Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Chaberski, D." wg kryterium: Autor


Wyświetlanie 1-5 z 5
Tytuł:
Quantization error in time-to-digital converters
Autorzy:
Zaworski, Ł.
Chaberski, D.
Kowalski, M.
Zieliński, M.
Powiązania:
https://bibliotekanauki.pl/articles/221677.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
time interval measurement
time-to-digital converter
quantization error
averaging
Opis:
Methods of time interval measurement can be divided into asynchronous and synchronous approaches. It is well known that in asynchronous methods of time-interval measurement, uncertainty can be reduced by using statistical averaging. The motivation of this paper is an investigation of averaging in time interval measurements, especially in a synchronous measurement. In this article, authors are considering the method of averaging to reduce the influence of quantization error on measurement uncertainty in synchronous time-interval measurement systems, when dispersion of results, caused by noise is present. A mathematical model of averaging, which is followed by the results of numerical simulations of averaging of measurement series is presented. The analysis of results leads to the conclusion that in particular conditions the influence of the quantization error on measurement uncertainty can be minimized by statistical averaging, similar to asynchronous measurements.
Źródło:
Metrology and Measurement Systems; 2012, 19, 1; 115-122
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie fluktuacji czasu ustalania przerzutnika
Research of setup time fluctuation of the flip-flop
Autorzy:
Grzelak, S.
Zieliński, M.
Chaberski, D.
Wydźgowski, L.
Powiązania:
https://bibliotekanauki.pl/articles/151245.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
czas ustalania
metastabilność
struktura FPGA
pomiar odcinka czasowego
setup time
metastability
FPGA
time interval measurement
Opis:
Zjawisko metastabilności występujące w przerzutnikach podzielono na dwa różne efekty. Pierwszy dotyczy zwiększonego czasu propagacji, a drugi przypadkowości w ustalaniu stanu wyjściowego. Przedstawiono uogólniony model przerzutnika typu D wyzwalanego zboczem. Zaproponowano metodę pomiaru dodatkowego parametru zinterpretowanego jako poziom fluktuacji czasu ustalania, dla wprowadzonego modelu. Przeprowadzono pomiary przerzutników zaimplementowanych w strukturze FPGA wykonanej w technologii 180 nm. Wartość wprowadzonego parametru w modelu ma znaczenie w wysokorozdzielczej metrologii odcinków czasowych i może wpływać na sumaryczny błąd losowy mierzonego odcinka czasu.
The metastability effect is discussed in this paper as two separated effects. The first concerns the increase of the propagation time and the second concerns the random character of output states. The generalized model of the flip-flop was introduced. The measurements method of the setup time fluctuation is presented. The results of measurements for the flip-flops implemented in the FPGA structure are also discussed.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9 bis, 9 bis; 695-697
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparison of Interpolators Used for Time-Interval Measurement Systems Based on Multiple-Tapped Delay Line
Autorzy:
Chaberski, D.
Frankowski, R.
Gurski, M.
Zieliński, M.
Powiązania:
https://bibliotekanauki.pl/articles/221043.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
time interval
multiple-tapped delay line
quantization-and-nonlinearity minimization
FPGA
time-to-digital converter
Opis:
The paper describes the construction, operation and test results of three most popular interpolators from a viewpoint of time-interval (TI) measurement systems consisting of many tapped-delay lines (TDLs) and registering pulses of a wide-range changeable intensity. The comparison criteria include the maximum intensity of registered time stamps (TSs), the dependency of interpolator characteristic on the registered TSs’ intensity, the need of using either two counters or a mutually-complementing pair counter-register for extending a measurement range, the need of calculating offsets between TDL inputs and the dependency of a resolution increase on the number of used TDL segments. This work also contains conclusions about a range of applications, usefulness and methods of employing each described TI interpolator. The presented experimental results bring new facts that can be used by the designers who implement precise time delays in the field-programmable gate arrays (FPGA).
Źródło:
Metrology and Measurement Systems; 2017, 24, 2; 401-412
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A High-Speed Fully Digital Phase-Synchronizer Implemented in a Field Programmable Gate Array Device
Autorzy:
Frankowski, R.
Chaberski, D.
Kowalski, M.
Zieliński, M.
Powiązania:
https://bibliotekanauki.pl/articles/221125.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
phase synchronizer
delay line
coincidence counting
quantum information
time interval measurement
time-to-digital converters
field programmable gate array (FPGA)
Opis:
Most systems used in quantum physics experiments require the efficient and simultaneous recording different multi-photon coincidence detection events. In such experiments, the single-photon gated counting systems can be applicable. The main sources of errors in these systems are both instability of the clock source and their imperfect synchronization with the excitation source. Below, we propose a solution for improvement of the metrological parameters of such measuring systems. Thus, we designed a novel integrated circuit dedicated to registration of signals from a photon number resolving detectors including a phase synchronizer module. This paper presents the architecture of a high-resolution (~60 ps) digital phase synchronizer module cooperating with a multi-channel coincidence counter. The main characteristic feature of the presented system is its ability to fast synchronization (requiring only one clock period) with the measuring process. Therefore, it is designed to work with various excitation sources of a very wide frequency range. Implementation of the phase synchronizer module in an FPGA device enabled to reduce the synchronization error value from 2.857 ns to 214.8 ps.
Źródło:
Metrology and Measurement Systems; 2017, 24, 3; 537-550
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rejestrator kropel aerozolu wodnego wytwarzanego metodą wybuchową
The trap-box for collecting droplets of explosive formation water aerosol
Autorzy:
Śmigielski, G.
Lewandowski, D.
Chaberski, D.
Grzelak, S.
Dygdała, R.
Powiązania:
https://bibliotekanauki.pl/articles/155946.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomiar wielkości kropel
aerozol wodny
wybuchowe wytwarzanie aerozolu wodnego
measurement size of droplets
water aerosol
explosive formation of water aerosol
Opis:
Artykuł prezentuje budowę przyrządu służącego do przechwytywania kropel aerozolu wodnego wytwarzanego metodą wybuchową. Dotychczas nikt nie wykonywał tego typu pomiarów dla tak znacznej ilości rozpraszanej wody (1500 l). Zbudowany przyrząd umożliwia pośredni pomiar wielkości szybko poruszających się kropel aerozolu. Opracowano odporną na działanie wysokich ciśnień konstrukcję oraz oprogramowanie, które pozwala na zróżnicowany dobór parametrów pracy rejestratora.
This article presents the building of the instrument (Fig. 1, Fig. 2) used to collect droplets of explosive formation of water aerosol. Such a method of producing water aerosol consists in the explosion of the explosive charge put inside the water capsule [1] and is potentially applicable in the case of extinguishing fires [2]. The sizes of droplets are important when designing an efficient system [1, 2], and such information is lacking in scientific literature. Up to now measurement of explosive formation aerosol droplets' size has been investigated with much less scale [6]. Performing droplet size measurements can be challenging, in view of the short distance from the explosive center, its high speed (200 m/s) and ambient pressures from the explosion (registered about 40 kPa in distance of 5 m from the axis of the water-capsule). These reasons are major obstacles to use known instruments and measurement methods [3, 4]. In this work, an instrument has been presented in a form of a trap-box (Fig. 2) to indirect measure the sizes of the aerosol droplets. This article presents the mechanical construction of instruments, which is immune for high pressure and humidity of the air; its modes; method of measurement; analysis of metrological parameters of trap-box and exemplary results.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 12, 12; 1170-1173
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies