Tytuł:
Characterization of the ionization process inside a miniature glow-discharge micropump
Autorzy:
Grzebyk, T.
Górecka-Drzazga, A.
Powiązania:
https://bibliotekanauki.pl/articles/200204.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ion-sorption micropump
MEMS-type micropump
gas discharge
ionization
mikropompa jonowo-sorpcyjna
mikropompa typu MEMS
wyładowanie gazu
jonizacja
Opis:
The article presents a detailed characterization of the ionization process taking place inside a miniature MEMS-type ion-sorption vacuum pump, based on the Penning pump architecture. Influence of a variety of parameters on the discharge current has been investigated. These include: magnetic field, type of material used for the electrodes as well as horizontal and vertical dimensions of the micropump. It was found that the micropump works efficiently as long as the magnetic field is higher than 0.3 T, and the pumping cell’s dimensions exceed 1x1x1 mm3. Best results have been obtained for copper and aluminum cathodes and low resistivity silicon anodes.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2018, 66, 2; 173-178
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Vacuum microdevices
Autorzy:
Grzebyk, T.
Górecka-Drzazga, A.
Powiązania:
https://bibliotekanauki.pl/articles/201008.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
vacuum microsystems
miniature vacuum pump
field-emission electron source
MEMS
Opis:
In the paper MEMS-type microsystems working in vacuum conditions are described. All the benefits and drawbacks of vacuum generated in microcavities are discussed. Different methods are used to produce vacuum in microcavity of MEMS. Some bonding techniques, sacrificial layer method or getter materials are presented. It is concluded that the best solution would be to invent some kind of vacuum micropump integrated with MEMS structure. Few types of already existing vacuum micropumps are shown, but they are not able to generate high vacuum. As the most promising candidate for miniaturization an orbitron pump was selected. The working principle and novel concepts of its construction are described. The most important part of the micropump, used for gas ionization, is a field-emission electron source. Results of a research on a lateral electron source with gold emissive layer for integration with a micropump are presented.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2012, 60, 1; 19-23
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Miniaturowy krzemowo-szklany mikrocytometr zintegrowany z miniaturowym źródłem światła
Miniature silicon-glass microcytometer integrated with miniature light source
Autorzy:
Cichy, B.
Górecka-Drzazga, A.
Dziuban, J. A.
Powiązania:
https://bibliotekanauki.pl/articles/157048.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
mikrocytometr
biochip
emisja polowa
polowe źródła światła
zwierzęce oocyty
microcytomete
field emission
field-emission light sources
animal oocytes
Opis:
W pracy przedstawiono krzemowo-szklany chip mikrofluidyczny tzw. mikrocytometr. Jest to miniaturowe urządzenie do analizy parametrów różnych komórek (przepływającego obiektu biologicznego) wprowadzonych do układu mikrokanałów. Prezentowany mikrocytometr przystosowany jest do wprowadzania światła prostopadle do kierunku przepływu badanej próbki. Do oświetlania próbki opracowano miniaturowe krzemowo-szklane źródło światła. Źródło to wykorzystuje emisję polową elektronów z wielościennych nanorurek węglowych oraz wzbudzanie luminescencji w nanokrystalicznym luminoforze tlenkowym. Ze względu na kompatybilność technologiczną obu miniaturowych urządzeń jest możliwa ich pełna integracja. Opracowany chip został zastosowany do analizy właściwości pojedynczych komórek zwierzęcych metodą pomiaru wzbudzonej fluorescencji. Wstępne testy wykazały, że krzemowo-szklany mikrocytometr umożliwia ocenę stanu biologicznego oocytów zwierzęcych poddanych indukowanej apoptozie.
A new silicon-glass microfluidic chip called microcytometer is presented in the paper. It is a miniature device for examining parameters of microscopic particles, such as cells which are suspended in a stream of fluid flowing by microchannel. This chip allows introduction of light beam vertically to the sample flow direction. Miniature light source for lighting the analysed cell was elaborated. The light source makes use of electron emission for cold cathode as an effect of a very high electrical field. Field-emitted electrons from multiwall carbon nanotubes excite luminescence from nanocrystalline oxide phosphors. Because of technological compatibility of both miniature devices, they can be fully integrated. The microcytometer was used for fluorimetric measurements of single living, animal cells. The first results showed that the silicon-glass microcytometer allowed estimation of biological conditions of animal oocytes which were subjected to induced apoptosis.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 5, 5; 437-439
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Electron optics column for a new MEMS-type transmission electron microscope
Autorzy:
Krysztof, M.
Grzebyk, T.
Górecka-Drzazga, A.
Adamski, K.
Dziuban, J.
Powiązania:
https://bibliotekanauki.pl/articles/201167.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
MEMS
miniature TEM
electron emission
focusing of electron beam
electron optics column
emisja elektronów
ogniskowanie
wiązka elektronów
mikrostruktura TEM
Opis:
The concept of a miniature transmission electron microscope (TEM) on chip is presented. This idea assumes manufacturing of a silicon-glass multilayer device that contains a miniature electron gun, an electron optics column integrated with a high vacuum micropump, and a sample microchamber with a detector. In this article the field emission cathode, utilizing carbon nanotubes (CNT), and an electron optics column with Einzel lens, made of silicon, are both presented. The elements are assembled with the use of a 3D printed polymer holder and tested in a vacuum chamber. Effective emission and focusing of the electron beam have been achieved. This is the first of many elements of the miniature MEMS (Micro-Electro-Mechanical System) transmission electron microscope that must be tested before the whole working system can be manufactured.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2018, 66, 2; 133-137
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Field-emission light sources for lab-on-a-chip microdevices
Autorzy:
Górecka-Drzazga, A.
Cichy, B.
Szczepańska, P.
Walczak, R.
Dziuban, J.
Powiązania:
https://bibliotekanauki.pl/articles/201010.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
lab-on-a-chip
field emission
light source
microcytometer
Opis:
Microfluidic devices called lab-on-a-chips utilize two kinds of characterization of a biosample, which are based on spectrofluorimetric and spectrophotometric methodologies. Lab-on-a-chips are equipped with an optical instrumentation and a software system that allow detecting of the optical signals and their processing into spectral characteristics. In the paper, technology of lab-on-a-chip (cytometer microdevice) and miniature silicon-glass field-emission light source (FELS) is described. Electrons emitted from a silicon cathode covered with carbon nanotubes excite light emission from nanocrystalline rare earth doped yttrium oxide phosphor (anode). The emitted light can be precisely tailored to the main absorption line of a fluorescent marker. The presented system has been successfully used for testing of the cow embryos as well as fluorescent-marked porcine oocytes.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2012, 60, 1; 13-17
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies