Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Hernik, B." wg kryterium: Autor


Wyświetlanie 1-6 z 6
Tytuł:
Numerical calculations of WR-40 boiler based on its zero-dimensional model
Autorzy:
Hernik, B.
Powiązania:
https://bibliotekanauki.pl/articles/185324.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
modelowanie CFD
kocioł
spalanie
ruszt
CFD modelling
boilers
combustion
grate
Opis:
Generally, the temperature of flue gases at the furnace outlet is not measured. Therefore, a special computation procedure is needed to determine it. This paper presents a method for coordination of the numerical model of a pulverised fuel boiler furnace chamber with the measuring data in a situation when CFD calculations are made in regard to the furnace only. This paper recommends the use of the classical 0-dimensional balance model of a boiler, based on the use of measuring data. The average temperature of flue gases at the furnace outlet t”k obtained using the model may be considered as highly reliable. The numerical model has to show the same value of t”k. This paper presents calculations for WR-40 boiler. The CFD model was matched to the 0-dimensional t”k value by means of a selection of the furnace wall emissivity. As a result of CFD modelling, the flue gas temperature and the concentration of CO, CO2, O2 and NOx were obtained at the furnace chamber outlet. The results of numerical modelling of boiler combustion based on volumetric reactions and using the Finite Rate/Eddy-Dissipation Model are presented.
Źródło:
Chemical and Process Engineering; 2014, 35, 2; 173-180
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A zero-dimensional model used as a basis for numerical modelling of OP-650 boiler
Zerowymiarowy model kotła jako podstawa do obliczeń numerycznych kotła OP 650
Autorzy:
Hernik, B.
Pronobis, M.
Powiązania:
https://bibliotekanauki.pl/articles/172845.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power boiler
OP650 boiler
zero-dimensional model
CFD modelling
numerical modelling
kocioł energetyczny
kocioł OP-650
model zero-wymiarowy
modelowanie CFD
modelowanie numeryczne
Opis:
The numerical modelling of power boiler furnaces is often performed in the engineering practice. Quite often, however, the balance calculations of the entire boiler are not carried out. In this case, the flue gas temperature at the furnace outlet results from the numerical model and depends on the adopted assumptions (e.g. wall fouling or emissivity). However, the value determined in this way may be wrong, and the presented calculation method makes it impossible to verify it. One of the ways to improve the numerical model accuracy is the verification of the flue gas temperature at the furnace outlet value by calculations fully balanced by a zero-dimensional (0D) model based on measuring data. The numerical calculations should be carried in such a way that the average temperature at the furnace outlet in the computational fluid dynamical (CFD) model equals the temperature obtained from the 0D model. At the same time, the matching of this temperature should result from carefully selected assumptions of the numerical model, which have to correspond to the actual phenomena occurring in the furnace. This model presents the verification of the CFD model for the OP-650 boiler of a 225 MWel power unit. The results of numerical modelling of boiler according to non-premixed combustion model with mixture fraction/PDF (probability density function) approach was presented. Also numerical modelling of boiler with species transport model with volumetric reactions and finite rate chemistry was done.
W praktyce inżynierskiej często wykonywane jest numeryczne modelowanie palenisk kotłów energetycznych, przy czym często nie prowadzi się obliczeń bilansowych całego kotła. Temperatura spalin na wylocie z paleniska wynika wówczas z modelu numerycznego i zależy od przyjętych założeń (np. zanieczyszczenie ścian lub ich emisyjność). Tak wyznaczona wartość temperatury może jednak być błędna, a opisany sposób liczenia uniemożliwia jej weryfikację. Sposobem na poprawę dokładności modelu numerycznego jest weryfikacja temperatury spalin na wylocie z paleniska za pomocą w pełni zbilansowanych obliczeń modelem 0-wymiarowym opartym na danych pomiarowych. Obliczenia numeryczne powinny być tak prowadzone, aby średnia temperatura na wylocie z komory paleniskowej kotła w modelu CFD była równa temperaturze uzyskanej z modelu zerowymiarowego. Jednocześnie dopasowanie tej temperatury powinno wynikać z odpowiednio dobranych założeń modelu numerycznego, które muszą odpowiadać realnemu przebiegowi zjawisk zachodzących w palenisku. W niniejszej pracy dokonano opisanej weryfikacji modelu CFD dla kotła OP 650 do bloku 225 MWel. Przedstawiono wyniki modelowania numerycznego kotła wg algorytmu mixture fraction/PDF - z wykorzystaniem modelu spalania non-premixed oraz wyniki dla modelu opartego na reakcjach objętościowych z wykorzystaniem modelu finite-rate/eddy-dissipation.
Źródło:
Archiwum Energetyki; 2012, 42, 2; 17-26
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical studies on the influence of air staging on the temperature of flue gas and emission of gases in the combustion chamber of OP 230 boiler
Autorzy:
Hernik, B.
Jagodzińska, K.
Matuszek, D.
Powiązania:
https://bibliotekanauki.pl/articles/185572.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
combustion
CFD
emission
boiler
NOx
spalanie
emisja
bojler
Opis:
The primary methods of reducing nitrogen oxides, despite the development of more advanced technologies, will continue to be the basis for NOx reduction. This paper presents the results of multivariate numerical studies on the impact of air staging on the flue gas temperature and composition, as well as on NOx emissions in a OP 230 boiler furnace. A numerical model of the furnace and the platen superheater was validated based on measurements using a 0-dimensional model of the boiler. Numerical simulations were performed using the ANSYS Workbench package. It is shown that changes in the distribution of air to OFA nozzles, the angle of the air outflow from the nozzles and the nozzle location involve a change in the flue gas temperature and in the volume of NOx and CO emissions at the furnace outlet.
Źródło:
Chemical and Process Engineering; 2018, 39, 1; 59--74
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An analysis of coal and coal mine methane co-combustion in an 140 t/h pulverized coal boiler
Autorzy:
Jagodzińska, K.
Hernik, B.
Pronobis, M.
Powiązania:
https://bibliotekanauki.pl/articles/175356.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Co-combustion
methane
heat transfer
power boiler
Opis:
The paper presents an attempt to evaluate the impact of coal and coal mine methane cocombustion on the physics of the heat exchange in an 140 t/h pulverized-coal boiler through an analysis of 21 combinations of the boiler operating parameters – three different boiler loads (50, 75, and 100%) and seven values of the fired gas thermal contribution (0–60%). The obtained results are the temperature distribution of flue gas and steam in the boiler characteristic points, the heat transfer coefficient values for the boiler individual elements expressing the nature of changes in the heat transfer and the change in the boiler efficiency depending on how much gas is actually fired. An increase in the amount of co-fired gas involves a temperature increase along the flue gas path. This is the effect of the reduction in the amount of heat collected by the evaporator in the furnace. For these reason, the flue gas temperature at the furnace outlet rises by 9 K on average per a 0.1 increment in the fired gas thermal contribution. The temperature rise improves the heat transfer in the boiler heat exchangers – for the first- and the secondstage superheater the improvement totals 2.8% at a 10 pp. increase in the fired gas thermal contribution. However, the rise in the flue gas temperature at the boiler outlet involves a drop in the boiler efficiency (by 0.13 pp. for a rise in the fired gas thermal contribution by 0.1).
Źródło:
Transactions of the Institute of Fluid-Flow Machinery; 2017, 137; 3-18
0079-3205
Pojawia się w:
Transactions of the Institute of Fluid-Flow Machinery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modification of Linen Fabrics with Health Promoting Products and its Effect on the Use Properties of the Fabrics and Natural Environment
Modyfikacja tkanin lnianych preparatami pro-zdrowotnymi i jej wpływ na wybrane właściwości użytkowe i środowisko naturalne człowieka
Autorzy:
Marszałek, R
Binkowska, B
Sapieja, A
Hernik, T
Marcinowska, B
Powiązania:
https://bibliotekanauki.pl/articles/234398.pdf
Data publikacji:
2014
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Biopolimerów i Włókien Chemicznych
Tematy:
health promoting substances
linen textiles
use properties
biodegradation
resistance to care
tkaniny lniane
właściwości użytkowe
modyfikacja tkanin lnianych
aloes
wosk pszczeli
białko z jedwabiu naturalnego
produkty prozdrowotne
Opis:
The study involved the determination of the effect of the modification of linen fabrics with health promoting products containing different substances such as vitamin E, beeswax and natural silk protein on the use features of the fabrics and their biodegradation. It was found that enriching linen fabrics with health promoting products contributes to the improvement of their touch, does not have a negative effect on the biodegradation process nor the whiteness degree and the modification effect is resistant to 10 cycles of care processes. The modification causes a decrease in the breaking force and thread slippage index in the stitches. However, the values obtained are in line with the requirements for linen fabrics used for clothing. The modification process also lowers the hygroscopicity, air permeability and, in some cases, water absorption as compared with fabrics before the modification.
W ramach prowadzonych prac badawczych określono wpływ modyfikacji tkanin lnianych produktami pro-zdrowotnymi zawierającymi alternatywnie substancje typu: witaminę E, aloes, wosk pszczeli, białko z jedwabiu naturalnego, na ich właściwości użytkowe i biodegradację. Stwierdzono, że uszlachetnianie tkanin lnianych produktami pro-zdrowotnymi przyczynia się do ich korzystniejszego chwytu, nie wpływa negatywnie na przebieg procesu biodegradacji oraz stopień bieli, a efekt modyfikacji jest odporny na 10-cio krotny proces konserwacji. Proces modyfikacji powoduje obniżenie wartości siły zrywającej i pogorszenie przesuwalności nitek w szwie. Uzyskane wartości są jednak zgodne z wymaganymi dla tkanin lnianych odzieżowych. Proces modyfikacji wpływa również na obniżenie parametrów higroskopijności i przepuszczalności powietrza oraz w niektórych wariantach na obniżenie zdolności wchłaniania wody w porównaniu z tkaninami przed modyfikacją.
Źródło:
Fibres & Textiles in Eastern Europe; 2014, 6 (108); 63-68
1230-3666
2300-7354
Pojawia się w:
Fibres & Textiles in Eastern Europe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie wyników ciepła hydratacji metodą semiadiabatyczną i metodą izotermiczną oraz wyznaczenie współczynnika korelacji
Establishing of the correlation coefficient between results of heat of hydration semi-adiabatic and isothermal method
Autorzy:
Baran, T.
Francuz, P.
Duszak, B.
Pichniarczyk, P.
Hernik, K.
Powiązania:
https://bibliotekanauki.pl/articles/391886.pdf
Data publikacji:
2017
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Ceramiki i Materiałów Budowlanych
Tematy:
cement
ciepło hydratacji
kalorymetria
kalorymetria semiadiabatyczna
kalorymetria izotermiczna
porównanie
współczynnik korelacji
hydration heat
calorimetry
semi-adiabatic calorimetry
isothermal calorimetry
comparison
correlation coefficient
Opis:
Podstawowym celem pracy była próba określenia współczynnika korelacji pomiędzy wynikami badań ciepła hydratacji cementów wykonanych metodą izotermiczną i metodą semiadiabatyczną według PN-EN 196-9. Należy zaznaczyć, że taka korelacja istnieje dla wyniku badania ciepła hydratacji po 41 godzinach metodą semiadiabatyczną według PN-EN 196-9 i wyniku badania po 168 godzinach metodą rozpuszczania według PN-EN 196-8. Badania porównawcze ciepła hydratacji metodą izotermiczną i semiadiabatyczną według PN-EN 196-9 oraz próba określenia współczynnika korelacji pomiędzy tymi metodami prowadzono na wybranych cementach przemysłowych, zróżnicowanych z uwagi na rodzaj i ilość dodatku do cementu oraz stopień rozdrobnienia cementu. Współczynniki korelacji pomiędzy metodą semiadiabatyczną i izotermiczną obliczono i wyrażono jako stosunek ilości wydzielonego ciepła z kalorymetru semiadiabatycznego do ilości wydzielonego ciepła z kalorymetru izotermicznego, dla danego rodzaju cementu i dla danego okresu hydratacji. Porównując współczynniki korelacji badanych cementów, należy podkreślić ich zróżnicowanie dla poszczególnych rodzajów cementów. Wielkość współczynnika korelacji dla cementów portlandzkich CEM I i cementów portlandzkich wieloskładnikowych CEM II maleje z czasem hydratacji. W przypadku cementu hutniczego CEM III obserwujemy wzrost wielkości współczynnika korelacji w przedziale czasowym ok. 24–48 godzin.
The main goal of this work was the determination of the correlation coefficient, between results of the heat of hydration measurements carried out using isothermal method and semi-adiabatic method according to PN-EN 196-9. It should be underlined, that that correlation exists for results of heat of hydration after 41 hours semi-adiabatic method according to PN-EN 196-9 and solution method after 168 hours according to PN-EN 196-8. The comparative studies of heat of hydration by isothermal method and semi-adiabatic method according to PN-EN 196-9 and the determination of the correlation coefficient, between these methods, were carried out with using of the selected industrial cements differentiated by their type, the content of cement addition and its degree of fineness. The correlation coefficients between semi-adiabatic and isothermal methods were calculated and expressed as the ratio of the cumulated heat of hydration from semi-adiabatic calorimeter to the cumulated heat of hydration from isothermal calorimeter, for particular cement and hydration period. Comparing the correlation coefficients of studied cements, their differentiation for particular cement types should be underlined. The value of the correlation coefficient for Portland cements CEM I and Portland cements with additions CEM II decreases over the hydration time. However, in the case of blast-furnace cement, the increase of the correlation coefficient value in time interval about 24–48 hours is observed.
Źródło:
Prace Instytutu Ceramiki i Materiałów Budowlanych; 2017, R. 10, nr 29, 29; 7-17
1899-3230
Pojawia się w:
Prace Instytutu Ceramiki i Materiałów Budowlanych
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies