Tytuł:
The Application of the Selected Time-Frequency Descriptors Detection of the Acoustic Emission Signals Generated by Multisource Partial Discharges
Autorzy:
Cichon, A.
Powiązania:
https://bibliotekanauki.pl/articles/1795791.pdf
Data publikacji:
2009-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
52.80.-s
43.28.Js
Opis:
The paper presents the comparative analysis results of the acoustic emission signals generated by various forms of partial discharges occurring in multisource systems. Modern methods of the signal digital processing: a short-time Fourier transform and continuous and discrete wavelet transforms were applied for the assessment of the results in the time-frequency domain. The acoustic emission signals generated by partial discharges were registered with a WD AH17 contact transducer by the Physical Acoustics Corporation placed on the external part of the tub.
Źródło:
Acta Physica Polonica A; 2009, 116, 3; 290-293
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Characterization of surface type partial discharges using electrical, acoustic emission and UHF methods
Autorzy:
Kunicki, M.
Cichoń, A.
Powiązania:
https://bibliotekanauki.pl/articles/114691.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
partial discharges
PD measurements
UHF method
AE method
IEC60270
transformer fault diagnosis
Opis:
This paper presents research results related to measurements of partial discharges (PD), which may occur in oil insulation systems of electric power transformers. Three measuring methods were considered: electrical (apparent charge - IEC60270), acoustic emission (AE) and ultra-high frequency (UHF) method. Research works have been proceeded under laboratory condition. PD were generated using special apparatus and spark gap configuration for surface PD modeling. Measurements were performed simultaneously for each of the regarded methods and were repeated for selected supply voltage levels. The electrical and UHF methods measurements were made using MPD measuring system from Omicron. The AE method measurements were made using a piezoelectric transducer, which was installed on the outer transformer tank wall. Comparative analysis of signals gathered during research works was made. Possibilities of application of the three considered PD detection methods for electric power systems with oil insulation were proposed in the paper.
Źródło:
Measurement Automation Monitoring; 2015, 61, 1; 12-15
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Time and frequency domain analysis of partial discharges using electrical method
Autorzy:
Kunicki, M.
Cichoń, A.
Powiązania:
https://bibliotekanauki.pl/articles/973070.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
partial discharges
electrical method
IEC 60270
frequency domain
time domain
Opis:
Partial discharge (PD) measurement results with particular consideration of time domain and frequency domain analysis of pulses generated by PD model sources are presented in the paper. Three different PD generation model sources are selected for the research: surface type, point to point and multi-point to plate. All measurements are proceeded under laboratory conditions using electrical method of a PD detection, according to the IEC60270 standard. Various amplitude and power density spectrum descriptors are proposed, as well as PD source type identification abilities on grounds of the selected descriptors are considerated. Electrical power transformers on-line PD detection and evaluation systems improvement and development are the main purpose of the presented research. Laboratory experiment results gives a solid base for further research focused on verification of the proposed methodology on a real life apparatus.
Źródło:
Measurement Automation Monitoring; 2016, 62, 2; 72-77
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of a Phase Resolved Partial Discharge Pattern Analysis for Acoustic Emission Method in High Voltage Insulation Systems Diagnostics
Autorzy:
Kunicki, M.
Cichoń, A.
Powiązania:
https://bibliotekanauki.pl/articles/177912.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
acoustic emission
partial discharge
transformer diagnostics
insulation system
Opis:
An alternative method for analysis of acoustic emission (AE) signals generated by partial discharges (PD), based on a correlation between voltage phase run and AE pulses, so called phase resolved PD pattern (PRPD), is presented in the paper. PRPD pattern is a well-known analysis tool commonly used in such PD diagnostic methods as conventional electrical and UHF ones. Moreover, it yields various signal analysis abilities and allows a direct correlation indication between measurement results achieved using different methods. An original PRPD measurement methodology applied for AE method as well as some exemplary measurement results and further data analysis capabilities are presented in the paper. Also a comparative analysis of PRPD patterns achieved using various measurement methods and different PD source configurations have been investigated. All presented experiments were done under laboratory conditions using PD model sources immersed in the insulation oil. The main purpose of the presented research is to indicate an all-embracing analytical tool that yields an ability to direct comparison (qualitative as well as quantitative) of the AE measurement results with other commonly applied PD measurement methods. The presented results give a solid fundamental for further research work concerning a direct correlation method for AE and other described in the paper diagnostic techniques, mainly in order to continue PD phenomena analysis and assessment in real life high voltage apparatus insulation systems under normal onsite operation conditions.
Źródło:
Archives of Acoustics; 2018, 43, 2; 235-243
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie klasyfikatora neuronowego w systemie eksperckim oceny stanu układów izolacyjnych transformatorów elektroenergetycznych
The Application of a Neural Classifier in an Expert System for the Evaluation of the Condition of Power Transformer Insulation System
Autorzy:
Boczar, T.
Borucki, S.
Cichoń, A.
Powiązania:
https://bibliotekanauki.pl/articles/153524.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
wyładowania niezupełne
sieci neuronowe
system ekspercki
układ izolacyjny
transformator elektroenergetyczny
partial discharge
artificial neural network
expert's system
paper-oil insulation
power transformer
Opis:
Tematyka artykułu dotyczy oceny możliwości wykorzystania jednokierunkowej sieci neuronowej w systemie eksperckim diagnostyki stanu układów izolacyjnych transformatorów elektroenergetycznych. W artykule przedstawiono teoretyczne i praktyczne możliwości budowy systemu ekspertowego, bazującego na metodzie emisji akustycznej, wspomagającego diagnostykę układów izolacyjnych transformatorów dużej mocy. Zamieszczone w pracy wyniki przedstawiają skuteczność rozpoznawania badanych form WNZ (defektów izolacji), uzyskaną przy zastosowaniu klasyfikatora neuronowego, jak również ocenę możliwości jego zastosowania jako mechanizmu wnioskującego komputerowego systemu diagnostycznego.
The subject matter of the paper refers to the evaluation of the application possibilities of a single-direction neural network in the expert system of the diagnostics of the insulation system condition. The paper presents theoretical and practical possibilities of building an expert system based on the acoustic emission method, assisting the diagnostics of insulation systems of high power transformers. The results presented in this paper show the recognition effectiveness of the PD forms under study (insulation defects), obtained by using a neural classifier as well as the evaluation of its application possibilities as an inferring mechanism of a computer diagnostic system.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 10, 10; 29-32
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena stanu technicznego transformatorów elektroenergetycznych z wykorzystaniem metody emisji akustycznej
Diagnostics of technical condition of power transformers with use of the Acoustic Emission Method
Autorzy:
Skubis, J.
Borucki, S.
Cichoń, A.
Powiązania:
https://bibliotekanauki.pl/articles/153873.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
transformator elektroenergetyczny
metoda emisji akustycznej
wyładowania niezupełne
izolacja papierowo-olejowa
diagnostyka
power transformer
acoustic emission method
partial discharges
paper-oil insulation
diagnostic
Opis:
Tematyka artykułu dotyczy wykonanych przez pracowników Politechniki Opolskiej badań związanych z detekcją, oceną intensywności i lokalizacją wyładowań niezupełnych metodą emisji akustycznej w trzech transformatorach elektroenergetycznych o mocach 125, 160 i 400 MVA. Rezultatem przeprowadzonych prac było sformułowanie rekomendacji technicznych dotyczących aktualnego stanu technicznego badanych jednostek. Analizę zarejestrowanych impulsów akustycznych przeprowadzono w dziedzinie czasu, częstotliwości i czasowo-częstotliwościowej.
An important part of a comprehensive evaluation of the technical condition of power transformers is detection, assessment of the intensity and location of partial discharges (PDs), that may occur in their paper-oil insulation systems. Modern monitoring techniques are increasingly using the acoustic emission (AE) method, which combines the features of the gas chromatography and electricity methods, to evaluate the electrical discharge. The paper presents investigations performed by a team of the Opole University of Technology dealing with the detection, evaluation, intensity and location of PDs by means of the AE method for three transformers of 125, 160 and 400 MVA power. The result of this work was formulation of technical recommendations for the current technical condition of units. The analysis of the recorded pulses EA was conducted in the time, frequency and time-frequency domain. The paper generally characterizes the possibility of the AE method, and the used measuring system (Fig. 1). There are given the technical parameters of the energy object under study (Figs. 2, 7 and 11). The results of detection, assessment of the intensity and location of electrical discharges in transformers diagnosed are shown in Figs. 3, 5, 6, 9, 10, 13, 14 and Tables 1-4.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 4, 4; 343-347
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena możliwości wykorzystania sygnałów emisji akustycznej do detekcji wyładowań niezupełnych w izolatorach przepustowych
Application possibility estimation of acoustic emission signals for detection of partial discharges in bushing isolators
Autorzy:
Cichoń, A.
Borucki, S.
Subocz, J.
Powiązania:
https://bibliotekanauki.pl/articles/153875.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
izolatory przepustowe
wyładowania niezupełne
metoda emisji akustycznej
diagnostyka elektroenergetyczna
bushing isolator
partial discharges
acoustic emission method
electric power diagnosis
Opis:
W artykule przedstawiono wyniki prac naukowo - badawczych związanych z detekcją wyładowań niezupełnych (WNZ) w izolatorach przepustowych z wykorzystaniem metody emisji akustycznej (EA). Badania przeprowadzono w warunkach laboratoryjnych wykorzystując model izolatora typu GSKTFK, w którym osłonę porcelanową zastąpiono obudową wykonaną z tworzywa sztucznego. Pomiary wykonywano w układach modelujących różne rodzaje uszkodzeń. Sygnały EA rejestrowano za pomocą piezoelektrycznego przetwornika stykowego przymocowanego do zewnętrznej części osłony izolatora. Analizę zarejestrowanych sygnałów przeprowadzono w dziedzinie czasowo - częstotliwościowej z wykorzystaniem krótkoczasowej transformaty Fouriera (STFT). Efektem przeprowadzonych prac było określenie możliwości wykorzystania metody EA do detekcji WNZ powstających na skutek różnych rodzajów defektów w izolacji papierowo - olejowej.
Reliable operation of an electric power system is connected with the necessity of maintenance of its particular elements for theirs good technical state. Important part of the electric power network is the high power transformer, which inherent elements are bushing isolators. Effective detection of PDs in inner part of the paper-oil isolation is one of the main conditions which assure safety operation of bushing isolators. Limited possibility for switching off the electric power devices is a reason for looking for new diagnostic methods enabling on-line measurements execution. Measurements results of AE signals generated in a bushing isolator: with defective inner paper-oil isolation, with presence of air blebs freely moving inside the isolation system, with forced motion of air blebs and with entered natural aging products of cellulose between the particular layers of the insulating system are presented in the paper. Results achieved in the scope of works performed confirmed the application possibility of AE method for technical state diagnosis of paper-oil insulation of bushing isolators in terms of PD appearance. During measurements of AE signals two kinds of PDs have been observed: electrical discharges in the inner part of paper-oil isolation and inside the air blebs. Time-frequency analysis has enabled to assign characteristic frequency bands to the particular PD types. This has created a basis for further works aiming development of research methodic enabling for AE signals measurement on bushing isolators under normal operation condition.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 4, 4; 348-351
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza czasowo-częstotliwościowa sygnałów emisji akustycznej generowanych przez podobciążeniowy przełącznik zaczepów o konstrukcji z osobnym wybierakiem i przełącznikiem mocy
Time-frequency analysis of acoustic emission signals generated by on load tap changer constructed from separated selector and power switch
Autorzy:
Cichoń, A.
Frącz, P.
Lorenc., M.
Powiązania:
https://bibliotekanauki.pl/articles/153883.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
podobciążeniowe przełączniki zaczepów (PPZ)
diagnostyka transformatorów elektroenergetycznych
metoda emisji akustycznej
on load tap changer (OLTC)
electric power transformer diagnosis
acoustic emission method
Opis:
Podobciążeniowe przełączniki zaczepów (PPZ) są jednym z głównych elementów transformatora, który zapewnia możliwość regulacji napięcia w sieci elektroenergetycznej. Ich awarie są częstą przyczyną wyłączeń transformatorów rozdzielczych. W artykule przedstawiono wyniki prac naukowo-badawczych mających na celu scharakteryzowanie sygnałów emisji akustycznej (EA) generowanych przez PPZ o konstrukcji z osobnym wybierakiem i przełącznikiem mocy. Zaletą metody EA jest możliwość wykonywania pomiarów w warunkach normalnej pracy urządzenia. Badania przeprowadzono w warunkach laboratoryjnych. Analizę sygnałów EA przeprowadzono w dziedzinie czasu i czasowo-częstotliwościowej. Ocenę składowych czasowo-częstotliwościowych przeprowadzono z wykorzystaniem krótkoczasowej transformaty Fouriera (STFT) i ciągłej (CWT) transformaty falkowej.
An important part of an electric power transformer is the on load tap changer (OLTC) which enables voltage regulation in the network. Due to high level of failure frequency of these devices, it is necessarily to look for new diagnostic methods which enable their technical state estimation under transformer normal operating conditions. Presently at the Electric Power Institute of the Opole University of Technology there are works in progress aspiring to determine the application possibility of the AE method for OLTC diagnosis. Results of the research works aiming at characterizing the acoustic emission (AE) signals generated by the OLTC constructed from a separated selector and a power switch are presented in the paper. Measurements were taken in a setup with a model of the OLTC type VEL - 110 - 27 from ELIN as the main element. AE signals generated during the whole OLTC joining cycle are presented. Within the signal there were enhanced four characteristic acoustic structures which regard to succeeding stages of the joining process. The AE signals generated by the selector and power switch were analyzed in detail. The analysis of time-frequency components of the signals generated by the OLTC was carried out with the short time Fourier transform (STFT) and con-tinuous wavelet transform (CWT). Based on the comparison of the AE signals generated by the power changer and the selector, two measuring paths endowed with wide band contact transducers were proposed for practical application.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 4, 4; 360-363
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study on Descriptors of Acoustic Emission Signals Generated by Partial Discharges under Laboratory Conditions and in On-Site Electrical Power Transformer
Autorzy:
Kunicki, M.
Cichoń, A.
Borucki, S.
Powiązania:
https://bibliotekanauki.pl/articles/176881.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
acoustic emission
partial discharge
transformer diagnostics
Opis:
An acoustic emission method (AE) is widespread and often applied for partial discharge (PD) diagnostics, mainly due to its ease of application as well as noninvasiveness and relatively high sensitivity. This paper presents comparative analysis of AE signals measurement results archived under laboratory conditions as well as on-site actual AE signals generated by inside PDs in electrical power transformer during its normal service. Three different PD model sources are applied for laboratory research: point to point, multipoint to plate and surface type. A typical measuring set up commonly used for on-site transformer PD diagnostics is provided for the laboratory tasks: piezoelectric joint transducer, preamplifier, amplifier and measuring PC interface. During the on-site research there are three measuring tracks applied simultaneously. Time domain, time-frequency domain and statistical tools are used for registered AE signals analysis. A number of descriptors are proposed as a result of the analysis. In the paper, attempt of AE signals descriptors, archived under laboratory condition application possibilities for on-site PD diagnostics of power transformers during normal service is made.
Źródło:
Archives of Acoustics; 2016, 41, 2; 265-276
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Technical Possibilities of Reducing the Sound Pressure Level Emitted into the Environment by a Power Transformer
Autorzy:
Borucki, S.
Boczar, T.
Cichoń, A.
Powiązania:
https://bibliotekanauki.pl/articles/177473.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power transformer
corrected sound pressure level
noise
modernization
Opis:
The subject presented in this paper refers to measurements and assessment of the corrected sound pressure level values (noise) occurring around a medium-power transformer. The paper presents the values of noise accompanying the operation of the power object before and after its modernization, which consisted in repeated core pressing and replacement of the cooling system. The main aim of the research work was the assessment of the influence of the repair work on the noise level emitted into the environment.
Źródło:
Archives of Acoustics; 2011, 36, 1; 49-56
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza porównawcza wyników badań w zakresie oceny stopnia zużycia styków PPZ metodą akustyczną i oscylograficzną
Comparison analysis of research results on determining level of OLTC contact deterioration using acoustic and oscillographic methods of diagnostics
Autorzy:
Cichoń, A.
Bergber, P.
Borucki, S.
Powiązania:
https://bibliotekanauki.pl/articles/152504.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
podobciążeniowe przełączniki zaczepów (PPZ)
diagnostyka transformatorów elektroenergetycznych
metoda emisji akustycznej
on load tap changer (OLTC)
electric power transformer diagnostics
acoustic emission method
Opis:
W artykule przedstawiono wyniki prac naukowo – badawczych związanych z diagnostyką podobciążeniowych przełączników zaczepów (PPZ). Badania wykonano w warunkach laboratoryjnych z wykorzystaniem modelu fizycznego PPZ typu VEL 110, umieszczonego w kadzi wypełnionej olejem izolacyjnym. Sygnały emisji akustycznej rejestrowano szerokopasmowym przetwornikiem piezoelektrycznym przymocowanym do zewnętrznej części kadzi. Zarejestrowane sygnały poddano analizie w dziedzinie czasowej. Wyniki pomiarów metodą oscylograficzną przedstawiono w postaci przebiegów prądowych i wyznaczając wartości czasów własnych. Na podstawie uzyskanych wyników przeprowadzono analizę porównawczą wyników uzyskanych za pomocą obu metod pomiarowych.
This paper presents results of scientific research on diagnostic methods for on load tap changers (OLTC). Measurements were made in laboratory conditions with use of a physical model of the VEL 110 OLTC placed in a tank filled with insulating oil. Acoustic emission signals were recorded with use of a R15α wide band piezoelectric transducer which was fixed to the tank of the model. These signals were analyzed in the time domain, which resulted in calculation of the signal envelope and its characteristic times. The results of the oscillographic measurements are presented in the form of current diagrams and the calculated OLTC characteristic times. Basing on the obtained results of the oscillographic and acoustic measurements, a comparison analysis of both diagnostic methods was performed. The research data presented in this paper proves that detection of OLTC contact deterioration is possible by using both oscillographic and acoustic methods of diagnostics.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 2, 2; 152-155
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie uczenia nadzorowanego do klasyfikacji defektów PPZ na podstawie sygnałów EA
Application of supervised learning for classification of OLTC defects on the basis of AE signals
Autorzy:
Wotzka, D.
Cichoń, A.
Manowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/376716.pdf
Data publikacji:
2018
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
analiza sygnałów EA
podobciążeniowe przełączniki zaczepów
PPZ
klasyfikacja uszkodzeń PPZ
uczenie nadzorowane
Opis:
Tematyka artykułu dotyczy rozpoznawania defektów podobciążeniowych przełączników zaczepów (PPZ) z wykorzystaniem uczenia nadzorowanego. PPZ to specjalistyczne urządzenie będące częścią transformatora elektroenergetycznego, które pozwala na skokową zmianę przekładni a tym samym napięcia na zaciskach tego transformatora. Jako metodę diagnostyczną zastosowano metodę emisji akustycznej (EA), której zaletą jest możliwość stosowania podczas normalnej pracy transformatora bez konieczności jego wyłączania. Sygnały EA pozyskane z badań laboratoryjnych, w których symulowano cztery rodzaje defektów - typowych uszkodzeń PPZ, poddano wstępnej analizie z wykorzystaniem filtrów cyfrowych i transformaty Hilberta, a następnie poddano procesowi klasyfikacji. W artykule zawarto przykładowe przebiegi czasowe sygnałów EA oraz wyniki wstępnych badań dotyczących klasyfikacji defektów PPZ z wykorzystaniem siedmiu metod wraz z oceną ich skuteczności.
The subject of the article concerns recognition of defects of on load tap changers (OLTC) with the use of supervised learning. OLTC is a specialized device that is part of a power transformer, which allows for a step change of the gear and thus the voltage at the terminals of this transformer. The acoustic emission (AE) method was applied as diagnostic method. The advantage of this method lies in the possibility of its application during normal operation of the device without having to turn it off. EA signals were obtained from laboratory tests in which four types of defects - typical OLTC damages, were simulated. The gathered signals were pre-analyzed using digital filters and Hilbert transforms, and then subjected to the classification process. The article contains examples of EA signal waveforms and the results of preliminary research on the classification of OLTC defects with the use of seven methods together with an assessment of their effectiveness.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2018, 93; 335-344
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling of Acoustic Emission Signals Generated in On Load Tap Changer
Autorzy:
Cichoń, A.
Borucki, S.
Wotzka, D.
Powiązania:
https://bibliotekanauki.pl/articles/1199209.pdf
Data publikacji:
2014-06
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.40.-r
43.40.Vn
43.58.Wc
Opis:
The paper deals with mathematical modeling of acoustic emission signals which are generated in on load tap changers. In power engineering area acoustic emission method is commonly used for diagnosis purposes. Authors in their research works apply it for detection of defects occurring in on load tap changers, which are important elements of power transformers. The acoustic emission method is based on measurements performed by use of wideband piezoelectric transducers that are mounted on transformer tank surface. The registered signal is then analyzed in the time, frequency, and time-frequency domains or is evaluated with computer expert systems for diagnosis purposes. Depending on indicators device technical condition can be determined. The contribution given by the authors in this paper is proposal of a mathematical model, which describes envelope of the measured acoustic emission signal.
Źródło:
Acta Physica Polonica A; 2014, 125, 6; 1396-1399
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostics of the Core Mechanical Construction Based on Vibroacoustic Measurements and Distribution of Temperature Field in Transformer Magnetic Circuit
Autorzy:
Borucki, S.
Cichon, A.
Boczar, T.
Powiązania:
https://bibliotekanauki.pl/articles/1401874.pdf
Data publikacji:
2015-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.40.-r
43.40.Vn
43.58.Wc
Opis:
Subject matter of this article concerns the results of research works on the development and use of the vibroacoustic method to evaluate technical state of transformer cores. The article presents obtained measurement results of transformer mechanical vibration for two cases of its operation: with twisted and loosened core. In order to demonstrate negative effects of operating a transformer with a loosened core, this publication presents thermographic images showing temperature distribution on its magnetic core. The article characterises the examined transformer, employed measurement system and methodology of the completed experiment. The vibroacoustic and thermographic measurements were carried out during idle work of the transformer. Core vibration was registered for three measurement axes: 0X, 0Y and 0Z. Completed tests have proven that loosened screws pressing the core cause evident increase in the value of magnetic core vibration acceleration. At the same time, the temperature rises by more than 25%.
Źródło:
Acta Physica Polonica A; 2015, 128, 3; 306-309
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selecting Mother Wavelet for Wavelet Analysis of On-Load Tap Changer Acoustic Emission
Autorzy:
Cichoń, A.
Berger, P.
Wotzka, D.
Powiązania:
https://bibliotekanauki.pl/articles/1401875.pdf
Data publikacji:
2015-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.40.-r
43.58.Wc
Opis:
Wavelet transformation is one of the most popular tools for acoustic signal analysis. It provides good resolution both in time and frequency domains as well as wide choice of mother wavelets - this makes wavelet transformation a choice when flexible approach is required. However, selecting parameters of analysis can be difficult, especially regarding mother wavelet as different mother wavelets have various properties regarding number of vanishing moments and symmetry. This paper presents studies to determine the possibility of on-load tap changer wear detection by applying wavelet transformation. In research, different mother wavelets were selected and their usefulness was examined. Signals to be analyzed were obtained during on-load tap changer operation in different mechanical conditions - simulating devices wear in service. All measurements were performed on model very similar to real industrial on-load tap changer. Tests were conducted in controlled laboratory environment, reducing most of the possible disruptions.
Źródło:
Acta Physica Polonica A; 2015, 128, 3; 310-314
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selecting Sensor for On Load Tap Changer Contacts Degree of Wear Diagnostics
Autorzy:
Cichoń, A.
Borucki, S.
Berger, P.
Powiązania:
https://bibliotekanauki.pl/articles/1399337.pdf
Data publikacji:
2013-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.40.-r
43.40.Vn
43.58.Wc
Opis:
Results of scientific research works considering selection of measuring transducer applied for registration of acoustic emission signals generated by on load tap changers are presented in the paper. During the coupling process acoustic emission signals are generated by: the mechanical setup of tap changer, contacts operation, and other phenomena. For most on load tap changers types, the working medium is insulation oil in which the acoustic wave being formed propagates to the steal tank. There exists a possibility to register acoustic emission signals with a piezoelectric transducer attached to the outer tank surface or with a hydrophone immersed in the oil. Acoustic emission signal obtained in such manner contains information which describes operation of the power tap changer and the selector. A comparative analysis of acoustic emission signals generated by on load tap changers working under laboratory conditions, with applied measuring transducers with different transmittances, is presented in the paper. The comparative analysis was performed in order to determine their suitability for on load tap changers technical condition diagnosis. Based on the results achieved, one transducer which allows the registration of acoustic events generated during on load tap changers operation was selected.
Źródło:
Acta Physica Polonica A; 2013, 124, 3; 395-398
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Characteristic of Acoustic Signals Generated by Operation of On Load Tap Changers
Autorzy:
Cichon, A.
Fracz, P.
Zmarzly, D.
Powiązania:
https://bibliotekanauki.pl/articles/1493036.pdf
Data publikacji:
2011-10
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
52.80.-s
43.28.Js
Opis:
Possibilities of application of the acoustic method for the on load tab changers diagnosis has been presented in the paper. The analysis of measurement results gathered during research works performed under laboratory conditions has been presented in detail. The registered acoustic signals have been analyzed in time and time-frequency domains. The time domain analysis has been performed by presentation of time runs and their envelopes determined by use of the Hilbert transform. Evaluation of the time-frequency components has been performed by use of the short-time Fourier transform, the discrete and the continuous wavelet transforms.
Źródło:
Acta Physica Polonica A; 2011, 120, 4; 585-588
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Interference Signals Generated by Vibroacoustic Vibrations of Transformer Cores
Autorzy:
Boczar, T.
Borucki, S.
Cichoń, A.
Powiązania:
https://bibliotekanauki.pl/articles/1199078.pdf
Data publikacji:
2014-06
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
79.60.Bm
42.79.Pw
52.80.Hc
Opis:
The article deals with the subject matter referring to the interference that may accompany measurements of vibroacoustic signals, generated by electric power transformers, taken by using the acoustic emission method under industrial conditions. Paper concerns measurement and analysis of internal, acoustic type disturbances, including the magnetostrictive vibrations of plate sets within the transformer core, caused by changes in the magnetic flux. Paper presents measurement results of acoustic interfering signals and results of analyses made in the frequency and time-frequency domains. Power spectral density, MUSIC pseudospectra, two- and three-dimensional short time Fourier transform spectrograms, continuous wavelet transform scalograms, discrete wavelet transform, and quantities of energy transferred are included in the paper.
Źródło:
Acta Physica Polonica A; 2014, 125, 6; 1355-1359
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka stanu technicznego obwodu magnetycznego transformatorów energetycznych z wykorzystaniem zmodyfikowanej metody wibroakustycznej
Diagnostics of technical condition of power transformer magnetic circuit with use of a modified vibroacoustic method
Autorzy:
Borucki, S.
Cichoń, A.
Skubis, J.
Powiązania:
https://bibliotekanauki.pl/articles/153431.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
transformator elektroenergetyczny
drgania mechaniczne
metoda wibroakustyczna
rdzeń
power transformer
mechanical vibrations
vibroacoustic method
core
Opis:
W publikacji scharakteryzowano zaproponowaną metodykę, tzw. zmodyfikowaną metodę wibroakustyczną, oraz przedstawiono rezultaty badań uzyskane na dwóch transformatorach, jednostce typu TR 16000/110 i TORb 25000/110. Ocenę efektywności opracowanej metodyki pomiarowo – diagnostycznej przeprowadzono poprzez korelację wyników analizy czasowo – częstotliwościowej zarejestrowanych wibracji z rezultatami badań chromatograficznych (DGA) oleju elektroizolacyjnego pobranego z kadzi monitorowanych urządzeń. Analizę zarejestrowanych drgań wykonano z wykorzystaniem przekształceń STFT, CWT i DWT.
The subject of the paper concerns evaluation of the technical condition of the power transformer magnetic circuit by measuring and analyzing vibrations recorded during switching on the transformer. This paper presents the results of technical verification of the noninvasive method used for diagnostics of transformer cores. The research on application of this method has been performed at the Institute of Power Engineering of the Opole University of Technology for several years. The paper characterizes the proposed methodology, the so-called modified vibroacoustic method, and presents the results obtained on two tested transformers, type TR 16000/110 and TORb 25000/110. Evaluation of the effectiveness of the developed methodology of diagnostic measurements was performed by correlation analysis of the time-frequency vibrations recorded with the results of chromatographic studies (DGA) of oil taken from the transformer tank. The recorded vibrations were analyzed using the transformation STFT (Short Time Fourier Transform), CWT (Continuous Wavelet Transform) and DWT (Discrete Wavelet Transform). On the basis of the results given in this paper as well as the currently conducted research work, it was found that there is a real possibility of using the developed method for noninvasive assessment of technical condition of mechanical construction of power transformer cores in operating conditions.
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 2, 2; 102-105
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka transformatorów energetycznych z wykorzystaniem metody wibroakustycznej
Diagnostics of Power Transformers Using the Vibroacoustic Method
Autorzy:
Borucki, S.
Cichoń, A.
Boczar, T.
Powiązania:
https://bibliotekanauki.pl/articles/155761.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
transformator energetyczny
drgania
rdzeń
metoda wibroakustyczna
diagnostyka
power transformer
vibration
core
vibroacoustic method
diagnostic
Opis:
Tematyka artykułu dotyczy diagnostyki rdzeni transformatorów elektro-energetycznych dużej mocy z wykorzystaniem pomiarów drgań wibroaku-stycznych. W artykule, na podstawie analizy drgań mechanicznych kadzi, dokonano oceny stanu technicznego czterech transformatorów blokowych typu TFBb 240000/400. Scharakteryzowano układ pomiarowy, który został wykorzystany podczas rejestracji sygnałów pochodzących od przenoszonych przez kadź drgań rdzenia poszczególnych jednostek. W oparciu o przyjęte w artykule wartości kryterialne podjęto próbę oceny stanu technicznego diagnozowanych urządzeń elektroenergetycznych.
During its operation a power transformer is subjected to the influence of numerous unfavourable factors which shorten its operation time and can cause unexpected disastrous failures. As far as the active part of a transformer is considered, magnetostrictic vibrations and cellulose depolymerization are the most harmful factors causing the loss of mechanical strength. Their influence results in the gradual loosening of the pressing and clamping of the core and transformer windings, which leads to the weakening of the active part mechanical construction (Fig. 1). In the electric power sector there are a few methods for detection of damages in power transformers. One of them is the vibroacoustic method which consists in measurement and analysis of vibrations of the object under study. Its application to high-power transformer diagnostics enables, first of all, assessing the technical condition of the core. Additionally, combining this method with other diagnostic methods can provide information not only on the core technical condition but also on the solid insulation properties of the device being tested [5 - 6]. In the paper the technical assessment of the condition of four unit transformers of type TFBb 240000/400 is performed basing on the analysis of mechanical vibrations of the tub. The basic technical parameters of the transformers are listed in Table 1. The measuring system used for recording the signals coming from the core vibrations of the particular units and transferred by the tub is described. Based on the criterion values [among others 6 - 8] an attempt to assess the technical condition of the electric power appliances diagnosed is made. The investigations and analyses carried out confirm that the measurement results of vibrations of the particular units have not revealed any damage to their cores or other defects of mechanical character.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 1, 1; 19-22
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Praktyczny przykład skutecznej detekcji i lokalizacji wyładowań niezupełnych metodą emisji akustycznej w transformatorze elektroenergetycznym
Practical example of effective detection and location of partial discharges by the acoustic emission method in an electric power transformer
Autorzy:
Skubis, J.
Cichoń, A.
Borucki, S.
Powiązania:
https://bibliotekanauki.pl/articles/155763.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
wyładowania niezupełne
metoda emisji akustycznej
diagnostyka
transformator elektroenergetyczny
partial discharges
acoustic emission method
diagnostics
power transformer
Opis:
W artykule przedstawiono przykład diagnostyki transformatora elektro-energetycznego pod kątem oceny stanu technicznego papierowo - olejowego układu izolacyjnego zagrożonego występowaniem wyładowań niezupełnych (WNZ). Badania przeprowadzono podczas normalnej pracy jednostki transformatorowej, rejestrując w 36 punktach na powierzchni kadzi sygnały emisji akustycznej (EA) pochodzącej od zjawisk fizycznych występujących wewnątrz transformatora. Zarejestrowane sygnały poddano analizie w dziedzinie czasowej, częstotliwościowej i czasowo - częstotliwościowej. Wynikiem badań była detekcja i lokalizacja miejsca występowania wyładowań elektrycznych oraz wskazanie prawdopodobnej przyczyny i miejsca ich powstawania.
Three measurement methods: gas chromatography method (DGA), electrical method and AE method are used in the assessment of the technical condition of paper-oil insulation of high-power transformers exposed to the occurrence of partial discharges (PDs). The acoustic method of PD detection is used as a supplementary one to the two others, mainly the gas chromatography method which does not make it possible to locate the place of the insulation system defect appearance. The basic advantage of the AE method, compared with the electrical one, is the possibility of its application during regular operation of power appliances [2, 3]. The paper presents the measurement results of the AE signals accompanying regular operation of a power transformer of 270 MVA. In order to assess the intensity of the AE signals measured on the object under study, coming from physical phenomena taking place inside a tub, three analyses were performed: in the time, frequency and time-frequency domains. Registration of the AE signals, the distributions of which is shown in Fig. 2, was carried out at 36 measurement points. An exemplary waveform of the AE signals registered is shown in Fig. 3, while the results of the analysis in the time domain are listed in Tables 1 and 2. In order to assess the waveforms registered more accurately, the analysis in the frequency domain was carried out and amplitude spectra were determined, an example of which is presented in Fig. 4. The time-frequency analysis was performed by using a short-time Fourier transform (STFT) determining two-dimensional spectrograms of the power density spectrum (Fig. 5). The assessment of the technical condition of the transformer under study made it possible to detect and locate areas in which PDs occurred. Damage of magnetic screens is a probable cause of their occurrence.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 1, 1; 30-33
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of the Acoustic Emission Method for Diagnosis of On-Load Tap Changer
Autorzy:
Majchrzak, H.
Cichoń, A.
Borucki, S.
Powiązania:
https://bibliotekanauki.pl/articles/176624.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
acoustic emission
partial discharge
transformer diagnostics
Opis:
This paper provides an example of the application of the acoustic emission (AE) method for the diagnosis of technical conditions of a three-phase on-load tap-changer (OLTC) GIII type. The measurements were performed for an amount of 10 items of OLTCs, installed in power transformers with a capacity of 250 MVA. The study was conducted in two different OLTC operating conditions during the tapping process: under load and free running conditions. The analysis of the measurement results was made in both time domain and time-frequency domain. The description of the AE signals generated by the OLTC in the time domain was performed using the analysis of waveforms and determined characteristic times. Within the time-frequency domain the measured signals were described by short-time Fourier transform spectrograms.
Źródło:
Archives of Acoustics; 2017, 42, 1; 29-35
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnosis of the Non-Concurrent Operation of the On-Load Tap Changer Contacts by the Acoustic Emission Method
Autorzy:
Cichoń, A.
Borucki, S.
Boczar, T.
Powiązania:
https://bibliotekanauki.pl/articles/177044.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power transformer
on-load tap changers
acoustic emission method
Opis:
On-load tap changers (OLTC) are some of the main transformer elements that make voltage adjustment in a power network possible. Their failures often cause shutdowns of distribution transformers. The paper presents research work aimed at the assessment of the technical condition of OLTCs by the acoustic emission method (EA). This method makes the OLTC diagnosis possible without the need of disconnecting the transformer from the system. The measurements were taken in laboratory conditions. The influence on the operation non-concurrence of the power tap changer contacts on the AE registered signals has been investigated. The signals registered were subjected to analyses in the time and time-frequency domains. The result analysis in the time domain was carried out using the Hilbert transform and calculating characteristic times for the particular runs. A short-time Fourier transform was used for the assessment of results in the time-frequency do- main.
Źródło:
Archives of Acoustics; 2011, 36, 4; 823-830
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modeling and Experimental Verification of Ultrasound Transmission in Electro Insulation Oil
Autorzy:
Wotzka, D.
Cichoń, A.
Boczar, T.
Powiązania:
https://bibliotekanauki.pl/articles/177158.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ultrasound transmission
numerical simulations
electro-insulation oil
Opis:
A verification study of ultrasound transmission numerical simulation results with experiment results is presented in this paper. The work considers a model of a transformer tank which is filled with electro insulating oil. In the experiment, performed under laboratory conditions, an ultrasound wave is generated by a piezoelectric transducer that is fixed in the centre of the tank and measured by another transducer mounted inside the tank at three distances: 10, 20 and 30 cm from the sound source. The transducer is able to measure and generate acoustic waves in the ultrasound frequency band up to 1 MHz. The simulation considers numerical calculation of acoustic pressure distribution inside the tank in which acoustic source emits waves with frequency equal to 100 kHz. Verification analysis has confirmed consistency of the numerically calculated values with the measurement results.
Źródło:
Archives of Acoustics; 2012, 37, 1; 19-22
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the Technical Condition of the Active Part of the High Power Transformer Based on Measurements and Analysis of Vibroacoustic Signals
Autorzy:
Borucki, S.
Cichoń, A.
Majchrzak, H.
Zmarzły, D.
Powiązania:
https://bibliotekanauki.pl/articles/176397.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
vibration
vibroacoustic method
core
power transformer
transformer diagnostics
Opis:
This article presents the results of research connected with the development and industrial use of vibroacoustic methods for the evaluation of the technical condition of the active part of transformers. The article presents the results of the analysis of vibrations generated by the high power transformer in which a defect was found on the basis of tests of oil carried out using the chromatography tests. In order to confirm the damage of the active part of this transformer, vibroacoustic measurements were performed in three states of its operation. The measurement using the classical vibroacoustic method included the registration of vibrations at the idle speed and during the load operation of the transformer. The original diagnostic method, so-called the modified vibroacoustic method, was also used during the measurement. The analysis of signals recorded using the classical vibroacoustic method was carried out in the frequency domain by indicating the amplitude of even harmonic vibrations. However, the analysis of signals measured during the commissioning of the transformer was conducted in the time-frequency domain using the short-time Fourier transform (STFT), continuous wavelet transform (CWT), and discrete wavelet transform (DWT). On the basis of the analysis of the results obtained it was stated that the increased level of vibrations of this transformer is a consequence of the loss of rigidity of the mechanical structure of its core.
Źródło:
Archives of Acoustics; 2017, 42, 2; 313-320
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Repeatability Estimation for Vibration Measurement Results of Power Transformer Core
Autorzy:
Borucki, S.
Cichon, A.
Skubis, J.
Boczar, T.
Powiązania:
https://bibliotekanauki.pl/articles/1198972.pdf
Data publikacji:
2014-06
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.40.-r
43.40.Vn
43.58.Wc
Opis:
The subject matter of this paper refers to the diagnostics of a transformer core, based on measurements and analysis of vibroacoustic signals registered during their normal operation. The paper presents results of the research aimed to evaluate the repeatability of vibration measurements for power transformer core. Recording of vibroacoustic signals was performed under laboratory conditions on dry-insulated transformers. The study concerned evaluation of changes in vibroacoustic indicators of the transformer core during operation with a turned and loosened core. Conclusions from the measurement results were drawn on the basis of the parametric test of significance derived from the variance analysis for many means of single classification basing on the Fisher-Snedecor F-distribution.
Źródło:
Acta Physica Polonica A; 2014, 125, 6; 1299-1302
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Solving a Set of Spherical Equations for Localization of Partial Discharges by Acoustic Emission Method
Autorzy:
Boczar, T.
Witkowski, P.
Borucki, S.
Cichoń, A.
Powiązania:
https://bibliotekanauki.pl/articles/1401873.pdf
Data publikacji:
2015-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.40.-r
43.40.Vn
43.58.Wc
Opis:
This article deals with the subject matter of improvement of the acoustic emission methods used for location of partial discharges, which may occur inside power transformer insulation systems. Analytical solutions of spherical equations for location of partial discharge generation using the acoustic method were shown in detail. Presented in the article method of solving the assumed equations is based on the analytical method and matrix notation. Theoretical considerations and later the measurement-based verification refer to the use of the triangulation method for location of the occurrence of partial discharges. The results of the scientific and research works that have been presented in this article are the next stage of research aimed at development of on-line diagnosis system for insulation systems of electrical equipment, allowing for detection, measurement and identification of forms and locations of partial discharges using the acoustic emission method.
Źródło:
Acta Physica Polonica A; 2015, 128, 3; 299-305
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Wavelet Analysis of the Vibroacoustic Signal Measurement in a Transient State Operation of Power Transformer
Autorzy:
Borucki, S.
Cichon, A.
Boczar, T.
Zmarzly, D.
Powiązania:
https://bibliotekanauki.pl/articles/1417934.pdf
Data publikacji:
2012-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.40.-r
43.40.Vn
43.58.Wc
Opis:
The article presents the results of attempts made to develop a non-invasive diagnostic method of a technical state of a transformer's core based on an analysis of mechanical vibrations registered during the start-up of the transformer analyzed. The paper presents a characteristic of the transformer under study, the measuring systems applied and the method developed for assessing the degree of the core loosening. The original results presented in the paper have been obtained under laboratory conditions during tests conducted on an oil transformer of 200 kVA. The analysis of recorded virboacoustic signals was performed by means of discrete wavelet transform for three different operating cases: the transformer with no core defect, the transformer with loose screws of the magnetic circuit of the upper yoke, and the transformer with completely loosen screws of the beam of the upper yoke and the lower core. The signals have been recorded on two perpendicular measuring axes: 0X and 0Y and their measured values were subject to the wavelet analysis.
Źródło:
Acta Physica Polonica A; 2012, 122, 5; 800-803
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Characteristics of Acoustic Emission Signals Generated by the Contacts of the Selector
Autorzy:
Cichoń, A.
Borucki, S.
Wotzka, D.
Szmajda, M.
Powiązania:
https://bibliotekanauki.pl/articles/1417945.pdf
Data publikacji:
2012-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
52.80.-s
43.28.Js
Opis:
An important part of electric power transformer is the on load tap changer which enables for voltage regulation in the network. Due to high level of failure frequency of these devices it is necessary to look for new diagnostic methods which enable for theirs technical state estimation under transformer normal operating condition. Presently at the Electric Power Institute at Opole University of Technology there are works in progress aspiring to determine the application possibility of the acoustic emission method for on load tap changer diagnosis. Results of scientifically-research works aiming to characterize the acoustic emission signals generated by a separated selector are presented in the paper. Measurements have been performed in a setup with a model of on load tap changer type VEL-110-27 from ELIN. Acoustic emission signals generated by the selector have been analyzed in detail. Analysis of the time-frequency components of signals generated by on load tap changer has been carried out with the short time Fourier transform and continuous wavelet transform. Based on the comparison outcome of acoustic emission signals generated by the power changer and by the selector two measuring paths endowed with wide band contact transducers have been proposed for the practical application.
Źródło:
Acta Physica Polonica A; 2012, 122, 5; 804-807
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Acoustic Signals Interfering Diagnostic Measurements of Electric Power Transformer Tap Changers
Autorzy:
Boczar, T.
Cichoń, A.
Borucki, S.
Szczyrba, T.
Powiązania:
https://bibliotekanauki.pl/articles/1399334.pdf
Data publikacji:
2013-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.58.-e
43.60.-c
43.60.Bf
Opis:
Subject matter of this paper applies to improvement of acoustic emission method used in the diagnosis of on load tap changers of high power transformers. During measurement of acoustic emission signals generated by damages or defects, which can appear in insulation system and in the power transformer tap changers, various forms of noise signals may occur. Interferences occurring during measurements under laboratory and under industrial conditions can be generated either by sources placed inside the studied electric power device or they can be emitted in their immediate vicinity. Sources of interfering signals are physical phenomena of a mechanical, electrical or acoustical nature. Interferences appearing during measurement of acoustic emission pulses generated by electrical discharges and other types of defects that overlap the measured waveforms may result in their distortion. As part of the research conducted, the results of which are presented in this paper, following was subjected under consideration: measurements of acoustic noise signals generated by partial surface discharges occurring on support and bushing insulators were performed.
Źródło:
Acta Physica Polonica A; 2013, 124, 3; 387-390
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Critical Evaluation of the Vibroacoustic Criteria Used in Poland to Diagnose of Power Transformer Cores
Autorzy:
Borucki, S.
Cichon, A.
Boczar, T.
Zmarzly, D.
Powiązania:
https://bibliotekanauki.pl/articles/1399335.pdf
Data publikacji:
2013-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.40.-r
43.40.Vn
43.58.Wc
Opis:
The subject matter of this article concerns the diagnostic test results of transformer cores by measuring and analysing vibroacoustic signals registered during their normal operation. The main objective of this research study conducted by the authors, the results of which are published in this paper, is a critical analysis of vibroacoustic criteria, which are adopted in Poland nowadays, and based on which, the assessment of the core technical condition is performed. This article presents exemplary results that were obtained on two twin units of type TET 8509 with a power of 40 MVA. The paper specifies diagnosed structures, the measurement system applied, and the currently used methodology to assess the degree of core loosening. To determine the efficacy and assessment accuracy of the applied vibroacoustic criteria, correlation between mechanical vibration measurements of the tested transformer tanks and results obtained by gas chromatography was performed.
Źródło:
Acta Physica Polonica A; 2013, 124, 3; 391-394
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Analysis of Mechanical Vibrations and Acoustic Pressure Level οf a Transformer Model
Autorzy:
Boczar, T.
Borucki, S.
Cichon, A.
Lorenc, M.
Powiązania:
https://bibliotekanauki.pl/articles/1811534.pdf
Data publikacji:
2008-12
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
43.58.Wc
43.58.Fm
Opis:
The paper presents the results of vibroacoustic investigations and the measurements of the acoustic pressure level (noise) of a transformer model. The measurements were taken at a full transformer load in two operation conditions: at a producer packeted core and at unpacketed core. Unpacketing consisted in loosing the screws pressing the particular core plates. Mechanical vibrations were registered and the acoustic pressure level was measured. The vibroacoustic analysis results are presented in the form of frequency spectra and the results of the acoustic analysis of the transformer under study are shown by determining corrected values of the acoustic pressure level and by a frequency analysis.
Źródło:
Acta Physica Polonica A; 2008, 114, 6A; A-21-A-26
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Koncepcja redukcji hałasu chłodnic wentylatorowych
The concept of noise reduction of cooling fans
Autorzy:
Zając, J.
Włodarz, R.
Borucki, S.
Cichoń, A.
Powiązania:
https://bibliotekanauki.pl/articles/153871.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
chłodnica wentylatorowa
hałas
skorygowany poziom ciśnienia akustycznego
transformator elektroenergetyczny
ograniczanie hałasu
cooling fan
noise
corrected sound pressure level
power transformer
noise reduction
Opis:
Tematyka artykułu dotyczy prowadzonych przez firmę Energo-Silesia i pracowników Politechniki Opolskiej badań i prac koncepcyjnych zmierzających do zaprojektowania oraz skonstruowania nowoczesnej, niskoszumnej chłodnicy wentylatorowej. Celem omawianych w artykule badań jest próba optymalizacji aktualnie stosowanych w przemyśle konstrukcji olejowo-powietrznych układów chłodzących transformatorów pod kątem możliwość redukcji generowanego przez nie hałasu. W pracy zaproponowano trzy sposoby redukcji poziomu ciśnienia akustycznego poprzez: zmianę kształtu dyfuzora wylotu powietrza, zastosowanie cichobieżnych wentylatorów i regulacji prędkości obrotowej wentylatorów.
During the operation a power transformer produces noise whose main sources are, among others, cooling fans and magnetostrictive vibrations of the core [1, 2]. A power transformer installed in an industrial object should be chosen in such a way that the noise arising during its normal operation does not exceed the limit values set out in particular in environmental standards [3, 4]. The paper presents the scope of research and conceptual work conducted by the staff of the Energo-Silesia company and Opole University of Technology. It is aimed at design and construction of a modern, low-noise cooling fan. The main objective of the work is an attempt to optimise the methods used in construction industry of oil-air cooling systems of power transformers as well as to assess constraints generated by the environmental sound pressure level. There are proposed three potential areas for possible reduction of noise produced in coolers. The first is optimisation of a structure housing the column and use of steering cooler air stream (Fig. 1b). The second option is to use a specialised fan blade design, and consequently a reduced power level (Figs. 2 and 4). The last and most widely described in publications is the concept of intelligent speed control of fan motors (Figs. 8 and 9).
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 4, 4; 338-342
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Planowanie eksploatacji transformatorów z zastosowaniem systemu TrafoGrade
Planning of transformer operation with use of the TrafoGrade system
Autorzy:
Szrot, M.
Płowucha, J.
Subocz, J.
Borucki, S.
Cichoń, A.
Powiązania:
https://bibliotekanauki.pl/articles/156483.pdf
Data publikacji:
2008
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
stan techniczny
ocena
eksploatacja transformatorów
planowanie
system TrafoGrade
assessment
technical condition
operation planning
transformer
TrafoGrade system
Opis:
W artykule przedstawiono system oceny stanu technicznego transformatorów TrafoGrade, który opracowano w firmie Energo-Complex i wdrożono w praktyce. Omówiono podstawy tworzenia części technicznej oceny transformatorów, która składa się z trzech etapów ocen grupowych oraz etapu końcowej oceny transformatora. Przedstawiono zasady określania znaczenia transformatorów w sieci elektroenergetycznej. Podano przykłady zastosowania systemu TrafoGrade w praktyce eksploatacyjnej oraz wnioski wypływające z jego użycia dla określonej populacji transformatorów.
The paper presents the TrafoGrade system for assessment of transformer technical condition, designed by Energo-Complex and implemented into operation. The basics for preparing the technical part of assessment consisting of three stages of group grades and the final stage of transformer assessment are given. There are also described the principles of determining the transformer importance in the system. Some examples of application of TrafoGrade to operation conditions and the conclusions resulting from its use for a determined population of transformers are presented.
Źródło:
Pomiary Automatyka Kontrola; 2008, R. 54, nr 11, 11; 780-782
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Results of Optical Signals Analyses Emitted by Electrical Discharges Recorded with UV Camera
Autorzy:
Frącz, P.
Boczar, T.
Borucki, S.
Cichoń, A.
Zmarzły, D.
Powiązania:
https://bibliotekanauki.pl/articles/1417952.pdf
Data publikacji:
2012-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
79.60.Bm
42.79.Pw
52.80.Hc
Opis:
In the article results of measurements and analyses of the optical signals emitted by electrical surface partial discharges occurring on bushing and post insulators, recorded with UV camera during tests under laboratory conditions are presented. The carried out research was to determine the effect of the distance between the insulator's electrodes and the voltage value on the number of partial discharges.
Źródło:
Acta Physica Polonica A; 2012, 122, 5; 814-817
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ekonomiczne aspekty eksploatacji transformatorów z wykorzystaniem systemu TrafoGrade
Economic aspects of transformer operation with TrafoGrade system application
Autorzy:
Szrot, M.
Płowucha, J.
Subocz, J.
Borucki, S.
Cichoń, A.
Powiązania:
https://bibliotekanauki.pl/articles/155786.pdf
Data publikacji:
2009
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
ocena stanu technicznego
eksploatacja transformatorów
planowanie
system TrafoGrade
technical condition assessment
operation planning
transformer
TrafoGrade system
Opis:
W artykule przedstawiono metodykę i przykładowe wyniki diagnostyki transformatorów elektroenergetycznych prowadzonej z wykorzystaniem systemu TrafoGrade, który opracowano i wdrożono w firmie Energo - Complex. Scharakteryzowano poszczególne części składowe systemu takie jak ocena stanu technicznego, ocena znaczenia transformatora w systemie elektroenergetycznym oraz analiza ekonomicznych perspektyw eksploatacji. Przedstawiono również koncepcję stworzenia systemu komputerowego do zarządzania populacją transformatorów. Podano przykładowe analizy wykonane w oparciu o otrzymane wyniki pomiarowe z 45 transformatorów rozdzielczych zainstalowanych w jednej ze spółek dystrybucyjnych działających na terenie Polski.
Power transformers are significant part of assets owned by entities distributing and transferring electric energy. In Poland, there are several thousands of medium and high power transformers operated, while over 50% of them is older than 30 years, what means they have already exceeded their planned lifetime. At present in Europe there are not sufficient production and financial means allowing to exchange most of transformers population in the close future. The only possibility is maximally to prolong the operation of already installed old units [1]. To help fulfilling this task Energo-Complex Ltd. has elaborated complex system of transformers management, named TrafoGrade, which is based on the point scale assessment of transformer's technical condition, its importance in the power grid and linking technical aspects of diagnostics with economic-financial factors to conduct decision process optimizing in the range of routine exploitation, repairs planning and investment policy [2]. The assessment of technical ondition with TrafoGrade system is based on analysis of 15 parameters obtained from diagnostic measurements, divided into three groups (Fig. 2). The paper presents examples of technical condition assessment (Fig. 4, 5, 6) and describes operational possibilities for 45 distribution transformers installed in one of distribution companies operating in Poland. For the operation planning and rationalization, the technical condition of transformers was linked to their importance in power system (Fig. 7), which allowed to divide given population into three basic groups of further exploitation: transformers with simplified operation (U), transformers with normal operation (N) and transformers with special operation (S). TrafoGrade system is a modern tool for diagnostics and management of transformers. The complex assessment of technical condition gives a lot of important information to be applied in logistic actions and financial policy of transformers operators. The important advantage of TrafoGrade system is simple form of assessment presentation, helping to analyze results of measurement both by engineering staff and managing personnel without wide technical knowledge.
Źródło:
Pomiary Automatyka Kontrola; 2009, R. 55, nr 1, 1; 65-68
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ warunków geologicznych na technologię eksploatacji pokładu węgla w przyspągowych partiach złoża przy zastosowaniu koparki łańcuchowej
Influence of geological conditions on the technology of exploitation of coal near floor parts of the deposit using a bucket chain excavator
Autorzy:
Strempski, A.
Cichoń, T.
Powiązania:
https://bibliotekanauki.pl/articles/169459.pdf
Data publikacji:
2017
Wydawca:
Poltegor-Instytut Instytut Górnictwa Odkrywkowego
Tematy:
węgiel brunatny
koparka łańcuchowa
deniwelacje spągu
brown coal (lignite)
bucket chain excavator
floor denivelations
Opis:
W kopalniach odkrywkowych węgla brunatnego ważnym elementem procesu wydobywczego jest eksploatacja węgla w przyspągowych partiach złoża. W niniejszym artykule przedstawiono analizę sposobów pracy koparki łańcuchowej zbliżonej budową do koparki typu ERs 710, podczas eksploatacji przyspągowych partii złoża węgla brunatnego w zróżnicowanych warunkach jego zalegania. Analizę przeprowadzono dla pokładu węgla brunatnego, charakteryzującego się nieregularnością granic, zmienną miąższością oraz znacznymi deniwelacjami spągu. Opisano i zilustrowano na schematach proponowany sposób urabiania węgla w deniwelacjach pokładu, którego miąższość przekracza możliwości wynikające z zasięgu pionowego omawianej koparki łańcuchowej. Przedstawiona na schematach technologia pracy maszyn zależna jest głównie od miąższości pokładu oraz od współpracy z koparką kołową (w tym z zastosowaniem przejezdnego przenośnika PGOT).
In brown coal (lignite) opencast mines an exploitation of coal near floor parts of a deposit is a very important part of operations. In the article, an analysis of bucket chain excavator ways of work in varied conditions of floor parts of the deposit, has been presented. The analysis has been done for a coal seam characterized by irregular borders, variable thickness and significant floor denivelations. The ways of exploitation of coal in floor drops exceeding excavator vertical capabilities have been presented. Presented bucket chain excavator exploitation technology is dependent mainly on seam thickness and cooperation with bucket wheel excavator including use of PGOT mobile conveyor.
Źródło:
Górnictwo Odkrywkowe; 2017, 58, 1; 16-21
0043-2075
Pojawia się w:
Górnictwo Odkrywkowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Możliwości przekwalifikowania zasobów nieprzemysłowych do przemysłowych po zastosowaniu mechanicznego urabiania kopaliny
Opportunities of reclassification of non-economic resources into economic resources after application of mechanical mining
Autorzy:
Witt, A.
Pomorski, A.
Cichoń, T.
Powiązania:
https://bibliotekanauki.pl/articles/170274.pdf
Data publikacji:
2014
Wydawca:
Poltegor-Instytut Instytut Górnictwa Odkrywkowego
Tematy:
zasoby przemysłowe
urabianie mechaniczne
urabianie skał
koparka
spycharka
industrial resources
mechanical excavation
quarrying
excavator
bulldozer
Opis:
Przedstawiono możliwości przekwalifikowania zasobów nieprzemysłowych do przemysłowych w kopalniach eksploatujących skały zwięzłe urabiane materiałem wybuchowym w wyniku zmiany metody urabiania. Wprowadzenie metod urabiania mechanicznego w tych częściach złoża umożliwia pozyskanie dodatkowych zasobów, co jest równoznaczne z poprawieniem ich stopnia wykorzystania. W celu uzyskania optymalnych wyników przedstawione metody urabiania skał zwięzłych należy dostosować do parametrów urabianych skał.
Presentation of the possibility of reclassification of non-economic resources into economic resources in mines exploiting solid rocks with use of explosives. Introduction of mechanical mining methods in those parts of the deposit enables mobilizing additional resources, which leads to improving their use. The presented solid rock mining methods must be adapted to the parameters of mined rock in order to obtain optimum results.
Źródło:
Górnictwo Odkrywkowe; 2014, 55, 2-3; 97-104
0043-2075
Pojawia się w:
Górnictwo Odkrywkowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Surfactant-assisted fabrication and evaluation of macroporous calcium phosphate bone cements
Autorzy:
Cichoń, E.
Zima, A.
Ślósarczyk, A.
Powiązania:
https://bibliotekanauki.pl/articles/286139.pdf
Data publikacji:
2018
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
bone cements
calcium
phosphate
Źródło:
Engineering of Biomaterials; 2018, 21, 148; 56
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Instytut Technik Innowacyjnych EMAG w Polsce i na świecie
Institute of Innovative Technologies EMAG in Poland and abroad
Autorzy:
Keller, J.
Cichoń, W.
Slotorsz, A.
Powiązania:
https://bibliotekanauki.pl/articles/186029.pdf
Data publikacji:
2012
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technik Innowacyjnych EMAG
Tematy:
Instytut Technik Innowacyjnych EMAG
Institute of Innovative Technologies EMAG
Opis:
W artykule przedstawiono dotychczasowe osiągnięcia Instytutu Technik Innowacyjnych w dostarczaniu krajowemu i zagranicznemu przemysłowi rozwiązań, niezbędnych do prowadzenia nowoczesnych procesów technologicznych, a także potencjał, możliwości, zakres działalności oraz pozycję EMAG-u. Zaprezentowano również przykłady działalności wdrożeniowej Instytutu oraz określono nowe podejście do kwestii komercjalizacji w ramach Centrum Naukowo-Przemysłowego EMAG. Omówiona została również strategia rozwoju Instytutu na najbliższe lata.
The article features the achievements of the Institute of Innovative Technologies EMAG in providing solutions indispensable for modern technological processes to national and international industrial organizations. Additionally, the article presents EMAG's potential, abilities and operation scope, as well as the Institute's position on the market. Some examples of EMAG's implementation projects were described, along with the new approach to commercialization issues represented by the Science and Industrial Centre EMAG. Finally, the authors discussed the Institute's development strategy for the nearest future.
Źródło:
Mechanizacja i Automatyzacja Górnictwa; 2012, R. 50, nr 3, 3; 3-13
0208-7448
Pojawia się w:
Mechanizacja i Automatyzacja Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zapis zakończenia eksploatacji rud Zn-Pb w osadach rzeki i małych zbiorników wodnych
Record of cessation the Zn-Pb ore extraction in river and small water reservoirs sediments
Autorzy:
Ciszewski, D.
Cichon, S.
Wojtal, A.
Powiązania:
https://bibliotekanauki.pl/articles/2078053.pdf
Data publikacji:
2018
Wydawca:
Uniwersytet Warszawski. Wydział Geografii i Studiów Regionalnych
Źródło:
Prace i Studia Geograficzne; 2018, 63, 3; 119-132
0208-4589
Pojawia się w:
Prace i Studia Geograficzne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Możliwości wykorzystania trudno zbywalnych frakcji amfibolitu ze złoża Pagórki Wschodnie
Possibilities of utilization of difficult-to-market amphibolite fractions from the Pagórki Wschodnie deposit
Autorzy:
Maliszewski, M.
Pomorski, A.
Cichoń, T.
Powiązania:
https://bibliotekanauki.pl/articles/170078.pdf
Data publikacji:
2017
Wydawca:
Poltegor-Instytut Instytut Górnictwa Odkrywkowego
Tematy:
amphibolite
difficult-to-market fractions
agriculture
ceramic industry
utilization
amfibolit
trudno zbywalne frakcje
rolnictwo
przemysł ceramiczny
zagospodarowanie
Opis:
Artykuł dotyczy alternatywnych możliwości zagospodarowania trudno zbywalnych frakcji amfibolitu ze złoża Pagórki Wschodnie. Aktualnie amfibolit wydobywany jest wyłącznie ze złóż położonych na terenie województwa dolnośląskiego. W roku 2015 eksploatowano trzy złoża (Ogorzelec, Pagórki Wschodnie i Piława Górna), z których wydobyto 1214 tys. ton surowca. Skład chemiczny amfibolitu ze złoża Pagórki Wschodnie został oznaczony za pomocą optycznego spektrometru emisyjnego oraz techniki SEM-EDS. W artykule przedstawiono dwa kierunki zastosowania drobnych frakcji amfibolitu, w rolnictwie i przemyśle ceramicznym.
This article concerns the alternative ways of managing of difficult-to-market amphibolite fractions from the Pagórki Wschodnie deposit. Currently, amphibolite is only exploited from deposits located in the Lower Silesia. In 2015, three deposits (Ogorzelec, Pagórki Wschodnie and Piława Górna) were exploited and 1 million 214 thousand tons of raw minerals were mined. The chemical composition of the amphibolite from the Pagórki Wschodnie was determined by an optical emission spectrometer and the SEM-EDS technique. This article presents two directions for the use of fine amphibolite fractions, in agriculture and in the ceramic industry.
Źródło:
Górnictwo Odkrywkowe; 2017, 58, 5; 4-10
0043-2075
Pojawia się w:
Górnictwo Odkrywkowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hydroxyapatite - chitosan material with silver nanoparticles
Autorzy:
Zima, A.
Czechowska, J.
Cichoń, E.
Ślósarczyk, A.
Powiązania:
https://bibliotekanauki.pl/articles/285308.pdf
Data publikacji:
2018
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
hydroxyapatite
chitosan
nanoparticles
Źródło:
Engineering of Biomaterials; 2018, 21, 148; 57
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie biopreparatow Biosept 33 SL i Biochikol 020 PC w formie moczenia sadzonek do ochrony truskawki przed wertycylioza
The effectiveness of Biosept 33 SL and Biochicol 020 PC biopreparations in protecting strawberry plants against Verticillium wilt
Autorzy:
Marjanska-Cichon, B.
Sapieha-Waszkiewicz, A.
Mietkiewski, R.
Powiązania:
https://bibliotekanauki.pl/articles/832228.pdf
Data publikacji:
2008
Wydawca:
Instytut Ogrodnictwa
Tematy:
werticilioza
choroby roslin
truskawka
ochrona roslin
biopreparaty
sadzonki
moczenie
Biosept 33 SL
Biochikol 020 PC
krzewy owocowe
Źródło:
Zeszyty Naukowe Instytutu Sadownictwa i Kwiaciarstwa w Skierniewicach; 2008, 16; 163-169
1234-0855
Pojawia się w:
Zeszyty Naukowe Instytutu Sadownictwa i Kwiaciarstwa w Skierniewicach
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Występowanie i skład gatunkowy grzybów owadobójczych w glebach z sadów jabłoniowych
The spectrum and occurrence of entomopathogenic fungi in soils from apple orchards
Autorzy:
Marianska-Cichon, B.
Mietkiewski, R.
Sapieha-Waszkiewicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/27449.pdf
Data publikacji:
2005
Wydawca:
Polskie Towarzystwo Botaniczne
Opis:
The spectrum and occurrence of entomopathogenic fungi in orchard soil and arable soil were evaluated using an „insect bait method”. Soil samples taken in autumn and spring from sward, herbicides fallow and arable soil were baited with Galleria mellonella larvae. Entomopathogenic fungi Beauveria bassiana (Bals.) Vuill., Metarhizium anisopliae (Metsch.) Sorok. and Paecilomyces fumosoroseus (Wize) Brown et Smith were isolated from three species of orchards soil and adjacent arable soil. Infection levels of G. mellonella larvae were depended from species of soil. M. anisoopliae caused most frequent infections of bait insects in light loamy sand and P. fumosoroseus in alluvial silt and coarse sand. B. bassiana was dominated in alluvial silt. It was established that M. anisopliae and B. bassiana infected more larvae in autumn than in spring. In case of P. fumosoroseus an opposite tendency was observed. Generály in arable soil and sward number of infected larvae was higher than other stands. In case of light loamy sand more infections of G. mellonella larvae were found in samples from herbicides fallow. Irrespective of soil type B. bassiana was the dominated species isolated from herbicides fallow, M. anisopliae from sward and P. fumosoroseus - from arable soil.
Przy pomocy metody owadów pułapkowych badano skład gatunkowy i nasilenie występowania grzybów owadobójczych w 3 gatunkach gleb z sadów jabłoniowych, w ugorze herbicydowym, murawie i polu uprawnym przylegającym do danego sadu. Obserwacje śmiertelności larw prowadzono jesienią i wiosną. W ciągu 3 lat prowadzenia badań wykazano, że występowanie grzybów owadobójczych zależało od gatunku gleby; im była ona lżejsza, tym rejestrowano więcej infekcji larw G. mellonella. W pyle ilastym i piasku gliniastym mocnym dominował P. fumosoroseus, a w piasku słabo gliniastym - M. anisopliae. Jesień sprzyjała występowaniu B. bassiana w pyle ilastym oraz M. anisopliae w piasku gliniastym mocnym i piasku słabo gliniastym. Wiosną zaś, w pyle ilastym i piasku gliniastym mocnym częściej infekował larwy grzyb P. fumosoroseus, a w piasku słabo gliniastym M. anisopliae i P. fumosoroseus wywoływały zbliżone nasilenie mikoz. Ugór herbicydowy i murawa na piasku słabo gliniastym charakteryzowały się największą liczbą odławianych grzybów w porównaniu z glebą orną i pozostałymi gatunkami gleb. Niezależnie od gleby grzyb B. bassiana dominował w ugorze herbicydowym, M. anisopliae w murawie, a P. fumosoroseus w glebie ornej.
Źródło:
Acta Agrobotanica; 2005, 58, 1
0065-0951
2300-357X
Pojawia się w:
Acta Agrobotanica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Calcium bioavailability from Ricotta-type cheeses produced by high-acid method of milk coagulation
Biologiczna dostepnosc wapnia w serach typu Ricotta otrzymanych metoda termiczno-kwasowej koagulacji mleka
Autorzy:
Klobukowski, J.
Surazynski, A.
Cichon, R.
Kozikowski, W.
Powiązania:
https://bibliotekanauki.pl/articles/1373121.pdf
Data publikacji:
1997
Wydawca:
Instytut Rozrodu Zwierząt i Badań Żywności Polskiej Akademii Nauk w Olsztynie
Tematy:
zawartosc tluszczu
ser ricotta
przetwory mleczne
bialko
sery
wapn
tluszcze
magnez
fosfor
zawartosc bialka
laktoza
zywienie czlowieka
Opis:
The calcium bioavailability from unripening cheeses produced by high heat-acid coagulation of milk was the major purpose of this work. The cheeses may supply a significant portion of the calcium needs for humans because of their total calcium content (from 747 to 605.6 mg/100 g cheese) and satisfactory Ca/P ratio (from 1.55 to 1.85). High bioavailability of calcium from the cheeses, expressed as the apparent absorption (from 57.4 ±0.6 to 60.5 ±1.1%) and retention (from 52.0±1.1 to 52.2±0.6%) make these dairy products to be an important source of available calcium in the human diet.
Oznaczono zawartość białka, tłuszczu, wapnia, fosforu, magnezu, laktozy (tab.2) w serach typu Ricotta I i II otrzymanych doświadczalnie w skali półtechnicznej w hali technologicznej Instytutu Technologii Mleczarskiej AR-T w Olsztynie. Sery typu Ricotta I i II wyprodukowano z mleka pasteryzowanego (95 °C/15 s), poddanego następnie koagulacji kwasowej w temperaturze 90°C (ser typu Ricotta I) i 80°C (ser typu Ricotta II). Ponadto na rosnących szczurach szczepu Wistar określono biodostępność wapnia metodą bilansową i wyrażono ją za pomocą wskaźników absorpcji pozornej (A), retencji pozornej (R) oraz kumulacją tego składnika mineralnego w kościach (tab.3). Badania wykazały wysoką koncentrację wapnia i korzystny stosunek Ca : P w serach typu Ricotta I i II (tab.1). Uzyskano wysoką biodostępnośc wapnia z badanych produktów mlecznych (tab.3), które mogą stanowić istotne źródło przyswajalnego wapnia w racji pokarmowej człowieka.
Źródło:
Polish Journal of Food and Nutrition Sciences; 1997, 06, 2; 97-104
1230-0322
2083-6007
Pojawia się w:
Polish Journal of Food and Nutrition Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of biopreparations and synthetic fungicides on growth on micorrhizal fungus Oidiodendron sp. in vitro
Wpływ biopreparatów i syntetycznych fungicydów na wzrost in vitro grzyba mikoryzowego Oidiodendron sp.
Autorzy:
Marjańska-Cichoń, B.
Sapieha-Waszkiewicz, A.
Miętkiewski, R.
Powiązania:
https://bibliotekanauki.pl/articles/11364526.pdf
Data publikacji:
2005
Wydawca:
Uniwersytet Przyrodniczy w Lublinie. Wydawnictwo Uniwersytetu Przyrodniczego w Lublinie
Tematy:
Biosept 33 SL biopreparation
synthetic fungicide
propolis
fungi
growth colony
Oidiodendron
Bioczos SL biopreparation
fungicide
mycorrhizal fungi
growth
Biochikol 020 PC preparation
in vitro growth
Opis:
The influence of biopreparations Bioczos SL, Biosept 33 SL, Biochikol 020 PC, Propolis and synthetic fungicides Euparen Multi 50 WG, Horizon 250 EW and Teldor 500 SC was examined on the growth of micorrhizal fungus Oidiodendron sp. Fungicides were added to PDA medium at the following concentrations: recommended dose, 5-times lower than the recommended and 5-times higher than the recommended. The synthetic fungicides were more toxic to Oidiodendron sp. than biopreparations. On the medium containing Horizon 250 EW fungus did not growth. The greather part of biopreparations inhibited growth of Oidiodendron sp. but only Bioczos SL and Propolis in dose 5-times higher than the recommended, toataly inhibited growth of fungus colonies.
Badano wpływ biopreparatów Bioczos SL, Biosept 33 SL, Biochikol 020 PC, Propolis oraz fungicydów syntetycznych Euparen Multi 50 WG, Horizon 250 EW oraz Teldor 500 SC, na wzrost i rozwój grzyba mikoryzowego Oidiodendron sp. Do pożywki PDA dodawano badane preparaty w dawkach: zalecanej w praktyce rolniczej, 5-krotnie mniejszej i 5-krotnie większej od zalecanej, a następnie inokulowano grzybem Oidiodendron sp. Wykazano, że fungicydy syntetyczne okazały się bardziej toksyczne w stosunku do badanego grzyba niż biopreparaty. Preparat Horizon 250 EC przy koncentracji zalecanej uniemożliwił wzrost grzyba do końca trwania eksperymentu. Większość biopreparatów ograniczało wzrost grzyba Oidiodendron sp., lecz tylko przy stężeniu najwyższym, w przypadku Bioczosu SL oraz Propolisu, obserwowano całkowite zahamowanie wzrostu kolonii grzyba.
Źródło:
Acta Scientiarum Polonorum. Hortorum Cultus; 2005, 04, 2; 11-19
1644-0692
Pojawia się w:
Acta Scientiarum Polonorum. Hortorum Cultus
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
DVB-T Channels Measurements for the Deployment of Outdoor REM Databases
Autorzy:
Kliks, A.
Kryszkiewicz, P.
Cichoń, K.
Umbert, A.
Perez-Romero, J.
Casadevall, F.
Powiązania:
https://bibliotekanauki.pl/articles/307830.pdf
Data publikacji:
2014
Wydawca:
Instytut Łączności - Państwowy Instytut Badawczy
Tematy:
channel measurements
DVB-T
spectrum occupancy
Radio Environment Maps
Opis:
In this paper the analysis of the spectrum occupancy in the TV band is provided based on the outdoor measurements campaigns carried out in Poznań, Poland in 2013 and 2014. The goal of this work is to discuss the stability and other important features of the observed spectrum occupancy in the context of outdoor Radio Environment Maps database deployment. Reliable deployment of these databases seems to be one of the critical points in practical utilization of the TV White Spaces for cognitive purposes inside buildings and in densely populated cities. The results obtained for outdoor scenario are briefly compared with the previous measurements conducted indoors in Barcelona, Spain, and in Poznań, Poland.
Źródło:
Journal of Telecommunications and Information Technology; 2014, 3; 42-52
1509-4553
1899-8852
Pojawia się w:
Journal of Telecommunications and Information Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reakcja grzybów owadobójczych na fungicydy pochodzenia roślinnego i syntetycznego in vitro
A response of entomopathogenic fungi to botanical fungicides and synthetic fungicides in vitro
Autorzy:
Sapieha-Waszkiewicz, A.
Marjanska-Cichon, B.
Mietkiewski, R.
Zurek, M.
Powiązania:
https://bibliotekanauki.pl/articles/26799.pdf
Data publikacji:
2005
Wydawca:
Polskie Towarzystwo Botaniczne
Opis:
The growth colonies’ morphology and sporulation of entomopathogenic fungi was estimated on Sabouraud medium containing botanical fungicides (Bioczos liquid and Biosept 33 SL), and synthetic ones (Teldor 500 SC and Sumilex 500 SC). Entomopathogenic fungi (Beauveria bassiana (Balls.) Vuill., Metarhizium anisopliae (Metsch.) Sorok, and Paecilomyces fumosoroseus (Wize) Brown et Smith.), were isolated from soil by means of Galleria mellonella larvae as baits. Isolates Bb I, Ma I, Pf I delivered from herbicide fallow from apple orchard and isolates Bb II, Ma II and Pf II from arable field adjacent to orchard. Fungicides were added to Sabouraud medium at the following concentrations: A-recommended dose, B-10-times lower than the recommended, C-100-times lower than the recommended. The growth of colonies their morphological changes and sporulations were estimated after 5 and 20 days. The same parametrs were observed when fungi were transfered from the medium containing fungicides on the medium with out fungicides. From botanical fungicides Bioczos liquid inhibited fungal growth more than Biosept 33 SL. Both of fungicides were most toxic to fungi at concentration A. Both of P. fumosoroseus isolates were the most sensitive to Bioczos liquid and M. anisopliae to Biosept 33 SL. All concentrations of synthetic fungicides (Sumilex 500 SC, Teldor 500 SC) restricted growth of B. bassiana and M. anisopliae isolates more from arable soil than from herbicide fallow but opposite reaction was found with respect to P. fumosoroseus.
Badano oddziaływanie fungicydów pochodzenia roślinnego Bioczos pł. i Biosept 33 SL oraz syntetycznych - Sumilex 500 SC i Teldor 500 SC na wzrost, morfologię i zarodnikowanie grzybów owadobójczych in vitro. Grzyby owadobójcze Beauveria bassiana (Bals.) Vuill. (Bb I, Bb II), Metarhizium anisopliae (Metsch.) Sorok (Ma I, Ma II) i Paecilomyces fumosoroseus (Wize) Brown et Smith. (Pf I, Pf II) wyizolowano z gleby metodą owadów pułapkowych na larwy Galleria mellonella L. Izolaty Bb I, Ma I, Pf I pochodziły z ugoru herbicydowego z sadu jabłoniowego, a izolaty Bb II, Ma II i Pf II - z pola uprawnego sąsiadującego z sadem. Fungicydy dodano do sterylnego podłoża Sabouraďa w 3 koncentracjach: A - zalecanej w praktyce rolniczej, B - 10-krotnie mniejszej i C - 100-krotnie mniejszej od zalecanej. W 5 i 20 dniu eksperymentu obserwowano wzrost kolonii, zmiany morfologiczne oraz zarodnikowanie kultur. Zbadano również następczy wpływ fungicydów na cechy morfologiczne i wzrost kolonii grzybów. Z preparatów pochodzenia roślinnego Bioczos pł. silniej ograniczał wzrost testowanych grzybów owadobójczych niż Biosept 33 SL. Oba preparaty były najbardziej toksyczne dla badanych grzybów przy koncentracji A. Bioczos pł. był najbardziej toksyczny dla obu izolatów P. fumosoroseus, a Biosept 33 SL dla M. anisopliae. Fungicydy syntetyczne Sumilex 500 SC oraz Teldor 500 SC przy wszystkich koncentracjach silniej hamowały wzrost izolatów M. anisopliae i B. bassiana z pola uprawnego oraz izolatu P. fumosoroseus z ugoru harbicydowego.
Źródło:
Acta Agrobotanica; 2005, 58, 1
0065-0951
2300-357X
Pojawia się w:
Acta Agrobotanica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Adnexal torsion – can laparoscopy wait?
Skręt przydatków – czy laparoskopia może poczekać?
Autorzy:
Cichoń, Bartosz
Słowik, Łukasz
Baran, Katarzyna
Gadomska, Aleksandra
Gilewska, Justyna
Cichoń, Tomasz
Lemm, Magdalena A.
Bakon, Igor
Witek, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/1426938.pdf
Data publikacji:
2021-02-28
Wydawca:
Śląski Uniwersytet Medyczny w Katowicach
Tematy:
adnexal torsion
ovaries
laparoscopy
skręt przydatków
jajnik
laparoskopia
Opis:
Adnexal torsion is a rare emergency condition and its diagnosis is challenging as the clinical presentation is nonspecific. About half of the cases of adnexal torsion are not identified in a timely manner. It is important to undergo prompt surgery to preserve ovarian function. Our article describes the clinical presentation of adnexal torsion and early surgical intervention to preserve the adnexa in a young woman.
Skręt przydatków jest rzadkim stanem nagłym, a jego diagnoza jest wyzwaniem, ponieważ objawy kliniczne są niecharakterystyczne. Około połowy przypadków skrętu przydatków pozostaje nierozpoznana w odpowiednim czasie. Podjęcie szybkiego leczenia operacyjnego jest istotne, aby zachować funkcję jajnika. W artykule opisano objawy kliniczne skrętu przydatków i wczesną interwencję chirurgiczną pozwalającą na zachowanie przydatków u młodej pacjentki.
Źródło:
Annales Academiae Medicae Silesiensis; 2021, 75; 8-10
1734-025X
Pojawia się w:
Annales Academiae Medicae Silesiensis
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Projekt konstrukcyjny bezrzędowej maszyny do zbioru roślin energetycznych
Constructional design of a machine for harvesting energy plants grown without rows
Autorzy:
Lisowski, A.
Nowakowski, T.
Strużyk, A.
Waszkiewicz, C.
Klonowski, J.
Kasperek, D.
Cichoń, M.
Powiązania:
https://bibliotekanauki.pl/articles/290137.pdf
Data publikacji:
2010
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
roślina energetyczna
zbiór
maszyna bezrzędowa
energy plant
harvest
machine
Opis:
W pracy opisano prototyp uniwersalnej, bezrzędowej maszyny do zbioru roślin energetycznych w formie zrębków lub sieczki. Na przystawki ścinające, które wykonano w dwóch wersjach, złożono do Urzędu Patentowego zastrzeżenie patentowe P 385 536. W jednej z wersji zespół podający jest w postaci palców sprężystych, a w drugiej - walców ślimakowych. Maszyna ma budowę modułową, co zapewni jej łatwą modyfikację, a napęd hydrauliczny ze sterowaniem elektrohydraulicznym pozwoli na dobranie optymalnych parametrów pracy elementów i zespołów roboczych, do różnych warunków polowych. Maszyna może ścinać rośliny na wysokości do 100 mm o średnicy pędów do 70 mm i rozdrabniać na cząstki o wymiarze 20-60 mm.
The paper describes prototype of a universal machine for harvesting energy plants grown without rows, in form of chips or chaff. Patent Office received patent claim no. P 385 536 concerning cutting attachments made in two versions. In one of them, feeding unit has the form of elastic fingers, and in second - worm rollers. The machine has modular structure allowing its easy modifications. Hydraulic drive with electro-hydraulic control will allow to select optimal parameters for working elements and units in various field conditions. The machine may cut down plants at the height of up to 100 mm, for sprout diameters reaching up to 70 mm, and shred them into pieces sized 20-60 mm.
Źródło:
Inżynieria Rolnicza; 2010, R. 14, nr 2, 2; 19-25
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena adaptacji układu krążenia u kobiet 34–35-letnich w spoczynku oraz w wysiłku fizycznym w stanie równowagi dynamicznej
Evaluation of circulatory system adaptation in women aged 34–36 years during rest and steady state exercise
Autorzy:
Fortuna, M.
Szczurowski, J.
Demczyszak, I.
Konieczna–Gorysz, A.
Cichon, D.
Powiązania:
https://bibliotekanauki.pl/articles/12436.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Szczeciński
Opis:
The aim of the study was to evaluate the adaptation of the circulatory system based on the HRV at rest and at steady state. They studied 33 women (34–36 years old), who exercised on the steady-state level of 70–80% of maximum heart rate. ECG was recorded using a Polar RS800 at rest and during effort. Analyzed parameters: RMSSD, pNN50%, HF%, VLF%, LF%, LF/HF. All test results compared to the rest of effort showed statistically significant differences. The following conclusions was stated: HRV may be used to evaluate the adaptation of the circulatory system; during steady-state exercise exists reducing the impact of parts of parasympathetic and increasing the influence of sympathetic part the autonomic nervous system; analysis of HRV indicates the increasing influence of the renin–angiotensin system and thermoregulation during exercise.
Źródło:
Aktywność Ruchowa Ludzi w Różnym Wieku; 2016, 4[32]
2299-744X
Pojawia się w:
Aktywność Ruchowa Ludzi w Różnym Wieku
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effects of brine and salting time on bioavailability of minerals from ripening cheeses
Wplyw rodzaju solanki i czasu solenia na biodostepnosc skladnikow mineralnych serow dojrzewajacych
Autorzy:
Klobukowski, J.
Kozikowski, W.
Cichon, R.
Wisniewska-Pantak, D.
Reps, A.
Powiązania:
https://bibliotekanauki.pl/articles/1373153.pdf
Data publikacji:
1997
Wydawca:
Instytut Rozrodu Zwierząt i Badań Żywności Polskiej Akademii Nauk w Olsztynie
Tematy:
czas solenia
ser tylzycki
solenie
sery dojrzewajace
solanki
biodostepnosc
ser jezioranski
skladniki mineralne
Opis:
The bioavailabilities of potassium, sodium and calcium from two types of cheeses, Jeziorański and Tilsit, salted in a 20% NaCl solution or NaCl/KCl, 1:1, solution for a standard salting time (SST) or 25% of SST, were studied. The bioavailability was determined by the classical balance method based on the element intake and its excretion with faeces and urine using growing Wistar rats. The ability to assimilate the mineral elements was expressed by apparent absorption (A) and retention (R) coefficients. The type of brine did not affect significantly the intakes of sodium (25% SST) and calcium (100% SST) by rats fed the cheeses. The intake of potassium from both types of cheeses was significantly dependent on the type of brine. The salting time of Jeziorański cheese significantly influenced the intakes of sodium, potassium and calcium independent of the type of brine. The type of brine and time of salting significantly affected the apparent absorption and retention of minerals for the diets selected for statistical analysis.
Badaniom poddano próby serów dojrzewających: jeziorańskiego i tylżyckiego, wyprodukowane w Zakładach Mleczarskich w Iławie i Biskupcu. Sery solono w 20% roztworach NaCl oraz w mieszaninie NaCl i KCl (1:1). Stosowano ponadto różny czas solenia wynoszący 25% i 100% czasu normatywnego. Biodostępność sodu, potasu i wapnia określano metodą bilansową na rosnących szczurach szczepu Wistar w oparciu o spożycie danego pierwiastka i jego wydalanie z kalem i moczem. Przyswajalność badanych składników mineralnych wyrażano wskaźnikami absorpcji (A) i retencji (R) pozornej. Wykazano, że rodzaj stosowanej solanki nie miał istotnego wpływu na spożycie Na (25%) i Ca (100% czasu normatywnego) przez szczury żywione badanymi serami (tab.1). Stwierdzono, że wielkość spożycia potasu dla obu gatunków serów zależała istotnie od rodzaju solanki (tab. 1). Zanotowano istotny wpływ czasu nasolenia sera jeziorańskiego na spożycie Na, K i Ca niezależnie od rodzaju solanki (tab. 1). Rodzaj solanki i czas solenia serów wpływał istotnie na absorpcję i retencję pozorną badanych składników mineralnych z wybranych do analizy statystycznej diet doświadczalnych (tab. 2).
Źródło:
Polish Journal of Food and Nutrition Sciences; 1997, 06, 1; 137-146
1230-0322
2083-6007
Pojawia się w:
Polish Journal of Food and Nutrition Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Magnetoacoustic tomography with magnetic induction for low conductivity objects
Tomografia magnetoakustyczna ze wzbudzeniem indukcyjnym do badania obiektów o niskiej konduktywności
Autorzy:
Cichoń-Bańkowska, K.
Ziółkowski, M.
Gratkowski, S.
Stawicki, K.
Brykalski, A.
Szymanik, B.
Żywica, A.
Powiązania:
https://bibliotekanauki.pl/articles/261327.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Wydział Podstawowych Problemów Techniki. Katedra Inżynierii Biomedycznej
Tematy:
magnetoacoustic tomography
magnetic induction
conductivity imaging of biological structures
tomografia magnetoakustyczna
wzbudzenie indukcyjne
obrazowanie konduktywności struktur biologicznych
Opis:
This paper presents a new promising non-invasive electrical conductivity imaging method of low-conductivity objects (e.g. biological tissues), called Magneto-Acoustic Tomography with Magnetic Induction (MAT-MI). The described method combines ultrasound and magnetism into one unified hybrid technique. The object is placed in a static and a pulsed (μs) magnetic field. The time-varying (pulsed) magnetic field induces eddy currents in the object. Consequently, the object emit ultrasonic waves through the Lorentz force produced by the combination of the eddy current and the static magnetic field. The ultrasonic waves are then collected by the detectors located around the object for image reconstruction. MAT-MI combines the good contrast of Electrical Impedance Tomography (EIT) with the good spatial resolution of sonography. The aim of this paper is a review of theoretical studies of MAT-MI and discussion of possible future research directions.
W pracy opisano nową obiecującą metodę nieinwazyjnego obrazowania przewodności elektrycznej obiektów słabo przewodzących (np. tkanek biologicznych) zwaną tomografią magnetoakustyczną ze wzbudzeniem indukcyjnym (ang. Magneto-Acoustic Tomography with Magnetic Induction – MAT-MI). Prezentowana metoda jest techniką hybrydową i łączy badania ultradźwiękowe z magnetyzmem. Badany obiekt umieszczony jest w statycznym oraz impulsowym (μs) polu magnetycznym. Zmienne pole magnetyczne indukuje w nim prądy wirowe. W wyniku działania sił Lorentza powstałych dzięki interakcji prądów wirowych oraz statycznego pola magnetycznego, obiekt będzie emitował fale ultradźwiękowe. Fale te są odbierane przez detektory umieszczone wokół obiektu. Metoda MAT-MI łączy dobry kontrast elektrycznej tomografii impedancyjnej (ang. Electrical Impedance Tomography – EIT) z dobrą rozdzielczością przestrzenną metody ultradźwiękowej. Celem niniejszej pracy jest przegląd badań teoretycznych metody MAT-MI oraz dyskusja przyszłych kierunków badawczych.
Źródło:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna; 2014, 20, 4; 187-192
1234-5563
Pojawia się w:
Acta Bio-Optica et Informatica Medica. Inżynieria Biomedyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Investigation of Sediments Causing Damage to Water Meters in a Large Drinking Water Distribution System
Autorzy:
Kopeć, M.
Roman, M.
Kąc, M.
Budziak, A.
Paluszkiewicz, C.
Zarzycki, A.
Kąc, S.
Dutkiewicz, E.
Cichoń, T.
Bochnia, T.
Kwiatek, W.
Powiązania:
https://bibliotekanauki.pl/articles/1030652.pdf
Data publikacji:
2018-02
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
89.60.-k
78.70.En
61.05.cp
82.80.-d
82.80.Gk
Opis:
Preliminary studies on the sediments collected from water meters of Krakow water supply system were performed in the cooperation with the Municipal Water Supply and Sewage. Creation and deposition of sediments on the measuring devices installed in the water supply system is a serious technological and economical problem for water companies, defectively operating for this reason water meters must be replaced. It is evident that knowledge of the chemical and phase composition of sediments is an important step towards resolving the problem of impurities in water supply systems. Four different samples of sediments, coming from water meters, were investigated using the proton-induced X-ray emission, the X-ray diffraction, the Fourier transform infrared and Raman spectroscopy. The X-ray methods revealed presence of amorphous and fine-crystalline phases as well as high content of iron-based compounds. As a crystalline phase, the most frequently appeared: goethite, lepidocrocite, iron oxides (hematite, maghemite, magnetite), calcium carbonate, and quartz. In one of the samples, the nanocrystalline phase was found and identified as hydrous iron oxyhydroxide ferrihydrite. Vibrational spectroscopy methods confirmed the composition of crystalline phases as well as enabled to estimate the abundance of amorphous phase in samples.
Źródło:
Acta Physica Polonica A; 2018, 133, 2; 296-301
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nutritional habits of perinatal women for consumption of butter and margarine
Zwyczaje zywieniowe kobiet w okresie okoloporodowym w zakresie spozycia masla i margaryny
Autorzy:
Wadolowska, L.
Przybylowicz, K.
Trzaskowska, M.A.
Cichon, R.
Kozikowski, W.
Klobukowski, J.
Stefanowicz, M.
Romaszko, E.
Malarkiewicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/1373146.pdf
Data publikacji:
1997
Wydawca:
Instytut Rozrodu Zwierząt i Badań Żywności Polskiej Akademii Nauk w Olsztynie
Tematy:
maslo
okres okoloporodowy
tluszcze jadalne
nawyki zywieniowe
spozycie zywnosci
kobiety
margaryna
zywienie czlowieka
Opis:
The nutritional habits of perinatal women for consumption of butter and margarine were determined. The study was performed on 231 women by collecting the information about both the consumption of fats used as bread spreads or dish and culinary additives, and the amount of margarine consumed regularly for spreading on bread. The correlation between the nutritional habits and selected socio-economical factors such as place of residence, education, occupation and declared economical status, was analysed. Margarines were found to be used commonly for spreading on bread and were more often used for preparing cakes and cake fillings than butter. These two fats were thus recognized as the most important sources of trans fatty acid isomers taken by the studied women. No correlation was found between the intake of margarine as bread spread and examined socio-economical factors. High consumption of margarines by perinatal women should be considered alarming because of the possibility for the incidence of trans fatty acid isomers in breast milk in the amounts that are danger for the health of their children.
Określono zwyczaje żywieniowe kobiet w okresie okołoporodowym w zakresie spożycia masła i margaryny. Badaniami objęto 231 kobiet zbierając informacje o spożyciu tłuszczów stosowanych do smarowania pieczywa, dodawanych do potraw i stosowanych w procesach kulinarnych oraz określając ilość zwyczajowo spożywanych margaryn stosowanych do smarowania pieczywa. Analizie poddano współzależność rozpatrywanych cech odżywiania z wybranymi czynnikami socjoekonomicznymi, tj. miejscem zamieszkania, wykształceniem, rodzajem wykonywanej pracy i deklarowaną sytuacją materialną. Stwierdzone powszechne stosowanie margaryn do smarowania pieczywa oraz w porównaniu z masłem ich szersze wykorzystanie do wypieku ciast i przygotowywania kremów pozwoliło uznać te dwa źródła za najistotniejsze w spożyciu trans izomerów kwasów tłuszczowych przez badane kobiety (rys. 1,4,5,6). Nie stwierdzono współzależności pomiędzy spożyciem margaryn do smarowania pieczywa a rozpatrywanymi czynnikami socjoekonomicznymi (tab.1). Wykazano wysokie spożycie margaryn przez badane kobiety w okresie okołoporodowym uznając je za niepokojące z uwagi na możliwość pojawienia się trans izomerów kwasów tłuszczowych w mleku kobiecym w ilościach stwarzających zagrożenie dla zdrowia ich dzieci.
Źródło:
Polish Journal of Food and Nutrition Sciences; 1997, 06, 1; 127-136
1230-0322
2083-6007
Pojawia się w:
Polish Journal of Food and Nutrition Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-57 z 57

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies