Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Czerwiński, Michał." wg kryterium: Autor


Wyświetlanie 1-7 z 7
Tytuł:
Distance to Radiotherapy and Demand – Projection of the Effects of Establishing New Radiotherapy Facilities in Poland by 2025
Autorzy:
Czerwiński, Adam Michał
Powiązania:
https://bibliotekanauki.pl/articles/1357371.pdf
Data publikacji:
2019-04-01
Wydawca:
Uniwersytet Warszawski. Wydział Nauk Ekonomicznych
Tematy:
radiotherapy
demand for healthcare
spatial interaction models
Opis:
In 2015, the Ministry of Health of the Republic of Poland introduced the Polish strategic plan for radiotherapy development and investment. Given that radiotherapy utilisation depends on the distance a patient must travel to undergo the treatment, the main goal of the plan was to increase equitable access to radiotherapy in Poland by establishing new facilities in new locations by 2025. This study constitutes the first step towards an economic evaluation of this plan by adopting spatial interaction models to project the expected increase in the demand for radiotherapy (3%). Moreover, it adds to the current research on the relation between distance and demand for healthcare services in the following ways. First, it flags the importance of using spatial econometrics to healthcare utilisation studies in the presence of spatial autocorrelation. Furthermore, it proposes a quantitative method for assessing the expected impact of establishing new facilities on utilisation. Finally, it formally confirms the dependence between radiotherapy utilisation and distance in Poland, which has been previously shown to exist in other countries.
Źródło:
Central European Economic Journal; 2017, 4, 51; 40 - 52
2543-6821
Pojawia się w:
Central European Economic Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Uncompleted polymerization and cytotoxicity of dental restorative materials as potential health risk factors
Autorzy:
Małkiewicz, Konrad
Wychowański, Piotr
Olkowska-Truchanowicz, Joanna
Tykarska, Marzena
Czerwiński, Michał
Wilczko, Marcin
Owoc, Alfred
Powiązania:
https://bibliotekanauki.pl/articles/986972.pdf
Data publikacji:
2017
Wydawca:
Instytut Medycyny Wsi
Tematy:
dental composites
cytotoxicity
degree of conversion
Opis:
Introduction. Composite materials used in dentistry indicate adverse biological effects in laboratory conditions. One reason for this activity is incomplete conversion of their polymer matrix, favoring chemical instability and release of biologically harmful components to the external environment. Aim. The aim of the study was to assess the degree of conversion of restorative materials commonly available on the European market and to examine the cytotoxic effects of their eluates in vitro. Material and methods. Using the Fournier transform infrared spectroscopy (FTIR) technique of analysis, the degree of polymer matrix conversion of 6 restorative materials was examined: Gradia Direct, Arkon, Filtek Z550, Herculite XRV, Tetric Evo Ceram, Charisma, polymerized with LED light. In order to assess the cytotoxicity of eluates of the studied materials obtained after 1 hour, 24 hours and 7 days, the MTT assay was used in cultured 3T3 cells. The results were statistically analyzed at significance level of p=0.05. Results. The conversion degree of the assessed polymers ranged from 31.56% for Tetric Evo Ceram to 75.84% for Arcon. The strongest (p=0.05) cytotoxic effect was demonstrated after 7-day observation of Tetric Evo Ceram eluates, reducing the metabolic activity of cells down to 56%. A positive correlation (r(x, y)=0.62) between the degree of conversion of composite materials and cytotoxic effects of their eluates on cell cultures was confirmed. Conclusions. 1. Restorative dental materials are chemically unstable in the conditions of the present study. 2. Polymer-based restorative dental materials available on the European market demonstrate cytotoxic properties constituting a potential threat to the patients’ health.
Źródło:
Annals of Agricultural and Environmental Medicine; 2017, 24, 4
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of aerodynamic parameters of solar plane airfoil using CFD modeling
Autorzy:
Jaszczur, Marek
Papis, Karolina
Książek, Michał
Czerwiński, Grzegorz
Wojtas, Gabriel
Koncewicz, Wojciech
Nabożna, Sylwia
Wójcik, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/2097896.pdf
Data publikacji:
2021
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
solar plane
aerodynamic parameters
CFD modeling
Opis:
The technology of solar-powered aerial vehicles requires enormous financial support and further development. For this purpose, the computational fluid dynamic can be used. In order to carry out necessary analyses and model development in this research, ANSYS Fluent software was used. Using the first version of the AGH Solar Plane model, preliminary analysis of lift, drag and tearing off the stream was performed. Four new geometries were prepared on which the flattening of upper surfaces for fixing solar panels was tested. The results were validated in the aerodynamic tunnel using particle image velocimetry method. Taking into account all analyses, a number of recommendations have been prepared that will be implemented to create an aircraft, which meets all target requirements.
Źródło:
Computer Science; 2021, 22 (1); 123-142
1508-2806
2300-7036
Pojawia się w:
Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie zawartości wybranych metali ciężkich w separatorze polimerowym akumulatora kwasowo-ołowiowego
Analysis of the selected heavy metals content in the lead-acid battery polymeric separator
Autorzy:
Kolasa, Dorota
Łukomska, Aneta
Sołtysiak, Joanna
Soszko, Michał
Ciężarek, Olga
Lach, Jakub
Wróbel, Kamil
Czerwiński, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/947358.pdf
Data publikacji:
2019
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Chemii Przemysłowej
Tematy:
separatory elektrod
polietylen
oznaczanie metali ciężkich
mineralizacja mikrofalowa
absorpcyjna spektrometria atomowa z atomizacją w płomieniu (FAAS)
analizator rtęci
skaningowa mikroskopia elektronowa/spektrometria dyspersji energii promieniowania rentgenowskiego (SEM/EDS)
spektroskopia w podczerwieni z transformacją Fouriera (FT-IR)
electrode separators
polyethylene
heavy metals determination
microwave-assisted digestion
flame atomic absorption spectrometry (FAAS)
mercury analyzer
scanning electron microscopy/energy dispersive X-ray spectrometry (SEM/EDS)
Fourier transform infrared spectroscopy (FT-IR)
Opis:
W materiale polimerowym stosowanym jako separator elektrod w akumulatorze kwasowo-ołowiowym oznaczano zawartość kadmu, ołowiu i rtęci. W kontekście obowiązujących przepisów dotyczących wprowadzanych do obrotu baterii i akumulatorów oraz przetwarzania zużytych baterii i zużytych akumulatorów porównano wyniki badania próbek separatora przed użyciem w procesach elektrochemicznych oraz próbek odpadowych. W badaniach separatora [poprzedzonych analizą jakościową tworzywa metodami: skaningowej mikroskopii elektronowej/spektrometrii dyspersji energii promieniowania rentgenowskiego (SEM/EDS) i spektroskopii w podczerwieni z transformacją Fouriera (FT-IR)] wykorzystano nowoczesny aparat do mikrofalowego roztwarzania próbek w połączeniu z techniką absorpcyjnej spektrometrii atomowej z atomizacją w płomieniu (FAAS) i analizatorem rtęci. Zastosowane procedury analityczne weryfikowano na podstawie wyników badania certyfikowanego materiału odniesienia (PE-LD) zawierającego śladowe ilości analitów.
Results of cadmium, lead and mercury determination in the polymeric material used as an electrode separator in the lead-acid battery have been presented. Samples of the separator before use in the electrochemical processes and the waste separator samples have been compared with reference to the existing laws on batteries and accumulators and waste batteries and accumulators. In the polymer separator examination [preceded by a qualitative analysis of the material using scanning electron microscopy/ energy dispersive X-ray spectrometry (SEM/EDS) and Fourier transform infrared spectroscopy (FT-IR) techniques], a modern UltraWAVE digestion system combined with flame atomic absorption spectrometry (FAAS) technique and a DMA-80 Direct Mercury Analyzer has been used. The quality of metal determination results has been evaluated using a certified PE-LD reference material containing trace amounts of analytes.
Źródło:
Polimery; 2019, 64, 6; 442-451
0032-2725
Pojawia się w:
Polimery
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies