Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Grabarczyk, Piotr" wg kryterium: Autor


Wyświetlanie 1-4 z 4
Tytuł:
Expression of PiT1 and PiT2 retroviral receptors and transduction efficiency of tumor cells*.
Autorzy:
Grabarczyk, Piotr
Wysocki, Piotr
Gryska, Katarzyna
Mackiewicz, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/1043759.pdf
Data publikacji:
2002
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
renal carcinoma
retroviral vectors
PiT1 and PiT2 retroviral receptors
human melanoma
Opis:
Recombinant retroviral vectors are still the most common gene delivery vehicles for gene therapy purposes, especially for construction of genetically modified tumor vaccines (GMTV). However, these vehicles are characterized by relatively low titre and in the case of many tumor cell lines, low transduction efficiency. We constructed bicistronic retroviral vector pseudotypes of amphotropic murine leukemia virus (A-MuLV) and gibbon ape leukemia virus (GaLV), encoding enhanced green fluorescent protein (EGFP) as a rapid and easily detectable reporter gene. Transduction of five different human melanoma and four renal carcinoma cell lines by these two virus pseudotypes revealed differences in transduction efficiency, which wase markedly lower for the renal carcinoma cell lines. Stimulation of retroviral receptor expression (PiT1 and PiT2) by phosphate depletion induced a limited increase of receptor mRNA levels, but did not improve the gene transfer efficiency. In contrast, simultaneous transduction with both vector pseudotypes markedly increased the transduction efficiency, compared to GaLV or A-MuLV alone. The same effect could be achieved by several repeated exposures of target cells to fresh vector preparation. Overexpression of GaLV receptor (PiT1) in target cells significantly increased the transduction rate and enabled retrovirus mediated gene transfer into the cells which normally are not transducible by GaLV pseudotypes. We demonstrated that, using different transduction strategies, the relatively inefficient, widely used retroviral vector systems could be significantly improved.
Źródło:
Acta Biochimica Polonica; 2002, 49, 2; 333-339
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimization of a retroviral vector for transduction of human CD34 positive cells
Autorzy:
Szyda, Anna
Paprocka, Maria
Krawczenko, Agnieszka
Lenart, Katarzyna
Heimrath, Jerzy
Grabarczyk, Piotr
Mackiewicz, Andrzej
Duś, Danuta
Powiązania:
https://bibliotekanauki.pl/articles/1041181.pdf
Data publikacji:
2006
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
transduction optimization
retroviral vector
CD34+ cells
Opis:
Human stem and progenitor cells have recently become objects of intensive studies as an important target for gene therapy and regenerative medicine. Retroviral vectors are among the most effective tools for genetic modification of these cells. However, their transduction efficiency strongly depends on the choice of the ex vivo transduction system. The aim of this study was to elaborate a system for retroviral vector transduction of human CD34 positive cells isolated from cord blood. The retroviral vector pMINV EGFP was chosen for transduction of two human erythroblastoid cell lines: KG-1a (CD34 positive) and K562 (CD34 negative). For vector construction, three promoters and two retroviral vector packaging cell lines were used. To optimize the physicochemical conditions of the transduction process, different temperatures of supernatant harvesting, the influence of centrifugation and the presence of transduction enhancing agents were tested. The conditions elaborated with KG-1a cells were further applied for transduction of CD34 positive cells isolated from cord blood. The optimal efficiency of transduction of CD34 positive cells with pMINV EGFP retroviral vector (26% of EGFP positive cells), was obtained using infective vector with LTR retroviral promoter, produced by TE FLY GA MINV EGFP packaging cell line. The transduction was performed in the presence of serum, at 37°C, with co-centrifugation of cells with viral supernatants and the use of transduction enhancing agents. This study confirmed that for gene transfer into CD34 positive cells, the detailed optimization of each element of the transduction process is of great importance.
Źródło:
Acta Biochimica Polonica; 2006, 53, 4; 815-823
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the Effectiveness of Active HRD Systems for Dust Explosion Suppression in a Technology Demonstrator System
Ocena skuteczności tłumienia wybuchu pyłowego w układzie demonstratora przez aktywny system HRD
Autorzy:
Lesiak, Piotr
Bąk, Damian
Małozięć, Daniel
Grabarczyk, Marcin
Kołaczkowski, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/2060848.pdf
Data publikacji:
2019
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
HRD
explosion suppression system
dust explosion
system tłumienia wybuchu
wybuch pyłu
Opis:
Purpose: This paper presents the operation of an active dust explosion (HRD, high rate discharge) suppression system in a confined space. Design and methods: The study involved tests of the developed fire protection system for suppressing dust explosions. The work was carried out under the project entitled “Innovative explosion protection technologies, including for highly protected facilities” No. DOBR-BIO4/052/13073/2013 at the Scientific and Research Centre for Fire Protection in Józefów. A test station designed and constructed to meet the prerequisites of the PN-EN 14034 series of standards was designed for testing. The test equipment consisted of a closed roughly spherical chamber with a volume of 1 m3, an ignition system, a system producing a dust-air atmosphere, and a pressure change detection system. Inside the sphere, a dust-air mixture of a certain concentration was obtained in a reproducible manner. The station was armed with a dust explosion suppression system consisting of: – 5 dm3 fire extinguisher tank containing pressurized fire-extinguishing powder, – a diffusing nozzle, – an explosion detection system. The operation of the extinguishing system is based on the early detection of changes in the explosion pressure of the dust-air mixture, the processing of the signal, and the release of the extinguishing agent inside the apparatus in order to interrupt the explosion process at the earliest possible stage of its development. Results: On the basis of the conducted experiments, it can be concluded that the HRD system effectively interrupts explosive combustion for dust with a Kst ≤ 100 bar · m/s. For the examined potato starch dust, the system significantly reduced the explosion pressure to an acceptable value. The system is also characterised by a short reaction time, and the discharge of the extinguishing powder takes place in less than 100 ms, which is a satisfactory value. Conclusions: The tests were carried out for potato starch and lycopodium. The phenomenon of explosive combustion occurring in the mixture of lycopodium and air is characterised by greater dynamics, compared to starch. This difference allowed to identify the limitation of extinguishing dust explosions in small cubic capacity areas. In addition, research identified issues related to the source of ignition in the form of pyrotechnical heads, the use of which requires the setting of a high-pressure threshold activating the HRD system. This results in a delayed system reaction in the event of ignition of high Kst dust mixtures.
Cel: Celem artykułu jest przedstawienie działania aktywnego systemu tłumienia wybuchów pyłowych (nazwanych HRD od ang. high rate discharge) w przestrzeni ograniczonej. Projekt i metody: W ramach badań przeprowadzono testy wytworzonego systemu gaśniczego do tłumienia wybuchów pyłowych. Prace zostały wykonane w ramach projektu pt. „Innowacyjne technologie zabezpieczeń przed wybuchem, w tym obiektów szczególnie chronionych” nr DOBR-BIO4/052/13073/2013 w Centrum Naukowo-Badawczym Ochrony Przeciwpożarowej w Józefowie. Do badań zaprojektowano i wykonano stanowisko spełniające założenia serii norm PN-EN 14034. Urządzenie badawcze składa się z zamkniętej komory kształtem zbliżonej do kuli o objętości 1 m3 oraz układów: zapłonowego, tworzenia atmosfery pyłowo-powietrznej, detekcji zmian ciśnienia. Wewnątrz sfery uzyskiwano w powtarzalny sposób mieszaninę pyłowo-powietrzną o określonym stężeniu. Stanowisko uzbrojono w system tłumienia wybuchów pyłowych zawierający: – zbiornik gaśnicy o objętości 5 dm3 zawierający proszek gaśniczy pod ciśnieniem, – dyszę rozpraszającą, – system wykrywania wybuchu. Działanie systemu gaśniczego opiera się na wczesnym wykryciu zmiany ciśnienia wybuchu mieszaniny pyłowo-powietrznej, przetworzeniu sygnału oraz wyzwoleniu środka gaśniczego do wnętrza aparatu w celu przerwania procesu wybuchu w jak najwcześniejszej fazie jego rozwoju. Wyniki: Na podstawie przeprowadzonych eksperymentów można stwierdzić, że system HRD skutecznie przerywa spalanie wybuchowe dla pyłu o Kst ≤ 100 bar · m/s. Dla przebadanego pyłu skrobi ziemniaczanej system znacznie redukuje ciśnienie wybuchu do wartości akceptowalnej. Układ charakteryzuje się także krótkim czasem reakcji, a wyładowanie proszku gaśniczego następuje w czasie poniżej 100 ms, co jest wartością satysfakcjonującą. Wnioski: Badania przeprowadzono dla skrobi ziemniaczanej i likopodium. Zjawisko spalania wybuchowego zachodzące w mieszaninie likopodium i powietrza charakteryzuje się większą dynamiką niż w przypadku skrobi. Różnica ta pozwoliła na zidentyfikowanie ograniczenia, jakim jest gaszenie wybuchów pyłowych w niewielkiej kubaturze. Ponadto w badaniach zidentyfikowano problematykę związaną z zastosowanym źródłem zapłonu w postaci główek pirotechnicznych, których zastosowanie narzuca konieczność nastawienia wysokiego progu ciśnienia aktywującego system HRD. Skutkuje to opóźnioną reakcją systemu w przypadku zapłonu mieszanin pyłowych o wysokiej wartości parametru Kst.
Źródło:
Safety and Fire Technology; 2019, 53, 1; 46--66
2657-8808
2658-0810
Pojawia się w:
Safety and Fire Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies