Microscopic evaluation of the manholes in selected sewerage pressure system
Autorzy:
Bogusławski, Bartosz
Głowacka, Anna
Rucińska, Teresa
Powiązania:
https://bibliotekanauki.pl/articles/396582.pdf
Data publikacji:
2019
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
hydrogen sulfide
biocorrosion
pressure sewage system
sulfate attack on concret
siarkowodór
biokorozja
kanalizacja ciśnieniowa
Opis:
The aim of the research was to determine changes in the elemental composition of concrete under the influence of exposure to hydrogen sulphide in the existing sewage system. The system operator pointed to significant problems with odours in this system. The research included a fragment of the pressure sewage system. The concentration of gases: hydrogen sulphide, ammonia and methane was measured in selected wells. High concentrations of hydrogen sulphide (over 200 ppm) were recorded in the studies. Concrete samples were taken from the internal walls of the well for testing. The samples were used for a microscopic analysis of their composition, using an electron microscope with an EDS attachment. Also, concrete samples from a new sewage well were tested to compare their elemental composition. Gas measurements confirmed the problem of odors, while the analysis of the elemental composition showed a significant proportion of sulphur(from 7.53% to 42.9%) on the surface of the well compared to the reference sample (0%).
Źródło:
Civil and Environmental Engineering Reports; 2019, 29, 2; 31-40
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Microscopic Evaluation of Concrete Samples from Manholes Exposed on Hydrogen Sulphide
Autorzy:
Bogusławski, Bartosz
Bering, Sławomira
Mazur, Jacek
Tarnowski, Krzysztof
Rucińska, Teresa
Głowacka, Anna
Powiązania:
https://bibliotekanauki.pl/articles/123945.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
hydrogen sulphide corrosion
biocorrosion
pressure sewage system
hydrogen sulphide
Opis:
The field test of the sewer system in a rural area was made. The results from two different pressure-gravity systems localized in two settlements were compared. The investigated sewer system operates in serial connection; the sewage from one settlement is pumped to the expansion well in the next one. In both systems, the high concentration of hydrogen sulfide, exceeding 200 ppm, and visible concrete wells corrosion effects were recorded. The samples of corroded concrete from the internal walls of the chosen wells were collected. The results of an electron microscope with the EDS attachment (Energy dispersive X-ray Spectroscopy) analysis showed a significant sulfur content in a concrete surface layer from 11.2% to 64.2% for the first system and from 7.53% to 42.9% for the second one. The exposure of concrete to high concentrations of hydrogen sulfide and relatively high content of sulfur on the surface of concrete might be a reason for hydrogen sulfide corrosion of concrete in the investigated systems.
Źródło:
Journal of Ecological Engineering; 2020, 21, 1; 188-194
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies