Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Iwasaki, S.-I." wg kryterium: Autor


Wyświetlanie 1-1 z 1
Tytuł:
Evaluation of reliability of perioral muscle pressure measurements using a newly developed device with a lip piece
Autorzy:
Takahashi, M.
Koide, K.
Suzuki, H.
Satoh, Y.
Iwasaki, S.-I.
Powiązania:
https://bibliotekanauki.pl/articles/306575.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
nacisk
wiarygodność
mięśnie
jama ustna
tongue pressure
upper lip pressure
lower lip pressure
absolute reliability
relative reliabilit
Opis:
Purpose: We examined the reliability of measurements using a newly developed perioral muscle pressure measuring device with a lip piece in healthy adults. Methods: Subjects were 40 healthy men (25.8 years) with normal stomatognathic function. Perioral muscle pressure measuring device with a lip piece was used to measure upper lip, lower lip and tongue pressure, and a balloon-based measurement device was used to measure tongue and cheek pressure. Each measurement was taken twice with a 1-min interval between the two measurements. We determined intra-rater reliability by using the intra-class correlation coefficient as a test of relative reliability. As a test of absolute reliability, Bland–Altman analysis was used to assess systematic bias and the 95% confidence interval of the minimal detectable change was calculated. Additionally, the coefficient of variation was calculated. The Spearman–Brown formula was calculated the number of measurements needed to achieve a confidence coefficient ≥0.9. Each set of measurements was followed by a second set that were taken 1 week later. Results: All measurements showed high values of intra-class correlation coefficient. Upper lip, tongue, and cheek pressure can be determined based on a single measurement, while lower lip pressure requires averaging twice. No systematic bias was observed. The coefficients of variation of measurements were almost the same between the two devices. Conclusion: Measurements were highly reliable regardless of the type of perioral muscles. Our findings suggest that the method described in this study is useful as a quantitative chair side method for examining perioral muscle pressure.
Źródło:
Acta of Bioengineering and Biomechanics; 2016, 18, 1; 145-153
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-1 z 1

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies