Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Fang, Yan" wg kryterium: Autor


Wyświetlanie 1-7 z 7
Tytuł:
Research on regional emergency DC power support strategy of VSC-MTDC transmission system
Autorzy:
Li, Congshan
Sheng, Tingyu
Fang, Yan
Li, Yikai
Powiązania:
https://bibliotekanauki.pl/articles/1841327.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
coordinated control
dynamic active power support
emergency DC power support
VSC-MTDC
skoordynowana kontrola
dynamiczne wspomaganie mocy czynnej
awaryjne wsparcie zasilania prądem stałym
Opis:
In the asynchronous interconnected power grid that is composed of the multiterminal voltage-source converter high voltage direct current (VSC-MTDC) system, the control methods of each converter station and the frequency of the connected AC systemare not the same. When a fault occurs in any place of the asynchronous interconnected system, it will cause the system to have power shortage or surplus, affecting the safe and stable operation of the interconnected power grid. In order to solve the problem of insufficient regional active power reserve, based on the VSC-MTDC asynchronous regional interconnection system and the principle of regional sharing, the dynamic power controller under disturbance conditions is established, and the controller parameters are set to achieve the accuracy of unbalanced power in the disturbance area measuring. Then, according to the degree of the disturbance power, considering the factors that affect the support effect of the converter station, an emergency DC power support (EDCPS) scheme under different power disturbances is formulated to achieve power compensation for the disturbance area. Basedon PSCAD/EMTDC software, the proposed control strategy is simulated. The result showst hat the converter station closer to the disturbance area has a better support effect, and the dynamic active power controller can timely and accurately deliver to the disturbance area when the active power reserve is insufficient.
Źródło:
Archives of Electrical Engineering; 2021, 70, 1; 145-160
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An approach to suppress low-frequency oscillation in the hybrid multi-Infeed HVDC of mixed H2/H∞ robust-based control theory
Autorzy:
Li, Congshan
Liu, Yan
Li, Yikai
He, Ping
Fang, Yan
Sheng, Tingyu
Powiązania:
https://bibliotekanauki.pl/articles/2042784.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
additional damping controller
CSP
HMIDC
LFO
mixed 2/∞ control
TLS-ESPRIT
Opis:
A hybrid multi-infeed HVDC (HMIDC) system is composed of line-commutated converter-based high-voltage direct current (LCC-HVDC) and voltage-source converterbased high-voltage direct current (VSC-HVDC), whose receiving ends have electrical coupling. To solve the problem of low-frequency oscillation (LFO) caused by insufficient damping in the HMIDC system, according to the multi-objective mixed 2/∞ output feedback control theory with regional pole assignment, an additional robust damping controller is designed in this paper, which not only has good robustness, but also has strong adaptability to the change of system operation mode. In the paper, the related oscillation modes and transfer function of the controlled plant are obtained, which are identified by the total least squares estimation of signal parameters via rotary invariance technology (TLS-ESPRIT). In addition, the control-sensitive point (CSP) for suppressing LFO based on the small disturbance test method is determined, which is suitable for determining the installation position of the controller. The results show that the control sensitivity factor of VSC-HVDC is greater than that of LCC-HVDC so that adding an additional damping controller to VSC-HVDC is better than LCC-HVDC in suppressing the LFO of HMIDC. Finally, a hybrid double infeed DC transmission system with three receiving terminals is built on PSCAD/EMTDC where the time-domain simulations are performed to verify the correctness of the CSP selection and the effectiveness of the controller.
Źródło:
Archives of Electrical Engineering; 2022, 71, 1; 109-124
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of vertical ground motion on seismic responses of triple friction pendulum interlayer isolation structures
Autorzy:
Fang, Zhao
Yan, Ping
Powiązania:
https://bibliotekanauki.pl/articles/1852324.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ruch gruntu pionowy
struktura
izolacja międzywarstwowa
odpowiedź sejsmiczna
wahadło z potrójnym tarciem
vertical ground motion
interlayer isolation
structure
seismic response
triple friction pendulum
Opis:
In order to investigate the influence of vertical ground motion on seismic responses of story-isolation structures mounted on triple friction pendulum (TFP) bearings, the finite element model of a six-story building with various types of interlayer isolation TFP bearings under far field or near fault ground motions is established and analysed. A discrepancy rate function of peak interlayer shear, acceleration and displacement results is adopted to discuss the influence of the vertical seismic motions on isolation structural responses. Furthermore, the isolation form, the isolation period and the friction coefficient of bearings are changed to study their effect on the vertical seismic component’s influence. The results show that the influence of the vertical seismic component is considerable on the isolation layer especially under near-fault ground motions, so it should not be overlooked during the structural design; The change of isolation forms will greatly affect the influence of the vertical seismic component especially in the isolation layer and isolation systems with isolation devices set on higher stories or with less isolation layers will have less vertical seismic effect on story acceleration; The increase of the isolation period will globally result in the decrease of the influence of vertical seismic components, though in some cases it shows some sort of fluctuation before the final decrease; The increase of the friction coefficient will lead to the global decrease in the influence of the vertical seismic component in single-layer isolation structures, while it does not obviously affect those in the multi-layer isolation systems.
Źródło:
Archives of Civil Engineering; 2021, 67, 3; 581-597
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research on sand resistance performance of comprehensive protection facilities for desert hinterland highways under strong wind environment
Autorzy:
Yan, Wenhua
Wang, Xu
Wu, Yongxiang
Wang, Fang
Powiązania:
https://bibliotekanauki.pl/articles/2174072.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Opis:
Based on the test and observation of the desert hinterland wind field, combined with the numerical simulation of Fluent wind-sand two-phase flow, the sand resistance performances of comprehensive protection in the desert hinterland under strong wind environment are researched. The transient wind speed and wind direction around the comprehensive protection facility are measured by two 3D ultrasonic anemometers on the highway in the desert hinterland, and the initial wind speed of the sand flow is provided for the numerical simulation boundary. The sedimentary sand particles around the comprehensive protection facility are collected for particle size analysis, and the particle size distributions of sedimentary sand particles at different locations are obtained. Numerical models of high vertical sand barriers, grass checkered sand barriers and roadbeds are established by Fluent, the wind-sand flow structures around the comprehensive protection facilities and desert hinterland highway under the strong wind environment are obtained, and the influence laws of the comprehensive protection facilities on the movement of wind-sand flow and sand deposition characteristics are obtained. The study found that the comprehensive protection facilities disturbed the wind and sand flow, and there are significant airflow partitions around the comprehensive protection facilities. The wind speed decreases rapidly after the wind-sand flows through the high vertical sand barrier; the wind-sand flow rises at the end of the high vertical sand barrier. When the wind-sand flow moves around the grass checkered sand barrier, the wind speed has dropped to the range of 0-3 m/s, and the wind speed near the ground by the grass checkered sand barrier is further reduced. Due to the existence of the concave surface of the grass grid, there are small vortices inside the grass grid sand barrier. Large sand particles are mainly deposited on the windward side and inside of high vertical sand barriers. The grass checkered sand barrier forms a stable concave surface to generate backflow, which can ensure that the sand surface does not sand itself in a strong wind environment, and can also make a small amount of sand carried in the airflow accumulate around the groove of the grass checkered sand barrier. The numerical simulation results are consistent with the measured results, and the comprehensive protection measures have achieved good sand control effects.
Źródło:
Archives of Civil Engineering; 2022, 68, 4; 683--698
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reliability assessment of the port power system based on integrated energy hybrid system
Autorzy:
Fang, Liang
Xu, Xiao-Yan
Xia, Jun
Tarasiuk, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2173637.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
Markov model
distributed generation
reliability assessment
integrated energy
distribution power system
model Markowa
generacja rozproszona
ocena wiarygodności
energia zintegrowana
system zasilania dystrybucyjny
Opis:
The conventional port distribution power system is being disrupted by increasing distributed generation (DG) levels based on integrated energy. Different new energy resources combine with conventional generation and energy storage to improve the reliability of the systems. Reliability assessment is one of the key indicators to measure the impact of the distributed generation units based on integrated energy. In this work, an analytical method to investigate the impacts of using solar, wind, energy storage system (ESS), combined cooling, heating and power (CCHP) system and commercial power on the reliability of the port distribution power system is improved, where the stochastic characteristics models of the major components of the new energy DG resources are based on Markov chain for assessment. The improved method is implemented on the IEEE 34 Node Test Feeder distribution power system to establish that new energy resources can be utilized to improve the reliability of the power system. The results obtained from the case studies have demonstrated efficient and robust performance. Moreover, the impacts of integrating DG units into the conventional port power system at proper locations and with appropriate capacities are analyzed in detail.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2022, 70, 2; art. no. e140372
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of heating rate and solvent on Ni-based catalysts prepared by solution combustion method for syngas methanation
Autorzy:
Zeng, Yan
Ma, Hongfang
Zhang, Haitao
Ying, Weiyong
Fang, Dingye
Powiązania:
https://bibliotekanauki.pl/articles/779390.pdf
Data publikacji:
2014
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
nickel catalysts
syngas methanation
solution combustion method
Opis:
Ni-Al2O3 catalysts prepared by solution combustion method for syngas methanation were enhanced by employing various heating rate and different solvent. The catalytic properties were tested in syngas methanation. The result indicates that both of heating rate and solvent remarkably affect Ni particle size, which is a key factor to the catalytic activity of Ni-Al2O3 catalysts for syngas methanation. Moreover, the relationship between Ni particle size and the production rate of methane per unit mass was correlated. The optimal Ni-Al2O3 catalyst prepared in ethanol at 2°C/min, achieves a maximum production rate of methane at the mean size of 20.8 nm.
Źródło:
Polish Journal of Chemical Technology; 2014, 16, 4; 95-100
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effectiveness of fly ash on the stabilization/solidification of Zn-contaminated soil
Autorzy:
Chen, Yan
Zhu, Shengyuan
Fang, Wei
Huang, He
Qin, Hao
Hu, Shengtao
Wu, Yuzhao
Powiązania:
https://bibliotekanauki.pl/articles/27323977.pdf
Data publikacji:
2023
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
fly ash
soil
heavy metals
X-ray diffraction
Zn2+
popiół lotny
gleba
metale ciężkie
dyfrakcja rentgenowska
Opis:
As a solid waste, the associated disposal cost of fly ash is really high. Previous studies suggested that the utilization of fly ash to treat heavy metal-contaminated soils was a new cost-effective method of disposal of it. Therefore, the effectiveness of fly ash stabilized/solidified Zn-contaminated soils has been investigated by unconfined compressive strength (UCS) and toxicity characteristics leaching procedure (TCLP) tests. Quantitative analysis of the soil microstructure was conducted by processing the X-ray diffraction (XRD) and scanning electron microscope (SEM) images. Mercury intrusion porosimetry (MIP) was carried out to illustrate the size and proportion of pore size for specimens under different ratios. The results of the tests showed an improvement in the UCS, which further increased as the content of binders was raised. Binder content would have little influence on the development of strength if the binder content exceeds a threshold value. The leached Zn2+ concentration of stabilized specimens was significantly decreased compared to that of untreated. Quantitative analysis confirmed that the addition of the binders resulted in the amount of hydration product, reduction of porosity, and a really random pores orientation, which was responsible for the improvement of the strength and leaching properties of the Zn2+ contaminated soils.
Źródło:
Environment Protection Engineering; 2023, 49, 3; 15--29
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies