Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Dabrowski, T.J." wg kryterium: Autor


Tytuł:
Zmniejszenie uciążliwości zapachowych oczyszczalni ścieków w Tychowie
Reduction of Odorous Noxiousness of Sewage Treatment Plant in Tychowo
Autorzy:
Piecuch, T.
Kowalczyk, A.
Dąbrowski, T.
Dąbrowski, J.
Andriyevska, L.
Powiązania:
https://bibliotekanauki.pl/articles/1818190.pdf
Data publikacji:
2015
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
odory
zapach
olejki eteryczne
flokulant
osady ściekowe
odwadnianie
odours
scent
essential oils
flocculant
sewage sludge
dewatering
Opis:
The most important aim of the study was to find the optimum conditions of the process of dewatering of sewage sludge using decanter centrifuge, and also reduce noxiousness of the centrifuge service, by applying orange essential oil as a partial substitute of flocculants. The tests were performed at sewage treatment plant in Tychowo where dewatering process of sewage sludge is carried using decanter centrifuge ALFA LAVAL, type ALDEC with application of different proportions of orange essential oil mixed with ZETAG® 9048FS flocculant for dose C = 76.3 dm3/m3. Water content in the sediment, dry matter content in effluent and concentration of orange essential oil odour in dewatered sediments were assessed. Conducted tests proved that orange essentials oil is a efficient, good flocculant, which may be used as an addition do centrifugal sedimentation process. Addition of orange essential oil has a substantial advantage: it causes the decrease of odorous noxiousness of dewatered sediments. The experiments were conducted on-site in the sewage treatment plant in the centrifuge station. Analysis of odorous noxiousness was conducted in the laboratory using samples collected on-site. Odorous noxiousness was assessed by determination of oudour concentration. Measurements were made using method of dynamic olfactometry according to standard PN-EN 13725:2007 [14] on four station olfactometer T08 (figure 1) equipped with all necessary apparatus. One measurement consisted of four series. Computer software colleted all the measurements results and calculated result of the measurement team (Zite, pan) –geometric mean of all individual measurements. This value is at the same time the concentration of odour in the sample (cod), expressed in european odorous units per cubic meter (ouE/m3) in accordance with PN-EN 13725:2007 [14]. As a result of conducted tests, taking into account good quality of dewatering of sludge with simultaneous, partial, but clear and noticeable reduction of noxious odours emitted from the sediments, both reagents are recommended for dosage that is ZETAG® 9048FS flocculant and orange essential oil, both 50% of the dose volume. It is advisable to conduct further research on the use of essential oils from other plants as flocculants in the broadly defined processes of water and sludge technology, as well as conducting works on the economic production of essential oils form waste materials, also including the logistics of their separation at the selection of waste stage, or their acquisition from fruit processing plants.
Źródło:
Rocznik Ochrona Środowiska; 2015, Tom 17, cz. 1; 646-663
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie stron internetowych w komunikowaniu polityki społecznej odpowiedzialności przez spółki publiczne notowane na GPW w Warszawie
The role of websites in communicating CSR policy by public companies listed on the Warsaw Stock Exchange
Autorzy:
Dabrowski, T.J.
Powiązania:
https://bibliotekanauki.pl/articles/888234.pdf
Data publikacji:
2019
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Źródło:
Zeszyty Naukowe Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie. Polityki Europejskie, Finanse i Marketing; 2019, 22[71]
2081-3430
Pojawia się w:
Zeszyty Naukowe Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie. Polityki Europejskie, Finanse i Marketing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ nieznacznych ilości DDT w pożywieniu na zmiany zachodzące w surowicy i w wątrobie białych szczurów
Effect of minute amounts of DDT in foods on blood plasma and liver changes in rat
Autorzy:
Dabrowski, T.
Zawistowski, S.
Wierzchowski, J.
Powiązania:
https://bibliotekanauki.pl/articles/875916.pdf
Data publikacji:
1961
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Źródło:
Roczniki Państwowego Zakładu Higieny; 1961, 12, 1
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ustalenie warunków technologicznych pracy podczyszczalni ścieków palarni kawy MK-Cafe w Skibnie
Determining of technological conditions of sewage pre-treatment from coffee roasting plant in Skibno
Autorzy:
Dąbrowski, J.
Dąbrowski, T.
Kościelnik, B.
Malej, J.
Piecuch, T.
Piekarski, J.
Kościerzyńska-Siekan, G.
Chanulak, D.
Wolski, H
Powiązania:
https://bibliotekanauki.pl/articles/1826310.pdf
Data publikacji:
2000
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
podczyszczalnia ścieków
skład jakościowy ścieków
palarnia kawy
Opis:
Od kwietnia 1999 trwają prace badawcze nad ustaleniem warunków quasi optymalnych pracy układu technologicznego podczyszczalni ścieków w Palarni Kawy w Skibnie prowadzone przez Katedrę Technologii Wody, Ścieków i Odpadów Politechniki Koszalińskiej. Zaprojektowany w Katedrze i wybudowany układ jak na schemacie maszynowym rys. 1 [1] został przedstawiony fragmentarycznie na fotografii 1 oraz na fotografii 2 fragment hali podczyszczalni ścieków. Według technologii ścieki surowe wprowadza się do zbiornika koagulacyjnego - rys. 1 o pojemności roboczej 5m3. Zbiornik ten ma zainstalowane wolnoobrotowe mieszadło z falownikiem. W celu zdekantowania jak największej ilości cieczy nadosadowej zbiornik posiada trzy poziomy przelewowe. Po 24 godzinnym procesie sedymentacji przelew odprowadza się do rząpia, a wylew - na filtr grawitacyjny piaskowy. Następnie ciecz nadosadowa zawracana jest pompą do zbiornika koagulacyjnego, gdzie poddawana jest procesowi napowietrzania. Po procesie napowietrzania i sedymentacji ciecz nadosadowa kierowana jest do procesu filtracji, po czym przechodzi na kolumnę sorpcyjną. Celem niniejszej publikacji jest przedstawienie ostatecznych wyników badań przeprowadzonych w tym układzie w Palarni Kawy MK-Cafe w Skibnie. W trakcie wielu badań [1,3] stwierdzono istotną różnicę składu jakościowego ścieków popłucznych. Wynika to z faktu, że w Palarni Kawy w Skibnie są przetwarzane dwa rodzaje kawy: Robusta - o gorszej charakterystyce wskaźników zanieczyszczeń ścieku (większy ładunek zanieczyszczeń), na którym przeprowadzono badania przedstawione w tej publikacji oraz Arabica - o charakterystyce zanieczyszczeń łatwiejszej do oczyszczenia (mniejszy ładunek zanieczyszczeń). W tabeli 1 przedstawiono wskaźniki zanieczyszczeń ścieku surowego zbliżonego do najgorszego ścieku otrzymywanego w procesie produkcyjnym w Palarni Kawy w Skibnie.
Research work, done by the Division of Water, Wastewater and Wastes Technology, on determining quasi-optimal conditions of work of technological system of sewage from Coffee Roasting Plant in Skibno pre-treatment has been going on since April 1999. The system designed in the Division and built according to the machine diagram (Fig. 1) [1] is shown fragmentarily on photograph 1 and fragment of sewage pretreatment hall on photograph 2. According to technology the raw sewage is poured into coagulation tank, Fig. 1, with working volume of 5 m3. This tank has a slow rotary mixer with inverter installed inside. In order to decant as much sedimentation water as possible, the tank has been furnished with three overflow levels. After 24 hours of sedimentation clarified water is poured into a concrete tank, and sludge on gravitational sand filter. Then the clarified water is pumped back to the coagulation tank, where it is aerated. After aeration process the clarified water is directed to the filter and then it goes to the sorptional column. Technological hall has a steel construction with 4x4x4.5 m of dimensions. Roof and walls are made of PW-8 plates. Investment costs of building part came to 67.000 zł. Building works were made by STOLREM - Koszalin Company. Investment costs of machine part, that is: coagulation tank, filtration column, sorptional column, pumps came to about 52.000 zł. Devices were made by EKOTECHNIKA - Koszalin Company. So the total investment cost came to 119.000 zł - in prices from first half of 1999. During many tests essential difference of qualitative composition of post rinsing wastewater was revealed. This results from the fact, that in the Coffee Roasting Plant in Skibno two kinds of coffee are produced: Arabica - with worse characteristics of wastewater contamination indexes (higher contaminants load), which was treated during research presented in this paper, and Robusta - with contamination characteristics easier to remove (lower contaminants load). Raw wastewater, which characteristics is shown in Table 1, is first treated using coagulation process in coagulation tank 1 (Photo 1). Bentonite and calcium hydroxide Ca(OH)2 are used as coagulants. Reagents dose depends on the kind of post-rinsing wastewater. For more polluted wastewater dose of reagents is: 2 kg Ca(OH)2/m3 of wastewater and 0.2 kg bentonite/m3 of wastewater. For the wastewater with lower contaminants load dose of reagents is: 1 kg Ca(OH)2/m3 of wastewater and 0.2 kg bentonite/m3 of wastewater. After 24 hours of sedimentation process decanted sedimentation water is directed to the filtration process, and then sorption process. Filtration column 2 (Photo 1) with 0.75 m of height, is filled with gravel which grains diameter is in the range of 0,5÷1,2 mm. The sorption process 3 (Photo 1) is conducted on the active carbon WA 1÷4. Columns are washed with technological water, what for sure has influence on results worsening. Post coagulation sludge from the tank is directed to the gravitation sand filter 4 (Photo 1) with area of 4 m2. Outflow was not analysed, it is directed back to the coagulation process along with raw wastewater from production. During conducting research it turned out, that correction of pH index is necessary. Excessive value of pH index is caused by calcium hydroxide usage, which increases precipitation of metals hydroxides and other sediments increasing pH value at the same time [2]. This problem is solved using wastewater aeration, when CO2 as a acid anhydride causes decrease of pH value. Wastewater are aerated eight hours. Conducted research allows to draw certain general conclusions: Technological system for post-rinsing sewage pre-treatment in the Coffee Roasting Plant in Skibno with the highest contaminants load requires application of filtration bed before sorption process, To reduce sewage pollution index - pH it is necessary to apply aeration, The stuff of the wastewater pre-treatment plant cannot let the filtration bed and the sorptional bed dry up - it always has to be flooded with wastewater or water, All indexes of raw sewage pollution have reached standard values, allowing to pipe off sewage to open reservoirs and ground waters.
Źródło:
Rocznik Ochrona Środowiska; 2000, Tom 2; 114-123
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The quantitative changes of ground beetles (Col., Carabidae) in Bt and conventional maize crop in southern Poland
Autorzy:
Twardowski, J.P.
Beres, P.K.
Hurej, M.
Klukowski, Z.
Dabrowski, Z.T.
Sowa, S.
Warzecha, R.
Powiązania:
https://bibliotekanauki.pl/articles/65047.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
quantitative change
beetle
ground beetle
Coleoptera
Carabidae
Bt maize
conventional plant
maize
crop
Polska
Opis:
In the southern part of Poland, ground beetle fauna was studied in the first large-scale Bt maize experiment. The aim of this study was to determine the long term impact of the Bt maize cultivar in comparison to conventional plants, on selected non-target arthropods. The DKC 3421 YG cultivar (Bt maize) and the respective isogenic non-Bt varieties (DKC 3420) were cultivated at two locations: (a) Budziszów near Wrocław and in Głuchów near Rzeszów in the south-eastern region of Poland, in the 2008-2010 growing seasons. For comparative analysis, two additional non-Bt cultivars sprayed with a lambda-cyhalotrine insecticide were also included. To monitor population density of surface-active invertebrates of the Carabidae family, eighty pitfall traps were used at each location. The average number of ground beetle populations in the Bt-maize cultivar DKC 3421 YG did not significantly differ from the number of beetles in the conventional ones. Significant differences between the number of beetles occurred on individual dates only. Usually, these differences related to the considerably smaller total number of beetles in the whole replication. Probably, the variation in the number of beetles was caused by climatic factors or the terrain layout, therefore it cannot be related to the cultivar effect.
Źródło:
Journal of Plant Protection Research; 2012, 52, 4
1427-4345
Pojawia się w:
Journal of Plant Protection Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prototype Silicon Position-Sensitive Detector Working with Bragg-Brentano Powder Diffractometer
Autorzy:
Zięba, A.
Dąbrowski, W.
Gryboś, P.
Powroźnik, W.
Stobiecki, T.
Świentek, K.
Słowik, J.
Wiącek, P.
Powiązania:
https://bibliotekanauki.pl/articles/2030562.pdf
Data publikacji:
2002-05
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
07.85.-m
29.40.Wk
Opis:
A prototype 64-channel detector module, comprising a silicon strip detector with strip pitch of 100μm and 64-channel ASIC RX64, was tested with the X-Pert Philips MPD diffractometer. Basic parameters of the detector module, energy resolution, and detection efficiency, were evaluated as a function of the counting rate. Energy resolution of 1.1 keV FWHM for photon rate up to 1×10$\text{}^{7}$ photon/s per 1 cm of the active width of the detector was demonstrated. The prototype detector, when applied in a diffractometer utilizing Bragg-Brentano focusing principle, allows to increase the counting rate by about 2 orders of magnitude with respect to a single counter. Exemplary diffraction patterns of polycrystalline samples of Si and SiO$\text{}_{2}$ (quartz peak cluster) are presented.
Źródło:
Acta Physica Polonica A; 2002, 101, 5; 629-634
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Propagation Effects in Photonic Liquid Crystal Fibers with a Complex Structure
Autorzy:
Tefelska, M.
Chychłowski, M.
Woliński, T.
Dąbrowski, R.
Rejmer, W.
Wójcik, J.
Powiązania:
https://bibliotekanauki.pl/articles/1506868.pdf
Data publikacji:
2010-12
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
42.81.Gs
78.20.Bh
42.79.Kr
Opis:
Chiral nematic liquid crystals are very interesting materials to infiltrate photonic crystal fibers since they are characterized by unique optical properties such as selective Bragg reflection, circular dichroism, and optical activity. In this paper the latest experimental results of the photonic crystal fibers filled with new chiral nematic liquid crystals are presented. Spectral properties of the light propagating in the photonic liquid crystal fibers have been measured and analyzed.
Źródło:
Acta Physica Polonica A; 2010, 118, 6; 1259-1261
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Produkcja i rozpylanie roztworów neutralizujących przykre zapachy w hali podczyszczalni ścieków Przedsiębiorstwa SUPERFISH
Production and spraying solutions neutralizing unpleasant smells in the wastewater pretreatment plant in SUPERFISH Company
Autorzy:
Piecuch, T.
Sasinowski, M.
Nowak, A.
Dąbrowski, J.
Kościerzyńska-Siekan, K.
Dworaczyk, J.
Zaremba, W.
Powiązania:
https://bibliotekanauki.pl/articles/1826122.pdf
Data publikacji:
2006
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
oczyszczanie ścieków
olejki zapachowe
olejki eteryczne
dezodoryzacja
Opis:
Celem głównym prowadzonych prac badawczych było otrzymanie roztworów neutralizujących przykre zapachy pochodne ścieków i osadów technologicznych, budowane na wywarze z płatków róży, liści mięty, skórek pomarańczy. Przeprowadzono również wstępną ocenę skuteczności neutralizacji przykrych zapachów za pomocą otrzymanych roztworów neutralizujących z ww. roślin, opartą o doświadczenie neutralizacji zapachu w hali technologicznej Przedsiębiorstwa SUPERFISH w Kukini koło Ustronia Morskiego.
Obtaining solutions neutralizing unpleasant smells from wastewater and technological deposits using rose petals, mint leaves, skins for orange was a main purpose of carried out research work. Also preliminary assessment of the effectiveness of neutralization of unpleasant smells using solutions obtained from given plants, based on experiments on smell in wastewater pretreatment plant in the SUPERFISH Company in Kukinia by Ustronie Morskie, Poland. The method of distillation with steam was applied in this work for the purpose of obtaining essential oils from plant material. Choice of this method is important to analysed plant material. It is applied at getting poorly watersoluble oils and the possible loss of soluble elements does not influence the quality of oil. This method is characterized by uncomplicated apparatus, as well as relatively low costs of carrying the process in comparing to other methods of obtaining oils. Apparatus for production of essential oils obtained from rose petals and mint leaves is presented in fig. 1. Apparatus for production of essential oils obtained from orange skins is presented in fig. 2. In order to determine if substance obtained using method of distillation with steam has aromatic properties, it was essential to create the system of testing and comparing studied substance against established standard. As a starting point standard substance was established, i.e. substance which gave no smell off during examinations. Distilled water was used here as a standard. Next five degree scale of smell intensity was determined contractually (table 1), where lowest degree of the scale "0" means the lack of the smell (standard), 1 is a weak smell, next: average perceptible smell, intense smell and very intense smell. In order to examine effectiveness of action of obtained aromatic solutions it was decided to spray the determined dose of each of them in the pretreatment plant of wastewater from a SUPERFISH fish- plant Examinations consisted in measuring the time of the fragrance duration of sprayed substance by the research team in two zones. It is possible to present the following conclusions on the base of analysis of ex-aminations carried out: As a result of distillation with the steam of substrates from rose, mint and orange, extracts characterized by aromatic properties were obtained. Obtained extracts, depending on the amount of substrate used for distillation, differed in intensity of the fragrance. Biggest concentration of aromatic substances (intense fragrance) in extract, were obtained for biggest amount of substrate used for the process of distillation. Extracts with biggest concentration of dissolved substances are characterized by an intense fragrance. Examinations carried out in the SUPERFISH wastewater pretreatment plant showed the effectiveness of obtained aromatic substances in the neutralization of unpleasant smells. The neutralization duration depends on the amount of substrate used for obtaining aromatic extract. The increase of extract concentration is lengthening duration of effective dezodorization. Research carried out in the wastewater pretreatment plant of SUPERFISH company showed good effectiveness of used fragrance substances in neutralization of unpleasant smells.
Źródło:
Rocznik Ochrona Środowiska; 2006, Tom 8; 239-261
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Próba oceny liczebności lerki Lullula arborea w ostoi Natura 2000 Puszcza Notecka w roku 2010
An attempt was made to assess the number of Woodlark Lullula arborea in the Puszcza Notecka Special Protection Area (SPA) in 2010
Autorzy:
Mizera, T.
Kujawa, D.
Cierplikowska, K.
Krajewska, A.
Kraskiewicz, A.
Takacs, W.
Bielewicz, M.
Chudzicki, M.
Cierplikowski, D.
Cykowiak, Z.
Dabrowski, G.
Gielda-Pinas, K.
Grzegorzek, M.
Pakula, M.
Pikula, A.
Sznajder, T.
Wasik, A.
Wieckowski, J.
Skorka, P.
Powiązania:
https://bibliotekanauki.pl/articles/881447.pdf
Data publikacji:
2011
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Leśny Zakład Doświadczalny. Centrum Edukacji Przyrodniczo-Leśnej w Rogowie
Tematy:
ptaki
lerka
Lullula arborea
liczebnosc
obszary specjalnej ochrony ptakow
Puszcza Notecka
Źródło:
Studia i Materiały Centrum Edukacji Przyrodniczo-Leśnej; 2011, 13, 2[27]
1509-1414
Pojawia się w:
Studia i Materiały Centrum Edukacji Przyrodniczo-Leśnej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optymalizacja struktury niezawodnościowej czujki temperatury w systemie bezpieczeństwa
Optimalisation of structure of reliable temperature sensor in a security system
Autorzy:
Paś, J.
Dąbrowski, T.
Powiązania:
https://bibliotekanauki.pl/articles/327860.pdf
Data publikacji:
2006
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
system bezpieczeństwa
czujka temperatury
symulacja komputerowa
security system
temperature sensor
computer simulation
Opis:
Każdy system bezpieczeństwa zainstalowany w obiekcie powinien posiadać podsystem sygnalizacji pożaru. Aby taki podsystem mógł wykonywać swoje zadania z określonym prawdopodobieństwem zdatności powinien posiadać optymalną strukturę wewnętrzną. W artykule zaproponowano, na podstawie symulacji komputerowej, określoną strukturę czujki temperatury, która wchodzi w skład systemu ochrony obiektu. Dla optymalnej struktury czujki temperatury zaproponowano rozwiązanie układowe gwarantujące wymaganą czułość oraz prawdopodobieństwo zdatności.
Each security system installed in an object should have a sub-system of fire security. Such a system should have an optimal internal structure so that it could perform its operation with a defined probability of avoioding damage. On the basis of computer simulation, the article proposes optimal structure of temperature sensor, which is part of a secured object. For an optimal structure of a temperature sensor, a project was proposed increasing sensibility and probability of avoiding damage.
Źródło:
Diagnostyka; 2006, 4(40); 93-100
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oczyszczanie ścieków ze stacji naprawy samochodów
Treatment of Wastewater from Car Service Station
Autorzy:
Piecuch, T.
Andriyevska, L.
Dąbrowski, J.
Dąbrowski, T.
Juraszka, B.
Kowalczyk, A.
Powiązania:
https://bibliotekanauki.pl/articles/1818559.pdf
Data publikacji:
2015
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
flotacja
ścieki zaolejone
podczyszczanie
flotation
oily wastewater
pretreatment
Opis:
The paper presents exploratory examinations on possibility of pre-treatment of wastewater containing gasoline and diesel fuel, that is wastewater “produced” in each car service and repair workshop and in gas station. It is a vast number of service points, which, though daily produce small amounts of wastewater but in the scale of the whole country amount of wastewater is substantial. Such wastewater is usually piped off into the sewage system. Often oily wastewater does not meet requirements set by local companies which own the municipal sewage treatment plants. Therefore, authors made have undertaken considerations on the concept of use the flotation process for pre-treatment of wastewater containing oil and gasoline, as a small wastewater treatment plant that could be installed in a separate room of garage or gas station. Example diagram is shown in Figure 5. This paper presents preliminary testing of a pilot-distinctive nature. Laboratory tests of flotation process were carried out in two independent study groups, ie. one with use of model wastewater and second with the use of real wastewater. Conducted examinations and analysis of the results allow to draw certain conclusions: 1. Wastewater from car service stations, mechanical garages and also gas stations are contaminated with oil derived compound, and although individual garage produces small amounts of wastewater, the sum of all wastewater in the scale of the whole country each day is substantial. 2. Proposed small installation for pre-treatment of oily wastewater, when implemented In the car service station or gas station will improve quality of wastewater daily inputted to sewage system. 3. The flotation process which is the first node of proposed technological installation does not treat wastewater sufficiently, but noticeably, and thus it allows to extend the life of an important node of the installation, that is sorption process. 4. Research should be continued on a small experimental plant installed in the car or gas station.
Źródło:
Rocznik Ochrona Środowiska; 2015, Tom 17, cz. 1; 814-832
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oczyszczanie ścieków przemysłowych z produkcji gazobetonu
Treatment of industrial wastewater from production of gas concrete
Autorzy:
Piekarski, J.
Piecuch, T.
Dąbrowski, T.
Powiązania:
https://bibliotekanauki.pl/articles/1825959.pdf
Data publikacji:
2008
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
beton komórkowy
ścieki przemysłowe
ścieki poprodukcyjne
oczyszczanie ścieków przemysłowych
technologie oczyszczania ścieków
Opis:
Celem pracy przedstawionej w ninniejszej publikaacji jest opracowwanie technologii oczyszczania poprodukcyjnych ścieków do jakości wody technologicznej , którą będzie można zawrócić do procesu produkcyjnego
Autoclaved gas concrete is counted to group of light concretes, which volumetric density does not exceed 2 000 kg/m3. There are several methods of production of the typical gas concrete applied in Poland. Components are only domestic mineral materials: binder - cement with the lime or lime itself, aggregate - sand or the mixture of sand with ash or ash from coal burning in power stations; fluffing agent: crumbled aluminum. Reaction of aluminum with calcium hydroxide, coming into being as the result of lime hydration or hydrolysis of cement, causes emission of hydrogen fluffs the mass passing through it and makes possible creation of pores. The air replaces hydrogen in fluffed mass. At present post-production wastewater from PREFABET in Reda is treated in the system, which is presented in the Figure 1. The aim of investigations, presented in this paper, was to work out technology of post-production wastewater treatment to the quality of technological water which can be turned back to production process [7]. Results of investigations of basic contamination parameters of raw wastewater from PREFABET Company in Reda coming from autoclaves are presented in Table 1. There are many methods of industrial wastewater treatment [1,3, 4,5]. Wastewater coming from PRFABET Company were treated under laboratory conditions according to the technology proposed by Authors shown in Figure 2. Overflow from the process of gravitational sedimentation currently piped off to sewage system or to the sludge drying bet located on the terrain of the company does not meet the standards. Furthermore sediments after process of gravitational sedimentation on filter sand makes up currently secondary waste, stored on a heap. Also demand for gas concrete increasing lately on the construction market causes the necessity to increase production, and at the same time causes creation of larger quantities of post-production wastewater. Technology of post-production wastewater treatment proposed by Authors solves presented problems. Post-production wastewater treated according to proposed technology is characterized by 100% reduction of contamination parameters: absorbance, turbidity, biochemical oxygen demand, total organic carbon and ether extract. 99% of reduction was noted for chemical oxygen demand, 63% for total suspension, and 41% for dissolved substances and dry residues. So treated wastewater may again be used in the process of gas concrete production, while dewatered sediments may be utilized in the process of solidification as the addition to the production of plates and cobble stones
Źródło:
Rocznik Ochrona Środowiska; 2008, Tom 10; 259-273
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ochrona i restytucja ekosystemów mokradłowych na terenie „Mazurskiego Parku Krajobrazowego”
Protection and restoration of marsh ecosystems at the area of the “Mazurian Landscape Park”
Autorzy:
Bieniaszewski, T.
Dabrowski, D.
Karetko, J.
Artych, P.
Skowron, S.
Powiązania:
https://bibliotekanauki.pl/articles/791432.pdf
Data publikacji:
2011
Wydawca:
Wyższa Szkoła Zarządzania Środowiskiem w Tucholi
Źródło:
Zarządzanie Ochroną Przyrody w Lasach; 2011, 05
2081-1438
2391-4106
Pojawia się w:
Zarządzanie Ochroną Przyrody w Lasach
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numeryczna metoda oceny sorpcji zanieczyszczeń ze ścieków
Numerical method for assessment of sorption process of contaminants from wastewater
Autorzy:
Piekarski, J.
Dąbrowski, T.
Powiązania:
https://bibliotekanauki.pl/articles/216897.pdf
Data publikacji:
2009
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
węgiel aktywny
sorpcja
modelowanie komputerowe
active carbon
sorption
computer modelling
Opis:
W artykule przedstawiono wyniki badań laboratoryjnych procesu sorpcji i analizę danych wykonaną za pomocą autorskiego programu komputerowego ANALIZA-LAB. Aplikacja umożliwia między innymi odczyt danych w trybie rzeczywistym z podłączonego do komputera urządzenia zewnętrznego (np. konduktometru) i na ich podstawie wykonanie analizy wpływu zależności parametrów zmiennych niezależnych na wartość parametrów zmiennych wynikowych, np. wartość wskaźnika ogólnego węgla organicznego, chemicznego zapotrzebowania na tlen, biochemicznego zapotrzebowania na tlen czy też zawiesiny ogólnej i substancji rozpuszczonych lub innych. ANALIZA-LAB można wykorzystać do analizy wyników badań, określania korelacji pomiędzy wskaźnikami i opisywania tych korelacji równaniami matematycznymi. Wyniki przedstawione w pracy potwierdzają, że ANALIZA-LAB jest pomocnym i użytecznym narzędziem do odczytu danych i ich analizy.
This paper presents results of a laboratory study on the sorption process of wastewater and analysis of data from the study using a recently developed computer application: ANALIZA-LAB. ANALIZA-LAB allows data to be read in real-time from an external device connected to a computer, such as a conductometer. This application can then analyse the influence of variable independent parameters on the value of output parameters such as the value of total organic carbon (TOC), chemical oxygen demand (COD), biochemical oxygen demand (BOD), total suspension, or dissolved substances. ANALIZA-LAB can be used to analyse examination results, determine correlation between parameters and describe that correlation using mathematical equations. The results presented in this paper confirm the usefulness of the ANALIZA-LAB application as a helpful and universal tool for data collection and analysis.
Źródło:
Gospodarka Surowcami Mineralnymi; 2009, 25, 1; 101-117
0860-0953
Pojawia się w:
Gospodarka Surowcami Mineralnymi
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metodyka nauczania diagnozowania systemów bezpieczeństwa na przykładzie systemów sygnalizacji włamania i pożaru
Methodology of teaching of diagnosing technical security systems with examples of system of signalization of burglary and fire
Autorzy:
Paś, J.
Dąbrowski, T.
Powiązania:
https://bibliotekanauki.pl/articles/327614.pdf
Data publikacji:
2008
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
włamanie
pożar
diagnozowanie
techniczny system ochrony
metodyka nauczania
burglary
fire
diagnosing
technical security system
methodology of teaching
Opis:
Podstawowym zadaniem systemów bezpieczeństwa instalowanych w obiektach budowlanych jest wykrywanie zagrożeń i powiadamianie o ich wystąpieniu w celu podjęcia odpowiednich działań. Instalowane w obiektach budowlanych techniczne systemy ochrony wymagają podczas eksploatacji wykonywania określonych sprawdzeń, na podstawie, których można postawić diagnozę. Wiarygodność diagnozy decyduje o dalszym istnieniu systemu (naprawa, wymiana czujek, wyłączenie systemu, wezwanie serwisu, itp.), co wiąże się z kosztami. W referacie przedstawiono metodykę nauczania diagnozowania złożonych systemów bezpieczeństwa na przykładzie systemów sygnalizacji włamania i pożaru.
The main task of security systems installed in objects is detection of emergencies, informing about them and, if it is possible, initializing respective countermeasures. Security systems used in buildings require diagnosing to identify their technical and functional condition. Likelihood of the obtained diagnosis decides about further actions (repair, replacement of sensors, calling for service, etc.), and this is connected with certain costs. This elaboration is an illustration of certain methodology of teaching of diagnosing a technical security system on the basis of systems of signalization of burglary and assault and signalization of fire.
Źródło:
Diagnostyka; 2008, 2(46); 101-104
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies