Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Hajji, Sara" wg kryterium: Autor


Wyświetlanie 1-3 z 3
Tytuł:
Assessment of Trace Metal Concentrations in Three Seafood Deep-Sea Fished Caught in the Moroccan Atlantic
Autorzy:
Akhouchal, Ihya
Ait Alla, Aicha
Hajji, Sara
Agnaou, Mustapha
Moukrim, Abdellatif
Powiązania:
https://bibliotekanauki.pl/articles/1955583.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
cephalopod
shrimp
fish
metallic trace element
deep sea fishing
food safety
validation of control measure
Opis:
The investigation within the framework of this study was carried out on three marine species fished off in Moroccan coasts, namely: a fish, the sole (Solea Vulgaris), a cephalopod, the cuttlefish (Sepia Officinalis) and a crustacean, the pink shrimp (Parapenaeus Longirostris). The aims of this study were assessing the level of concentration in these three marine species, of three metallic trace elements: lead (Pb), cadmium (Cd) and mercury (Hg) and giving a reflection on the way in which Moroccan deep-sea fishing professionals can join a food safety management system to ensure the safety of their product and promote their competitiveness. Sampling was carried out at the port of Agadir city after landing of the deep-sea fishing boats which operate beyond 10 nautical miles, offshoring the seabed of Agadir for pink shrimp (Parapenaeus Longirostris), and in Dakhla city offshore for sole (Solea Vulgaris) and cuttlefish (Sepia Officinalis). Trace metal analysis was performed on individual muscles belonging to the three species. The results of the conducted investigations show that the Pb content varies between 0.01 ppm and 0.27 ppm in Solea Vulgaris; between 0.015 ppm and 0.16 ppm in Sepia Officinalis and between 0.022 ppm and 0.38 ppm for Parapenaeus Longirostris. For Cd, the concentrations vary between 0.0047 ppm and 0.050 ppm in Solea Vulgaris; between 0.0025 ppm and 0.254 ppm in Sepia Officinalis and between 0.0065 ppm and 0.11 ppm in Parapenaeus Longirostris. Concerning Hg, the contents vary between 0.0006 ppm and 0.075 ppm in Solea Vulgaris; between 0.0008 ppm and 0.05 ppm in Sepia Officinalis and between 0.0016 ppm and 0.09 ppm in Parapenaeus Longirostris. It appears from this study that the metal contents detected at the level of the three species of seafood investigated are below the regulatory thresholds. These results can be considered as the first basis for validating the control measure linked to the absence of metallic contamination of the three species in the sites studied.
Źródło:
Journal of Ecological Engineering; 2021, 22, 9; 87-98
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of Physicochemical and Bacteriological Quality of Treated Wastewater by the New Aourir Plant (Southwestern of Morocco) Using Activated Sludge Technology in a Semi-Arid Region
Autorzy:
Hajji, Sara
Ait Alla, Aicha
Noureddine, Slimani
Haddad, Mohamed Ben
Moukrim, Abdellatif
Powiązania:
https://bibliotekanauki.pl/articles/1838277.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
wastewater
Morocco
physicochemical parameter
activated sludge
Aourir
bacteriological parameter
treatment plant
Opis:
In order to use the purified wastewater for the irrigation of a golf course in the Taghazout area (Southwestern of Morocco), this study was conducted to evaluate the physicochemical and bacteriological quality of the treated wastewater in the new Aourir plant (Activated Sludge technology). In order to achieve these objectives, three types of water were analyzed: raw water (RW), biologically treated water (BTW) and water treated by ultraviolet radiation (UV-TW). The physicochemical parameters analyzed were Temperature, pH, Electrical Conductivity (EC), Dissolved Oxygen (DO), Chemical Oxygen Demand (COD), five-day Biological Oxygen Demand (BOD5), Total Suspended Solids (SS), Nitrate (NO3), and Orthophosphates (PO4). Otherwise, the analyzed biological parameters are Total Coliforms (TC), Fecal Coliforms (FC), Escherichia coli (E. coli), and Fecal Streptococci (FS). The physicochemical parameters showed that temperature is always lower than 30°C, the pH is close to neutrality and a strong fluctuation of the high electrical conductivity (2700 μS/cm) occurs in UV-TW. At all stages of wastewater treatment, COD, BOD5, SS, NO3 and PO4 were below the limit values recommended by Moroccan standards. The bacteriological results showed a high level of bacterial contamination in RW and BTW, but in UV-TW the loads did not exceed 3 log10. The average loads of TC, FC, E. coli and FC in UV-TW were 2.13, 1.67, 1.77, and 2 (log10 CFU/100ml) respectively. Activated sludge treatment combined with UV has demonstrated sufficient quality to reuse treated water in irrigation; however, the UV treatment requires control to avoid any effect on the microbiological and physicochemical quality of green spaces and groundwater.
Źródło:
Journal of Ecological Engineering; 2021, 22, 6; 83-98
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of Physicochemical and Bacteriological Quality of Treated Wastewater by the New Aourir Plant (Southwestern of Morocco) Using Activated Sludge Technology in a Semi-Arid Region
Autorzy:
Hajji, Sara
Ait Alla, Aicha
Noureddine, Slimani
Haddad, Mohamed Ben
Moukrim, Abdellatif
Powiązania:
https://bibliotekanauki.pl/articles/1838386.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
wastewater
Morocco
physicochemical parameter
activated sludge
Aourir
bacteriological parameter
treatment plant
Opis:
In order to use the purified wastewater for the irrigation of a golf course in the Taghazout area (Southwestern of Morocco), this study was conducted to evaluate the physicochemical and bacteriological quality of the treated wastewater in the new Aourir plant (Activated Sludge technology). In order to achieve these objectives, three types of water were analyzed: raw water (RW), biologically treated water (BTW) and water treated by ultraviolet radiation (UV-TW). The physicochemical parameters analyzed were Temperature, pH, Electrical Conductivity (EC), Dissolved Oxygen (DO), Chemical Oxygen Demand (COD), five-day Biological Oxygen Demand (BOD5), Total Suspended Solids (SS), Nitrate (NO3), and Orthophosphates (PO4). Otherwise, the analyzed biological parameters are Total Coliforms (TC), Fecal Coliforms (FC), Escherichia coli (E. coli), and Fecal Streptococci (FS). The physicochemical parameters showed that temperature is always lower than 30°C, the pH is close to neutrality and a strong fluctuation of the high electrical conductivity (2700 μS/cm) occurs in UV-TW. At all stages of wastewater treatment, COD, BOD5, SS, NO3 and PO4 were below the limit values recommended by Moroccan standards. The bacteriological results showed a high level of bacterial contamination in RW and BTW, but in UV-TW the loads did not exceed 3 log10. The average loads of TC, FC, E. coli and FC in UV-TW were 2.13, 1.67, 1.77, and 2 (log10 CFU/100ml) respectively. Activated sludge treatment combined with UV has demonstrated sufficient quality to reuse treated water in irrigation; however, the UV treatment requires control to avoid any effect on the microbiological and physicochemical quality of green spaces and groundwater.
Źródło:
Journal of Ecological Engineering; 2021, 22, 6; 83-98
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies