Tytuł:
Strain-dependent damping of Ti-10V-2Fe-3Al at room temperature
Autorzy:
Göken, J.
Fayed, S.
Skubisz, P.
Powiązania:
https://bibliotekanauki.pl/articles/1058185.pdf
Data publikacji:
2016-12
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
61.72.Hh
43.40.Cw
43.58.Fm
Opis:
The Ti-10V-2Fe-3Al alloy is advantageous over other titanium grades due to its high tensile strength and its high resistance against creep, cracking, and corrosion. The investigated alloy was hammer-forged inducing high strain rates in the material at a temperature of 800°C and underwent different cooling procedures. Three in that way thermomechanically treated specimens were prepared for subsequent study of the vibration behaviour of the material with the help of non-destructive, contact-free acoustic measurements. Resulting time-dependent decaying acoustic signals were analysed to investigate the dependence of the material damping behaviour on the individual downstream thermal treatment procedure and, ultimately, on the microstructural changes.
Źródło:
Acta Physica Polonica A; 2016, 130, 6; 1352-1357
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Study on the Correlation between Wood Moisture and the Damping Behaviour of the Tonewood Spruce
Autorzy:
Göken, J.
Fayed, S.
Schäfer, H.
Enzenauer, J.
Powiązania:
https://bibliotekanauki.pl/articles/1030781.pdf
Data publikacji:
2018-05
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
spruce wood
musical instruments
wood moisture
damping measurement
Opis:
In acoustic musical instruments special attention needs to be paid to those particularly sensitive parts made of tonewood whose function is to respond to vibrations. One of the most important tonewoods is spruce because of its good resonance properties. Spruce is especially used for soundboards, these being the primary source of sound. Piano manufacturers dry their soundboards to approximately 6% wood moisture, at which drying stage they are glued into the instrument. Fluctuations of the moisture content in the wood affect the tone. With changing moisture content, the instrument can go out of tune, even cracks can appear at very low moisture content in the wood. In addition, the tone colour will change. This may result from changes in the hammer felt or from changes in the vibration properties of the soundboard. Strain- and frequency-dependent damping measurements were carried out on spruce wood at different wood moisture contents in order to investigate the effect of the moisture content on the vibration behaviour. Wood which is slowly dried in air for several years is preferably used for high-class pianos. Therefore, damping measurements on new and on more than 130-year old spruce wood samples were performed.
Źródło:
Acta Physica Polonica A; 2018, 133, 5; 1241-1260
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Validation of UV Spectrophotometric and HPLC Methods for Quantitative determination of chlorpyrifos
Autorzy:
Zalat, O. A.
Elsayed, M. A.
Fayed, M. S.
Abd El Megid, M. K.
Powiązania:
https://bibliotekanauki.pl/articles/412092.pdf
Data publikacji:
2014
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
chlorpyrifos
HPLC
UV-spectrophotometric
liner range
Opis:
A specific and sensitive HPLC and UV spectrophotometric methodwere developed for determination and analysis of chlorpyrifos. Chromatographic separation was achieved on a 150 mm x 10 mm I.D. reversed phase column Zorbax SB C-18. usingdeionizedwater: acetonitrile in the ratio of 10:90 v/v respectively as mobile phase. The effluent was monitored at 290 and 230 nm. Two sharp peaks were obtained for the solvent and chlorpyrifos at 2.7 and 3.45 min respectively. UV spectrophotometric method was performed at 290 nm using Isopropanol as the solvent. Linear range was 0.025-3500 ppm (r2 = 0.9986 ±0.0009) for HPLC method and 2.229 to 200 ppm (r2 = 0.9988) for UV spectrophotometric method. Validation guidelines and statistical analysis showed that both the methods were precise, accurate, sensitive, and can be used for the routine quality control of chlorpyrifos in waste discharges.
Źródło:
International Letters of Chemistry, Physics and Astronomy; 2014, 2; 58-63
2299-3843
Pojawia się w:
International Letters of Chemistry, Physics and Astronomy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Sources of uncertainty for the Determination of Chlorpyrifos by Gas Chromatography Equipped with Flame Photometric Detector
Autorzy:
Zalat, O. A.
Elsayed, M. A.
Fayed, M. S.
Abd El Megid, M. K.
Powiązania:
https://bibliotekanauki.pl/articles/411973.pdf
Data publikacji:
2014
Wydawca:
Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
Tematy:
sensitivity
Minimum detectability
Chlorpyrifos
injection
Opis:
Analysts are increasingly being required to evaluate the uncertainty associated with methods. Estimating the uncertainty of an analytical result is an essential part of quantitative analysis. This paper discusses the sources of uncertainty of chlorpyrifos determination by gas chromatography equipped with flame photometric detector (GC-FPD). The analysis was performed on HP-5 MS, 30 m x 0.32 mm capillary column with a 0.25 μm stationary film thickness using ultra pure nitrogen (99.9999 %) as a carrier gas at 25 psi constant pressure. The method has been optimized. Factors affecting quantization of chlorpyrifos such as injector temperature, carrier gas inlet pressure, air to hydrogen ratios and initial temperature program have been studied to get the best sensitivity, minimum delectability. The liner range of the detector was from 0.15 ng/ml to 1200 ppm, the minimum detection limit was 0.15 ng/ml and the relative standard deviation was 0.839.
Źródło:
International Letters of Chemistry, Physics and Astronomy; 2014, 6; 8-55
2299-3843
Pojawia się w:
International Letters of Chemistry, Physics and Astronomy
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies