex-antivortex pairs in the film's areas of weakest superconductivity. Our atomic force microscopy and scanning tunneling microscopy images confirm that in 50 μm wide, 100 μm long and 0.3 μm thick $YBa_2Cu_3O_{7 - x}$ superconducting devices magnetic flux penetrates first into a 5 μm wide, Π-shaped and partially deoxygenated (x ≈ 0.2) channel for easy vortex motion. When the Lorentz force overcomes pinning force in the channel, the flux starts to move and its drift dissipates energy inducing dc voltage. This work reports on the density of coherently moving vortices along the channel vs. temperature in range from $0.93T_{c}$ to $0.97T_{c}$. Our simulations show that the vortex density vs. temperature dependence extracted from I-V measurements of our devices follows the temperature dependence of magnetic field penetration depth and the coherence length of the superconductor.
Źródło:
Acta Physica Polonica A; 2011, 119, 2; 180-182
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Light Propagation in Optical Fibers with a High Step Index
Autorzy:
Jung, P.
Karpierz, M.
Powiązania:
https://bibliotekanauki.pl/articles/1417966.pdf
Data publikacji:
2012-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
42.25.Bs
42.81.-i
42.81.Qb
Opis:
Simulation of light beam propagation in optical fiber with a high step index requires the use of complicated methods. One of the simplest and accurate method is presented in this paper. The possibility of use of beam propagation method with exact boundary conditions in light beam propagation in optical fibers is shown in this work. The comparison of this method with analytical solutions for planar waveguide and optical fiber confirms usefulness of it.
Źródło:
Acta Physica Polonica A; 2012, 122, 5; 829-832
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Postural Evaluation in a Poultry Farm for Broiler Chickens
Autorzy:
Wang, H.
Kong, Y. K.
Jung, M. C.
Powiązania:
https://bibliotekanauki.pl/articles/91121.pdf
Data publikacji:
2012
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
simultaneous posture
individual posture
body posture
finger posture
Opis:
The goal of this study was to evaluate working postures in 9 operations of poultry farming for broiler chickens for 14 body segments with 4 categories, and for fingers with 14 categories. Overall, the farmers commonly bent almost all their body segments and used power grips. The operations of cleaning with water wand and inspecting chickens seemed light work because the farmers walked around most of their working time. The operations of detaching base from hanging feeder and attaching base to hanging feeder had the farmers continue squatting to handle the feeders close to the floor. The farmers also repeatedly bent their trunks in shoveling feces, unloading a box of chicks, and releasing chicks. A power grip was frequently observed due to using tools with round handles. Workplace design to raise working height would be necessary for a better working environment for broiler farmers.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2012, 18, 1; 67-75
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biodegradable dextran-based nanoparticles as potential anticancer drug carrier
Otrzymywanie biodegradowalnych nanocząstek dekstranowych jako potencjalnych nośników leków przeciwnowotworowych
Autorzy:
Janczewska, M.
Jung, P.
Ciach, T.
Powiązania:
https://bibliotekanauki.pl/articles/2072960.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
anticancer therapy
polymer nanoparticles
preparation
cytotoxicity
terapia przeciwnowotworowa
nanocząstki polimerowe
preparatyka
cytotoksyczność
Opis:
Dextran-polycaprolactone nanoparticles were prepared and the influence of catalyst on particle diameter was investigated. Nanoparticles were synthesized by the simple one-pot reaction of spontaneous dextran modification with ɛ-caprolactone. Afterwards, nanoparticles were purified by dialysis, spray-dried and checked for cytotoxicity by the MTT assay. Prepared particles are a promising carrier for anticancer drug due to their biocompatibility and a narrow size distribution.
Otrzymano nanocząstki dekstranowe z użyciem polikaprolaktonu jako czynnika zwijającego oraz zbadano wpływ ilości katalizatora na ich średnicę. Synteza składa się z prostej jednostopniowej reakcji, w czasie której zachodzi polimeryzacja ε-kaprolaktonu na łańcuchu dekstranowym, a następnie spontaniczne zwinięcie łańcucha w cząstkę. Nanocząstki oczyszczono poprzez dializę, suszono rozpyłowo i przebadano pod kątem cytotoksyczności testem MTT. Otrzymane nanocząstki są obiecującym nośnikiem dla leków przeciwnowotworowych ze względu na wąski rozkład średnic oraz biokompatybilność.
Źródło:
Inżynieria i Aparatura Chemiczna; 2014, 4; 251--252
0368-0827
Pojawia się w:
Inżynieria i Aparatura Chemiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Development of PAOT Tool Kit for Work Improvements in Clinical Nursing
Autorzy:
Jung, M.- H.
Powiązania:
https://bibliotekanauki.pl/articles/90109.pdf
Data publikacji:
2014
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
clinical nursing practice
PAOT
participatory action-oriented training
tool kit
personel pielęgniarski
lista kontrolna
ankietowanie
praktyka
Opis:
The aim of this study was to develop an action checklist for educational training of clinical nurses. The study used qualitative and quantitative methods. Questionnaire items were extracted through in-depth interviews and a questionnaire survey. PASW version 19 and AMOS version 19 were used for data analyses. Reliability and validity were tested with both exploratory and confirmative factor analysis. The levels of the indicators related to goodness-of-fit were acceptable. Thus, a model kit of work improvements in clinical nursing was developed. It comprises 5 domains (16 action points): health promotion (5 action points), work management (3 action points), ergonomic work methods (3 action points), managerial policies and mutual support among staff members (3 action points), and welfare in the work area (2 action points).
Źródło:
International Journal of Occupational Safety and Ergonomics; 2014, 20, 1; 149-158
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Flexion and Extension Angles of Resting Fingers and Wrist
Autorzy:
Lee, K.-S.
Jung, M.- C.
Powiązania:
https://bibliotekanauki.pl/articles/90396.pdf
Data publikacji:
2014
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
finger
wrist
resting posture
angle
palce
nadgarstek
kąt zgięcia
pozycja odpoczynku
Opis:
This study determined flexion and extension angles of resting fingers and wrist in terms of forearm posture (neutral, pronation and supination) and shoulder flexion (0°, 45°, 90° and 135°). The participants participated in 12 angle measurements for 16 finger joints and wrist. The finger joints flexed more in supination than in neutral posture and pronation and the thumb flexed more than the other fingers because of the gravity and skin tension. This phenomenon became more apparent as the shoulder flexed. The carpometacarpal joint had the largest flexion angle in the thumb joints, whereas the proximal interphalangeal joints had the largest flexion angles in the other finger joints. The resting posture of the wrist extended of ~16° in any forearm postures when the shoulder was at 0°. The results of this study could be useful for rehabilitation tool and product designs.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2014, 20, 1; 91-101
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative analysis of numerical and experimental studies of the airflow around the sample of urban development
Autorzy:
Gumowski, K.
Olszewski, O.
Poćwierz, M.
Zielonko-Jung, K.
Powiązania:
https://bibliotekanauki.pl/articles/200297.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
environmental wind engineering
airflow around buildings
CFD simulation
k-ε realizable model of turbulence
inżynieria wiatrowa
środowisko
przepływ powietrza wokół budynków
symulacja CFD
Opis:
In this paper, on the background of a short overview of the recent advances in the field of Environmental Wind Engineering (EWE), a comparison of wind tunnel experiment and numerical simulation for some cases of airflow around an urban layout have been reported. The purpose of the study is quantitative and qualitative comparison of measurements in the wind tunnel as well as numerical simulation using Ansys Fluent software. The study is concerned mostly with the analysis of parameters which are essential in the building industry, such as pressure and velocity fields. In the numerical analysis the k-ε realizable model of turbulence with the basic model of boundary layer – Standard Wall Treatment, were used. Particular attention has been paid to accurate depiction of the conditions on the inlet and the selection of suitable computing.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2015, 63, 3; 729-737
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evolution Of Precipitate Morphology During Extrusion In Mg ZK60A Alloy
Ewolucja morfologii wydzieleń podczas wytłaczania stopu Mg ZK60A
Autorzy:
Park, J.
Jung, K. H.
Lee, G. A.
Kawasaki, M.
Ahn, B.
Powiązania:
https://bibliotekanauki.pl/articles/356233.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
magnesium alloy
ZK60A
precipitation
extrusion
stopy magnezu
wydzielenia
wytłaczanie
Opis:
In this study, a continuously casted ZK60A magnesium alloy (Mg-Zn-Zr) was extruded in two different extrusion ratios, 6:1 and 10:1. The evolution of precipitates was investigated on the two extruded materials and compared with that of as-casted material. The microstructural analysis was performed by electron backscatter diffraction and transmission electron microscopy, and the compositional information was obtained using energy-dispersive X-ray spectroscopy. Several distinct morphologies of precipitates were observed, such as dot, rod, and disk shaped. The formation mechanisms of those precipitates were discussed with respect to the heat and strain during the extrusion process.
Źródło:
Archives of Metallurgy and Materials; 2015, 60, 2B; 1423-1426
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Improved Light Conversion Efficiency Of Dye-Sensitized Solar Cell By Dispersing Submicron-Sized Granules Into The Nano-Sized TiO2 Layer
Poprawa efektywności konwersji światła ogniw słonecznych uczulonych barwnikiem poprzez rozproszenie submikronowych granulek w warstwie nanocząstek TiO2
Autorzy:
Song, S. A.
Lim, M. J.
Jung, K. Y.
So, W.-W.
Moon, S.-J.
Powiązania:
https://bibliotekanauki.pl/articles/353347.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
titania nanoparticles
granules
dye-sensitized solar cell
light scattering
spray pyrolysis
nanocząsteczki tytanu
granulat
uczulone barwnikiem ogniwa słoneczne
rozpraszanie światła
Opis:
In this work, TiO2 nanoparticles and submicron-sized granules were synthesized by a hydrothermal method and spray pyrolysis, respectively. Submicron-sized granules were dispersed into the nano-sized TiO2 layer to improve the light conversion efficiency. Granules showed better light scattering, but lower in terms of the dye-loading quantity and recombination resistance compared with nanoparticles. Consequently, the nano-sized TiO2 layer had higher cell efficiency than the granulized TiO2 layer. When dispersed granules into the nanoparticle layer, the light scattering was enhanced without the loss of dye-loading quantities. The dispersion of granulized TiO2 led to increase the cell efficiency up to 6.51%, which was about 5.2 % higher than that of the electrode consisting of only TiO2 nanoparticles. Finally, the optimal hydrothermal temperature and dispersing quantity of granules were found to be 200°C and 20 wt%, respectively.
Źródło:
Archives of Metallurgy and Materials; 2015, 60, 2B; 1467-1471
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies