Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Gajek, Dariusz" wg kryterium: Autor


Wyświetlanie 1-4 z 4
Tytuł:
Snow distribution patterns on Svalbard glaciers derived from radio-echo soundings
Autorzy:
Grabiec, Mariusz
Budzik, Tomasz
Puczko, Dariusz
Gajek, Grzegorz
Powiązania:
https://bibliotekanauki.pl/articles/2051522.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Arctic
pitsbergen
Nordaustlandet
snow accumulation
GPR
Źródło:
Polish Polar Research; 2011, 4; 393-421
0138-0338
2081-8262
Pojawia się w:
Polish Polar Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The vibration energy absorption of tractor operator exposed to vertical whole-body vibration under work of the aggregate tractor-round baler
Absorpcja energii drgań o oddziaływaniu ogólnym przez operatora agregatu ciągnik-prasa zwijająca
Autorzy:
Kromulski, Jacek
Szczepaniak, Jan
Gajek, Dariusz
Mac, Jarosław
Wojciechowski, Jacek
Zawada, Michał
Powiązania:
https://bibliotekanauki.pl/articles/335354.pdf
Data publikacji:
2020
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Maszyn Rolniczych
Tematy:
tractor operator
round baler
whole body vibration
human body model
power
absorption
operator ciągnika
prasa zwijająca
drgania o oddziaływaniu ogólnym
model ciała kierowcy
rozkład mocy drgań
Opis:
Humans are most sensitive to whole body vibration (WBV) within the frequency range of 1 to 20 Hz. Whole-body vibration can cause fatigue, stomach problems, headache. After daily exposure over a number of years, whole-body vibration can affect the entire body and result in a number of health disorders. Workers driving tractors or other vehicles are especially at risk of being exposed to WBV. On the basis of the guidance provided in ISO 2631-1 to relate vibration exposure with the risks of health effects are established based on absorbed power. The 4-DOF dynamic model developed by Wan and Schimmels is recommended for the study of biodynamic responses of seated human subjects under vertical whole body vibration. This model of the human body is used to estimate the absorbed power distributed in head, upper torso, lower torso and thighs. The vibration energy (power) absorption of seated human that is exposed to vertical whole-body vibration are investigated under work of the aggregate tractor-round baler.
Ludzie są najbardziej wrażliwi na drgania o działaniu ogólnym w zakresie częstotliwości od 1 do 20 Hz. Drgania o działaniu ogólnym mogą powodować zmęczenie, problemy żołądkowe, ból głowy. Po codziennej, wieloletniej, ekspozycji na drgania o oddziaływaniu ogólnym może zostać powstać szereg zaburzeń zdrowotnych. Pracownicy prowadzący ciągniki lub inne pojazdy są szczególnie narażeni na kontakt z drganiami o oddziaływaniu ogólnym. Na podstawie wytycznych zawartych w normie ISO 2631-1 istnieje powiązanie narażenia na wibracje z ryzykiem skutków zdrowotnych na podstawie pochłoniętej mocy drgań. Model biodynamiczny o czterech stopniach swobody 4-DOF opracowany przez Wana i Schimmelsa jest zalecany do badania reakcji siedzącego kierowcy na pionowe drgania o oddziaływaniu ogólnym. Model ten pozwala wyznaczyć pochłoniętą moc drgań w poszczególnych elementach ciała człowieka: głowa, górną część tułowia, dolną część tułowia oraz uda. Model ten zastosowano do badania absorpcji mocy drgań przez operatora agregatu ciągnik-prasa zwijająca
Źródło:
Journal of Research and Applications in Agricultural Engineering; 2020, 65, 1; 14-20
1642-686X
2719-423X
Pojawia się w:
Journal of Research and Applications in Agricultural Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
His bundle pacing in patients with permanent atrial fibrillation and heart failure with non-reduced ejection fraction – retrospective study
Autorzy:
Skonieczny, Bartosz
Sławuta, Agnieszka
Radziejewska, Jadwiga
Jagielski, Dariusz
Gajek, Jacek
Kozłowski, Dariusz
Powiązania:
https://bibliotekanauki.pl/articles/24987710.pdf
Data publikacji:
2024-01-08
Wydawca:
Gdański Uniwersytet Medyczny
Tematy:
heart failure
permanent atrial fibrillation
His bundle pacing
Opis:
Background: Heart failure [HF] constitutes a complex clinical entity and often coexists with atrial fibrillation [AF]. There is scarcity of evidence-based therapies for those with ejection fraction [EF] ≥ 40%. Effect of regularization of ventricular response in patients with HF with EF ≥ 40% and concomitant atrial fibrillation is unknown. Material and methods: This was a retrospective case-series study. 14 patients with symptomatic HF with EF ≥ 40% and permanent atrial fibrillation who had undergone pHBP were identified and enrolled. For 9 patients pHBP was a primary strategy, for the remaining patients it was an upgrade from right ventricular lead. All patients underwent follow-up visit 3 months after the procedure. Results: NYHA class was significantly reduced (mean 2.5 vs. 1.0, p-value < 0.001). Left ventricular ejection fraction significantly increased mean increase 8.5%, 95% CI 7.7–9.2, p < 0.001) Similarly, significant decrease in left ventricular end diastolic diameter was observed (mean decrease 5.4 mm, 95% CI 5.0–5.8 mm, p < 0.001). The degree of mitral regurgitation after three months was lower (mean grade 2.4 vs. 1.2, p < 0.001). At follow-up prescribed doses of beta blocker were higher (mean metoprolol equivalent dose rose by 69.6 mg). Conclusions: Permanent His bundle pacing might be beneficial in the setting of permanent AF and HF with EF ≥ 40%.
Źródło:
European Journal of Translational and Clinical Medicine; 2023, 6, 2; 45-50
2657-3148
2657-3156
Pojawia się w:
European Journal of Translational and Clinical Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An echocardiographic tool for the interatrial conduction disorders – old dog, new tricks?
Autorzy:
Zawadzki, Jacek M.
Gajek, Jacek J.
Sławuta, Agnieszka
Kozłowski, Dariusz
Zaborniak, Gabriel
Kudliński, Bartosz
Powiązania:
https://bibliotekanauki.pl/articles/24987707.pdf
Data publikacji:
2024-01-08
Wydawca:
Gdański Uniwersytet Medyczny
Tematy:
ECG
P wave
LA strain
echocardiography
Bachmann's bundle
Opis:
Background: Bachmann’s bundle plays a crucial role in the physiology of interatrial signal conduction. In the 1970s, Bayes de Luna introduced the definition of interatrial blocks (IABs), which negatively influence atrioventricular (AV) synchrony and left atrial (LA) activation. We aimed to assess the potential of LA strain technology in evaluating the mechanics of LA in patients with correct conduction and IABs. Additionally, we measured the parameters of regurgitation in pulmonary veins (PV), which depend on the type of interatrial conduction. Material and methods: The study group comprised 51 patients (26M, 25F) with symptomatic COVID-19 and sinus rhythm. Our study analyzed their medical history, electrocardiography (ECG) and echocardiography, including the LA strain parameters. Results: Global peak atrial longitudinal strain (PALS) depended on P wave duration, LA volume, left ventricular ejection fraction (LV EF) and inferior pulmonary veins (PV) regurgitation parameters. Global peak atrial contractile strain (PACS) statistically depends on the LV EF, LA volume and the P wave morphology. Conclusions: The presence of IABs negatively influences PACS and PALS. Examining LA strain is complementary to accurate ECG, which may be helpful in everyday clinical practice, particularly in diagnosing heart failure with preserved ejection fraction (HFpEF) and as a predictor of new episodes of atrial fibrillation (AF).
Źródło:
European Journal of Translational and Clinical Medicine; 2023, 6, 2; 26-35
2657-3148
2657-3156
Pojawia się w:
European Journal of Translational and Clinical Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies