Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Gruza, M." wg kryterium: Autor


Wyświetlanie 1-8 z 8
Tytuł:
Identification and correction of coordinate measuring machine geometrical errors using lasertracer systems
Autorzy:
Gąska, A.
Gruza, M.
Gąska, P.
Karpiuk, M.
Sładek, J.
Powiązania:
https://bibliotekanauki.pl/articles/103146.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
LaserTracer
coordinate measuring machine
geometrical error
Opis:
LaserTracer (LT) systems are the most sophisticated and accurate laser tracking devices. They are mainly used for correction of geometrical errors of machine tools and coordinate measuring machines. This process is about four times faster than standard methods based on usage of laser interferometers. The methodology of LaserTracer usage to correction of geometrical errors, including presentation of this system, multilateration method and software that was used are described in details in this paper.
Źródło:
Advances in Science and Technology. Research Journal; 2013, 7, 20; 17-22
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of z-axis kinematics influence on measurement result
Autorzy:
Gruza, M.
Harmatys, W
Gąska, P.
Gąska, A.
Sładek, J.
Powiązania:
https://bibliotekanauki.pl/articles/103398.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
CMM accuracy
CMM kinematics
Opis:
CMMs accuracy depend on a number of factors. In spite of using various methods for CMM correction, the differences can be observed in the metrological capability be¬tween the areas in the measuring volume of CMM. Authors attempted to estimate the impact of one of potential CMM accuracy influencing factors, a CMM Z-axis position during measurement, on measurement result. This article presents performed experi¬ments and obtained results.
Źródło:
Advances in Science and Technology. Research Journal; 2015, 9, 26; 109--112
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of temperature impact on cmm residual kinematic errors distribution
Autorzy:
Harmatys, W
Gąska, P.
Gąska, A
Gruza, M.
Sładek, J.
Powiązania:
https://bibliotekanauki.pl/articles/102879.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
residual errors
CMM correction
Opis:
In case of coordinate machines that use CAA correction matrix, the issue of kine¬matic errors analysis may be based on the determination of residual error distribu¬tion. Temperature changes have an impact on CMM kinematic structure, which may cause the differences in the map of residual errors. As for today, the residual errors were analysed only for the reference temperature. No research was undertaken on the residual errors changes depending on the temperature variations. This paper presents the experiment aimed at residual errors analysis and resulting errors distributions for different temperatures.
Źródło:
Advances in Science and Technology. Research Journal; 2015, 9, 26; 113--117
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Roślinne źródła półproduktów chemicznych i farmaceutycznych. Przykład trójterpenu z kasztanowca
Vegetable sources of semi-finished chemical and pharmaceutical products. Example of triterpene made from chestnut
Autorzy:
Grynkiewicz, G.
Gruza, M.
Jatczak, K
Powiązania:
https://bibliotekanauki.pl/articles/142123.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Przemysłu Chemicznego. Zakład Wydawniczy CHEMPRESS-SITPChem
Tematy:
escyna
saponiny triterpenowe
biologicznie aktywne związki naturalne
metabolity wtórne roślin
leki pochodzenia roślinnego
aescin
triterpene saponins
biologically active natural compounds
secondary metabolites of plants
drugs of vegetable origin
Opis:
Biologicznie aktywne i medycznie użyteczne substancje naturalne pochodzenia roślinnego występują na ogół w wieloskładnikowych grupach związków o podobnych właściwościach chemicznych i fizykochemicznych, co znacznie utrudnia ich izolację, a zwłaszcza oczyszczanie. Lecznicze saponiny kasztanowca, tradycyjnie stosowane w medycynie w postaci złożonej mieszaniny (escyna), są przykładem sytuacji w której właściwości farmakologiczne indywidualnych komponentów. Zaprezentowano jedno z możliwych rozwiązań tego problemu na drodze transformacji chemicznych dostępnego surowca, które umożliwiają otrzymanie kluczowego pentacyklicznego triterpenu – protoescygeniny (PES) w stanie wysokiej czystości chemicznej, w procesie realizowanym w pilotowej skali technicznej. Wskazano możliwości zastosowania PES jako dogodnego półproduktu do syntez saponinomimetyków o zróżnicowanych typach struktury.
Biologically active and medically useful natural substances of vegetable origin usually occur in multi-component groups of compounds with similar chemical and physical properties, which significantly inhibit their isolation, and in particular their purification. Therapeutic chestnut saponins, traditionally used in medicine in the form of complex mixture (aescin), are the example of situation where pharmacological properties of individual components. One of the solutions to this issue was presented, based on chemical transformation of available raw material, allowing production of key pentacyclical triterpene - protoescigenin (PES) of high chemical purity, in the process implemented on pilot scale. Possibilities of using PES as a convenient semi-finished product fin the synthesis of mimetic saponins with varying structures.
Źródło:
Chemik; 2015, 69, 2; 75-80
0009-2886
Pojawia się w:
Chemik
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of measured workpiece’s form errors influence on the accuracy of probe heads used on five-axis measuring systems
Autorzy:
Harmatys, W.
Gąska, A.
Gruza, M.
Gąska, P.
Sładek, J.
Powiązania:
https://bibliotekanauki.pl/articles/102182.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
articulating probe head
five-axis system
accuracy
CMM
Opis:
The five-axis measuring systems are one of the most modern inventions in coordinate measuring technique. They are capable of performing measurements using only the rotary pairs present in their kinematic structure. This possibility is very useful because it may cause significant reduction of total measurement time and costs. However, it was noted that high values of measured workpiece’s form errors may cause significant reduction of the accuracy of a five-axis measuring system. The investigation on the relation between these two parameters was conducted in this paper and possible reasons of decrease in measurement accuracy was discussed on the example of measurements of workpieces with form errors ranging from 0,5 to 1,7 millimetre.
Źródło:
Advances in Science and Technology. Research Journal; 2017, 11, 4; 305-310
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of the impact of probe head hysteresis on the accuracy of five-axis coordinate measuring systems
Autorzy:
Gąska, P.
Gruza, M.
Gąska, A.
Harmatys, W.
Sładek, J.
Powiązania:
https://bibliotekanauki.pl/articles/102633.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
articulating probe head
hysteresis
accuracy
CMM
Opis:
One of the factors affecting the accuracy of Coordinate Measuring Systems is hysteresis of a probe head. It is important especially in case of touch trigger probes and should be taken into account during the determination of probing strategy. In this article, the authors try to assess how this phenomenon affects the accuracy of five axis coordinate systems which utilize articulating probe head. Such systems allow to measure point coordinates using rotary movements of the head what introduces changes to the probing process. The experiments presented in this paper are based on multiple measurements of the reference elements such as gauge blocks and standard ring.
Źródło:
Advances in Science and Technology. Research Journal; 2017, 11, 3; 277-282
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of influence of the parameters connected with the stabilization of the position on the 5-axis manipulators’ operation accuracy
Autorzy:
Gaska, A.
Harmatys, W.
Gruza, M.
Gaska, P.
Sladek, J.
Powiązania:
https://bibliotekanauki.pl/articles/100183.pdf
Data publikacji:
2018
Wydawca:
Wrocławska Rada Federacji Stowarzyszeń Naukowo-Technicznych
Tematy:
pose accuracy
5-axis system
LaserTracer
CMM
Opis:
The 5-axis systems, especially those that use in their kinematic chain both prismatic joints and revolute kinematic pairs are gaining popularity in many scientific disciplines with manufacturing, metrology and robotics at the forefront. This is therefore important to undertake research aiming in identification of sources of inaccuracies in their functioning and investigation on possibility of eliminating or compensating them. A significant impact on 5-axis kinematic structures accuracy may be assigned to parameters associated with the stabilization of the machine position and angular position, such as position stabilization time, position overshoot and drift of positioning accuracy. These parameters are well described in ISO 9283 standard related to performance criteria and test methods for industrial robots. The methodology presented in this standard is adapted for testing the impact of mentioned parameters for functioning of 5-axis kinematic structures other than industrial robots, which mainly include five-axis coordinate measuring systems and machine tools. A series of experiments performed on five-axis coordinate measuring system is presented in this paper, their results are assessed in a quantitative manner and basing on them a general algorithm for assessing the significance of impact of position stabilization parameters on functioning of the manipulator is proposed.
Źródło:
Journal of Machine Engineering; 2018, 18, 2; 54-63
1895-7595
2391-8071
Pojawia się w:
Journal of Machine Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Method for predicting the accuracy of rotational elements measurements using the five-axis coordinate measuring system
Autorzy:
Gaska, P.
Gruza, M.
Harmatys, W.
Gaska, A.
Sladek, J.
Powiązania:
https://bibliotekanauki.pl/articles/99483.pdf
Data publikacji:
2018
Wydawca:
Wrocławska Rada Federacji Stowarzyszeń Naukowo-Technicznych
Tematy:
accuracy
coordinate measuring systems
probing systems
Opis:
The measurements of solids of revolution are one of the most common task in industrial practice. Therefore it is not surprising, that new solutions dedicated to improve accuracy and acceleration of measurements of rotational components are emerging. In this group, the new generation of articulating probing systems (with ability of continuous indexation) is worth mentioning. These probing devices combined with standard CMM forms the five-axis coordinate system. Such solution results in measurements acceleration and also improve measurement repeatability. Studies on this type of probing systems proved that their accuracy depends strongly on the angular orientation of probing system used during measurement. Therefore authors developed model that allows simulation of probing system errors for any orientation. This article describes an attempt to use the model to find the configuration of the probing system that would provide the highest accuracy for rotational elements measurements. The simulation results are compared to the real measurements of standard elements performed on five axis measuring system. Described prediction method could have a beneficial effect on improving the accuracy of measurements and, as a result, on reducing production costs by minimizing the risk of erroneous decision on the conformity of products with their geometric specifications.
Źródło:
Journal of Machine Engineering; 2018, 18, 3; 78-86
1895-7595
2391-8071
Pojawia się w:
Journal of Machine Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies