Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "He, Ping" wg kryterium: Autor


Tytuł:
Dynamic interactions stability analysis of hybrid renewable energy system with SSSC
Autorzy:
He, Ping
Qi, Pan
Ji, Yuqi
Li, Zhao
Powiązania:
https://bibliotekanauki.pl/articles/1841302.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
damping characteristics
dynamic interaction analysis
eigenvalue analysis
hybrid renewable energy system
SSSC
charakterystyka tłumienia
dynamiczna analiza interakcji
analiza wartości własnej
hybrydowy system energii odnawialnej
Opis:
The static series synchronous compensator (SSSC) has demonstrated its capability in providing voltage support and improving power system stability. The objective of this paper is to analyze the dynamic interaction stability mechanism of a hybrid renewable energy system connected with doubly-fed induction generators (DFIGs) and solid oxide fuel cell (SOFC) energy with the SSSC. For this purpose, a linearized mathematical model of this modified hybrid single-machine infinite-bus (SMIB) power system is developed to analyze the physical mechanism of the SSSC in suppressing oscillations and the influence on the dynamic stability characteristics of synchronization. Typical impacting factors such as the series compensation level, the SOFC penetration and tie-line power are considered in the SMIB and two-area systems. The impact of dynamic interactions on enhancing damping characteristics and improving transient performance of the studied systems is demonstrated using eigenvalue analysis and dynamic time-domain simulations, which validates the validity of the proposed physical mechanism simultaneously.
Źródło:
Archives of Electrical Engineering; 2021, 70, 2; 445-462
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research on emergency DC power support coordinated control for hybrid multi-infeed HVDC system
Autorzy:
Li, Congshan
Li, Yikai
Guo, Jian
He, Ping
Powiązania:
https://bibliotekanauki.pl/articles/140422.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
additional controllers
coordinated control
EDCPS
hybrid multi-infeed HVDC system
HVDC
Opis:
Based on the respective characteristics of line-commutated converter highvoltage direct current (LCC-HVDC) and voltage-source converter high voltage direct current (VSC-HVDC), two additional emergency DC power support (EDCPS) controllers are designed, respectively. In addition a coordinated control strategy based on a hybrid multi-infeed HVDC system for EDCPS is proposed. Considering the difference in system recovery between LCC-HVDC and VSC-HVDC in EDCPS, according to the magnitude of the amount of potential power loss, the LCC-HVDC and VSC-HVDC priority issues of boosting power for EDCPS are discussed in detail. Finally, a hybrid three-infeed HVDC that consists of two parallel LCC-HVDCs and one VSC-HVDC that is built in PSCAD/EMTDC are simulated. The effectiveness of the proposed approach is verified based on this hybrid three-infeed HVDC system.
Źródło:
Archives of Electrical Engineering; 2020, 69, 1; 5-21
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research on improving low-frequency oscillation characteristics of wind power grid-connected power system with doubly-fed wind generator based on virtual impedance power system stabilizer
Autorzy:
He, Ping
Zhu, Yongliang
Li, Qiuyan
Fan, Jiale
Tao, Yukun
Powiązania:
https://bibliotekanauki.pl/articles/27309939.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
doubly-fed induction wind turbine
grid-connected wind power
low frequency oscillation
power system stabilizer
virtual impedance
Opis:
The grid integration of large-scale wind power will alter the dynamic characteristics of the original system and the power distribution among synchronous machines. Meanwhile, the interaction between wind turbines and synchronous machines will affect the damping oscillation characteristics of the system. The additional damping control of traditional synchronous generators provides an important means for wind turbines to enhance the damping characteristics of the system. To improve the low frequency oscillation characteristics of wind power grid-connected power systems, this paper adds a parallel virtual impedance link to the traditional damping controller and designs a DFIG-PSS-VI controller. In the designed controller, the turbine active power difference is chosen as the input signal based on residual analysis, and the output signal is fed back to the reactive power control loop to obtain the rotor voltage quadrature component. With DigSILENT/PowerFactory, the influence of the controller parameters is analyzed. In addition, based on different tie-line transmission powers, the impact of the controller on the low-frequency oscillation characteristics of the power system is examined through utilizing the characteristic root and time domain simulation analysis.
Źródło:
Archives of Electrical Engineering; 2023, 72, 3; 811--826
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Frequency control of voltage sourced converter-based multi-terminal direct current interconnected system based on virtual synchronous generator
Autorzy:
Li, Congshan
Zhang, Xiaowei
He, Ping
Zhen, Zikai
Zhao, Kefeng
Powiązania:
https://bibliotekanauki.pl/articles/27309962.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
adaptive droop control
power margin
VSG
virtual synchronous generator
Opis:
In response to the inability of the flexible DC transmission system connected to the AC grid under conventional control strategies to provide inertia to the system as well as to participate in frequency regulation, a virtual synchronous generator (VSG) control strategy is proposed for a voltage source converter (VSC)-based multi-terminal high-voltage direct current (VSC-MTDC) interconnection system. First, the virtual controller module is designed by coupling AC frequency and active power through virtual inertia control, so that the VSC-MTDC system can provide inertia response for AC grid frequency. Second, by introducing the power margin of the converter station into the droop coefficient, the unbalanced power on the DC side is reasonably allocated to reduce the overshoot of the DC voltage in the regulation process. Finally, the power regulation capability of the normal AC system is used to provide power support to the fault end system, reducing frequency deviations and enabling inter-regional resource complementation. The simulation model of the three-terminal flexible DC grid is built in PSCAD/EMTDC, and the effectiveness of the proposed control strategy is verified by comparing the conventional control strategy and the additional frequency control strategy.
Źródło:
Archives of Electrical Engineering; 2023, 72, 4; 971--986
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Photovoltaic power prediction based on improved grey wolf algorithm optimized back propagation
Autorzy:
He, Ping
Dong, Jie
Wu, Xiaopeng
Yun, Lei
Yang, Hua
Powiązania:
https://bibliotekanauki.pl/articles/27309934.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
BP neural network
photovoltaic power generation
PSO–GWO model
PSO–GWO–BP prediction model
particle swarm optimization
gray wolf optimization
back propagation
standard grey wolf algorithm
Opis:
At present, the back-propagation (BP) network algorithm widely used in the short-term output prediction of photovoltaic power stations has the disadvantage of ignoring meteorological factors and weather conditions in the input. The existing traditional BP prediction model lacks a variety of numerical optimization algorithms, such that the prediction error is large. The back-propagation (BP) neural network is easy to fall into local optimization thus reducing the prediction accuracy in photovoltaic power prediction. In order to solve this problem, an improved grey wolf optimization (GWO) algorithm is proposed to optimize the photovoltaic power prediction model of the BP neural network. So, an improved grey wolf optimization algorithm optimized BP neural network for a photovoltaic (PV) power prediction model is proposed. Dynamic weight strategy, tent mapping and particle swarm optimization (PSO) are introduced in the standard grey wolf optimization (GWO) to construct the PSO–GWO model. The relative error of the PSO–GWO–BP model predicted data is less than that of the BP model predicted data. The average relative error of PSO–GWO–BP and GWO–BP models is smaller, the average relative error of PSO–GWO–BP model is the smallest, and the prediction stability of the PSO–GWO–BP model is the best. The model stability and prediction accuracy of PSO–GWO–BP are better than those of GWO–BP and BP.
Źródło:
Archives of Electrical Engineering; 2023, 72, 3; 613--628
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Improvement of damping characteristics and index evaluation of a wind-PV-thermal-bundled power transmission system by combining PSS and SSSC
Autorzy:
He, Ping
Wu, Xinxin
Li, Congshan
Zheng, Mingming
Li, Zhao
Powiązania:
https://bibliotekanauki.pl/articles/140453.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
damping characteristics
eigenvalue analysis
power system stabilizer
wind-PV-thermal-bundled power system
Opis:
The grid integration of large-scale wind and solar energy affects the power flow of wind-PV-thermal-bundled power transmission systems and may introduce an unpredicted threat to the power system’s small signal stability. Meanwhile, a power system stabilizer (PSS) and static synchronous series compensator (SSSC) play an important role in improving the static and dynamic stability of the system. Based on this scenario and in view of the actual engineering requirements, the framework of wind-PV-thermal-bundled power transmitted by an AC/DC system with the PSS and SSSC is established considering the fluctuation of wind and photovoltaic power output and the characteristics of the PSS and SSSC. Afterwards, the situation model is constructed in the IEEE 2-area 4-unit system, and the influence of the PSS and SSSC on the system stability under different operating conditions is analyzed in detail through eigenvalue analysis and time-domain simulation. Finally, an index named the gain rate is defined to describe the improvement of the stability limitations of various wind-PV-thermal operating conditions with the PSS and SSSC. The results indicate (K) that the damping characteristics, dynamic stability and stability limitations for various wind-PV-thermal operating conditions of the wind-PV-thermal-bundled power transmission system can be significantly improved by the interaction of the PSS and SSSC.
Źródło:
Archives of Electrical Engineering; 2020, 69, 3; 705-721
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
HVDC auxiliary emergency power control strategy for power disturbance in two different positions of AC/DC interconnection system
Autorzy:
Li, Congshan
He, Ping
Wang, Youyi
Ji, Yuyi
Yang, Cunxiang
Powiązania:
https://bibliotekanauki.pl/articles/141502.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
unbalanced power
emergency control
power angle stability
frequency stability
control logic
Opis:
High voltage direct current (HVDC) emergency control can significantly improve the transient stability of an AC/DC interconnected power grid, and is an important measure to reduce the amount of generator and load shedding when the system fails. For the AC/DC interconnected power grid, according to the location of failure, disturbances can be classified into two categories: 1) interconnected system tie-line faults, which will cause the power unbalance at both ends of the AC system, as a result of the generator rotor acceleration at the sending-end grid and the generator rotor deceleration at the receiving-end grid; 2) AC system internal faults, due to the isolation effect of the DC system, only the rotor of the generator in the disturbed area changes, which has little impact on the other end of the grid. In view of the above two different locations of disturbance, auxiliary power and frequency combination control as well as a switch strategy, are proposed in this paper. A four-machine two-area transmission system and a multi-machine AC/DC parallel transmission system were built on the PSCAD platform. The simulation results verify the effectiveness of the proposed control strategy.
Źródło:
Archives of Electrical Engineering; 2019, 68, 2; 245-263
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Electromechanical transient modeling of energy storage based on virtual synchronous machine technology
Autorzy:
Cui, Juntao
Li, Zhao
He, Ping
Gong, Zhijie
Dong, Jie
Powiązania:
https://bibliotekanauki.pl/articles/2135738.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
battery energy storage system
electromechanical transient model
virtual synchronous machine
Opis:
This paper proposes an electromechanical transient method to build a battery energy storage system-based virtual synchronous generator model, suitable for a large-scale grid. This model consists of virtual synchronous generator control, system limitation and the model interface. The equations of a second-order synchronous machine, the characteristics of charging/discharging power, state of charge, operating efficiency, dead band and inverter limits are also considered. By equipping the energy storage converter into an approximate synchronous voltage source with an excitation system and speed regulation system, the necessary inertia and damping characteristics are provided for the renewable energy power system with low inertia and weak damping. Based on the node current injection method by the power system analysis software package (PSASP), the control model is built to study the influence of different energy storage systems. A study on the impact of renewable energy unit fluctuation on frequency and the active power of the IEEE 4-machine 2-area system is selected for simulation verification. Through reasonable control and flexible allocation of energy storage plants, a stable and friendly frequency environment can be created for power systems with high-penetration renewable energy.
Źródło:
Archives of Electrical Engineering; 2022, 71, 3; 581--599
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research on creep-fatigue model of anchored jointed rock mass
Autorzy:
Song, Yang
Fan, Bo
Li, Yong-Qi
Wang, He-Ping
Powiązania:
https://bibliotekanauki.pl/articles/2200878.pdf
Data publikacji:
2023
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
shear creep
anchored jointed rock mass
fractional order
fatigue load
damage
Opis:
To explore the mechanical response of anchored rock mass with an interaction of fatigue and creep, this paper selects the fatigue amplitude and fatigue frequency as influencing factors to carry out a fatigue-creep experiment of the anchored rock mass. Based on fractional order theory and binary perturbation theory, a new fractional order creep model is constructed. The results show that compared with the Burgers model, the newly proposed creep model can better describe the whole process of creep deformation of the anchored jointed rock mass under fatigue loading.
Źródło:
Journal of Theoretical and Applied Mechanics; 2023, 61, 1; 163--173
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An approach to suppress low-frequency oscillation in the hybrid multi-Infeed HVDC of mixed H2/H∞ robust-based control theory
Autorzy:
Li, Congshan
Liu, Yan
Li, Yikai
He, Ping
Fang, Yan
Sheng, Tingyu
Powiązania:
https://bibliotekanauki.pl/articles/2042784.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
additional damping controller
CSP
HMIDC
LFO
mixed 2/∞ control
TLS-ESPRIT
Opis:
A hybrid multi-infeed HVDC (HMIDC) system is composed of line-commutated converter-based high-voltage direct current (LCC-HVDC) and voltage-source converterbased high-voltage direct current (VSC-HVDC), whose receiving ends have electrical coupling. To solve the problem of low-frequency oscillation (LFO) caused by insufficient damping in the HMIDC system, according to the multi-objective mixed 2/∞ output feedback control theory with regional pole assignment, an additional robust damping controller is designed in this paper, which not only has good robustness, but also has strong adaptability to the change of system operation mode. In the paper, the related oscillation modes and transfer function of the controlled plant are obtained, which are identified by the total least squares estimation of signal parameters via rotary invariance technology (TLS-ESPRIT). In addition, the control-sensitive point (CSP) for suppressing LFO based on the small disturbance test method is determined, which is suitable for determining the installation position of the controller. The results show that the control sensitivity factor of VSC-HVDC is greater than that of LCC-HVDC so that adding an additional damping controller to VSC-HVDC is better than LCC-HVDC in suppressing the LFO of HMIDC. Finally, a hybrid double infeed DC transmission system with three receiving terminals is built on PSCAD/EMTDC where the time-domain simulations are performed to verify the correctness of the CSP selection and the effectiveness of the controller.
Źródło:
Archives of Electrical Engineering; 2022, 71, 1; 109-124
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of oleic acid in different solvent media on BRL 3A cell growth and viability
Autorzy:
Liu, Runqi
Yang, Wei
Xia, Cheng
Chen, Yuanyuan
Gao, Sansi
Dong, Zhihao
Huang, Baoyin
Li, Ruirui
He, Ping
Xu, Chuang
Powiązania:
https://bibliotekanauki.pl/articles/1038377.pdf
Data publikacji:
2018
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
oleic acid
non-alcoholic fatty liver disease
liver lipid deposition
Opis:
Oleic acid (OA) is widely used in pathology studies of hepatocellular lipid deposition. Identifying the effects of different solvents on OA-induced liver lipid deposition would be beneficial for studies on hepatocytes. We treated BRL 3A cells with OA dissolved in different solvents. After 12 h incubation, cell viability was assessed using MTT assays. Reactive oxygen species (ROS), triglyceride (TG) and total cholesterol (TC) counts, and the expression level of glucose regulated protein (GRP78), sterol regulatory element binding protein (SREBP-1C) and fatty acid synthase (FAS) were analyzed. Water, PBS and DMSO were disadvantageous to the dissolution of OA and did not cause an OA-induced response in hepatocytes. In the alcohol+OA-treated cells, the severe ER stress, oxidative stress and cellular fat deposition were significantly increased. BSA promoted cell growth and the cells treated with 1.2% BSA+OA showed a lower grade TG and endoplasmic reticulum stress compared with KOH+OA and alcohol+OA treatments. KOH had no significant influence on BRL 3A cells viability. When treated with OA dissolved in KOH, BRL 3A cells showed a typical hepatocyte damage. KOH was considered the suitable choice for an OA solvent for BRL 3A cells in hepatic lipidosis research.
Źródło:
Acta Biochimica Polonica; 2018, 65, 3; 443-447
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Improved upper bounds for nearly antipodal chromatic number of paths
Autorzy:
Shen, Yu-Fa
Zheng, Guo-Ping
He, Wen-Jie
Powiązania:
https://bibliotekanauki.pl/articles/743717.pdf
Data publikacji:
2007
Wydawca:
Uniwersytet Zielonogórski. Wydział Matematyki, Informatyki i Ekonometrii
Tematy:
radio colorings
nearly antipodal chromatic number
paths
Opis:
For paths Pₙ, G. Chartrand, L. Nebeský and P. Zhang showed that $ac'(Pₙ) ≤ \binom{n-2}{2} + 2$ for every positive integer n, where ac'(Pₙ) denotes the nearly antipodal chromatic number of Pₙ. In this paper we show that $ac'(Pₙ) ≤ \binom{n-2}{2} - n/2 - ⎣10/n⎦ + 7$ if n is even positive integer and n ≥ 10, and $ac'(Pₙ) ≤ \binom{n-2}{2} - (n-1)/2 - ⎣13/n⎦ + 8$ if n is odd positive integer and n ≥ 13. For all even positive integers n ≥ 10 and all odd positive integers n ≥ 13, these results improve the upper bounds for nearly antipodal chromatic number of Pₙ.
Źródło:
Discussiones Mathematicae Graph Theory; 2007, 27, 1; 159-174
2083-5892
Pojawia się w:
Discussiones Mathematicae Graph Theory
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
In vitro co-stimulation of anti-tumor activity by soluble B7 molecules
Autorzy:
He, Wei
Hu, Zhong-Bo
Liu, Fang
Feng, Xian-Qi
Zou, Ping
Powiązania:
https://bibliotekanauki.pl/articles/1041178.pdf
Data publikacji:
2006
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
immunotherapy
tumor escape
gene fusion
recombinant fusion proteins
Opis:
In order to investigate the anti-tumor activity of a soluble B7-1/immunoglobulin G fusion protein and explore an effective method to eliminate immune escape of tumor cells, a recombinant vector encoding this fusion protein was constructed and constitutively expressed in Chinese hamster ovary cells. After purification with protein G affinity chromatography, the soluble fusion protein was tested for bioactivity. Results showed that the fusion protein could significantly increase the density of B7-1 molecules on WEHI-3 cells, a mouse leukemia cell line. Through allogeneic mixed lymphocyte tumor cultures, it was demonstrated that, with the presence of the first signal, it could also significantly enhance T cell activation and killing activity against WEHI-3 cells and interleukin-2 secretion by activated mouse T lymphocytes. The conclusion can be drawn that the soluble B7-IgG fusion protein has a potent capacity to generate or enhance anti-tumor immune response in vitro, and its clinical value deserves further investigation.
Źródło:
Acta Biochimica Polonica; 2006, 53, 4; 807-813
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of socio-economic spatial structure of urban agglomeration in China based on spatial gradient and clustering
Autorzy:
He, Li
Tao, Jian’ge
Meng, Ping
Chen, Dan
Yan, Meng
Vasa, László
Powiązania:
https://bibliotekanauki.pl/articles/19233717.pdf
Data publikacji:
2021
Wydawca:
Instytut Badań Gospodarczych
Tematy:
economic and social development
urban agglomeration
Central Plains Urban Agglomeration (CPUA)
clustering
spatial gradient
Opis:
Research background: Previous studies on the economic and social development of urban agglomerations mostly focus on a single primacy comparative analysis and efficiency evaluation. Spatial structure differentiation is an important feature of urban agglomeration. The lack of economic and social analysis on the spatial structure makes it impossible to determine the development positioning of each city in the urban agglomeration, which affects the sustainable economic development ability of these areas. Purpose of the article: The objective of the article is to analyze the spatial development law and experience of urban agglomeration, this study explores the practice of economic and population spatial structure of city areas in China. For this purpose, CPUA and its central city Zhengzhou was taken as an example, the spatial gradient structure of example was analyzed. Methods: Using economic and population data of 32 cities in this region, growth pole theory, and pole-axis theory, the economic and population spatial structure of urban agglomeration, the spatial gradient structure of central cities in urban agglomerations were analyzed with the method of cluster about radiation index. Findings & value added: (1) In the process of the formation of CPUA, the geo-graphical spatial pattern plays a decisive role in economic and social development. This is an experience from developing countries. (2) CPUA presents a gradient development pattern with Zhengzhou as the center, and economic and social development gradually radiates to the metropolitan area, the core development area, and the character development demonstration area. (3) The economic and social gradients of Zhengzhou, the central city, present the hierarchy rules and characteristics which are driven by the Beijing-Guangzhou-Railway axis and the Longhai-Railway axis. (4) The central city of Zhengzhou still presents insufficient primacy in regional development, which shows that Zhengzhou accounts for 6% of the population of the Central Plains Economic Zone and 14% of GDP, and insufficient agglomeration. Different countries at different stages of economic development have different urban agglomeration development models. The conclusions from China provide new decision-making ideas and methods for spatial structure research and development strategy analysis of urban agglomerations.
Źródło:
Oeconomia Copernicana; 2021, 12, 3; 789-819
2083-1277
Pojawia się w:
Oeconomia Copernicana
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Flotation separation of wolframite from quartz using N-oleoyl sarcosine acid as collector
Autorzy:
Xian-Ping, L.
Feng, B.
Xianwen, Z.
Li-Yying, L.
Zheng-He, X.
Powiązania:
https://bibliotekanauki.pl/articles/109444.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
flotation
N-oleoyl sarcosine acid
wolframite
quartz
Opis:
In this study the collecting power of N-oleoyl sarcosine acid towards wolframite and quartz was studied using flotation. The adsorption mechanism was also discussed based on the results from adsorption experiments, zeta potential measurements and infrared spectroscopy study. The flotation results showed that N-oleoyl sarcosine acid showed a good collecting power towards wolframite, and the optimal flotation pH = 7 was obtained. However, the collecting power of N-oleoyl sarcosine acid towards quartz was weak. Therefore, the flotation separation of wolframite from quartz can be performed using N-oleoyl sarcosine acid as a collector. The adsorption tests and electrokinetic studies showed that N-oleoyl sarcosine acid adsorbed only on the wolframite surface. Additionally, the results from the infrared spectroscopy study confirmed that N-oleoyl sarcosine acid is adsorbed on the wolframite surface, and the metal complex (ferriccarboxylate) maybe the major adsorbed species.
Źródło:
Physicochemical Problems of Mineral Processing; 2017, 53, 1; 34-41
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies