Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Gajos, K." wg kryterium: Autor


Wyświetlanie 1-14 z 14
Tytuł:
Time Calibration of the J-PET Detector
Autorzy:
Skurzok, M.
Silarski, M.
Alfs, D.
Białas, P.
Shivani, S.
Curceanu, C.
Czerwiński, E.
Dulski, K.
Gajos, A.
Głowacz, B.
Gorgol, M.
Hiesmayr, B.
Jasińska, B.
Kisielewska-Kamińska, D.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krawczyk, N.
Krzemień, W.
Kubicz, E.
Mohammed, Muhsin
Pawlik-Niedźwiecka, M.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Raj, J.
Rudy, Z.
Sharma, N.
Sharma, S.
Shopa, R.
Wieczorek, A.
Wiślicki, W.
Zgardzińska, B.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/1033283.pdf
Data publikacji:
2017-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
06.20.fb
36.10.Dr
11.30.Er
24.80.+y
Opis:
The Jagiellonian positron emission tomograph project carried out in the Institute of Physics of the Jagiellonian University is focused on construction and tests of the first prototype of PET scanner for medical diagnostic which allows for the simultaneous 3D imaging of the whole human body using organic scintillators. The J-PET prototype consists of 192 scintillator strips forming three cylindrical layers which are optimized for the detection of photons from the electron-positron annihilation with high time-and high angular resolutions. In this article we present time calibration and synchronization of the whole J-PET detection system by irradiating each single detection module with a ²²Na source and a small detector providing common reference time for synchronization of all the modules.
Źródło:
Acta Physica Polonica A; 2017, 132, 5; 1641-1644
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of vibration of three-degree-of-freedom dynamical system with double pendulum
Analiza drgań dynamicznego układu z podwójnym wahadłem o trzech stopniach swobody
Autorzy:
Sado, D.
Gajos, K.
Powiązania:
https://bibliotekanauki.pl/articles/281778.pdf
Data publikacji:
2008
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
metoda wielu skal
nieliniowe równania drgań
nonlinear coupled oscillators
autoparametric vibrations
multiple scale method
Opis:
The nonlinear response of a three-degree-of-freedom vibratory system with a double pendulum in the neighborhood of internal and external resonances has been examined. Numerical and analytical methods have been applied for these investigations. Analytical solutions have been obtained by using the multiple scales method. This method is used to construct first-order non- linear ordinary differential equations governing the modulation of amplitudes and phases. Steady state solutions and their stability are computed for selected values of the system parameters.
W pracy przebadano drgania nieliniowego układu o trzech stopniach swobody z podwójnym wahadłem w otoczeniu rezonansów wewnętrznych i zewnętrznych. Badania przeprowadzono analitycznie i numerycznie. Rozwiązanie analityczne uzyskano przy użyciu metody wielu skali czasowych. Metoda posłużyła do zbudowania nieliniowych równań różniczkowych pierwszego rzędu opisujących modulację amplitud i faz. Rozwiązanie ustalone i jego stabilność zostały przedstawione dla wybranych wartości parametrów układu.
Źródło:
Journal of Theoretical and Applied Mechanics; 2008, 46, 1; 141-156
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preliminary studies of J-PET detector spatial resolution
Autorzy:
Pawlik-Niedźwiecka, M.
Niedźwiecki, S.
Alfs, D.
Białas, P.
Curceanu, C.
Czerwiński, E.
Dulski, K.
Gajos, A.
Głowacz, B.
Gorgol, M.
Hiesmayr, B.
Jasińska, B.
Kisielewska, D.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krawczyk, N.
Krzemień, W.
Kubicz, E.
Mohammed, M.
Pałka, M.
Raczyński, L.
Raj, J.
Rudy, Z.
Shivani, -
Silarski, M.
Skurzok, M.
Sharma, N.
Sharma, S.
Shopa, R.
Strzelecki, A.
Wieczorek, A.
Wiślicki, W.
Zgardzińska, B.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/1057928.pdf
Data publikacji:
2017-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
29.40.Mc
87.57.uk
87.10.Rt
34.50.-s
Opis:
The J-PET detector, based on long plastic scintillator strips, was recently constructed at the Jagiellonian University. It consists of 192 modules axially arranged into three layers, read out from both sides by digital constant-threshold front-end electronics. This work presents preliminary results of measurements of the spatial resolution of the J-PET tomograph performed with ²²Na source placed at selected position inside the detector chamber.
Źródło:
Acta Physica Polonica A; 2017, 132, 5; 1645-1648
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
High-density lipoprotein (HDL) cholesterol - more complicated than we think?
Autorzy:
Nessler, K.
Windak, A.
Grzybczak, R.
Nessler, M.B.
Siniarski, A.
Gajos, G.
Powiązania:
https://bibliotekanauki.pl/articles/2081847.pdf
Data publikacji:
2018
Wydawca:
Instytut Medycyny Wsi
Tematy:
cardiovascular disease
diabetes mellitus
dysfunctional HDL
Opis:
Introduction and objective. There are some clinical situations where a high level of HDL cholesterol (HDL-C) may be unfavourable. In these situations, HDL-C may undergo some changes, and even if its quantity is within the reference range, its quality is no longer the same. Brief description of state of knowledge. Diabetes is the state of elevated oxidative stress. Studies conducted to-date have revealed an increased production of the reactive forms of oxygen as the result of tissue damage in diabetes patients. The expression ‘dysfunctional HDL’ has been coined in the literature to describe high-density lipoproteins that lose their antioxidative and anti-inflammatory properties, that is, HDL-C that loses its basic functions. Recent observational studies have confirmed that the atheroprotective activity of properly functioning HDL-C is frequently impaired in clinical situations associated with oxidative stress. The presented review lays the foundation for a new approach to understanding how the functional properties of HDL help reduce cardiovascular risk. Conclusions. In the light of presented findings it seems that there is a need to seek a better diagnostic marker than HDL-C level. This study presents some possible directions for future research to bring us closer to the full understanding of the HDL particle and its role in patients with ischemic heart disease and type 2 diabetes.
Źródło:
Annals of Agricultural and Environmental Medicine; 2018, 25, 3; 517-526
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Method to Produce Linearly Polarized Positrons and Positronium Atoms with the J-PET Detector
Autorzy:
Mohammed, Muhsin
Białas, P.
Curceanu, C.
Czerwiński, E.
Dulski, K.
Gajos, A.
Głowacz, B.
Gorgol, M.
Hiesmayr, B.
Jasińska, B.
Kisielewska, D.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krawczyk, N.
Krzemień, W.
Kubicz, E.
Pawlik-Niedźwiecka, M.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Raj, J.
Rudy, Z.
Sharma, N.
Sharma, S.
Shivani, ---
Skurzok, M.
Silarski, M.
Wieczorek, A.
Wiślicki, W.
Zgardzińska, B.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/1030045.pdf
Data publikacji:
2017-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
41.75.Fr
41.75.Ht
77.22.Ej
36.10.Dr
85.75.Mm
87.57.uk
Opis:
A method for creating linearly polarized positrons and ortho-positronium (o-Ps) atoms with the J-PET detector is presented. The unique geometry and properties of the J-PET tomography enable one to design a positron source such that the quantization axis for the estimation of the linear polarization of produced o-Ps can be determined on the event by event basis in a direction of the positron motion. We intend to use ²²Na or other β⁺ decay isotopes as a source of polarized positrons. Due to the parity violation in the beta decay, the emitted positrons are longitudinally polarized. The choice of the quantization axis is based on the known position of the positron emitter and the reconstructed position of the positronium annihilation. We show that the J-PET tomography is equipped with all needed components.
Źródło:
Acta Physica Polonica A; 2017, 132, 5; 1486-1489
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis Framework for the J-PET Scanner
Autorzy:
Krzemień, W.
Gajos, A.
Gruntowski, A.
Stola, K.
Trybek, D.
Bednarski, T.
Białas, P.
Czerwiński, E.
Kamińska, D.
Kapłon, Ł.
Kochanowski, A.
Korcyl, G.
Kowal, J.
Kowalski, P.
Kozik, T.
Kubicz, E.
Moskal, P.
Niedźwiecki, Sz.
Pałka, M.
Raczyński, L.
Rudy, Z.
Salabura, P.
Sharma, N.
Silarski, M.
Słomski, A.
Smyrski, J.
Strzelecki, A.
Wieczorek, A.
Wiślicki, W.
Zieliński, M.
Zoń, N.
Powiązania:
https://bibliotekanauki.pl/articles/1402621.pdf
Data publikacji:
2015-05
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
87.57.nf
87.57.uk
29.85.-c
Opis:
J-PET analysis framework is a flexible, lightweight, ROOT-based software package which provides the tools to develop reconstruction and calibration procedures for PET tomography. In this article we present the implementation of the full data-processing chain in the J-PET framework which is used for the data analysis of the J-PET tomography scanner. The framework incorporates automated handling of PET setup parameters' database as well as high level tools for building data reconstruction procedures. Each of these components is briefly discussed.
Źródło:
Acta Physica Polonica A; 2015, 127, 5; 1491-1494
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Processing optimization with parallel computing for the J-PET scanner
Autorzy:
Krzemień, W.
Bała, M.
Bednarski, T.
Białas, P.
Czerwiński, E.
Gajos, A.
Gorgol, M.
Jasińska, B.
Kamińska, D.
Kapłon, Ł.
Korcyl, G.
Kowalski, P.
Kozik, T.
Kubicz, E.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Rudy, Z.
Rundel, O.
Sharma, N. G.
Silarski, M.
Słomski, A.
Stola, K.
Strzelecki, A.
Trybek, D.
Wieczorek, A.
Wiślicki, W.
Zieliński, M.
Zgardzińska, B.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/148285.pdf
Data publikacji:
2015
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
data aquisition system (DAQ)
parallel computing
TOF-PET
Opis:
The Jagiellonian Positron Emission Tomograph (J-PET) collaboration is developing a prototype time of flight (TOF)-positron emission tomograph (PET) detector based on long polymer scintillators. This novel approach exploits the excellent time properties of the plastic scintillators, which permit very precise time measurements. The very fast fi eld programmable gate array (FPGA)-based front-end electronics and the data acquisition system, as well as low- and high-level reconstruction algorithms were specially developed to be used with the J-PET scanner. The TOF-PET data processing and reconstruction are time and resource demanding operations, especially in the case of a large acceptance detector that works in triggerless data acquisition mode. In this article, we discuss the parallel computing methods applied to optimize the data processing for the J-PET detector. We begin with general concepts of parallel computing and then we discuss several applications of those techniques in the J-PET data processing.
Źródło:
Nukleonika; 2015, 60, No. 4, part 1; 745-748
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Human tissue investigations using PALS technique - free radicals influence
Autorzy:
Jasińska, B.
Zgardzińska, B.
Chołubek, G.
Pietrow, M.
Gorgol, M.
Wiktor, K.
Wysogląd, K.
Białas, P.
Curceanu, C.
Czerwiński, E.
Dulski, K.
Gajos, A.
Głowacz, B.
Hiesmayr, B.
Jodłowska-Jędrych, B.
Kamińska, D.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krawczyk, N.
Krzemień, W.
Kubicz, E.
Mohammed, Muhsin
Pawlik-Niedźwiecka, M.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Rudy, Z.
Sharma, N.
Sharma, S.
Shopa, R.
Silarski, M.
Skurzok, M.
Wieczorek, A.
Wiktor, H.
Wiślicki, W.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/1057941.pdf
Data publikacji:
2017-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
positron annihilation
positronium
free radicals
tissues
uterine leiomyomas
Opis:
The positron annihilation lifetime spectroscopy was applied to the samples of the human uterine leiomyomas and the normal myometrium tissues taken from the selected place of the uterus during a surgery. The method indicated differences in values of the measured positron annihilation lifetime spectroscopy parameters (lifetimes and intensities) between healthy and diseased tissue samples. The additional measurements were performed either in darkness or in presence of visible light which influenced the free radicals present in both kind of tissues and, as a result, made changes in free annihilation and o-Ps decay lifetime and intensity values.
Źródło:
Acta Physica Polonica A; 2017, 132, 5; 1556-1558
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efektywność emisyjna krajów Unii Europejskiej
Emission efficiency of European Union countries
Autorzy:
Gajos, E.
Malazewska, S.
Prandecki, K.
Powiązania:
https://bibliotekanauki.pl/articles/869313.pdf
Data publikacji:
2018
Wydawca:
The Polish Association of Agricultural and Agribusiness Economists
Źródło:
Roczniki Naukowe Stowarzyszenia Ekonomistów Rolnictwa i Agrobiznesu; 2018, 20, 6
1508-3535
2450-7296
Pojawia się w:
Roczniki Naukowe Stowarzyszenia Ekonomistów Rolnictwa i Agrobiznesu
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
National accounting matrix with environmental accounts (NAMEA) an overview of enviromentally extended input-output analysis
NAMEA – national accounting matrix with environmental accounts – studium przepływów międzynarodowych z rozszerzeniem środowiskowym
Autorzy:
Gajos, E.
Prandecki, K.
Powiązania:
https://bibliotekanauki.pl/articles/37767.pdf
Data publikacji:
2016
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Źródło:
Acta Scientiarum Polonorum. Oeconomia; 2016, 15, 4
1644-0757
Pojawia się w:
Acta Scientiarum Polonorum. Oeconomia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Valuation of water use in agriculture – polish example
Autorzy:
Gajos, E.
Prandecki, K.
Powiązania:
https://bibliotekanauki.pl/articles/95786.pdf
Data publikacji:
2018
Wydawca:
Fundacja Ekonomistów Środowiska i Zasobów Naturalnych
Tematy:
zużycie wody
rolnictwo
Polska
wycena
efekt zewnętrzny
water use
agriculture
Polska
valuation
external effect
Opis:
The aim of the study was to propose a method for the valuation of water use in agriculture. Authors proposed an indirect valuation method – the alternative cost of water abstraction based on the cost of water from public supply. It was found, that there are several problems with statistical data on water use in agriculture, e.g. it is mostly estimations and it actually covers water used in agriculture, forestry and fishing. Proposed valuation method was used to valuate water use in Polish agriculture. It was calculated, that that cost equaled to almost PLN 4.5 billion in 2016, which means the cost per farm at the level over PLN 3.2 thousand.
Źródło:
Ekonomia i Środowisko; 2018, 4; 124-132
0867-8898
Pojawia się w:
Ekonomia i Środowisko
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ edukacji pracowników na zachowanie bezpieczeństwa podczas wykonywania prac w strefach gazowo-niebezpiecznych
The influence of employees education on keeping the security during the work in the gas – dangerous zones
Autorzy:
Gajos, D.
Morel, S.
Lepa, K.
Powiązania:
https://bibliotekanauki.pl/articles/136476.pdf
Data publikacji:
2017
Wydawca:
Szkoła Główna Służby Pożarniczej
Tematy:
strefa gazowo-niebezpieczna
edukacja
bezpieczeństwo
gas–dangerous zone
education
safety
Opis:
Strefy gazowo-niebezpieczne to miejsca, gdzie bardzo ważne jest przestrzeganie zasad bezpieczeństwa i higieny pracy. W takich obszarach istnieją specjalne wymagania dotyczące prac. W celu ochrony zdrowia i życia ludzi ważną rolę odgrywa ocena ryzyka, która informuje o podstawowych zagrożeniach i niebezpieczeństwach. Osoby pracujące w tych strefach muszą przejść odpowiednie szkolenia, gdyż ich edukacja ma wpływ na bezpieczną pracę.
The gas – dangerous zones are the places where it is very important to obey the principles of occupational health and safety. In these areas there are special requirements for work. In protecting human health and life it is very important to assess the risk properly. .The assessment informs about the basic dangers and hazards and the persons working in these zones must have the adequate training because their education has a direct impact on safety of their work.
Źródło:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej; 2017, 1, 62; 25-39
0239-5223
Pojawia się w:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of the condition of the selected landslides in the area of Kadzielnia
Badania stanu wybranych osuwisk na terenie Kadzielni
Autorzy:
Duma, P.
Gajos, K.
Gil, M.
Godzisz, B.
Kaleta, D.
Krawczyk, K.
Salamon, M.
Siwiec, K.
Szewczyk, J.
Woś, J.
Powiązania:
https://bibliotekanauki.pl/articles/402519.pdf
Data publikacji:
2016
Wydawca:
Politechnika Świętokrzyska w Kielcach. Wydawnictwo PŚw
Tematy:
landslide movements
laser scanning
determination of displacements
ruchy osuwiskowe
skanowanie laserowe
wyznaczanie przemieszczeń
Opis:
The Kadzielnia nature reserve located in Kielce is a remnant of the long-term exploitation of limestone. The slopes of a former quarry are unstable; landslide processes occur there, posing a threat to humans and disturbing the landscape. This condition requires observation of the changes in order to take preventive measures. The article presents the preliminary results of such observations, performed for four selected landslides in Kadzielnia. While measuring, modern geodetic techniques were applied, including satellite technology, scanning tacheometry and laser scanning. Obtained results indicate slight displacements of the monitored walls over several months. Observations which were made are initiating study on the behavior of the landslides in the area of Kadzielnia, aimed at early detection of threats and enabling taking safety procedures.
Źródło:
Structure and Environment; 2016, 8, 1; 64-73
2081-1500
Pojawia się w:
Structure and Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis Procedure of the Positronium Lifetime Spectra for the J-PET Detector
Autorzy:
Dulski, K.
Zgardzińska, B.
Białas, P.
Curceanu, C.
Czerwiński, E.
Gajos, A.
Głowacz, B.
Gorgol, M.
Hiesmayr, B.
Jasińska, B.
Kisielewska-Kamińska, D.
Korcyl, G.
Kowalski, P.
Kozik, T.
Krawczyk, N.
Krzemień, W.
Kubicz, E.
Mohammed, Muhsin
Pawlik-Niedźwiecka, M.
Niedźwiecki, S.
Pałka, M.
Raczyński, L.
Raj, J.
Rudy, Z.
Sharma, N.
Sharma, S.
Shivani, Shivani
Shopa, R.
Silarski, M.
Skurzok, M.
Wieczorek, A.
Wiślicki, W.
Zieliński, M.
Moskal, P.
Powiązania:
https://bibliotekanauki.pl/articles/1033298.pdf
Data publikacji:
2017-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
07.05.Kf
13.30.Ce
14.60.-z
78.47.-p
Opis:
Positron annihilation lifetime spectroscopy has shown to be a powerful tool to study the nanostructures of porous materials. Positron emission tomograph is a device allowing imaging of metabolic processes e.g. in human bodies. A newly developed device, the Jagiellonian PET will allow positron annihilation lifetime spectroscopy in addition to imaging, thus combining both analyses providing new methods for physics and medicine. In this contribution we present a computer program that is compatible with the Jagiellonian PET software. We compare its performance with the standard program LT 9.0 by using positron annihilation lifetime spectroscopy data from hexane measurements at different temperatures. Our program is based on an iterative procedure, and our fits prove that it performs as good as LT 9.0.
Źródło:
Acta Physica Polonica A; 2017, 132, 5; 1637-1640
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-14 z 14

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies