Tytuł:
The description of the human knee as four-bar linkage
Autorzy:
Dathe, H.
Gezzi, R.
Fiedler, Ch.
Kubein-Meesenburg, D.
Nägerl, H.
Powiązania:
https://bibliotekanauki.pl/articles/307351.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
staw kolanowy
anatomia
kinematyka kolana
human knee
anatomy
knee kinematics
four-bar linkage
analytical description
Opis:
Purpose: We investigate the dependence of the kinematics of the human knee on its anatomy. The idea of describing the kinematics of the knee in the sagittal plane using four-bar linkage is almost as old as kinematics as an independent discipline. We start with a comparison of known four-bar linkage constructions. We then focus on the model by H. Nägerl which is applicable under form closure. Methods: We use geometry and analysis as the mathematical methods. The relevant geometrical parameters of the knee will be determined on the basis of the dimensions of the four-bar linkage. This leads to a system of nonlinear equations. Results: The four-bar linkage will be calculated from the limits of the constructively accessible parameters by means of a quadratic approximation. Conclusions: By adapting these requirements to the dimensions of the human knee, it will be possible to obtain valuable indications for the design of an endoprosthesis which imitates the kinematics of the natural knee.
Źródło:
Acta of Bioengineering and Biomechanics; 2016, 18, 4; 107-115
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The morphology of the articular surfaces of biological knee joints provides essential guidance for the construction of functional knee endoprostheses
Autorzy:
Nagerl, H.
Dathe, H.
Fiedler, Ch.
Gowers, L.
Kirsch, S.
Kubein-Meesenburg, D.
Dumont, C.
Wachowski, M. M.
Powiązania:
https://bibliotekanauki.pl/articles/307060.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
kolano
kinematyka
biomechanika
endoproteza
knee arthroplasty
kinematics
biomechanics
knee
endoprosthesis
pig
Opis:
Purpose: In comparative examinations of kinematics of the knees of humans and pigs in flexional/extensional motion under compressive loads, the significant differential geometric essentials of articular guidance are elaborated to criticise the shaping of the articular surfaces of conventional knee-endoprostheses and to suggest constructional outlines that allow the endoprosthesis to adopt natural knee kinematics. Implantation is discussed with regard to the remaining ligamentous apparatus. Methods: Twelve fresh pig knee joints and 19 preserved human knee joints were moved into several flexional/extensional positions. In each joint, the tibia and femur were repeatably caught by metal plates. After removing all ligaments, the tibia and femur were again caught in these positions, and their points of contact were marked on both articular surfaces. Along the marker points, a thin lead wire was glued onto each surface. The positions and shapes of the four contact lines were mapped by teleradiography. Results: All contact lines were found to be plane curves. The medial and lateral planes were parallel, thus defining the joint’s sagittal plane. In the human knee, as compared to the lateral, the medial femoral contact line was always shifted anteriorly by several millimetres. The tibial contact curve was laterally convex and medially concave. In the pig knees, the lateral and medial contact lines were asymmetrically placed. Both tibial curves were convex. Conclusions: Both knees represent cam mechanisms (with one degree of freedom) that produce rolling of the articular surfaces during the stance phase. Implantation requires preservation of the anterior cruciate ligament, and ligamentous balancing is disadvantageous.
Źródło:
Acta of Bioengineering and Biomechanics; 2015, 17, 2; 45-53
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies