Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Grygier, D." wg kryterium: Autor


Tytuł:
Modification of Heat Treatment Parameters for Pearlite Steel Intended for Cold Plastic Working
Autorzy:
Grygier, D.
Powiązania:
https://bibliotekanauki.pl/articles/99395.pdf
Data publikacji:
2016
Wydawca:
Wrocławska Rada Federacji Stowarzyszeń Naukowo-Technicznych
Tematy:
drawing
pearlite
cementite
coagulation
tempering
Opis:
One of the problems widely discussed in the relevant literature is the fatigue cracking of pearlite steel subjected to cold plastic working, as well as of that being currently in operation. Studies presented in the work were aimed at selection of the parameters, and mainly the time, of heat treatment operations of pearlite steel enabling obtaining cold drawn wires characterised with better plastic properties and higher fatigue resistance than the products achieved during standard processes. The idea of modification was based at possibility of obtaining steel of the sorbite, which are a mixture of ferrite and dispersion cementite of high degree of coagulation. The structures obtained with this method, as being globular, should be featured with better plastic properties than the lamellar structures created during standard diffusion transformation of austenite. In addition the discussed change was to enable decreasing the total surface of interphase boundaries at which the highest delaminations of structure were observed, regardless of whether the cause of the change resulted from presence of non-metallic inclusions or pile-up of dislocations.
Źródło:
Journal of Machine Engineering; 2016, 16, 2; 44-51
1895-7595
2391-8071
Pojawia się w:
Journal of Machine Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the causes of damage to the wires of the steel belt of car tires
Autorzy:
Grygier, D.
Powiązania:
https://bibliotekanauki.pl/articles/1190015.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
ogumienie
pas napędowy
stal perlityczna
cementyt
tire
belt
pearlitic steel
cementite
Opis:
The main when buying car tires we would like them to serve us as long as possible while the experts recommend their replacement after six years at the latest – is it really necessary? In this work the analysis of the impact of car tires operation on microstructure of the steel belt wires has been presented. The results of the presented research have proven that as a result of the complex stresses in the belt wire material the transverse cracks of individual cementite lamellae appear. The observed structural changes are a major cause of fatigue cracks development and finally result in breaking continuity of steel belt wires, breakthrough of the rubber layer and eventually damage to the tires, preventing their further work.
Źródło:
Interdisciplinary Journal of Engineering Sciences; 2016, 4, 1; 45--49
2300-5874
Pojawia się w:
Interdisciplinary Journal of Engineering Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effectiveness of recrystallization high carbon steel with regard to the condition of material
Autorzy:
Grygier, D.
Powiązania:
https://bibliotekanauki.pl/articles/1190026.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
rekrystalizacja
cementyty
stal perlityczna
starzenie
recrystallization
pearlitic steel
annealing
cementite
Opis:
The main aim of the studies presented in paper was to optimize the parameters of the recrystallisation annealing process used in the course of cold plastic working of high carbon steel for patented wires. Object of the research described in the work was eutectoid steel of 0,8% content of C designated for production of colddrawn wires applied for reinforcement of car tires, hoses and ropes. The results of tests show that the condition of the material and mainly degree of plastic deformation has a clearly influence on the effectiveness of pearlitic steel recrystallisation.
Źródło:
Interdisciplinary Journal of Engineering Sciences; 2015, 3, 1; 20--24
2300-5874
Pojawia się w:
Interdisciplinary Journal of Engineering Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The impact of operation of elastomeric track chains on the selected properties of the steel cord wires
Wpływ eksploatacji gąsienic elastomerowych na wybrane własności drutów stalowego kordu
Autorzy:
Grygier, D.
Powiązania:
https://bibliotekanauki.pl/articles/1365614.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
elastomeric track
cord
pearlitic steel
gąsienica elastomerowa
kord
stal perlityczna
Opis:
The track running systems enable movement of heavy vehicles on unpaved and rough terrain, snow-covered, marshy or swampy surfaces, as well as overcoming natural or artificial barriers. The important structural component of the elastomeric tracks is a steel cord sunk in the elastomer creating the tread with the purpose of stiffening the structure, maintaining its proper deflection and giving the adequate resistance to tensile forces. The results of the studies presented in the work have shown that operation of the elastomeric track chains in conditions where they are continuously exposed to contact with foundation, frequent braking and bumping against roughness lead to damage of the steel cord material and a change in its mechanical properties.
Gąsienicowe układy bieżne umożliwiają poruszanie się ciężkich pojazdów po powierzchniach nieutwardzonych oraz w trudnym terenie, zaśnieżonym, bagnistym lub grząskim, a także pokonywanie przeszkód naturalnych i sztucznych. Ważnym elementem konstrukcyjnym gąsienic elastomerowych jest stalowy kord, zatopiony w elastomerze tworzącym rzeźbę bieżnika, ma on na celu usztywnienie konstrukcji, zachowanie jej właściwego ugięcia oraz nadanie odpowiedniej odporności na siły rozciągające. Wyniki badań prezentowanych w pracy wykazały, że eksploatacja gąsienic elastometrowych w warunkach, w których narażone są na ciągłą styczność z podłożem, częste hamowanie oraz uderzenia w nierówności prowadzi do uszkadzania materiału stalowego kordu i zmiany jego własności mechanicznych.
Źródło:
Eksploatacja i Niezawodność; 2017, 19, 1; 95-101
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena powtarzalności czystości metalurgicznej łuków ortodontycznych
The analysis of metallurgical purity repeatability of orthodontic wires
Autorzy:
Koczkodon, K.
Grygier, D.
Powiązania:
https://bibliotekanauki.pl/articles/99126.pdf
Data publikacji:
2018
Wydawca:
Politechnika Śląska. Katedra Biomechatroniki
Tematy:
biomateriał
łuk ortodontyczny
wtrącenia niemetaliczne
biomaterial
orthodontic wire
non-metallic inclusions
Opis:
Materiały metaliczne przeznaczone do produkcji aparatów ortodontycznych powinny posiadać następujące cechy: wysokie właściwości mechaniczne i fizykochemiczne, biokompatybilność i jednorodność struktury. Bardzo ważnym aspektem jest również ich stopień zanieczyszczenia wtrąceniami niemetalicznymi. Wyniki badań prezentowanych w pracy wykazały dużą różnorodność w zakresie czystości metalurgicznej materiału badanych drutów, mogącej wskazywać, iż w analizowanej partii łuków znajdują się produkty pochodzące z różnych wytopów, znacząco różniące się jakością wykonania.
The metallic materials designed to production of braces possess following features: high mechanical and physicochemical proprieties, biocompatibility and homogeneity of structure. Very important point is also degree non-metallic inclusion. The results of investigations presented in work show the large diverseness of metallurgical cleanness of studied wires material, which lead that various product could coming from different melting, non-uniform with quality of realization.
Źródło:
Aktualne Problemy Biomechaniki; 2018, 15; 13-20
1898-763X
Pojawia się w:
Aktualne Problemy Biomechaniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza zmian komórkowych zachodzących w naczyniach wieńcowych po implantacji stentu
Molecular reponse of vascular heart system after stent implantation
Autorzy:
Grygier, D.
Kuropka, P.
Dudziński, W.
Powiązania:
https://bibliotekanauki.pl/articles/285067.pdf
Data publikacji:
2007
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
stenty wieńcowe
coronary stents
Źródło:
Engineering of Biomaterials; 2007, 10, no. 65-66; 37-39
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The effect of titanum dioxide modification on the copper powder bactericidal properties
Autorzy:
Rutkowska-Gorczyca, M.
Molska, J.
Grygier, D.
Powiązania:
https://bibliotekanauki.pl/articles/286201.pdf
Data publikacji:
2018
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
titanum dioxide
copper
batericidal properties
Źródło:
Engineering of Biomaterials; 2018, 21, 148; 95
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Effect of a Change in Recrystallization Annealing Time on the Properties and Structure of Cold-Drawn Wires
Autorzy:
Grygier, D.
Rutkowska-Gorczyca, M.
Dudziński, M.
Powiązania:
https://bibliotekanauki.pl/articles/99719.pdf
Data publikacji:
2015
Wydawca:
Wrocławska Rada Federacji Stowarzyszeń Naukowo-Technicznych
Tematy:
pearlitic steel
annealing
cementite
Opis:
Although many heat treatment schemes have been developed for pearlitic steel, in the literature there is still little information about the influence of the different heat treatment parameters on the percentage, properties and morphology of the phases. Neither there is any information on matching the parameters, taking into account the different degree of deformation of the steel wires, the particular applications and operating conditions of the products. The aim of this research was to optimize the parameters of the interoperation annealing used during the cold plastic work-ing of pearlitic steel intended for cold-drawn wires. The results of the hardness measurements and microscopic observations, presented in this paper clearly show that there is no need to apply long recrystallization treatments to small diameter wires. This finding is highly significant from the economic point of view and it clearly shows the importance of the individual matching of heat treatment parameters to specific industrial applications.
Źródło:
Journal of Machine Engineering; 2015, 15, 1; 90-97
1895-7595
2391-8071
Pojawia się w:
Journal of Machine Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Perspektywy zastosowań technologii zol-żel w zakresie wytwarzania powłok przeznaczonych na pokrycia implantów
The perspective of sol-gel technology in the development of coatings on medical implants
Autorzy:
Grygier, D.
Dudziński, W.
Rutkowska-Gorczyca, M.
Powiązania:
https://bibliotekanauki.pl/articles/970897.pdf
Data publikacji:
2010
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
implanty
technologia zol-żel
powłoki
implants
sol-gel technology
coatings
Źródło:
Engineering of Biomaterials; 2010, 13, no. 96-98; 21-24
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The research methodology of powders with particle size of under 500 microns
Autorzy:
Żegleń, K.
Grygier, D.
Ambroziak, A.
Żak, A.
Powiązania:
https://bibliotekanauki.pl/articles/1190004.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
metodologia
druty proszkowe
proszki
methodology
tubular electrode
powders
Opis:
Wyniki przedstawione w artykule są zobrazowaniem metodologii będącej tematem tej pracy. Zawiera ona opis głównych metod badań jak obserwacje mikroskopowe, analiza sitowa oraz określanie składu chemicznego z wykorzystaniem detektora EDX. Wyniki przedstawiają określenie kształtu cząstek, określenie wielkości cząstek wraz z wyróżnieniem frakcji o największym udziale procentowym oraz określenie składu chemicznego. Celem artykułu jest przedstawienie kolejności wykonywania badań dotyczących proszku żelaza o granulacji do 250 mikrometrów. Badania te można również z powodzeniem zastosować do określania wymienionych wielkości proszków o granulacji do 500 mikrometrów.
Źródło:
Interdisciplinary Journal of Engineering Sciences; 2016, 4, 1; 15--18
2300-5874
Pojawia się w:
Interdisciplinary Journal of Engineering Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Particle size distribution determination methods comparison based on sieve analysis and laser method
Autorzy:
Żegleń, K.
Grygier, D.
Ambroziak, A.
Tulej, M.
Powiązania:
https://bibliotekanauki.pl/articles/1190006.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
analiza sitowa
analiza laserowa
rozkład wielkości cząstek
sieve analysis
laser method
particle size distribution
Opis:
Artykuł prezentuje metody wykonania analizy granulometrycznej. Wśród nich należy wymienić metodę sitową oraz metodę dyfrakcji laserowej (zwanej również metodą laserową). W treści zawarto charakterystykę po szczególnych metod oraz zwrócono uwagę na istotne różnice między nimi. Analizę porównawczą poparto wynikami otrzymanymi z metody sitowej oraz metody laserowej. Przedmiotem badań był proszek żelaza mający zastosowanie przy produkcji rdzeni drutów proszkowych stosowanych do spawania stali. Proszek ten charakteryzuje się wielkością ziaren rzędu 250 mikrometrów.
Źródło:
Interdisciplinary Journal of Engineering Sciences; 2016, 4, 1; 19--23
2300-5874
Pojawia się w:
Interdisciplinary Journal of Engineering Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of selected structural properties of orthodontic arches
Autorzy:
Zięty, A.
Grygier, D.
Detyna, J.
Sarul, M.
Powiązania:
https://bibliotekanauki.pl/articles/284614.pdf
Data publikacji:
2018
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
orthodontic arches
biocompatibility
nickel
Źródło:
Engineering of Biomaterials; 2018, 21, 148; 47
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimization of the inter-operation annealing of cold-drawn eutectoid steels
Autorzy:
Grygier, D.
Rutkowska-Gorczyca, M.
Żak, A.
Jasiński, R.
Powiązania:
https://bibliotekanauki.pl/articles/1075902.pdf
Data publikacji:
2016-10
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
81.05.Bx
81.40.Ef
81.70.Bt
Opis:
The test of the results presented in this paper has demonstrated that the most suitable recrystallizing annealing temperature for cold drawn eutectoid steels is 700°C. The microscopic examinations, with the use of scanning electron microscopy and transmission electron microscopy and the results of mechanical properties tests have shown that only at this temperature it is possible to obtain the fully recrystallized homogeneous fine-grained structure of the pearlitic steel.
Źródło:
Acta Physica Polonica A; 2016, 130, 4; 931-934
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mechaniczne i fizykochemiczne właściwości warstw TiO2
Mechanical and physicochemical properties of titanium dioxide thin films
Autorzy:
Krzak-Roś, J.
Grygier, D.
Baszczuk, A.
Będziński, R.
Powiązania:
https://bibliotekanauki.pl/articles/284866.pdf
Data publikacji:
2007
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
ditlenek tytanu
implanty
implants
titanium dioxide
Źródło:
Engineering of Biomaterials; 2007, 10, no. 67-68; 35-37
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the differentiation of structural and physicochemical properties of orthodontic wires of AISI 304 stainless steel
Autorzy:
Grygier, D.
Hoppe, V.
Zięty, A.
Rutkowska-Gorczyca, M.
Powiązania:
https://bibliotekanauki.pl/articles/284164.pdf
Data publikacji:
2018
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
stainless steel
orthodontics wire
microstructure
Opis:
Wires used for orthodontic arches play a very important role in the process of orthodontic treatment. In combination with the lock attached to the tooth, they move and align the teeth along the set trajectories. Wires of stainless steel are commonly used in orthodontics for several reasons: they are characterised by high resistance to corrosion, high strength and elasticity, formability and a possibility of obtaining defined properties through cold working and annealing during production process. The purpose of the research presented in the work is the analysis of differences of the selected structural properties in the context of corrosion resistance of the orthodontic wire material. The object of the research was edge arches of the 0.016”x0.022” size made of the stainless steel type AISI 304, provided by two different producers: G&H Orthodontics and Adenta. The research methodology involved analysis of chemical and phase composition of the tested alloy, microscopic tests with application of the light and electron microscopy methods, as well as electrochemical direct current measurements. The research presented in the work has shown significant differences in structural and physical-chemical properties of the orthodontic wires made of AISI 304 type stainless steel. Despite the fact, that the tested arches were manufactured of the theoretically the same materials, but by different producers, they significantly differ in chemical composition, metallurgical purity, phase composition and corrosion resistance. In addition, it is worth noticing that the tested materials, in terms of structure, do not meet the normative requirements obligatory for biomaterials.
Źródło:
Engineering of Biomaterials; 2018, 21, 146; 8-13
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies