Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Drzymała, M." wg kryterium: Autor


Tytuł:
Analysis of the impact of high temperature on the change in tensile strength of cement mortars with or without polypropylene fibres added
Autorzy:
Drzymala, T.
Reszka, M.
Powiązania:
https://bibliotekanauki.pl/articles/30147052.pdf
Data publikacji:
2018
Wydawca:
Akademia Wojsk Lądowych imienia generała Tadeusza Kościuszki
Tematy:
cement composites
cement mortars
tensile strength
mechanical properties
high temperature impact
thermal spalling
concrete
reinforced concrete
polypropylene fibre
Opis:
When evaluating concrete, its strength is the most important feature from the practical point of view. In compliance with technological requirements, the strength of concrete depends primarily on its composition, mainly on the content and strength of cement slurry. This is because this concrete component is most susceptible to changes in working conditions in a construction, including high temperature impact on concrete during the fire. The paper presents the results of tests performed on the cement mortar with and without the addition of polypropylene fibers. This treatment allowed for the elimination of the effect of the coarse aggregate by reason of the accuracy of the tested strength characteristics. The studies concerned the impact of high temperature on the change in tensile strength of cement mortars modified with the addition of polypropylene fibers. The analysis of available literature shows that one of the main causes of concrete’s thermal spalling is seen in high tensile stresses. The results of many tests prove that the addition of polypropylene fibers can have a positive effect on the behavior of concrete structures at high temperatures and help reduce spalling. The polypropylene fibers present in a composite may also positively influence the increase in tensile strength. This article discusses the purpose and scope of research, research methods, the experiment plan, test benches, and test results as well. The conclusions of the study were formulated in the final part of the article.
Źródło:
Scientific Journal of the Military University of Land Forces; 2018, 50, 3(189); 109-126
2544-7122
2545-0719
Pojawia się w:
Scientific Journal of the Military University of Land Forces
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu wydatku i ustawienia głowicy prądownicy TurboJjet 52 na rozkład intensywności zraszania w strumieniu rozpylonym
Analysis of the Impact of the Flow Rate and Settings of the Nozzle TurboJet 52 on Distribution of the Sprinkling Intensity in Spray
Autorzy:
Drzymała, T.
Gałaj, J.
Wójcik, M.
Powiązania:
https://bibliotekanauki.pl/articles/137028.pdf
Data publikacji:
2017
Wydawca:
Szkoła Główna Służby Pożarniczej
Tematy:
rozpylanie
prądownica wodna
strumień wody
natężenie przepływu
średnica kropli
intensywność zraszania
powierzchnia zraszania
spraying
water nozzle
water stream
flow rate
water droplet diameter
sprinkling intensity
sprinkling area
Opis:
W artykule zaprezentowano badania doświadczalne dotyczące wpływu wydatku i ustawienia głowicy prądownicy TurboJet 52 na rozkład intensywności zraszania w strumieniu rozpylonym. Omówiono w nim m.in. przedmiot i metodykę badań i stanowisko pomiarowe oraz przebieg badań. Prądownicę TurboJet 52 badano przy trzech różnych ustawieniach głowicy, odpowiadających kątom rozpylenia strumienia: 60º, 90º i 120º. Podczas badań rejestrowano wyniki dla trzech różnych wydatków: 230 dm3/min, 330 dm3/min i 450 dm3/min. Badania prądownicy odbywały się dla wszystkich ustawień przy stabilizowanym ciśnieniu zasilania równym około 6 bar. Wyniki rozkładów intensywności zraszania w strumieniu rozpylonym przedstawiono w formie graficznej. Przeprowadzono analizę wyników oraz sformułowano wnioski, mające wymiar praktyczny dla strażaków operujących rozproszonymi prądami wodnymi.
This paper presents studies on the influence of the nozzle output and spray angle on the distribution of sprinkling intensity in a spray generated by the TurboJet 52 nozzle. Among the others the following issues have been discussed in the paper: study subject, study method, research stand and the course of studies. The studies were conducted for three different nozzle spray angles of 60°, 90° and 120° and three different flow rates of 230 dm3/min, 330 dm3/min and 450 dm3/min. The studies for all settings were carried out at the stabilized supply pressure equal to about 6 bars. The results of sprinkling intensity distribution are presented on the graphs. Based on the analysis of the results the conclusions have been set. They are , important not only for the theoretical considerations but can be applied in practice, especially for fire-fighters operating with water stream.
Źródło:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej; 2017, 1, 61; 151-169
0239-5223
Pojawia się w:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Water contact angle on corresponding surfaces of freshly fractured fluorite, calcite and mica
Autorzy:
Kowalczuk, P. B.
Akkaya, C.
Ergun, M.
Janicki, M.
Sahbaz, O.
Drzymala, J.
Powiązania:
https://bibliotekanauki.pl/articles/110595.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
contact angle
surface properties
cleaving plane
surface composition
corresponding halves
fluorite
calcite
mica
Opis:
Advancing and receding contact angles of water with corresponding surfaces of freshly fractured calcite, fluorite and mica were measured. The corresponding surfaces were obtained by mechanical splitting of a small lump of each mineral into two pieces. Theoretical considerations revealed that depending on the mineral cleaving plane, surfaces created by splitting into halves can be either identical or entirely different as far as their surface chemical composition is concerned. It was experimentally established that receding and advancing contact angles measured on the corresponding surfaces of fluorite, calcite and mica were identical for the sessile drop method. When the contact angle was measured by the captive bubble approach, there were small differences in the contact angles measured on the corresponding surfaces of fluorite. It was most probably due to surface irregularities and roughness, and therefore different times needed to rupture the liquid film between the bubble and solid surface.
Źródło:
Physicochemical Problems of Mineral Processing; 2017, 53, 1; 192-201
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wymagań dla instalacji wodociągowych przeciwpożarowych w wysokich budynkach mieszkalnych
An Analysis of Water Supply System Requirements to Enhance Fire Safety in High Rise Residential Accommodation
Autorzy:
Drzymała, T.
Kieliszek, S.
Szutkowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/372894.pdf
Data publikacji:
2016
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
wymagania dla instalacji wodociągowych
budynki mieszkalne
gaszenie pożarów
systemy gaśnicze
ochrona przeciwpożarowa
requirements for water supplies
residential buildings
firefighting
firefighting systems
fire protection
Opis:
Cel: Celem artykułu jest przedstawienie wymagań dla instalacji wodociągowych przeciwpożarowych, ze szczególnym uwzględnieniem wysokich budynków mieszkalnych oraz wyposażenia tego typu budynków w instalacje przeciwpożarowe, zgodnie z regulacjami zawartymi w aktach prawnych i normach. Wymagania porównano z rzeczywistym zużyciem wody do gaszenia pożarów w tych budynkach na przykładzie m. st. Warszawy. Wskazano problemy związane ze spełnieniem wymagań zawartych w aktach prawnych i normach. Metody: Artykuł opracowano w oparciu o porównanie wymagań dla instalacji wodociągowych przeciwpożarowych w wysokich budynkach mieszkalnych zawartych w przepisach i polskich normach. Porównania dokonano na tle zmian przepisów w ujęciu historycznym. Analizę rzeczywistego zużycia wody do gaszenia pożarów w budynkach mieszkalnych dla m. st. Warszawy przeprowadzono w oparciu o dane statystyczne zawarte w programie „Ewid”, który stanowi wyposażenie każdej jednostki ratowniczo-gaśniczej w Polsce. Wyniki: Na podstawie danych statystycznych można stwierdzić, że wysokość budynku w sposób znaczący wpływa na ilość wody potrzebnej do ugaszenia pożaru. Z danych statystycznych wynika, że na przestrzeni analizowanych lat w budynkach wysokościowych nie odnotowano pożarów dużych i średnich, a w budynkach wysokich wystąpił tylko jeden taki pożar, do którego ugaszenia wystarczyło 0,5 m3 wody. Średnie i duże pożary w zdecydowanej większości występują w budynkach niskich, tzn. o wysokości do 12 m, rzadziej w średniowysokich tzn. o wysokości do 25 m. Ponadto można zauważyć ciekawą zależność, że wraz ze wzrostem wysokości budynku, średnia ilość wody potrzebna do ugaszenia pożaru maleje. Z powyższego wynika, że wskazana jest szczegółowa analiza wysokich wymagań odnośnie wydajności instalacji w wysokich budynkach mieszkalnych. Wnioski: Z analizy danych statystycznych wynika, że wraz ze wzrostem wysokości budynku maleje ilość wody potrzebna do ugaszenia pożaru. Główną przyczyną takiej zależności jest wzrost klasy odporności pożarowej budynku wraz ze wzrostem jego wysokości. Skutkuje to wyeliminowaniem materiałów palnych i zwiększeniem wymagań w zakresie klasy odporności pożarowej. Reasumując, obecnie obowiązujące wymagania zawarte w przepisach dotyczących przeciwpożarowego zaopatrzenia w wodę zapewniają możliwość prowadzenia w budynkach mieszkalnych skutecznych działań ratowniczych. Są one jednak nie do końca dopracowane i należałoby je dostosować do panujących realiów. Wskazana jest nowelizacja rozporządzenia w sprawie ochrony przeciwpożarowej budynków, innych obiektów budowlanych i terenów, w części dotyczącej instalacji wodociągowych w wysokich budynkach mieszkalnych.
Aim: The objective of this paper is to present the requirements of firefighting water supply systems with special focus on high residential buildings and firefighting equipment in such buildings, according to regulations in legal acts and standards. The requirements were compared with real water consumption for firefighting purposes in the buildings based on a Warsaw City case study. The problems associated with fulfilling the requirements contained in legal acts and standards have been indicated. Methods: The paper was developed based on the comparison of requirements for firefighting water supply systems in high residential buildings contained in legal acts and Polish standards. The comparison was made with regards to changes in regulations from the historical perspective. An analysis of actual water consumption for firefighting purposes in residential buildings for Warsaw City was made based on statistical data available from “Ewid” software, a standard resource for every rescue/firefighting brigade in Poland. Results: Based on the statistical data it can be concluded that the height of buildings significantly influences the amount of water consumed for firefighting purposes. It results from the statistical data that no large or medium-sized fires in high buildings were recorded in the analysed years, while in high buildings only one such fire occurred that required only approx. 0.5 m3 of water. Medium-sized and large fires in most cases occurred in small buildings, i.e. at a height below 12 m, more rarely in medium-high buildings i.e. at a height of up to 25 m. Furthermore, an interesting relationship was noted - the higher the building the less amount of water was required to distinguish the fire. It follows from this that a detailed analysis of the strict requirements for the water capacity of installations in high residential buildings is recommended. Conclusions: The analysis of the statistical data showed that with increasing building height of the amount of water required for fire extinguishing decreased. A major reason for such a correlation was the increase in fire resistance class of buildings with increasing height. It reflects the exclusion of flammable materials and an increase in requirements in terms of fire resistance class. Summarising, the current requirements contained in the regulations for firefighting water supply provide the possibility of carrying out effective activities in residential buildings. However, they are not refined, and they should be adjusted to the reality. It is recommended that the regulation on the fire protection of buildings, and other buildings objects and sites be amended in the part related to water supplies in high residential buildings.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2016, 43, 3; 275-284
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Durability of high performance concrete (HPC) subject to fire temperature impact
Autorzy:
Jackiewicz-Rek, W.
Drzymała, T.
Kuś, A.
Tomaszewski, M.
Powiązania:
https://bibliotekanauki.pl/articles/231408.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
trwałość
beton wysokowartościowy
warunki pożarowe
fibrobeton
beton napowietrzony
durability
high performance concrete
fire conditions
fibre reinforced concrete
aerated concrete
Opis:
In the recent years a tendency for design of increasingly slender structures with the use of high performance concrete has been observed. Moreover, the use of high performance concrete in tunnel structures, subject to high loads with possibility of extreme loads occurrence such as fire, has an increasing significance. Presented studies aimed at improving high performance concrete properties in high temperature conditions (close to fire conditions) by aeration process, and determining high temperature impact on the concretes features related to their durability. In this paper it has been proven that it is possible to obtain high performance concretes resistant to high temperatures, and additionally that modification of the concrete mix with aerating additive does not result in deterioration of concrete properties when subject to water impact in various form.
Źródło:
Archives of Civil Engineering; 2016, 62, 4/II; 73-93
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Network Steganography in the DNS Protocol
Autorzy:
Drzymała, M.
Szczypiorski, K.
Urbański, M. Ł.
Powiązania:
https://bibliotekanauki.pl/articles/227099.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
DNS
network steganography
malware
Opis:
This paper presents possibility of using of the DNS (Domain Name System) protocol for creating a simplex communication channel between a malware-infected computer with a compromised DNS server. The proposed channel can be used to steal data or confidential enterprise information secretly.
Źródło:
International Journal of Electronics and Telecommunications; 2016, 62, 4; 343-346
2300-1933
Pojawia się w:
International Journal of Electronics and Telecommunications
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Structure and surface energy of both fluorite halves after cleaving along selected crystallographic planes
Autorzy:
Janicki, M. J.
Drzymala, J.
Kowalczuk, P. B.
Powiązania:
https://bibliotekanauki.pl/articles/110167.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
fluorite
fluoride
surface energy
interfacial energy
cleaving
reorganization
surface ions
Opis:
The density functional theory, supported with a commercial software, was used to compute the geometry and surface energy of fluorite cleaved along the (111), (110) and (100) planes. In the case of cleaving a piece of fluorite along the (111) plane the two newly created surfaces are identical consisting of fluorite ions with the surface energy equal to 0.384 J/m2. Cleaving fluorite along the (110) plane also provides identical halves and, both contain one Ca ion next to two F ions, with the surface energy equal to 0.723 J/m2. When cleaving takes place along the (100) plane, it creates two corresponding halves with different surface structures. One half, having only surface Ca ions (100Ca) has the surface energy equal to 0.866 J/m2, while the surface energy of the second half, having only F surface ions (100F), is 0.458 J/m2. Different structures and energies of the corresponding fluorite surfaces, that is (100Ca) and (100F) planes, should have an impact on their chemical properties, including hydrophobicity expressed by contact angle. The calculations performed in the paper also showed that reorganization of fluorite surfaces after cleaving was insignificant for all of the investigated planes.
Źródło:
Physicochemical Problems of Mineral Processing; 2016, 52, 1; 451-458
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evolution of Microstructure in Rolled Mg-Based Alloy. Textural Aspect
Ewolucja mikrostruktury w walcowanym stopie na bazie Mg. Aspekt teksturowy
Autorzy:
Drzymała, P.
Kania, B.
Wróbel, M.
Darłak, P.
Długosz, P.
Kwaśniewski, P.
Bonarski, J. T.
Powiązania:
https://bibliotekanauki.pl/articles/354309.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
magnesium alloy
plastic deformation
pilger rolling
mechanical twinning
crystallographic texture
stop magnezu
odkształcenia plastyczne
stop walcowany
tekstura krystalograficzna
Opis:
Magnesium alloys are the lightest structural materials, which makes them particularly suitable for use in the aircraft and automotive industry. However, due to hexagonal close-packed crystal structure, resulting in insufficient number of independent slip systems, magnesium alloys exhibit poor formability at room temperature. Conventional methods of work hardening of magnesium alloys requires the temperature about 300°C, which favours simultaneously processes of thermal recovery and grain growth, but decreases beneficial microstructure strengthening effect. Thus, it is a crucial to undertake development of a technology for semi-finished magnesium alloys elements, which will ensure better mechanical properties of the final products by forming desirable microstructure. In the paper we present the development of crystallographic texture of the Mg-based alloy (Mg-AZ31) in the form of pipe extruded at 430°C and subjected to pilger rolling at relatively low temperature.
Stopy magnezu należą do najlżejszych materiałów konstrukcyjnych, co czyni je szczególnie użytecznymi w przemyśle lotniczym i samochodowym. Jednakże ze względu na strukturę heksagonalną zwartą, skutkującą niewystarczającą liczbą systemów poślizgu, stopy magnezu wykazują złą plastyczność w temperaturze pokojowej. Konwencjonalne metody umocnienia poprzez zgniot wymagają temperatury około 300°C dla tych stopów, co sprzyja jednocześnie procesom zdrowienia i rozrostu ziarna, ale obniża sam efekt umocnienia. Zatem kluczowe jest rozwinięcie technologii dla półproduktów ze stopu magnezu, która zapewni lepsze właściwości mechaniczne końcowych produktów poprzez uformowanie korzystnej mikrostruktury. W pracy przedstawiono rozwój tekstury krystalograficznej stopu na bazie magnezu (Mg-AZ31) w formie rury wyciśniętej w temperaturze 430°C i poddanej walcowaniu pielgrzymowemu we względnie niskiej temperaturze.
Źródło:
Archives of Metallurgy and Materials; 2015, 60, 4; 2505-2512
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ dodatku hydroksytlenku glinu na krytyczny czas redukcji widzialności w dymie powstałym ze spalania oraz pirolizy żywicy epoksydowej
Influence of aluminum hydroxide oxide addition on the critical time of visibility reduction in smoke from pyrolysis and combustion of epoxy resin
Autorzy:
Węsierski, T.
Łukaszek-Chmielewska, A.
Konecki, M.
Drzymała, T.
Powiązania:
https://bibliotekanauki.pl/articles/947448.pdf
Data publikacji:
2015
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Chemii Przemysłowej
Tematy:
spalanie żywicy epoksydowej
krytyczny czas redukcji widzialności
ewakuacja
uniepalniacz
zasięg widzialności
epoxy resin combustion
critical time of visibility reduction
evacuation
flame retardant
visibility range
Opis:
Zbadano wpływ dodatku 5 % mas. hydroksytlenku glinu [AlO(OH)] na wydłużenie krytycznego czasu redukcji widzialności w strefie dymu wydzielanego podczas spalania lub pirolizy żywicy epoksydowej (Epidian 5).
The effect of the addition of 5 wt % aluminum hydroxide oxide [AlO(OH)] to epoxy resin Epidian 5 on the improvement in evacuation conditions from a smoke-filled area during the burning or pyrolysis of the resin has been investigated. An increase in the critical time of visibility reduction was observed.
Źródło:
Polimery; 2015, 60, 11-12; 723-729
0032-2725
Pojawia się w:
Polimery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Light alloys for application as engine parts – comparison of properties of three materials
Autorzy:
Ranachowski, Z.
Pawełek, A.
Drzymała, P.
Bonarski, J.
Lewandowski, M.
Ozgowicz, W.
Powiązania:
https://bibliotekanauki.pl/articles/360032.pdf
Data publikacji:
2014
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
hcp metals
aluminium and magnesium alloys
plastic deformation
mechanical twinning
crystallographic texture
acoustic emission
Opis:
This paper discusses the mechanical properties, microstructure and crystallographic texture of light alloys made on the base of aluminium, magnesium and lithium. An acoustic emission (AE) technique was applied to detect the moment of twinning or slip activation during compression and channel – die tests to extend the comprehension on the nature of the plastic deformation processes occurring in the investigated alloys.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2014, 39 (111); 128-132
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zeta potential of Polish copper-bearing shale in the absence and presence of flotation frothers
Autorzy:
Peng, M.
Ratajczak, T.
Drzymała, J.
Powiązania:
https://bibliotekanauki.pl/articles/89095.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Wydział Geoinżynierii, Górnictwa i Geologii. Instytut Górnictwa
Tematy:
zeta potential
frother
flotation
shale
pH
isoelectric point
IEP
empirical equation
Opis:
In this paper, zeta potential as a function of pH of copper-bearing shale, which is mined in Poland by KGHM, was investigated. The measurements were conducted in water and aqueous solutions of selected flotation frothers. It was established that for investigated copper-bearing shale, after dispersion in water, the isoelectric point (IEP) occurs at pH=3.5. Addition of frothers decreased the IEP on the pH scale and the IEP for butanol was 1.93, for MIBC 2.90 and for eicosaethylene glycol hexadecyl ether (C16E20) 2.76. In the case of introducing frothers changed, the zeta potential becomes less negative. An empirical equation, having two adjustable parameters, was used in the paper to approximate the course of the zeta potential-pH curve. The equation showed a very good approximation of the zeta potential of the investigated shale either in water or frother aqueous solutions.
Źródło:
Mining Science; 2014, 21; 57-63
2300-9586
2353-5423
Pojawia się w:
Mining Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Flotation after a direct contact of flotation reagents with carbonate particles. Part 1, Model investigations
Autorzy:
Ahmed, H. A. M.
Aljuhani, M. S.
Drzymala, J.
Powiązania:
https://bibliotekanauki.pl/articles/109753.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
phosphates
flotation
microemulsion
separation Introduction
Opis:
Carbonate fluorapatite (francolite), calcite and dolomite separately, as well as their model mixtures, were subjected to flotation after conditioning the particles with microemulsion consisting of 20% of Custafloat AR27 (collector, blend of fatty acid soaps and sulfates), 55% fuel oil #5 and 25% water at 70% solids density and subsequent pulp dilution with water to 25% solids. The best separation of carbonate fluorapatite from calcite and dolomite occurred at pH 8.5 and microemulsion dose between 0.9 and 1.5 kg/Mg, 1.5 min conditioning time and 2 minutes of flotation time. The obtained flotation concentrates using 1.5 kg/Mg of collector contained 84% carbonate fluorapatite (34% P2O5) with 84% recovery. The 84/84 separation efficiency in terms of grade-recovery indices points to promising results which can be obtained for real phosphate ores.
Źródło:
Physicochemical Problems of Mineral Processing; 2013, 49, 2; 713-723
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena stanu chemicznego wód podziemnych w zlewni Sękówki
Estimation of groundwater chemical status in Sękówka river catchment area
Autorzy:
Kmiecik, E.
Zdechlik, R.
Drzymała, M.
Powiązania:
https://bibliotekanauki.pl/articles/2062236.pdf
Data publikacji:
2013
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
stan chemiczny
wody podziemne
zlewnia Sękówki
chemical status
groundwater
Sękówka River catchment area
Opis:
Ramowa Dyrektywa Wodna (DRW, 2000) wymaga ustanowienia dwóch programów monitoringu wód podziemnych: stanu ilościowego i stanu chemicznego. Sieć monitoringu dla oceny stanu chemicznego wód podziemnych powinna pozwolić na przeprowadzenie oceny w każdym dorzeczu oraz wykrycie długoterminowych trendów zmian jakości wód. W niniejszym artykule zaprezentowano ocenę stanu chemicznego wód podziemnych, przeprowadzoną zgodnie ze wskazaniami RDW, dla wytypowanego obszaru – południowej części zlewni potoku Sękówka, na podstawie wyników własnych terenowych i laboratoryjnych badań monitoringowych. Wyniki badań laboratoryjnych poddano weryfikacji na podstawie błędu analizy wyliczonego według bilansu jonowego. Określono typy hydrogeochemiczne wód zgodnie z klasyfikacją Szczukariewa-Prikłońskiego. Ocenę stanu chemicznego wód podziemnych przeprowadzono w układzie punktowym i obszarowym zgodnie z wytycznymi przepisów polskich (RMŚ, 2008) i UE (RDW, 2000).
Water Framework Directive (RDW, 2000) requires establishing two programmes, which should cover monitoring of the chemical and quantitative status of groundwaters. The monitoring network for the chemical status assessment of groundwaters shall be designed so as to provide a comprehensive overview of chemical status within each river basin and shall permit identification of long-term trends of variations in groundwater quality. In this paper the chemical status assessment of groundwater of the south part of Sękówka River catchment area was presented, conducted in accordance with above requirements and using own field and laboratory research results. Laboratory results were verified on the base of analyses errors calculated as per the ionic balance. The hydrogeochemical types were specified in accordance with the Szczukariew-Prikłoński classification. The chemical status assessment of groundwater was conducted in point and area configuration, according to Polish (RMŚ, 2008) and UE (RDW, 2000) regulations.
Źródło:
Biuletyn Państwowego Instytutu Geologicznego; 2013, 456 Hydrogeologia z. 14/1; 287--291
0867-6143
Pojawia się w:
Biuletyn Państwowego Instytutu Geologicznego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Praktyczne aspekty opróbowania wód w systemie monitoringu wód podziemnych
Practical aspects of water sampling in groundwater monitoring
Autorzy:
Zdechlik, R.
Drzymała, M.
Wątor, K.
Powiązania:
https://bibliotekanauki.pl/articles/2062432.pdf
Data publikacji:
2013
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
monitoring wód podziemnych
wody podziemne
metodyka opróbowania
groundwater monitoring
groundwater
sampling methodology
Opis:
Istotnym elementem monitoringu jakości wód podziemnych jest proces opróbowania wód, obejmujący nie tylko sam etap poboru próbek, ale także czynności związane z ich utrwalaniem, przechowywaniem oraz transportem do laboratorium, jak również terenowymi pomiarami wskaźników nietrwałych. Z uwagi na różnorodność możliwych sytuacji, rzeczywiste badania terenowe mogą odbiegać od przedstawianych w literaturze schematów. Wykorzystując własne wieloletnie doświadczenie, autorzy prezentują praktyczne aspekty poboru próbek wód podziemnych, podając przykłady konkretnych rozwiązań organizacyjno-technicznych. Przytoczono podstawowe dokumenty normujące proces opróbowania oraz istniejące poradniki. Omówiono potencjalne zagrożenia związane z pracą w terenie, przedstawiono zróżnicowane sposoby poboru próbek, stosowane w zależności od rodzaju punktu monitoringowego. Scharakteryzowano najczęściej wykorzystywane w monitoringu wód podziemnych rodzaje pojemników i utrwalaczy, a także pomiary parametrów fizykochemicznych wskaźników nietrwałych wykonywane in situ.
The crucial element of groundwater monitoring is the properly carried out groundwater sampling, which includes not only the stage of collecting samples, but also all activities related to samples preservation, storage, transport to the laboratory and also field measurements of unstable indicators. In view of variability of possible situations, the actual field exploration may diverge from shown in literature schemes. Making use of multi-year experience, the authors present the practical aspects of groundwater sampling, giving the examples of concrete organise-technical solutions. The basic norms and guides concerning sampling were detailed. The potential dangers related to work in the field were discussed. Multiple techniques of sampling, considering sampling site type, were presented. There were characterised the most common in groundwater monitoring types of containers and preservatives and also basic measurements of unstable physic-chemical parameters performed in situ.
Źródło:
Biuletyn Państwowego Instytutu Geologicznego; 2013, 456 Hydrogeologia z. 14/2; 659--663
0867-6143
Pojawia się w:
Biuletyn Państwowego Instytutu Geologicznego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ metodyki opróbowania na niepewność oznaczeń jodków w wodach powierzchniowych Zlewni Górnej Odry i w wodach kopalnianych do niej odprowadzanych
Influence of sampling method on uncertainty associated with iodide determination in Upper Odra River Basin surface water and coalmine water inducted to it
Autorzy:
Drzymała, M.
Powiązania:
https://bibliotekanauki.pl/articles/203903.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
niepewność pomiaru
próbki kontrolne dublowane
analiza wariancji
jodki
jakość wody
measurement uncertainty
control duplicate samples
variance analyses
iodide
water quality
Opis:
Zgodnie z obowiązującymi przepisami Unii Europejskiej (RDW2000; DWP 2006; DT 2009) monitoring jakości wód powierzchniowych i podziemnych powinien obejmować m.in. identyfikację wszystkich źródeł niepewności procedury analitycznej. Ponadto dyrektywa (DT 2009) oraz rozporządzenie (RMOE 2011) wskazują na konieczność prowadzenia programu zapewnienia i kontroli jakości (QA/QC) badań w monitoringu wód, a także podają wartość graniczną niepewności pomiaru szacowanej na poziomie odpowiednich norm jakości środowiska równej 50% lub mniejszej (k = 2).W rozporządzeniu (RMOE 2011) określono również metody referencyjne stosowane w monitoringu wód. W niniejszej pracy zastosowano empiryczne podejście (Nordest 2006,2007;Witczak i in. 2006; EURACHEM 2007; Kmiecik 2008; Kmiecik, Drzymała 2008; Kmiecik 2011) do oszacowania wartości niepewności całkowitej oraz jej składowych: niepewności geochemicznej, niepewności opróbowania i niepewności analitycznej. Dodatkowo zbadano wpływ metodyki poboru próbek na niepewność pomiaru. Do oceny niepewności wykorzystano wyniki analiz próbek normalnych i kontrolnych (dublowanych), pobranych w ramach monitoringu wód powierzchniowych Zlewni Górnej Odry oraz wód kopalnianych do niej odprowadzanych. Szacowanie niepewności całkowitej i jej komponentów pokazano na przykładzie wyników oznaczeń I– w próbkach normalnych i dublowanych. Określono wpływ rodzaju pojemnika na niepewność pomiaru. W tym celu zastosowano dwie procedury poboru próbek, obejmujące zastosowanie dwóch różnych pojemników na próbki. Analizę zawartości I– wykonano metodę ICP-MS w akredytowanym Laboratorium Hydrogeochemicznym. Każda z próbek poddana była dwukrotnej analizie. Do oszacowania wartości niepewności całkowitej i jej składowych zastosowano program ROBAN.
According to European Union present legal state (RDW2000; DWP 2006; DT 2009) surface and ground water quality monitoring should also include identification of all uncertainty associated with analytical procedure sources. Moreover, directives (DT 2009; RMOE 2011) indicate necessity of implementation the quality assurance and quality control program(QA/QC) of research in water monitoring. They also give the measurement uncertainty threshold value assesst basing on adequate norms of environment quality and is equal to 50% or less (k=2). In directive (RMŚ 2011) there are also defined reference methods, which should be use in water monitoring. In this paper the empirical approach for total uncertainty and its components (geochemical, sampling and analytical) assessment was used (Nordest 2006, 2007; Witczak et al. 2006; EURACHEM 2007; Kmiecik 2008; Kmiecik, Drzymała 2008; Kmiecik 2011). Moreover, the influence of sampling method on the measurement uncertainty was examined. For uncertainty estimation there were used results from analyses of normal and control (duplicate) samples, which were collected within monitoring of Upper Odra River Basin surface water and coalmine water inducted to it. The assessment of total uncertainty and its components was shown on the example of I- results delivered from normal and duplicate samples analyses. The influence of container type on measurement uncertainty was determined. For this aim two procedures of samples collecting were used, concerning two types of samples containers. The iodide analyses was performed using ICP-MS method in accredited Hydrogeochemical Laboratory Each sample was analysed twice. For total uncertainty and its components assessment the ROBAN program was applied.
Źródło:
Technika Poszukiwań Geologicznych; 2012, R. 51, nr 2, 2; 63-75
0304-520X
Pojawia się w:
Technika Poszukiwań Geologicznych
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies