Tytuł:
EtCO2 -Based Biofeedback Method of Breath Regulation Increases Speech Fluency of Stuttering People
Autorzy:
Stankiewicz, B.
Zieliński, K.
Darowski, M.
Michnikowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/176680.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
stuttering therapy
respiratory disturbances
end-tidal CO2
acoustic signal of an utterance
visual feedback
Opis:
Respiratory disturbances frequently accompany stuttering. Their influence on lung ventilation can be assessed by measurement of the end-tidal CO2 concentration (EtCO2). The effectiveness of the CO2-based visual feedback method of breath regulation (VF) designed for stuttering therapy was tested in this study. The aim of the study was to answer the question if the VF helps to reduce respiratory disturbances in stuttering and increase speech fluency. 20 stuttering volunteers aged 13–45 years took part in the 3-parts test consisting of: 1. speaking without any techniques improving speech fluency, 2. learning the VF method, 3. VF-assisted speaking. The CO2/time signal and an acoustic signal of an utterance were recorded during the test. Significant increase of FE – the factor of breath ergonomics during speaking (based on both signals), from 47% to 71% (P < 0.01), and significant decrease of %SS – the percent of syllables stuttered, from 14% to 10% (P < 0.01) were received for VF-assisted utterances compared to the utterances without VF assistance. The results indicate that the VF can help to eliminate respiratory disturbances in stuttering and increase speech fluency.
Źródło:
Archives of Acoustics; 2015, 40, 4; 469--474
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Urządzenie ECP-100 do nieinwazyjnego wspomagania układu krążenia wykorzystujące metodę kontrpulsacji zewnętrznej
Autorzy:
Bachorz, M.
Godecki, M.
Darowski, M.
Kozarski, M.
Powiązania:
https://bibliotekanauki.pl/articles/261626.pdf
Data publikacji:
2009
Wydawca:
Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki. Katedra Inżynierii Biomedycznej
Tematy:
kontrpulsacja zewnętrzna
niedokrwienie serca
układ krążenia
counterpulsation
cardiovascular system
ischemia
Opis:
Urządzenie ECP-100, opracowane przez ITAM Zabrze przy współpracy z 1B1B PAN Warszawa, umożliwia terapię pacjentów z chorobą niedokrwienną serca. Podczas zabiegu pacjent z zestawem mankietów pneumatycznych spoczywa na leżu zabiegowym. Zestaw składa się z trzech mankietów (podobnych do tych stosowanych przy pomiarze ciśnienia), które są owinięte dookoła łydek, ud i pośladków. Mankiety są napełniane sekwencyjnie na początku fazy rozkurczu serca i opróżniane przed fazą skurczu. Napełnianie i opróżnianie mankietów jest zsynchronizowane z przebiegiem EKG, tak by zoptymalizować korzyści terapeutyczne.
Źródło:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna; 2009, 15, 1; 52-53
1234-5563
Pojawia się w:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A hybrid (hydro-numerical) circulatory model: investigations of mechanical aortic valves and a numerical valve model
Autorzy:
Kozarski, M.
Suwalski, P.
Zieliński, K.
Górczyńska, K.
Szafron, B.
Pałko, K. J.
Smoczyński, R.
Darowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/202199.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
biological and mechanical heart valves
numerical heart valve
hybrid (hydro-numerical) circulatory model
voltage-controlled hydraulic pressure (flow) source
hydraulic input impedance
varying-elastance left ventricle
Opis:
In most cases of diseased heart valves, they can be repaired or replaced with biological or mechanical prostheses. Biological prostheses seem to be safer than mechanical ones and are applied with good clinical outcomes. Their disadvantage, when compared with mechanical valves, is durability. In the development and application of mechanical and biological heart valves, a significant role can be played by a Hybrid (Hydro-Numerical) Circulatory Model. The aim of this paper is to demonstrate the opportunities created by the hybrid model for investigations of mechanical heart valves and their computer models under conditions similar to those of the circulatory system. A diode-resistor numerical valve model and three different design mechanical aortic valves were tested. To perform their investigations, computer applications were developed under RT LabView to be run on a PC. Static and dynamic characteristics of the valves were measured and registered - pressure in the numerical time-varying elastance left ventricle (pLV), in the aorta (pas) and flow (f), proving, among other factors, that 1) time delay of pas with respect to pLV is mainly related to the valve’s opening time, and 2) the valves of substantially different designs tested under identical hydrodynamic conditions reveal nearly the same dynamic performance.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2015, 63, 3; 605-612
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A new hybrid (hydro-numerical) model of the circulatory system
Autorzy:
Darowski, M.
Kozarski, M.
Ferrari, G.
Zieliński, K.
Górczyńska, K.
Szczepanowski, A.
Pałko, K. J.
Fresiello, L.
Di Molfetta, A.
Powiązania:
https://bibliotekanauki.pl/articles/199804.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
lumped parameter circulatory model
hybrid hydro-numerical models
impedance transformers
LVAD assistance
variable elastance
Opis:
The paper presents a hybrid (hydro-numerical) circulatory model built to be used as a complementary tool for clinical purposes. It was developed at the Institute of Biocybernetics and Biomedical Engineering - Polish Academy of Sciences (Poland) in co-operation with the Institute of Clinical Physiology - National Council of Research (Italy). Main advantages of the model are: 1) high accuracy and repeatability of parameters setting, characteristic of numerical solutions, 2) maximum flexibility achieved by implementing the largest possible number of the model’s elements in the numerical way, 3) ability to test mechanical heart assist devices provided by special computer applications; in the model two physically different signal environments - numerical and hydraulic - are connected by special impedance transformers interfacing physical and numerical parts of the model; 4) eliminating flowmeters, as the voltage controlled flow sources embedded in the system provide information on flows. In vitro tests were performed to evaluate the circulatory model: a) modelling and simulation of physiological and pathological states parameters vs. left ventricular end-systolic elastance (Emax l) and rest volume (Vol) variations, b) testing the effect of LVAD counterpulsation on circulatory hemodynamics and ventricular energetics; it resulted in the increase of total cardiac output (COLV tot) from pathological value 3.8 to 5.4 l·min−1, mean aortic pressure mPas from 67.8 to 96.1 mmHg and in the decrease of left atrial pressure mPla from 15.7 to 7.7 mmHg and External Work nEW by 37.5%. The model was verified based on literature data.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2013, 61, 4; 993-1003
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies