Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Ivanenko, I." wg kryterium: Autor


Wyświetlanie 1-3 z 3
Tytuł:
A method of the magnetic field formation in cyclotron DC-72
Autorzy:
Gulbekian, G.
Ivanenko, I.
Filatov, O.
Franko, J.
Kukhtin, V.
Lamzin, E.
Samsonov, E.
Semchenkov, A.
Semchenkova, O.
Sytchevsky, S. E.
Dmitrev, S. N.
Powiązania:
https://bibliotekanauki.pl/articles/148354.pdf
Data publikacji:
2003
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
cyclotron
magnetic field measurements
magnetic field simulations
Opis:
A method of the magnetic field formation in the cyclotron DC-72 model (scale 1:5) is described. The cyclotron is planned to be built in Slovakia. The stages in the shimming of the cyclotron sectors and an automatic system designed for magnetic measurements are described. The data on the magnetic field measurements in the median plane of the cyclotron are presented. A brief description of a computer simulation model and an algorithm of fitting the required sector profiles is presented, as well as the data on the computer simulation of magnetic field distributions. The data on the magnetic field measurements and those on the computer simulations are compared and analyzed. Possible reasons of differences between the measured and simulated data are discussed. The results of the above mentioned computer simulations will be used for building a large facility - the cyclotron DC-72.
Źródło:
Nukleonika; 2003, 48, 4; 207-210
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Status report of the VINCY Cyclotron
Autorzy:
Nešković, N.
Ristić-Ðurović, J.
Vorojtsov, S. B.
Belicev, P.
Ivanenko, I. A.
Ćirković, S.
Vorozhtsov, A. S.
Bojović, B.
Dobrosavljević, A.
Vujović, V.
Comor, J. j.
Pajović, S. B.
Powiązania:
https://bibliotekanauki.pl/articles/146191.pdf
Data publikacji:
2003
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
accelerators
cyclotrons
ion sources
radioisotopes
radiation research
Opis:
The VINCY Cyclotron is the main part of the TESLA Accelerator Installation. The diameter of the pole of this machine is 2000 mm. Its bending constant is 145 MeV while its focusing constant is 75 MeV. The radiofrequency system of the machine consists of two l/4-resonators with the eigenfrequency in the range from 17 to 31 MHz. Ions coming from a heavy ion source or a light ion source will be injected into the machine axially. They will be introduced into its median plane by a spiral inflector. Heavy ions accelerated in the machine will be extracted from it by a foil stripping system or by an electrostatic deflection system. Light ions will be extracted from it by the foil stripping system. The first programs of use of the VINCY Cyclotron are related to routine and experimental production of radioisotopes and radiopharmaceuticals, and to biomedical research with ion beams. The first beam extracted from the machine will be the proton beam of the energy of 22 MeV obtained from the H2+ beam extracted from the light ion source. This beam will be used first for production of radioisotope 18F and radio-pharmaceutical 18FDG, to be employed for positron emission tomography
Źródło:
Nukleonika; 2003, 48,suppl.2; 135-139
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fe2+ removal from water using PVDF membranes, modified with magnetite nanoparticles, by polyelectrolyte enhanced ultrafiltration
Usuwanie Fe2+ z wody za pomocą membran PVDF modyfikowanych nanocząstkami magnetytu, wspomagane ultrafiltracją z polielektrolitem
Autorzy:
Konovalova, V.
Kolesnyk, I.
Ivanenko, O.
Burban, A.
Powiązania:
https://bibliotekanauki.pl/articles/297504.pdf
Data publikacji:
2018
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
polyvinylidene fluoride membrane
magnetite nanoparticles
polyelectrolyte-enhanced ultrafiltration
carboxymethylcellulose
membrany z fluorku poliwinylidenu
nanocząstka magnetytu
ultrafiltracja z polielektrolitem
karboksymetyloceluloza
Opis:
The aim of this study was to show results of Fe2+ removal from water by polyelectrolyte enhanced ultrafiltration on polyvinylidene fluoride membranes modified with magnetite nanoparticles. Magnetite nanoparticles were synthesized by the co-precipitation method and stabilized with sodium polyacrylate. At first stage, the surface of PVDF membranes was modified by grafting of polyethylenimine. At the second stage the polyelectrolyte, grafted to the membrane surface, was used as a linker for magnetite nanoparticles immobilization. The modification of membranes was confirmed by IR spectroscopy, scanning electron microscopy and electro kinetic analysis. The dependence of zeta-potential on pH for PVDF membrane modified with PEI has confirmed the modification of the membrane surface as zeta-potential increases with pH decrease. SEM has shown that the surface of modified membrane is densely covered with nanoparticles, which form clusters. The dependence of the volumetric flux on the applied pressure at various concentrations of the carboxymethylcellulose (CMC) has been studied. Polyelectrolyte enhanced ultrafiltration with CMC has been used for iron(II) removal at initial Fe2+ concentration of 20 mg/L. The concentrations of iron(II) in permeate using an unmodified membrane has ranged from 0.6 to 1.0 mg/L, whereas for the modified membrane it has been 0.02÷0.08 mg/L.
Celem pracy było przedstawienie wyników badań dotyczących usuwania Fe2+ z wody za pomocą ultrafiltracji wspomaganej polielektrolitem na membranach z fluorku poliwinylidenu modyfikowanych nanocząstkami magnetytu. Nanocząstki magnetytu zostały zsyntetyzowane z wykorzystaniem metody strąceniowej i ustabilizowane poliakrylanem sodu. W pierwszym etapie powierzchnia membran PVDF została poddana modyfikacji polietylenoiminą. W drugim etapie polielektrolit, umieszczony na powierzchni membrany, został wykorzystany do immobilizacji nanocząstek magnetytu. Modyfikacja membran została potwierdzona badaniami spektroskopowymi, elektronową mikroskopią skaningową i analizą elektrokinetyczną. Wpływ pH na potencjał zeta membrany PVDF potwierdził jej modyfikację membrany, gdy potencjał zeta wzrasta z obniżeniem się wartości pH. Elektronowa mikroskopia skanningowa wykazała, że powierzchnia modyfikowanej membrany jest gęsto pokryta nanocząstkami, które tworzą klastry. Badano również wpływ wartości stosowanego ciśnienia na objętościowy strumień permeatu dla różnych stężeń karboksymetylocelulozy (CMC). Ultrafiltracja wspomagana polielektrolitem z CMC została wykorzystana do usuwania żelaza(II) przy początkowym stężeniu Fe2+ wynoszącym 20 mg/l. Stężenie żelaza(II) w permeacie w przypadku membrany niepoddanej modyfikacji uległo zmianie z 0,6 do 1,0 mg/l, podczas gdy w przypadku modyfikowanej membrany stężenie to było w zakresie 0,02÷0,08 mg/l.
Źródło:
Inżynieria i Ochrona Środowiska; 2018, 21, 1; 39-49
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies