Tytuł:
Experimental and numerical studies of fatigue properties of carbon/glass fiber/epoxy hybrid composites enhanced with nano TiO2 powder
Autorzy:
Hunain, Mustafa Baqir
Abass, Basim A.
Akhudair, Jaafar Musa
Powiązania:
https://bibliotekanauki.pl/articles/1840903.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
hybrid nano-composite materials
fatigue
mechanical properties
hybrydowy materiał kompozytowy
nanokompozyt
zmęczenie
właściwości mechaniczne
Opis:
The present work deals with the fatigue behavior of hybrid nanocomposites consisting epoxy strengthen by unidirectional carbon fibres, and/or woven roving glass fiber and TiO2 nanofillers. For this purpose, nanocomposite material was manufactured by mixing TiO2 nanoparticles with the epoxy using an ultrasonic mixer to insure complete dispersion of such particles in the base material. Different particle concentrations (1, 3, and 5) % wt. of TiO2 nanoparticles have been added to the epoxy. Different types of hybrid nano composite materials were manufactured by adding three layers of carbon fibers and/or woven roving glass fiber to the prepared epoxy nanocomposite materials with a constant weight fraction of 30%. The laminated hybrid nanocomposite materials were then prepared using hand lay-up technique using a vacuum device. For experimental purposes tensile and fatigue test specimens have been manufactured according to ASTM-D3039 and ASTM D 3479/D 3479M-96, respectively, while ANSYS19 program was used to analyze the fatigue behavior of such materials numerically. Tensile tests were carried out at room temperature while fatigue tests has been carried out at constant stress ratio (R=-1). Scanning electron microscope (SEM) was used to identify the underlying mechanisms for fatigue failure and the progressive of damage growth. For each test, three specimens were tested and the average magnitude for each property was taken. The results obtained indicated that the hybrid nanocomposite (EP+C/C/C+3% TiO2) has the highest fatigue limit and tensile strength in comparison with the other tested material, while the SEM results showed that the composite failed by a brittle way. It has been also generally observed that the addition of (TiO2) nanoparticles has a positive effect on the fatigue behaviour of the such materials.
Źródło:
Diagnostyka; 2021, 22, 2; 75-84
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mechanical properties and fatigue life detection of copper particle filled polyester composite material under rotating bending load
Autorzy:
Hamzah, Ahmed Fadhil
Al-Turaihi, Ali S.
Hunain, Mustafa Baqir
Fadhel, Essam Zuheir
Powiązania:
https://bibliotekanauki.pl/articles/1840852.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
polymer matrix composite
particle copper reinforcement
tensile strength
fatigue
kompozyt polimerowy
wytrzymałość na rozciąganie
zmęczenie
Opis:
In the present investigation, the fatigue life detection of composite material by adding copper particle of about than 25 μm diameter with 5, 10, 15 % volume fraction, as a reinforcements into the unsaturated polyester polymer composite material on fatigue life detection of composite material were studied experimentally and numerically. Composites were made using hand lay-up technique and evaluated for mechanical and fatigue properties in accordance with ASTM standards. The experimental results of the tensile test showed that adding 15% of copper particle in unsaturated polyester gives maximum ultimate tensile stress. Fatigue tests including test rod specimens made of composite materials under completely reversed cyclic loading in a rotating cantilever reversed bending machine. It is found that, the fatigue life and fatigue strength increase with increasing in the copper percentage volume fraction in unsaturated polyester resin compared with pure polyester composites. The experimental work was compared with numerical work, which was done by using ANSYS/19 and good agreement has been found. The maximum overall difference between the experimental and numerical work was around 9 %.
Źródło:
Diagnostyka; 2021, 22, 3; 35-42
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mechanical properties and fatigue life detection of copper particle filled polyester composite material under rotating bending load
Autorzy:
Hamzah, Ahmed Fadhil
Al-Turaihi, Ali S.
Hunain, Mustafa Baqir
Fadhel, Essam Zuheir
Powiązania:
https://bibliotekanauki.pl/articles/1840866.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
polymer matrix composite
particle copper reinforcement
tensile strength
fatigue
kompozyt polimerowy
wytrzymałość na rozciąganie
zmęczenie
Opis:
In the present investigation, the fatigue life detection of composite material by adding copper particle of about than 25 μm diameter with 5, 10, 15 % volume fraction, as a reinforcements into the unsaturated polyester polymer composite material on fatigue life detection of composite material were studied experimentally and numerically. Composites were made using hand lay-up technique and evaluated for mechanical and fatigue properties in accordance with ASTM standards. The experimental results of the tensile test showed that adding 15% of copper particle in unsaturated polyester gives maximum ultimate tensile stress. Fatigue tests including test rod specimens made of composite materials under completely reversed cyclic loading in a rotating cantilever reversed bending machine. It is found that, the fatigue life and fatigue strength increase with increasing in the copper percentage volume fraction in unsaturated polyester resin compared with pure polyester composites. The experimental work was compared with numerical work, which was done by using ANSYS/19 and good agreement has been found. The maximum overall difference between the experimental and numerical work was around 9 %.
Źródło:
Diagnostyka; 2021, 22, 3; 35-42
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies