Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Gambin, A." wg kryterium: Autor


Wyświetlanie 1-8 z 8
Tytuł:
Temperature Monitoring during Focused Ultrasound Treatment by Means of the Homodyned K Distribution
Autorzy:
Byra, M.
Kruglenko, E.
Gambin, B.
Nowicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/1032313.pdf
Data publikacji:
2017-06
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
temperature monitoring
homodyned K distribution
focused ultrasound
Opis:
Temperature monitoring is essential for various medical treatments. In this work, we investigate the impact of temperature on backscattered ultrasound echo statistics during a high intensity focused ultrasound treatment. A tissue mimicking phantom was heated with a spherical ultrasonic transducer up to 56°C in order to imitate tissue necrosis. During the heating, an imaging scanner was used to acquire backscattered echoes from the heated region. These data was then modeled with the homodyned K distribution. We found that the best temperature indicator can be obtained by combining two parameters of the model, namely the backscattered echo mean intensity and the effective number of scatterers per resolution cell. Next, ultrasonic thermometer was designed and used to create a map of the temperature induced within the tissue phantom during the treatment.
Źródło:
Acta Physica Polonica A; 2017, 131, 6; 1525-1528
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ultrasonic Measurement of Temperature Rise in Breast Cyst and in Neighbouring Tissues as a Method of Tissue Differentiation
Autorzy:
Gambin, B.
Byra, M.
Kruglenko, E.
Doubrovina, O.
Nowicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/177465.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
medical ultrasound
temperature changes in vivo
breast tissue
ultrasonic temperature measurement
Opis:
Texture of ultrasound images contain information about the properties of examined tissues. The analysis of statistical properties of backscattered ultrasonic echoes has been recently successfully applied to differentiate healthy breast tissue from the benign and malignant lesions. We propose a novel procedure of tissue characterization based on acquiring backscattered echoes from the heated breast. We have proved that the temperature increase inside the breast modifies the intensity, spectrum of the backscattered signals and the probability density function of envelope samples. We discuss the differences in probability density functions in two types of tissue regions, e.g. cysts and the surrounding glandular tissue regions. Independently, Pennes bioheat equation in heterogeneous breast tissue was used to describe the heating process. We applied the finite element method to solve this equation. Results have been compared with the ultrasonic predictions of the temperature distribution. The results confirm the possibility of distinguishing the differences in thermal and acoustical properties of breast cyst and surrounding glandular tissues.
Źródło:
Archives of Acoustics; 2016, 41, 4; 791-798
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ultrasonic Synthetic Apertures: Review
Autorzy:
Nowicki, A.
Gambin, B.
Powiązania:
https://bibliotekanauki.pl/articles/176456.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
synthetic aperture
effective aperture
ultrasonography
Opis:
In the paper the concept of synthetic aperture used for high resolution/high frame rate ultrasonic imaging is reviewed. The synthetic aperture technique allows building extended “virtual” apertures, synthesized from smaller real aperture resulting in improved lateral resolution along full penetration depth without sacrificing the frame rate. Especially, four methods, synthetic aperture focusing (SAF), multi-element synthetic aperture focusing (M-SAF), synthetic receive aperture (SRA) and synthetic transmit aperture (STA) are addressed. The effective aperture function, describing two-way, far field radiation is a useful tool in beam pattern analysis. Some basic notations, which are used to calculate the effective aperture are introduced in Appendix.
Źródło:
Archives of Acoustics; 2014, 39, 4; 427-438
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efficient alternatives to PSI-BLAST
Autorzy:
Startek, M.
Lasota, S.
Sykulski, M.
Bułak, A.
Noé, L.
Kucherov, G.
Gambin, A.
Powiązania:
https://bibliotekanauki.pl/articles/201603.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
PSI BLAST tool
sequence alignment
seeding technique
Opis:
In this paper we present two algorithms that may serve as efficient alternatives to the well-known PSI BLAST tool: SeedBLAST and CTX-PSI Blast. Both may benefit from the knowledge about amino acid composition specific to a given protein family: SeedBLAST uses the advisedly designed seed, while CTX-PSI BLAST extends PSI BLAST with the context-specific substitution model. The seeding technique became central in the theory of sequence alignment. There are several efficient tools applying seeds to DNA homology search, but not to protein homology search. In this paper we fill this gap. We advocate the use of multiple subset seeds derived from a hierarchical tree of amino acid residues. Our method computes, by an evolutionary algorithm, seeds that are specifically designed for a given protein family. The seeds are represented by deterministic finite automata (DFAs) and built into the NCBI-BLAST software. This extended tool, named SeedBLAST, is compared to the original BLAST and PSI-BLAST on several protein families. Our results demonstrate a superiority of SeedBLAST in terms of efficiency, especially in the case of twilight zone hits. The contextual substitution model has been proven to increase sensitivity of protein alignment. In this paper we perform a next step in the contextual alignment program. We announce a contextual version of the PSI-BLAST algorithm, an iterative version of the NCBI-BLAST tool. The experimental evaluation has been performed demonstrating a significantly higher sensitivity compared to the ordinary PSI-BLAST algorithm.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2012, 60, 3; 495-505
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sensitivity analysis of mathematical models of signalling pathways
Autorzy:
Charzynska, A.
Nalecz, A.
Rybinski, M.
Gambin, A.
Powiązania:
https://bibliotekanauki.pl/articles/80205.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
membrane receptor
differential equation
stochastic model
modelling
sensitivity analysis
mathematical model
signalling pathway
dynamic behaviour
Źródło:
BioTechnologia. Journal of Biotechnology Computational Biology and Bionanotechnology; 2012, 93, 3
0860-7796
Pojawia się w:
BioTechnologia. Journal of Biotechnology Computational Biology and Bionanotechnology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A stable density approach to probe selection for a custom aCGH design
Autorzy:
Gambin, T.
Stankiewicz, P.
Gambin, A.
Powiązania:
https://bibliotekanauki.pl/articles/81185.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
genomic region
probe
copy number alternation
comparative genomic hybridization
human genome
microarray
wide range application
gene expression
methylation
binding protein
Źródło:
BioTechnologia. Journal of Biotechnology Computational Biology and Bionanotechnology; 2011, 92, 3
0860-7796
Pojawia się w:
BioTechnologia. Journal of Biotechnology Computational Biology and Bionanotechnology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Applying crystallography in analysis of trabecular bone backscatter
Autorzy:
Wojcik, J.
Litniewski, J.
Nowicki, A.
Gambin, B.
Powiązania:
https://bibliotekanauki.pl/articles/332506.pdf
Data publikacji:
2011
Wydawca:
Polskie Towarzystwo Akustyczne
Opis:
Some important details of the Backscatter Effective Cross-Sections obtained for random scattering structures (like trabecular bone) are explain by comparison with the results obtained by means of the simplified theoretical model. The simplified model was (establish) and justified on the basis of the structural analysis of the results obtained for exact model of the field scattering on complex structures. The simplified model is commonly used in description of the scattering on the regular structures like crystal. Comparison with experimental results for the trabecular bone is also presented. The results allowed to conclude that crystallographic methods could be potentially useful for extracting characteristic features of trabecular bone.
Źródło:
Hydroacoustics; 2011, 14; 255-266
1642-1817
Pojawia się w:
Hydroacoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimization algorithm for de novo analysis of tandem mass spectrometry data
Autorzy:
Kistowski, M.
Gambin, A,
Powiązania:
https://bibliotekanauki.pl/articles/80400.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
algorithm
tandem mass spectrometry
analysis
protein identification
post-translational protein modification
amino acid sequence
genetic algorithm
mass spectrometry
liquid chromatography
mutation
crossing-over
Lutefisk algorithm
Źródło:
BioTechnologia. Journal of Biotechnology Computational Biology and Bionanotechnology; 2011, 92, 3
0860-7796
Pojawia się w:
BioTechnologia. Journal of Biotechnology Computational Biology and Bionanotechnology
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies