Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Chen, Peng" wg kryterium: Autor


Tytuł:
Photo-oxidative Aging Behaviors of Acrylic Coatings during UV Irradiation Investigated by Positron Annihilation Spectroscopy
Autorzy:
Zhao, Xipo
Cai, Xiaolin
Liu, Chang
Chen, Ting
He, Chunqing
Fang, Pengfei
Peng, Shaoxian
Powiązania:
https://bibliotekanauki.pl/articles/1033253.pdf
Data publikacji:
2017-11
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
Acrylic coating
UV irradiation
positron annihilation spectroscopy
Opis:
Slow positron annihilation spectroscopy, contact angle and scanning electron microscope (SEM) were employed to investigate the surface polarity and morphologies as functions of aging time in acrylic coatings during UV-a irradiation. The S parameter plots of each exposed sample are lower than that of the virgin sample in the whole range of E. The S parameter plots become lower as the exposing longer time, indicated that the irradiation generated more polar groups and increased the oxidation layer depth. Combined with surface morphology and the surface energy of acrylic coating, the variation of contact angle, and surface energy, polar component and dispersive component is related with surface polarity and morphologies.
Źródło:
Acta Physica Polonica A; 2017, 132, 5; 1527-1530
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Classification techniques and parameter optimization of Cyclone Continuous Centrifugal Separator for hematite ore
Autorzy:
Zhang, Pei
Xie, Haiyun
Jin, Yanling
Chen, Jialing
Zeng, Peng
Li, Yuanhong
Chen, Luzheng
Liu, Dianwen
Powiązania:
https://bibliotekanauki.pl/articles/2200335.pdf
Data publikacji:
2023
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
hematite
Cyclonic Continuous Centrifugal Separator
CCCS
classification
Response Surface Methodology
Opis:
The Cyclonic Continuous Centrifugal Separator (CCCS) is a new type of separation equipment developed based on cyclonic continuous centrifugal separation technology and combined with the separation principle of the fluidized bed. Taking hematite as the research object, the main parameters and conditions of the best hematite classification were determined through the classification test by using CCCS. Based on the classification test, the significance order of each process parameter and their interaction with hematite classification efficiency of the underflow products was analyzed with the Response Surface Methodology, the optimal process parameter of hematite classification was obtained and a multiple regression equation was established. The optimized process conditions were as follows, feeding pressure 55.48 kPa, backwash pressure 9.79 kPa, and underflow pressure 31.94 kPa. Under these conditions, the average hematite ore classification efficiency of coarse fraction (-2~+0.15mm), medium fraction (-0.15~+0.074mm) and fine fraction (-0.074mm) were 85.08%, 65.10% and 51.41%, respectively, and the relative errors with the predicted values were 1.6%, 4.0% and 2.5%, respectively. The results showed that the analytical model has good predictive performance. This research provides a certain prospect for the application of Cyclonic Continuous Centrifugal Separation to hematite ore classification. it provides a reference for the application of the Response Surface Methodology in the classification of hematite by Cyclonic Continuous Centrifugal Separation.
Źródło:
Physicochemical Problems of Mineral Processing; 2023, 59, 1; art. no. 158864
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of foam separation in production of β-glucanase in Pichia
Autorzy:
Yuhang, Qin
Yuqing, Chen
Yajuan, Peng
Wenyao, Shao
Powiązania:
https://bibliotekanauki.pl/articles/2174820.pdf
Data publikacji:
2022
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
Foam separation
β-glucanase
recovery rate
enrichment ratio
Opis:
β-glucanase is widely used in many fields and has great economic value and development space, but it faces the difficulties of separation and nutrient destruction in the process of industrial production. Foam separation is a simple, mild and efficient adsorption separation technique that enables efficient separation and extraction of β-glucanase. In this study, five single factors(loading volume, pH, separation gas velocity, fermentation loading concentration, surfactant concentration) of foam separation and harvest of β-glucanase produced by Pichia pastoris were studied. The best univariate condition was: 600 mL/min separation gas velocity, loading volume of 200 mL, initial enzyme concentration of 100 g/mL, surfactant concentration of 0.3 mg/mL and pH of 5. Based on the best univariate condition, the optimal separation conditions of β-glucanase were further explored, and the five-factor four-level orthogonal test was designed. From the experimental results, the best separation condition was: 600 mL/min, loading volume of 200 mL, initial enzyme concentration of 100 μg/mL, surfactant concentration of 0.5 mg/mL and pH of 5. Under this separation condition, the enrichment ratio (E) was 0.56 and the recovery rate (R) was 96.01%.
Źródło:
Polish Journal of Chemical Technology; 2022, 24, 3; 1--7
1509-8117
1899-4741
Pojawia się w:
Polish Journal of Chemical Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Design and validation of a single-jack variable Mach number nozzle in a cryogenic transonic wind tunnel
Autorzy:
Yu, Chengguo
Zhang, Zhili
Wang, Ning
Nie, Xutao
Peng, Qiang
Chen, Zhenhua
Powiązania:
https://bibliotekanauki.pl/articles/2200829.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
cryogenic
flow uniformity
single-jack nozzle
transonic wind tunnel
variable
Mach number
Opis:
The wind tunnel with variable Mach numbers controlled by a single jack is highly desired in the aerospace, automobile and building industry due to its superior controllability and working range. Decreasing the temperature of a test gas is an efficient and economical approach to achieving higher Reynolds numbers that accommodate all working statuses of test subjects, which however, brings new challenges to the wind tunnel design nowadays. This paper proposes a new design concept of a single-jack variable Mach number nozzle based on its particular cryogenic characteristics, as the nozzle is the core structure to achieve variable Mach numbers. The contours of the nozzle under different Reynolds numbers and Mach numbers are modeled and solved by an incomplete elliptic integral, followed by modification with cryogenic characteristics. A 0.3-m cryogenic wind tunnel is utilized as a validation platform for the nozzle design, resulting in designed contours being in line with the measured contours. Moreover, the root means square (RMS) deviations of Mach number 1.3 at the core position are controlled within 0.011 in low and high temperatures, which surpasses the other existing wind tunnels.
Źródło:
Journal of Theoretical and Applied Mechanics; 2022, 60, 4; 719--732
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Damage and fracture analysis of bolted joints of composite materials based on peridynamic theory
Autorzy:
Yang, Na-Na
Zhao, Tian-You
Gu, Ji-Guang
Chen, Zhi-Peng
Powiązania:
https://bibliotekanauki.pl/articles/258888.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
peridynamic theory
composite material
damage and fracture
joints
Opis:
It is clear that the advantages of fibre glass-reinforced plastics surpass those of steel, but the failure analysis of composite structures is much more complex than that of isotropic materials as composite materials may fail in a variety of ways. In order to simulate the damage and fracture of bolted joints of fibre reinforced composite, the bond-based peridynamic method suitable for elastic, brittle and anisotropic characteristics of composite material is used. The peridynamic model for composite laminate is validated by the finite element method. Then a peridynamic program of composite damage is applied to calculating the damage of bolted joint structure and the damage propagation process and failure mode of the structure is obtained.
Źródło:
Polish Maritime Research; 2019, 2; 22-32
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Abnormal phase removing method in phase measuring profilometry
Autorzy:
Xu, X.
Cao, Y.
Chen, C.
Cao, S.
Peng, K.
Powiązania:
https://bibliotekanauki.pl/articles/173504.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
information optics
phase measuring profilometry
phase shifting algorithm
phase error
phase auto-extracting
Opis:
An abnormal phase removing method in phase measuring profilometry is proposed. In the five equal shifting phase steps algorithm, the shifting phase might be extracted from the deformed patterns captured by CCD camera. But there may be some errors introduced by a digital fringe projector and CCD camera in these deformed patterns. The impurity of the deformed patterns may lead to four classes of abnormalities when extracting the shifting phase. These abnormalities may cause the wrong shifting phase extraction by which the reconstructed object might be misshapen or anamorphic, or even in failure. By this proposed method, the above abnormalities can be removed, and the shifting phase can be auto-extracted precisely from the impure deformed patterns without knowing its value. Experimental results verify the feasibility and effectiveness of the proposed method.
Źródło:
Optica Applicata; 2017, 47, 1; 85-95
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Extraction and separation of zinc, lead, silver, and bismuth from bismuth slag
Autorzy:
Xing, Peng
Ma, Baozhong
Wang, Chengyan
Chen, Yongqiang
Powiązania:
https://bibliotekanauki.pl/articles/109744.pdf
Data publikacji:
2019
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
bismuth
zinc
lead
silver
extraction
separation
Opis:
The present paper deals with the extraction and separation of zinc, lead, silver, and bismuth from a refractory bismuth refining slag via a hydrometallurgical route. The process consists of a preliminary leaching of zinc with water, followed by the selective leaching of lead and silver with a calcium chloride solution, leading to the crystallization of lead chloride and the cementation of silver. The diagrams of the total concentrations of [Pb]/[Ag] versus [Cl-] and temperature in the Pb/Ag-Cl-H2O system were drawn, respectively, to determine the optimum concentration of leaching agent and leaching temperature. The potential-pH diagram of the Pb/Ag/Bi-H2O system indicates that the preferential leaching of lead and silver could be achieved. Finally, 98.8% of lead and 90.4% of silver were selectively removed by further leaching the water leaching residue with 400 g/dm3 of CaCl2 solution at pH 4.5 and 80 °C, while only 3.7% of bismuth was leached in this stage. Fifty-nine percent of lead in the leach liquor was separated out as PbCl2 by natural cooling. Ninety-five percent of silver in mother liquor was recovered by cementation with a lead sheet. The depleted CaCl2 solution can be sent to the leaching step again to close the loop.
Źródło:
Physicochemical Problems of Mineral Processing; 2019, 55, 1; 173-183
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Aspherical, sphero-cylindrical, toroidal, and ellipsoidal surfaces for designing astigmatic spectacle lenses with axis orientation
Autorzy:
Xiang, Huazhong
Wang, Peng
Zheng, Zexi
Zheng, Gang
Chen, Jiabi
Wang, Cheng
Zhang, Dawei
Zhuang, Songlin
Powiązania:
https://bibliotekanauki.pl/articles/27310110.pdf
Data publikacji:
2023
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
toric
astigmatism
spherocylinder
aspheric
ellipsoidal surface
Opis:
In this paper, formulas for aspherical, sphero-cylindrical, toroidal, and ellipsoidal surfaces with astigmatic axes are derived. Based on this, four types of curved surfaces were designed to correct astigmatism with axis, and, subsequently, the lenses were simulated, fabricated, and measured. A total of ten spectacle lenses in two groups were designed. Those in the first group used identical optical parameters. The spherical and cylindrical powers and maximum and minimum edge thicknesses of aspherical, sphero-cylindrical, and ellipsoidal surfaces were compared. The results indicated that the power of the lens constructed using the toroidal surface was more accurate than those of the other three lenses. Moreover, the minimum edge thickness of the toroidal surface was 1.2%, 4.98%, and 4.87% lower than those of the aspherical, sphero-cylindrical, and ellipsoidal surfaces, respectively. The powers and edge thicknesses of toroidal surfaces with different diopters were compared in the second group. The minimum and maximum edge thicknesses were observed to be reduced by 8.97% and 6.05%, respectively, corresponding to the conic constants obtained via ray tracing. The conclusion will be significant for clinical ophthalmology and optical design for the patients with astigmatism.
Źródło:
Optica Applicata; 2023, 53, 3; 377--391
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Free vibration of composite cylindrical shells with orthogonal stiffeners
Autorzy:
Wu, Yongfu
Zhao, Chen
Liang, Haofeng
Yao, Sishi
Xue, Jianghong
Xu, Peng
Powiązania:
https://bibliotekanauki.pl/articles/2086971.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
free vibration
laminated cylindrical shells
stiffener
energy method
Opis:
This paper proposes theoretical and numerical approaches to scrutinize the free vibration of orthogonal stiffened cylindrical shells. According to K´arman-Donnell shell theory, the total energy of the stiffened cylindrical shells is derived. Based on the principle of minimum potential energy, the eigenfunction related to the frequency is established and solved by developing a Matlab program. Analytical solutions of the natural frequency for free vibraion of the stiffened cylindrical shells are calculated and are verified against the finite element results from ABAQUS software. On account of the observations from the parametric study, an optimization scheme of the stiffeners is proposed.
Źródło:
Journal of Theoretical and Applied Mechanics; 2022, 60, 2; 239--252
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research on the Optical and EPR Spectral Data and the Local Structure for the Tetragonal $Nb^{4+}$ Center in Glasses
Autorzy:
Wu, Xiao-Xuan
Yu, Xin-Peng
Zheng, Wen-Chen
Powiązania:
https://bibliotekanauki.pl/articles/1402323.pdf
Data publikacji:
2015-07
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
76.30.He
71.70.Ch
78.40.Pg
78.55.Qr
Opis:
Two optical bands and four EPR (or spin-Hamiltonian) parameters (g factors $g_{∥}$, $g_{⊥}$ and hyperfine structure constants $A_{∥}$, $A_{⊥}$) of the tetragonally-compressed $Nb^{4+}$ octahedral center in glasses are calculated from two methods, the complete diagonalization (of energy matrix) method and the perturbation theory method. Both methods are founded on the two-spin-orbit-parameter model where both the contribution to the spectral data from the spin-orbit parameter of central $d^{n}$ ion and that of ligand ion via covalence effect are considered. The calculated results from both the complete diagonalization (of energy matrix) method and perturbation theory method show reasonable agreement with the experimental values. The signs and possible misprint for the observed hyperfine structure constants $A_{∥}$ and $A_{⊥}$ are suggested, and the local structure of the tetragonal $Nb^{4+}$ center in glasses due to the Jahn-Teller effect is gained from the calculations. The results are discussed.
Źródło:
Acta Physica Polonica A; 2015, 128, 1; 72-75
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Pressure-Dependent Plasticity Model for Polymer Bonded Explosives under Confined Conditions
Autorzy:
Wei, Qiang
Huang, Xi-cheng
Chen, Peng-wan
Liu, Rui
Powiązania:
https://bibliotekanauki.pl/articles/27787985.pdf
Data publikacji:
2021
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Przemysłu Organicznego
Tematy:
polymer bonded explosives
constitutive model
damage model
confining pressure
mechanical response
Opis:
The safety of explosives is closely related to the stress state of the explosives. Under some stress stimulation, explosives may detonate abnormally. It is of great significance to accurately describe the mechanical response of explosives for the safety evaluation of explosives. The mechanical properties of polymer bonded explosives (PBXs) strongly depend on pressure. In this study, the mechanical behaviour of PBXs under confined conditions was investigated. It was found that the stress-plastic strain response of a PBX under high confining pressures is a combination of the non-linear and linear hardening portions. However, the linear hardening portion has often been neglected in characterizing the mechanical behaviour of a PBX under such pressures. The Karagozian and Case (K&C) model was applied to characterize the mechanical behaviour of PBXs. The numerical results demonstrated that when the confining pressure was high, the K&C model could not adequately match the experimental data due to the limitation of the damage model. Therefore, a new damage model was developed by means of considering intragranular damage and transgranular damage. This modification made it possible to introduce a linear hardening process into the original K&C model. The method proposed to describe the stress-strain results under high confining pressures was to consider the stress-plastic strain curve, including the nonlinear and linear hardening portions. The damage evolution of the original K&C model and a linear hardening model were applied for the nonlinear and linear hardening portions respectively. The influence of the linear hardening model on the damage evolution of the original K&C model was included when describing the nonlinear hardening portion. A comparison between simulation and experiment showed that the modified K&C model could well describe the mechanical response of PBXs under different confining pressures.
Źródło:
Central European Journal of Energetic Materials; 2021, 18, 3; 339--368
1733-7178
Pojawia się w:
Central European Journal of Energetic Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study on Tensile Properties and Microstructures of Different Sites in Al-Si Alloy Casting Component
Autorzy:
Tao, Jianquan
Xiang, Lin
Chen, Xidong
Sun, Jipeng
Wang, Yanbin
Du, Chuanhang
Peng, Feifei
Gao, Shiqing
Chen, Qiang
Powiązania:
https://bibliotekanauki.pl/articles/27765052.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
ZL114A alloy
plaster-mold casting
tensile properties
microstructure
fracture
Opis:
The tensile properties and microstructures of ZL114A alloy component with a complex shape are investigated at room temperature and 200°C, using the tensile tests, scanning electron microscopy and electron backscattering diffraction. Both thin wall and thick structure exhibit excellent properties, of which max ultimate tensile strength and elongation at break reach 314 MPa and 2.5% at room temperature, respectively. The ultimate tensile strengths of thin wall are 40 MPa and 25 MPa greater than those of thick structure at room temperature and 200°C, respectively. Moreover, the eutectic Si phases of thin wall exhibit a predominantly spherical morphology while of the morphology of thick structure are rod-like, resulting in the different mechanical properties between thin wall and thick structure. The fracture morphologies of thin wall and thick structure are studied to explain the difference in performance between thin wall and thick structure.
Źródło:
Archives of Metallurgy and Materials; 2023, 68, 2; 585--589
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of preoxidation on copper flotation from copper-lead mixed concentrate
Autorzy:
Peng, Zeng
Haiyun, Xie
Yanling, Jin
Pei, Zhang
Jialing, Chen
Liu, Dianwen
Powiązania:
https://bibliotekanauki.pl/articles/24085956.pdf
Data publikacji:
2023
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
copper-lead mixed concentrate
peroxidation
separation of copper and lead
response surface methodology
Opis:
Flotation separation of galena and chalcopyrite is always a difficult problem in mineral processing. In this paper, the selective preoxidation of galena and chalcopyrite with sulfuric acid was developed, and then the two minerals were completely separated by flotation. The surface oxidation mechanism of galena and chalcopyrite with sulfuric acid was analyzed by Fourier transform infrared spectroscopy (FT-IR) and Atomic Force Microscopy (AFM), and the results showed that hydrophilic oxide film was formed on the galena surface, while the surface of chalcopyrite is still hydrophobic sulfide film, which led to the separation of the two minerals by flotation. In addition, the Response Surface Methodology (RSM) was used to analyze the influence of main preoxidation parameters on the flotation separation of copper-lead concentrate, and the parameters were further optimized, as follows: sulfuric acid concentration of 5.3 mol/L, oxidation temperature of 101.8 °C and time of 48.3 min. The mixed concentrate containing Cu 11.57% and Pb 16.75% was preoxidized under the above conditions, and the flotation separation verification results showed that Cu concentrate with Cu grade of 18.09% and recovery of 95.41%, and Pb concentrate with Pb grade of 44.96% and recovery of 95.94% was obtained respectively. This paper provides a new method of preoxidation combined flotation to achieve high-efficiency separation of copper-lead mixed concentrate.
Źródło:
Physicochemical Problems of Mineral Processing; 2023, 59, 2; art. no. 163253
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study on separation of fine-particle ilmenite and mechanism using flocculation flotation with sodium oleate and polyacrylamide
Autorzy:
Peng, Yang
Xiao, Junhui
Deng, Bing
Wang, Zhen
Liu, Nengyun
Yang, Daoguang
Ding, Wei
Chen, Tao
Wu, Qiang
Powiązania:
https://bibliotekanauki.pl/articles/1450088.pdf
Data publikacji:
2020
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
sodium oleate
polyacrylamide
synergistic effect
ilmenite
flocculation flotation
Opis:
In this paper, sodium oleate, polyacrylamide, soluble starch and sodium carboxymethyl cellulose were used as flocculants to study the flocculation and sedimentation behavior of microfine ilmenite. Sedimentation test shows that sodium oleate and polyacrylamide have good flocculation effect on ultrafine ilmenite. The flocculation rate of ilmenite can be further improved by the combination of sodium oleate and polyacrylamide. It was found that both flocculants could generate chemical adsorption with ilmenite surface, and they all react with $Fe^{3+}$ on ilmenite surface. However, sodium oleate reacts with $Fe^{3+}$ to form a water-insoluble iron oleate precipitate which coats the surface of the ilmenite and hinders the action of polyacrylamide and the remaining $Fe^{3+}$. This problem can be avoided by adding polyacrylamide followed by sodium oleate, and the flotation recovery can be increased significantly.
Źródło:
Physicochemical Problems of Mineral Processing; 2020, 56, 1; 161-172
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Electrostatic Hazards Assessment of Nitramine Explosives: Resistivity, Charge Accumulation and Discharge Sensitivity
Autorzy:
Peng, Q.
Cao, W.
Zhou, W.
He, Z.
Jiang, W.
Chen, W.
Powiązania:
https://bibliotekanauki.pl/articles/358757.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Przemysłu Organicznego
Tematy:
nitramine explosives
electrostatic hazards
resistivity
charging characteristics
electrostatic discharge sensitivity
Opis:
The electrostatic hazards of nitramine explosives (RDX, HMX) were assessed in this paper. The resistivities of different particle-size RDX and HMX were tested by a device designed and manufactured according to the standard ISO/IEC 80079-20-2:2016. This work shows that the resistivities of uncompacted RDX and HMX increase as the particle size decreases. Charging characteristics test experiments were also carried out using a so-called sieve method. Using this method, the influence of aperture size on charge accumulation of RDX was studied, and the characteristics of electrostatic accumulation of different particle-size RDX and HMX sieved with 50 mesh standard sieve were compared. The results show that the absolute value of the charge accumulation increases as the mesh number increases (i.e. the aperture size decreases), and increases as the particle size is decreased, indicating that nano-sized RDX and nano-sized HMX accumulate static electricity more easily than conventional micron-sized ones. Finally, the electrostatic discharge (ESD) sensitivity of nano-sized RDX and nano-sized HMX was investigated. Nano-sized nitramine explosives were found to have a higher ESD sensitivity than micron-sized ones.
Źródło:
Central European Journal of Energetic Materials; 2016, 13, 3; 755-769
1733-7178
Pojawia się w:
Central European Journal of Energetic Materials
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies