Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Januszkiewicz, Lukasz" wg kryterium: Autor


Wyświetlanie 1-5 z 5
Tytuł:
Wireless Capsule Endoscope Localization with Phase Detection Algorithm and Simplified Human Body Model
Autorzy:
Oleksy, Paweł
Januszkiewicz, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/226699.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
wireless endoscope
human body model
wireless localization
wireless communication
Opis:
Wireless endoscopic capsules can transmit the picture of the inside of the digestive tract to the external receiver for the purpose of gastrointestinal diseases diagnose. The localization of the capsule is needed to correlate the picture of detected anomalies with the particular fragment of intestine. For this purpose, the analysis of wireless transmission parameters can be applied. Such methods are affected by the impact of the human body on the electromagnetic wave propagation that is specific to the anatomy of individual person. The article presents the algorithm of localization of endoscopic capsules with wireless transmitter based on the detection of phase difference of received signals. The proposed algorithm uses simplified human body models that can change their dielectric properties in each iteration to improve the location of the capsule endoscope. Such approach allows to reduce localization error by around 12 mm (15%) and can by used for patients of different physique without the need of the numerical models of individual body.
Źródło:
International Journal of Electronics and Telecommunications; 2020, 66, 1; 45-51
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metallic Electroconductive Transmission Lines Obtained on Textile Substrates by Magnetron Sputtering
Metaliczne ścieżki elektroprzewodzące wytwarzane metodą rozpylania magnetronowego na podłożach tekstylnych
Autorzy:
Nowak, Iwona
Krucińska, Izabella
Januszkiewicz, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/232207.pdf
Data publikacji:
2019
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
magnetron sputtering
electroconductive paths
e-textile
vacuum deposition
rozpylanie magnetronowe
ścieżki elektroprzewodzące
e-tekstylia
osadzanie próżniowe
Opis:
The paper discusses the results of research concerning the formation of electroconductive transmission lines on textile substrates using the magnetron sputtering technique. The transmission lines developed can potentially be applied in clothing for emergency and security services to affect electrical connections between electronic elements incorporated in the garments. The time of metallic layer deposition and the type of substrate used was optimised in the study. The surface resistivity, resistance to bending and abrasion of the transmission lines obtained were tested. The tests demonstrated that it is possible to obtain electroconductive copper layers with a surface resistivity approximating 0.2 Ω by direct deposition on spun-bonded type polypropylene nonwoven.
W pracy metodą rozpylania magnetronowego wytworzono ścieżki elektroprzewodzące na podłożach tekstylnych do zastosowania w odzieży dla służb bezpieczeństwa. Optymalizowano czas depozycji warstwy oraz rodzaj użytego substratu tekstylnego. Zbadano rezystywność powierzchniową, odporność na zginanie i ścieranie wytworzonych ścieżek.
Źródło:
Fibres & Textiles in Eastern Europe; 2019, 3 (135); 51-57
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Inertial Sensors Integrated with Clothing to Localize People Inside Buildings
Autorzy:
Kawecki, Jaroslaw
Oleksy, Pawel
Januszkiewicz, Lukasz
Powiązania:
https://bibliotekanauki.pl/articles/227250.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
inertial sensors
wearable systems
step length estimation
indoor localization
localization system
intelligent T-shirt
Opis:
This article presents a wearable system that localizes people in the indoor environment, using data from inertial sensors. The sensors measure the parameters of human motion, tracking the movements of the torso and foot. For this purpose, they were integrated with shirt and the shoe insole. The values of acceleration measured by the sensors are sent via Bluetooth to a smartphone. The localization algorithm implemented on the smartphone, presented here, merges data from the shirt and the shoe to track the steps made by the user and filter out the localization errors caused by movements the shirt and torso. The experimental verification of the algorithm is also presented.
Źródło:
International Journal of Electronics and Telecommunications; 2020, 66, 1; 53-58
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Periprocedural decrease in tumor necrosis factor alpha is a risk factor for atrial fibrillation recurrence after ablation
Autorzy:
Szczerba, Ewa
Koźluk, Edward
Januszkiewicz, Łukasz
Lisicka, Monika
Nowak, Justyna
Kondracka, Agnieszka
Majstrak, Joanna
Rodkiewicz, Dariusz
Piątkowska, Agnieszka
Kiliszek, Marek
Opolski, Grzegorz
Powiązania:
https://bibliotekanauki.pl/articles/25712809.pdf
Data publikacji:
2022-12-05
Wydawca:
Gdański Uniwersytet Medyczny
Tematy:
atrial fibrillation
ablation
TNF-alpha
Opis:
Background Concentration of tumor necrosis factor alpha (TNF-alpha) might be useful in selecting patients with paroxysmal atrial fibrillation (PAF) who will benefit the most from pulmonary vein isolation. Material and methods We performed prospective cohort study among patients with PAF who had sinus rhythm prior to undergoing either radiofrequency ablation or cryoablation procedure. Blood samples were collected at the start of the procedure and 16-24 h after. TNF-alpha concentrations were measured. Follow-up data was obtained during a structured telephone interview and 24-hour ECG Holter monitoring 12 months after the ablation procedure. Results Thirty seven patients were enrolled. After 12-month follow-up 27 patients maintained sinus rhythm, 8 had recurrence of AF and 2 were lost to follow-up. There was no significant correlation between TNF-alpha concentrations in any of the samples and the recurrence of arrhythmia (for pre-procedural samples: 1.75 pg/ml vs 1.74 pg/ml; p=0.72; for post-procedural samples: 1.49 pg/ml vs 1.79 pg/ml; p=0.16). In patients who had a recurrence of AF, we observed a decrease in the periprocedural TNF-alpha concentration (-0.12 pg/ml vs 0.05 pg/ml; p=0.05). Conclusions Neither pre- nor post-procedural TNF-alpha concentrations are predictive of ablation outcome in patients with PAF. We observed a decrease in the periprocedural TNF-alpha concentration in patients who had AF recurrence.
Źródło:
European Journal of Translational and Clinical Medicine; 2022, 5, 2; 16-23
2657-3148
2657-3156
Pojawia się w:
European Journal of Translational and Clinical Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Współczynnik żyła główna dolna/aorta w ocenie nawodnienia – porównawcza ocena wyników pomiarów doświadczonych i niedoświadczonych badaczy w grupie młodych dorosłych
Inferior vena cava/aorta diameter index in the assessment of the body fluid status – a comparative study of measurements performed by experienced and inexperienced examiners in a group of young adults
Autorzy:
Durajska, Kaja
Januszkiewicz, Emilia
Szmygel, Łukasz
Kosiak, Wojciech
Powiązania:
https://bibliotekanauki.pl/articles/1057904.pdf
Data publikacji:
2014
Wydawca:
Medical Communications
Tematy:
body fluid status
inexperienced examiners
inferior vena cava/aorta diameter index
longitudinal plane
transverse plane
nawodnienie
niedoświadczeni badający
poprzeczna
projekcja podłużna
współczynnik żyła główna dolna/aorta
Opis:
The assessment of the body fluid status is one the most challenging tasks in clinical practice. Although there are many methods to assess the body fluid status of patients, none of them is fully satisfactory in contemporary medical sciences. In the article below, we compare the results of measurements performed by experienced and inexperienced examiners based on the inferior vena cava/aorta diameter index in a sonographic hydration assessment. The study enrolled 50 young students at the age of 19–26 (the median age was 22.95) including 27 women and 23 men. The volunteers were examined in the supine position with GE Logiq 7 system and a convex transducer with the frequency of 2–5 MHz. The measurements were performed in the longitudinal and transverse planes by two inexperienced examiners – the authors of this paper, following a four-hour training conducted by an experienced sonographer. The longitudinal values of the inferior vena cava/aorta diameter index obtained in this study were similar to those found in the literature. The reference value for the inferior vena cava/aorta index determined by Kosiak et al., which constituted 1.2 ± 2 SD, for SD = 0.17, was similar to the values obtained by the authors of this paper which equaled 1.2286 ± 2 SD, for SD = 0.2. The article presented below proves that measuring the inferior vena cava/aorta diameter index is not a complex examination and it may be performed by physicians with no sonographic experience. Furthermore, the paper demonstrates that the inferior vena cava/aorta diameter index measured in the transverse plane is similar to the inferior vena cava/aorta diameter index determined in the longitudinal plane. Thus, both measurements may be used interchangeably to assess the hydration status of patients.
Ocena stanu nawodnienia jest jednym z najtrudniejszych zadań dla lekarzy klinicystów. Pomimo istnienia wielu metod oceniających stan nawodnienia pacjentów żadna z procedur nie jest w pełni satysfakcjonująca w obecnej dobie nauk medycznych. W przedstawionym poniżej artykule porównano wyniki pomiarów wykonanych przez doświadczonych i niedoświadczonych badaczy w ultrasonograficznej ocenie stanu gospodarki wodnej, bazując na określeniu współczynnika żyła główna dolna/aorta. Badaniami objęto 50 młodych studentów, w wieku od 19 do 26 lat (mediana wieku – 22,95 roku), w tym 27 kobiet oraz 23 mężczyzn. Ochotników badano w pozycji leżącej na plecach, aparatem GE Logiq 7, głowicą typu convex o częstotliwości 2–5 MHz. Pomiary zostały w ykonane w projekcji podłużnej i poprzecznej przez dwóch niedoświadczonych badających, autorów pracy, po wcześniejszym czterogodzinnym przeszkoleniu przez doświadczonego lekarza ultrasonografistę. W badanej grupie stwierdzono podobne wyniki współczynnika żyła główna dolna/aorta w projekcji podłużnej do podawanych w piśmiennictwie. Norma dla współczynnika żyła główna dolna/ aorta wyznaczona przez zespół Kosiaka i wsp., która wyniosła 1,2 ± 2 odchylenia standardowe, dla odchylenia standardowego 0,17, była zbliżona do wartości współczynnika uzyskanego przez autorów, wynoszącego 1,2286 ± 2 odchylenia standardowe, dla odchylenia standardowego 0,2. W przedstawionym artykule udowodniono, że pomiar współczynnika żyła główna dolna/aorta jest badaniem nieskomplikowanym, możliwym do wykonywania przez lekarzy niemających praktyki ultrasonograficznej. Ponadto wykazano, że współczynnik żyła główna dolna/aorta uzyskany w pomiarach w projekcji poprzecznej jest podobny do współczynnika żyła główna dolna/aorta w pomiarach w projekcji podłużnej – oba pomiary mogą być wykorzystywane zamiennie do oceny stopnia nawodnienia pacjentów.
Źródło:
Journal of Ultrasonography; 2014, 14, 58; 273-279
2451-070X
Pojawia się w:
Journal of Ultrasonography
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies