Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Casas, F." wg kryterium: Autor


Wyświetlanie 1-2 z 2
Tytuł:
Error estimates for the finite-element approximation of a semilinear elliptic control problem
Autorzy:
Casas, E.
Troeltzsch, F.
Powiązania:
https://bibliotekanauki.pl/articles/206743.pdf
Data publikacji:
2002
Wydawca:
Polska Akademia Nauk. Instytut Badań Systemowych PAN
Tematy:
aproksymacja numeryczna
metoda elementu skończonego
równanie eliptyczne półliniowe
sterowanie rozproszone
distributed control
error estimates
finite element method
numerical approximation
semilinear elliptic equation
Opis:
We consider the finite-element approximation of a distributed optimal control problem governed by a semilinear elliptic partial differential equation, where pointwise constraints on the control are given. We prove the existence of local approximate solutions converging to a given local reference solution. Moreover, we derive error estimates for local solutions in the maximum norm.
Źródło:
Control and Cybernetics; 2002, 31, 3; 695-712
0324-8569
Pojawia się w:
Control and Cybernetics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Use of ultrafiltration and nanofiltration processes for the elimination of three selected emerging contaminants: amitriptyline hydrochloride, methyl salicylate and 2-phenoxyethanol
Autorzy:
Benítez, F. J.
Real, F. J.
Acero, J. L.
Casas, F.
Powiązania:
https://bibliotekanauki.pl/articles/207379.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
COD
municipal wastewater treatment plants
water quality
filtration process
ChzT
miejskie oczyszczalnie ścieków
jakość wody
proces filtracji
Opis:
Three emerging contaminants: amitriptyline hydrochloride (AH), methyl salicylate (MS) and 2-phenoxyethanol (PE) were treated by means of filtration processes for their elimination from ultrapure (UP) water in a first stage, and from three water matrices (surface water from a reservoir, and two effluents from two municipal wastewater treatment plants) in a second stage. For this purpose, ultrafiltration and nanofiltration membranes were used in a cross-flow laboratory equipment. The permeate fluxes at the steady state were determined, and the resistances to the permeate flux were established. It was found that the inherent resistance of the clean membranes provided a much larger resistance than the fouling resistance. The retention coefficients for each individual contaminant were evaluated, as well as the retention coefficients referred to three water quality parameters: absorbance at 254 nm, COD and TOC. These parameters provide the effectiveness of the filtration processes for the elimination of the organic matter present in the selected water matrices.
Źródło:
Environment Protection Engineering; 2017, 43, 3; 125-141
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies