Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Bodzek, M." wg kryterium: Autor


Tytuł:
A multi-coil wireless power transfer (MC-WPT) system - analysis method and properties
Autorzy:
Kaczmarczyk, Z.
Bodzek, K.
Ruszczyk, A.
Kasprzak, M.
Domoracki, A.
Powiązania:
https://bibliotekanauki.pl/articles/114244.pdf
Data publikacji:
2015
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
wireless power transfer
magnetically coupled coils
resonant circuits
optimization
Opis:
The paper is devoted to some problems of multi-coil wireless power transfer (MC-WPT) systems. It is well known that the effective gap for MC-WPT systems can be extended for relatively long distances preserving high efficiency. The paper is organized as follows. In Section 2, the system is described by a matrix model. This model is prepared to determine system properties. In Section 3, the optimization procedure which allows improving the system performance at the desired operating point is introduced. Section 4 contains the results of experimental verification. Moreover, the paper presents an interesting phenomenon of the current unbalance among the system coils.
Źródło:
Measurement Automation Monitoring; 2015, 61, 10; 480-483
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of a Hybrid Uf-RO Process to Geothermal Water Desalination : Concentrate Disposal and Cost Analysis
Wykorzystanie hybrydowego procesuUF-RO w odsalaniu wód geotermalnych : utylizacja koncentratu i analiza kosztów
Autorzy:
Tomaszewska, B.
Pająk, L.
Bodzek, M
Powiązania:
https://bibliotekanauki.pl/articles/204638.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
desalination
geothermal water
reverse osmosis
costs analysis
concentrate disposal
odsalanie
wody geotermalne
odwrócona osmoza
analiza kosztów
utylizacja koncentratu
Opis:
Membrane-based water desalination processes and hybrid technologies are often considered as a technologically and economically viable alternative for desalination of geothermal waters. This has been confirmed by the results of pilot studies concerning the UF-RO desalination of geothermal waters extracted from various geological structures in Poland. The assessment of the feasibility of implementing the water desalination process analysed on an industrial scale is largely dependent on the method and possibility of disposing or utilising the concentrate. The analyses conducted in this respect have demonstrated that it is possible to use the solution obtained as a balneological product owing to its elevated metasilicic acid, fluorides and iodides ions content. Due to environmental considerations, injecting the concentrate back into the formation is the preferable solution. The energy efficiency and economic analysis conducted demonstrated that the cost effectiveness of implementing the UF-RO process in a geothermal system on an industrial scale largely depends on the factors related to its operation, including without limitation the amount of geothermal water extracted, water salinity, the absorption parameters of the wells used to inject water back into the formation, the scale of problems related to the disposal of cooled water, local demand for drinking and household water, etc. The decrease in the pressure required to inject water into the formation as well as the reduction in the stream of the water injected are among the key cost-effectiveness factors. Ensuring favourable desalinated water sale terms (price/quantity) is also a very important consideration owing to the electrical power required to conduct the UF-RO process.
Odsalanie wody z wykorzystaniem procesów membranowych oraz technologii hybrydowych rozważane jest jako technologiczna i ekonomiczna alternatywa dla klasycznych metod utylizacji wykorzystanych wód geotermalnych. Taką możliwość potwierdziły przeprowadzone badania pilotowe odsalania w systemie UF-RO wód geotermalnych eksploatowanych w obrębie różnych struktur geologicznych Polski. Ocena możliwości wdrożenia tych rozwiązań na skalę przemysłową, w dużej mierze zależy od kierunków i możliwości utylizacji/ zagospodarowania koncentratu. Przeprowadzone analizy w tym zakresie wykazały możliwość wykorzystania uzyskanego roztworu jako produktu o cechach balneologicznych, z uwagi na podwyższoną zawartość: kwasu metakrzemowego oraz jonów fluorkowych i jodkowych. Biorąc pod uwagę jednak względy środowiskowe, alternatywnym rozwiązaniem może być wtłaczanie koncentratu do górotworu. Przeprowadzona analiza energetyczna i ekonomiczna wykazała, iż opłacalność wdrożenia na skalę przemysłową procesu UF-RO w systemie geotermalnym w dużej mierze zależy od czynników związanych z jego pracą, a w szczególności: wielkości wydobycia wód geotermalnych, zasolenia wód, parametrów chłonnych otworów przeznaczonych do wtłaczania wód do górotworu, skali problemów związanych z utylizacją schłodzonych wód, lokalnego zapotrzebowania na wody pitne i gospodarcze i in. Kluczowa dla opłacalności tego procesu jest między innymi redukcja wymaganego ciśnienia przy wtłaczaniu wód do górotworu i redukcja wielkości strumienia zatłaczanych wód. Bardzo ważnym elementem jest również zapewnienie odpowiednich warunków zbytu odsolonych wód (cena/ilość) celem pokrycia zapotrzebowania na energię elektryczną wykorzystaną w procesie UF-RO.
Źródło:
Archives of Environmental Protection; 2014, 40, 3; 137-151
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of membrane techniques in the removal of inorganic impurities from water environment- state of art
Zastosowanie technik membranowych w usuwaniu zanieczyszczeń nieorganicznych ze środowiska wodnego - stan wiedzy
Autorzy:
Bodzek, M.
Konieczny, K.
Powiązania:
https://bibliotekanauki.pl/articles/401228.pdf
Data publikacji:
2011
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
procesy membranowe
usuwanie związków nieorganicznych
odsalanie i zmiękczanie wody
usuwanie anionów i metali
membrane processes
removal of inorganic
compounds
water desalination and softening
Opis:
Introduction and development of membrane technology in the production of drinking water, in the last 30 years, is considered as a significant step in the field of water treatment effectiveness, comparable with the introduction of sand filters at the beginning of 20 age. The special role played the high- and low- pressure-driven membrane processes as well as electrodialysis. Desalination of seawater and brackish groundwater is often the way to obtaining drinking water. Significant improvements in technology and design of reverse osmosis, the availability of alternative energy sources, the possibility of pretreatment and applied materials have caused the process to become environmentally-friendly source of fresh water in many regions of the world, particularly in those where their sources are limited. In the 1980s increased interest of nan filtration and to some extent the reverse osmosis as the methods of water softening, while in the 1990s. they start to be applied to remove micro-pollutants, also inorganic. To remove nitrate ions and fluoride, boron and metals (Fe, Mn and heavy metals) is successfully applied reverse osmosis, nan filtration and electro dialysis, as well as bioreactors and ultrafiltration integrated with coagulation and oxidation.
Wprowadzenie i rozwój technik membranowych w produkcji wody do picia, w ostatnich 30. latach, jest uważane jako znaczący krok w dziedzinie skuteczności uzdatniania wody, porównywalny z wprowadzeniem filtrów piaskowych na początku 20. wieku. Szczególną rolę odegrały w tym zakresie wysoko- jak i niskociśnieniowe procesy membranowe oraz elektrodializa. Odsalanie wody morskiej i zasolonych wód podziemnych jest częstym sposobem otrzymywania wody do picia. Znaczne ulepszenia w technologii i projektowaniu procesu odwróconej osmozy, dostępność alternatywnych źródeł energii, możliwości wstępnego oczyszczania oraz stosowanych materiałów spowodowały, że proces stał się przyjaznym ekologicznie źródłem wody słodkiej w wielu regionach świata, szczególnie w tych, gdzie ich źródła są ograniczone. W latach 80. wzrosło zainteresowanie nanofiltracją i w pewnym zakresie odwróconą osmozą jako metodami zmiękczania wody, natomiast w latach 90. zaczęto je stosować do usuwania mikrozanieczyszczeń, w tym nieorganicznych. Do usuwania jonów azotanowych i fluorkowych, boru oraz metali (Fe, Mn i metale ciężkie) z powodzeniem stosuje się odwróconą osmozę, nanofiltrację i elektrodializę, jak również bioreaktory membranowe oraz ultrafiltrację wspomaganą koagulacją i utlenieniem.
Źródło:
Inżynieria Ekologiczna; 2011, 26; 18-36
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania wpływu kwasów tłuszczowych i steroli na skuteczność oczyszczania ścieków osadem czynnym w układzie porcjowym
Effect of fatty acids and sterols on the efficiency of wastewater treatment by the activated sludge process in a batch system
Autorzy:
Łobos-Moysa, E.
Dudziak, M.
Bodzek, M.
Powiązania:
https://bibliotekanauki.pl/articles/237291.pdf
Data publikacji:
2010
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
oczyszczanie ścieków
proces tlenowy
osad czynny
oleje jadalne
kwasy tłuszczowe
sterole
wastewater treatment
aerobic process
activated sludge
edible oil
fatty acids
sterols
Opis:
Doświadczenia przeprowadzono w układzie porcjowym, z użyciem mieszanej populacji osadu czynnego z oczyszczalni ścieków komunalnych. Skuteczność biodegradacji składników ścieków modelowych i rzeczywistych określono na podstawie zmian zawartości zanieczyszczeń specyficznych, tj. kwasów tłuszczowych nienasyconych (linolowego - C18:2 i oleinowego - C18:1) i nasyconych (palmitynowego - C16:0) oraz steroli (stigmasterolu, -sitosterolu i betuliny). Stwierdzono całkowite usunięcie kwasu linolowego z obu rodzajów ścieków. Pozostałe zanieczyszczenia były usuwane w różnym stopniu, np. kwas oleinowy w zakresie 68÷93% (ścieki modelowe) i 90÷91% (ścieki komunalne). Wyjątek stanowił kwas palmitynowy, który podczas biodegradacji ścieków modelowych bez dodatku oleju został usunięty tylko w 32÷44%. Różnica w skuteczności usuwania tych zanieczyszczeń może wynikać z faktu, iż nienasycone kwasy tłuszczowe łatwo ulegają utlenieniu (wraz ze wzrostem ilości wiązań podwójnych). Stwierdzono również, iż skuteczność biodegradacji była zależna od początkowej zawartości kwasów tłuszczowych oraz od obciążenia osadu czynnego ładunkiem tych zanieczyszczeń. W przypadku steroli, które występowały w znacznie mniejszych ilościach niż kwasy tłuszczowe, nie stwierdzono takiej zależności. Wydaje się, że głównym mechanizmem ich usuwania była adsorpcja i biokumulacja.
The experiments were conducted in a batch system, with a mixed microbial population of the activated sludge obtained from a municipal sewage treatment plant. The extent of biodegradation for the polluting species occurring both in the model and real waste-waters was established taking into account the variations in the content of specific pollutants, i.e. unsaturated fatty acids (linoleic - C18:2 and oleinic - C18:1), saturated fatty acid (palmitic - C16:0) and sterols (stigmasterol, [beta]-sitosterol and betuline). The study produced the following findings. Removal of linoleic acid was complete with both types of wastewater. As for the other pollutants, differences were observed in the removal patterns between the two wastewater types: e.g., for oleinic acid the efficiency of removal varied from 68 to 93% in the case of the model wastewater, and from 90 to 91% in the case of the municipal sewage. Palmitic acid was an exception: its removal achieved during biodegradation of the model wastewater with no oil additive only varied between 32 and 44%. The difference in the efficiency of removal can be attributed to the readiness of unsaturated acids to undergo oxidation with the increase in the number of double bonds. The extent of biodegradation was also found to depend on the initial concentrations of the fatty acids and on the load of pollutants received by the activated sludge. In the case of sterols, whose concentrations were noticeably lower than those of fatty acids, no such relation was found to occur. Seemingly, the principal mechanism governing the removal of sterols involved adsorption and bio-accumulation.
Źródło:
Ochrona Środowiska; 2010, 32, 2; 53-56
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania wpływu oleju roślinnego na skuteczność oczyszczania ścieków osadem czynnym
Effect of vegetable oil on the efficiency of wastewater treatment by the activated sludge method
Autorzy:
Łobos-Moysa, E.
Bodzek, M.
Kopytiuk, M.
Mateja, M.
Powiązania:
https://bibliotekanauki.pl/articles/237634.pdf
Data publikacji:
2008
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
oczyszczanie ścieków
osad czynny
olej roślinny
wastewater treatment
activated sludge
vegetable oil
Opis:
Praca zawiera wyniki badań nad wpływem spożywczego oleju roślinnego na skuteczność biologicznego oczyszczania ścieków metodą osadu czynnego. Badania przeprowadzono w warunkach tlenowych w układach porcjowym i przepływowym, przy obciążeniu (suchej masy) osadu czynnego ładunkiem BZT5 w zakresie 0,03÷0,25 gO2/gźd. Osad czynny pobrano z oczyszczalni ścieków komunalnych znajdującej się w województwie śląskim. W badaniach wykorzystano ścieki modelowe (na bazie wzbogaconego bulionu) oraz ścieki rzeczywiste pochodzące z oczyszczalni komunalnej. Do obu rodzajów ścieków wprowadzono olej rzepakowy w postaci emulsji. Badania wykazały zmniejszenie skuteczności oczyszczania ścieków zawierających olej, niezależnie od sposobu prowadzania procesu. Poddając biodegradacji ścieki modelowe bez oleju w obu układach uzyskano zmniejszenie wartości ChZT o 93-95%, a w przypadku ścieków komunalnych o 89-95%. Wprowadzenie oleju roślinnego do ścieków zmniejszyło skuteczność oczyszczania odpowiednio do 86-92% i 80-85%. Również OWO był usuwany z mniejszą skutecznością, najczęściej poniżej 90%. W przypadku BZT5 stwierdzono zmniejszenie skuteczności procesu oczyszczania ścieków tylko w układzie przepływowym. Podczas eksploatacji oczyszczalni ścieków w takich warunkach (np. nagły zrzut ścieków zaolejonych) oleje, które nie uległy biodegradacji lub produkty ich biodegradacji przedostaną się do odbiornika naturalnego. Stwierdzono, że oceniając proces biologicznego oczyszczania ścieków zawierających oleje czy tłuszcze należy również analizować zanieczyszczenia specyficzne pochodzące od tych produktów spożywczych (np. sterole czy wyższe kwasy tłuszczowe), aby określić wpływ tych zanieczyszczeń na proces oczyszczania ścieków osadem czynnym oraz na biodegradację samych olejów.
The paper addresses the problem of how the presence of edible vegetable oil in the wastewater affects the biological treatment process involving activated sludge. The experiments were conducted under aerobic conditions in a batch reactor and a flow reactor, at a BOD5 loading of the activated sludge (dry solids) varying from 0.03 to 0.25 gO2/gźd. Sludge samples were collected at a municipal sewage treatment plant in the Silesian District. The water samples being treated contained model sewage (prepared on the basis of enriched broth) and actual sewage from the municipal sewage treatment plant mentioned. All the samples were added rapeseed oil in the form of emulsion. The experiments have revealed a reduction in the efficiency of treatment when rapeseed oil was present in the samples, regardless of the method with which the process was conducted. Biodegradation of the sewage where rapeseed oil was absent produced a COD removal efficiency of 93 to 95% and 89 to 95% for the model sewage and actual sewage, respectively, both in the batch and in the flow system. Upon addition of the vegetable oil, the efficiency of COD removal was lower and totalled 86 to 92% and 80 to 85%, respectively. The extent of reduction in TOC was also found to be lower in the presence of the oil, and in most instances failed to exceed 90%. As for BOD5, the removal efficiency was lower only when the process was conducted in the flow reactor. There is a real risk that during operation of the sewage treatment plant, under conditions of an emergency discharge of oil-contaminated wastewater, the non-biodegraded oils or the products of their biodegradation will enter the natural recipient. Thus, when assessing the biological treatment of wastewaters that contain oils or fats, it is necessary to take into account the pollutants specific to these food products (e.g. sterols or fatty acids), in order to determine the effect of the pollutants on the course of the activated sludge process and on the biodegradation of the oils.
Źródło:
Ochrona Środowiska; 2008, 30, 4; 35-38
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania zawartości ksenoestrogenów w wodzie metodą ekstrakcji sorpcyjnej
Analyzing the content of xenoestrogens in water by sorptive extraction
Autorzy:
Dudziak, M.
Bodzek, M.
Powiązania:
https://bibliotekanauki.pl/articles/236516.pdf
Data publikacji:
2009
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
ekstrakcja sorpcyjna
GC-MS
ksenoestrogeny
oczyszczanie wody
xenoestrogens
water treatment
SBSE
Opis:
Przedstawiono badania zawartości ksenoestrogenów w wodzie z wykorzystaniem mało znanej metody ekstrakcji sorpcyjnej (SBSE) oraz analizy GC/MS. Z grupy ksenoestrogenów do badań wybrano 4-tert-oktylofenol, 4-nonylofenol i bisfenol A. Do ekstrakcji sorpcyjnej zaproponowano pręt z polidimetylosiloksanu o długości 2 cm. Badane związki upochodniono w wodzie do pochodnych acylowych z wykorzystaniem bezwodnika kwasu octowego. Do uwolnienia ksenoestrogenów z elementu sorpcyjnego wykorzystano desorpcję do niewielkiej ilości rozpuszczalnika organicznego (LD - liquid desorption) w polu ultradźwiękowym. Wydajność ekstrakcji ksenoestrogenów w przypadku wody wodociągowej i powierzchniowej, w zakresie stężeń 40÷200 ng/cm3, była większy niż 60%. Precyzja oznaczeń ilościowych metody nie przekraczała 11%, a granica detekcji wynosiła 1 ng/cm3 w przypadku 4-tert-oktylofenolu i bisfenolu A oraz 5 ng/cm3 w przypadku 4-nonylofenolu. Opisany sposób uwolnienia zaadsorbowanych związków z elementu sorpcyjnego jest konkurencyjny w stosunku do techniki SBSE z desorpcją termiczną, wykorzystywanej w laboratoriach analizy próbek środowiskowych.
The content of xenoestrogens in water was determined using the rather poorly known Stir Bar Sorptive Extraction (SBSE) technique, as well as GC/MS analysis. Of the xenoestrogen group the following compounds were selected for the study: 4-tert-octylphenol, 4-nonylphenol and bisphenol A. For soptive extraction the use of a polydimethyloxosilane bar (2 cm in length) was proposed. Using acetic acid anhydride, the compounds were derivatized in water to acyl derivatives. In order to release the xenoestrogens from the sorptive element, use was made of desorption to a small amount of an organic solvent (liquid desorption, LD) in an ultrasonic field. For tap and surface waters, at the concentration of xenoestrogens ranging between 40 and 200 ng/cm3, the efficiency of extraction exceeded 60%. The accuracy of the quantitative determinations performed with this method was lower than 11%, the limits of detection being 1 ng/cm3 for 4-tert-octylphenol and bisphenol A, and 5 ng/cm3 for 4-nonylphenol. The method of releasing the adsorbed compounds from the sorptive element in the way described above is competitive with the SBSE technique which involves thermal desorption and is used in laboratories for environmental analysis.
Źródło:
Ochrona Środowiska; 2009, 31, 1; 9-14
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie wpływu właściwości wody na intensywność i mechanizm zjawiska foulingu w procesie ultrafiltracji
Influence of water properties on fouling ratio and fouling mechanism during ultrafiltration
Autorzy:
Płatkowska-Siwiec, A.
Bodzek, M.
Powiązania:
https://bibliotekanauki.pl/articles/127252.pdf
Data publikacji:
2011
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
ultrafiltracja
NOM
fouling
pH
siła jonowa
ultrafiltration
ionic strength
Opis:
Alternatywną metodą oczyszczania i uzdatniania wody w stosunku do metod klasycznych są procesy membranowe, którym towarzyszy nieodłącznie zjawisko foulingu, związane z obniżeniem wydajności i z akumulacją substancji organicznych bądź nieorganicznych na powierzchni membrany. W artykule omówiono wyniki badań wpływu właściwości wód (pH, rodzaj substancji organicznych, siła jonowa) na intensywność foulingu, wyrażoną za pomocą jednostkowego indeksu foulingu UMFI (Unified Membrane Fouling Index), i na mechanizm zjawiska.
Membrane techniques are an alternative water treatment method for classical processes. However, mostly their capacity and membrane lifetime are limited by the phenomenon called fouling, ie the accumulation of organic and/or inorganic substances on the surface and into the pores of the membrane. The results of the study presenting the dependence of water properties such as pH, kind of organic matters and ionic strength on membrane fouling are discussed in this article. Unified Modified Fouling Index (UMFI) was used to describe intensity of fouling. Also the influence of water properties on fouling mechanism is shown.
Źródło:
Proceedings of ECOpole; 2011, 5, 1; 275-279
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fluorki w środowisku wodnym – zagrożenia i metody usuwania
Fluorine in the water environment - hazards and removal methods
Autorzy:
Bodzek, M.
Konieczny, K.
Powiązania:
https://bibliotekanauki.pl/articles/297154.pdf
Data publikacji:
2018
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
water treatment
fluoride removal
coagulation
precipitation
adsorption
membrane processes
uzdatnianie wody
usuwanie fluorków
koagulacja
wytrącanie
adsorpcja
procesy membranowe
Opis:
High fluorine concentrations in aquatic environment, even above 30 mg/L, are often detected in many parts of the world. Due to fluorine effects on health, World Health Organization (WHO) as well as national health authorities have established its maximum permissible concentration in drinking water at the level of 1.5 mg/L. This review article aims to provide detail information on researchers’ efforts in the field of fluorides removal during potable water production. The contaminant elimination methods have been broadly divided in three sections, i.e. coagulation/precipitation, adsorption and membrane techniques. Both, precipitation with the use of calcium salts or coagulation with aluminum sulphate and ferric salts followed by sedimentation are used for fluorine removal. In electrocoagulation, a coagulant is generated in situ by means of oxidation of anode usually made of aluminum or iron. The removal of fluorides from water and wastewater can be performed with the use of many different types of adsorbents, which are either applied already at industrial scale or still tested in the laboratory or pilot scale. The adsorption on activated aluminum oxide is already a common technology of fluorine removal from water and wastewater, and it is also indicated as the one of the best available technique (BAT) in this field. However, the adsorbent price is relatively high, while its efficiency mostly depends on pH and co-ions presence. Recently, a lot of effort has been devoted to develop an effective method of aluminum oxide modification with the use of metals’ oxides impregnation, which reveal significant defluoridation efficiency. The applicability of carbon based sorbents is less efficient than of aluminum compounds, hence a number of studies on modification of carbon based materials towards defluoridation improvement are carried out. The special attention is dedicated to carbon nanotubes. Among many natural materials, which are usable to fluorine adsorption, many different types of clays and minerals have been tested. Biosorbents, especially modified chitosan, also offer promising results in fluorine removal process. Additionally, a group of waste materials, which contain metal oxides, have also been examined to fluorides concentration decrease in contaminated aqueous streams, and those can be considered as alternative cheap sorbents. Synthetic layered double hydroxides (LDHs), hydrocalcite like compounds and nanosorbents have also gained a lot of attention as potential fluorine adsorbent, as they reveal high affinity toward the contaminant. Among membrane techniques reverse osmosis, nanofiltration, ultrafiltration in integrated systems, electrodialysis and Donnan dialysis have been discussed. The most important benefits offered by membrane processes are very high removal efficiency (up to 98%), single stage treatment, simultaneous water disinfection and low requirement for additional chemicals. However, the removal of other anions present in treated water is a serious disadvantage of those techniques, as it results in the need of water remineralization to assure the proper quality of finally produced potable water. Additionally, membrane processes are quite expensive due to relatively high initial concentrated solution containing fluorine may become a significant problem.
Występowanie fluorków (F-) w wodach naturalnych jest związane z ich obecnością w skorupie ziemskiej, jak również aktywnością przemysłową człowieka. O ile obecność jonów F- w wodzie do picia w ilości 0,5÷0,7 mg/l zabezpiecza przed próchnicą zębów, o tyle ich nadmiar jest uważany za poważny problem zdrowotny. Regularne spożywanie wysoce fluorowanej wody, zawierającej 1,5÷4 mg F/l, wywołuje wiele chorób związanych z tkanką kostną (fluoroza, artretyzm i osteoporoza), chorobę Alzheimera, utratę pamięci i inne neurologiczne dolegliwości. Według World Health Organization, a także polskich przepisów, maksymalne stężenie fluorków w wodzie do picia nie może przekraczać 1,5 mg/l, a rekomendowany jest zakres 0,5÷1 mg/l. Opracowano szereg metod usuwania fluorków, które można podzielić na trzy grupy procesów: koagulacja i wytrącanie, membranowe techniki separacji oraz adsorpcja/wymiana jonowa.
Źródło:
Inżynieria i Ochrona Środowiska; 2018, 21, 2; 113-141
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fouling membran półprzepuszczalnych podczas oczyszczania wody metodą ultra- i mikrofiltracji - przegląd piśmiennictwa
The fouling of semi-permeable membranes during water treatment by use of UF/MF proces - review
Autorzy:
Bodzek, M.
Płatkowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/296721.pdf
Data publikacji:
2009
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
NOM
fouling
membrany
HPSEC
SEM/AFM
FTIR
koagulacja
PAC
membranes
coagulation
Opis:
Procesom membranowym uzdatniania wody i oczyszczania ścieków towarzyszy nieodłącznie zjawisko zmniejszania wydajności i żywotności membran zwane foulingiem. Pierwszym krokiem do ograniczenia foulingu jest poznanie natury tego zjawiska. Pozwalają na to dostępne techniki analityczne, takie jak: SEM, AFM, FTIR, HPSEC, analiza OWO, ASA, pomiar kąta zwilżenia oraz potencjału elektrokinetycznego membran czy też frakcjonowanie na żywicach XAD8/4. Stopień foulingu powodowanego przez NOM uzależniony jest m.in. od siły jonowej oraz pH. Zależy on w dużej mierze od właściwości filtrowanej wody, w tym hydrofilowości/hydrofobowości jej składników. Duża część badaczy obarcza frakcję hydrofobową odpowiedzialnością za fouling. Dla procesów niskociśnieniowych zaobserwowano wpływ rozmiaru cząstek filtrowanej frakcji (im mniejsze, tym większy obserwowany spadek strumienia oraz opór filtracji) na zjawisko foulingu. Zidentyfikowano 4 kategorie NOM, które uważane są za silne foulanty, a mianowicie białka, aminocukry, polisacharydy i związki poli(hydroksy-aromatyczne). Znaczenia ma również rodzaj membrany. W zdecydowanej większości prac zaobserwowano większą tendencję do foulingu w przypadku membran hydrofobowych niż hydrofilowych, co tłumaczono adsorpcją ujemnie naładowanych grup funkcyjnych NOM na dodatnio naładowanych powierzchniach membrany. Obecnie stosowane są różne procesy wstępnego przygotowania nadawy, mające na celu zwiększenie jakości wody i/lub wydajności membran. Koagulacja oraz adsorpcja na węglu aktywnym są polecane przy minimalizacji foulingu związanego z dużymi stężeniami poli(hydroksy-aromatów), proces utlenienia natomiast jest zalecany do zmniejszania foulingu powodowanego polisacharydami.
During membrane water and wastewater processes reduction of capacity and membranes lifetime can be observed. Those phenomena are caused by membrane fouling. To limit the influence of fouling on the efficiency of membrane processes detailed recognition of its nature is required. This can be done using available analytical technologies like: electron microscopy (SEM, AFM), infrared spectroscopy (FTIR), high performance size exclusion chromatography (HPSEC), TOC analysis, atomic absorption spectroscopy (AAS), measurement of contact angle and zeta potential or fractionation on XAD8/4 resins. The influence of fouling caused by NOM mainly depends on ionic strength and pH, but also on properties of filtrated water, including hydophobicity/hydrophilicity of its components. Resent scientific reports suggest that the hydrophobic water fraction has a significant impact on fouling. Size of molecules of filtrated fraction is responsible for fouling occurring fouling during low-pressure membrane processes (the smallest size of molecules the highest flux decline). 4 categories of NOM, which are considered to be strong foulants, were identified. They include: proteins, aminosugars, polysaccharides and poly(hydroxy-aromatics). The membrane composing material also has a meaning. Hydrophobic membranes seem to have greater ability to fouling than hydrophilic ones. It can be explained by the fact, that the positively charged membrane surface tends to adsorb negatively charged functional groups of NOM. Nowadays different water pretreatment processes are applied. Their aim is to improve water quality and/or membrane capacity. Fouling caused by poly(hydroxyl-amines) can be minimized by coagulation or adsorption on activated carbon, while oxidation reduces the fouling induced by polysacharides.
Źródło:
Inżynieria i Ochrona Środowiska; 2009, 12, 1; 5-24
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fouling of membranes during ultrafiltration of surface water (NOM)
Fouling membran podczas ultrafiltracji wody powierzchniowej
Autorzy:
Bodzek, M.
Płatkowska, A.
Rajca, M.
Komosiński, K.
Powiązania:
https://bibliotekanauki.pl/articles/388487.pdf
Data publikacji:
2009
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
ultrafiltracja
koagulacja
naturalne substancje organiczne (NOM)
hydrofilowość
hydrofobowość
wysokosprawna chromatografia wykluczenia objętościowego (HPSEC)
ultrafiltration
coagulation
natural organic matter (NOM)
hydrophobicity/hydrophilicity
chromatography - HPSEC
Opis:
The results of studies focused on membrane fouling during surface water treatment by use, of ultrafiltration, coagulation/sedimentation/ultrafiltration and in-line coagulation/ultrafiltration processes were presented. Medium- and low-molecular organic compounds (NOM) that are not rejecting in UF/MF process tan be remove by use of pre-coagulation. The surface water used in the tests coming from Smieszek Lake located in Zory (Silesia province, Poland) contained organic matter of about 14 mg/dm3 TOC. Aluminum su1fate was used in both coagula-tions (4.9 mg Al/dm3, pH = 7.0). Molecular mass distribution in feed water and permeates was determined by use of high performance size exclusion (HPSEC). Applications of coagulation/sedimentation/ultrafiltration and in-line coagulation/ultrafiltration processes in water treatment allowed to get better quality of permeate than in ultrafiltration process alone. The smallest flux decline and the highest membrane capacity were observed in in-line coagulation/ultrafiltration process. Molecular weight distribution showed that integrated/hybrid processes allow rejecting molecules > 10 kDa in the highest degree. These molecules were responsible for membrane blocking as they deposit on surface and/or in membrane pores. The paper also presents impact hydrophobicity/hydrophilicity of NOM on UF membrane fouling. From isolated fractions the hydrophobic fraction of NOM caused the largest flux decline, while hydrophilic fraction - the smallest. Transphilic fraction pollutants were removed in highest grade. They might have a significant influence on membrane fouling.
Przedstawiono wyniki badania intensywności foulingu membran podczas oczyszczania wody naturalnej w procesie jednostkowym ultrafiltracji, zintegrowanym koagulacji klasycznej/ultrafiltracji oraz hybrydowym koagulacji in-line/ultrafiltracji zawierającej naturalne substancje organiczne (NOM). Wstępna koagulacja umożliwia usunięcie średnio- i małomolekularnych związków organicznych, które w samodzielnym procesie UF/MF nie są usuwane. W badaniach stosowano wodę powierzchniową z jeziora Śmieszek, zlokalizowanego na terenie miasta Żory, charakteryzującą się zawartością związków organicznych na poziomie ok. 14 mg TOC/dm3. W procesie koagula-cji zastosowano siarczan glinu (4,9 mg Al/dm3, pH = 7,0). W strumieniach powstających podczas procesu oczyszczania wyznaczono rozkład mas molekularnych za pomocą HPSEC. Zastosowanie układu hybrydowego/zintegrowanego do oczyszczania wody zawierającej substancje organiczne pozwoliło na uzyskanie permeatu lepszej jakości niż w bezpośredniej UF. Ponadto proces koagulacji in-line/UF w największym stopniu zmniejszył fouling membrany UF i w konsekwencji polepszył jej wydajność. Rozkład mas molekularnych wykazał, iż w procesach zintegrowanych/hybrydowych w największym stopniu zostały zatrzymane molekuły o rozmiarach> 10kDa. Molekuły te są odpowiedzialne za zjawisko blokowania membran, osadzając się na powierzchni i/lub w porach. Określano również wpływ hydrofilowości/hydrofobowości substancji organicznej na zjawisko blokowania membran ultrafiltracyjnych. Spośród wyizolowanych trakcji NOM trakcja hydrofobowa NOM spowodowała największy spadek strumienia permeatu, podczas gdy hydrofilowa najmniejszy. W największym stopniu zatrzymane zostały zanieczyszczenia trakcji transfilowej, które mogą znacząco przyczynić się do zjawiska foulingu.
Źródło:
Ecological Chemistry and Engineering. A; 2009, 16, 1-2; 107-119
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of natural organic matter (NOM) on fouling and ultrafiltration membranes properties - AFM analysis
Wpływ naturalnych substancji organicznych na fouling oraz właściwości membran ultrafiltracyjnych - analiza AFM
Autorzy:
Płatkowska-Siwiec, A.
Bodzek, M.
Powiązania:
https://bibliotekanauki.pl/articles/127269.pdf
Data publikacji:
2012
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
fouling
ultrafiltration
natural organic matter
atomic force microscopy (AFM)
ultrafiltracja
naturalne substancje organiczne
mikroskop sił atomowych
Opis:
Low pressure membrane processes ie microfiltration and ultrafiltration are widely applied in water and wastewater treatment. The main exploitation problem connected with those technologies is the decrease of membrane capacity during the process caused by blocking of membrane pores with organic and inorganic substance (so-called fouling). The performance of atomic force microscopy analysis enables quantitative determination of membranes roughness and allows to characterize membrane surface before and after fouling. The paper discuss results of filtration of three surface waters differ in properties, mainly in specific UV absorbance (SUVA254).
Niskociśnieniowe techniki membranowe, ultrafiltracja i mikrofiltracja, stosowane są do oczyszczania i uzdatniania wody. Głównym problem eksploatacyjnym jest zmniejszanie wydajności membrany w trakcie procesu, związane z blokowaniem porów przez substancje organiczne i nieorganiczne (tzw. fouling). Analiza mikroskopem sił atomowych (AFM) umożliwia ilościowe określenie chropowatości powierzchni membrany, co pozwala scharakteryzować powierzchnię membran przed i po foulingu. W artykule przedstawiono wyniki filtracji trzech wód powierzchniowych różniących się głównie specyficzną absorbancją w nadfiolecie (SUVA254).
Źródło:
Proceedings of ECOpole; 2012, 6, 1; 43-49
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of Natural Organic Matter on Fouling and Ultrafiltration Membranes Properties – AFM analysis
Wpływ naturalnych substancji organicznych na fouling oraz właściwości membran ultrafiltracyjnych – analiza AFM
Autorzy:
Płatkowska-Siwiec, A.
Bodzek, M.
Powiązania:
https://bibliotekanauki.pl/articles/387738.pdf
Data publikacji:
2012
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
fouling
ultrafiltration
natural organic matter
atomic force microscopy (AFM)
ultrafiltracja
naturalne substancje organiczne
mikroskop sił atomowych
Opis:
Low pressure membrane processes ie microfiltration and ultrafiltration are widely applied in water and wastewater treatment. The main exploitation problem connected with those technologies is the decrease of membrane capacity during the process caused by blocking of membrane pores with organic and inorganic substance (so-called fouling). The performance of atomic force microscopy analysis enables quantitative determination of membranes roughness and allows to characterize membrane surface before and after fouling. The paper discuss results of filtration of three surface waters differ in properties, mainly in specific UV absorbance (SUVA254).
Niskociśnieniowe techniki membranowe, ultrafiltracja i mikrofiltracja, stosowane są do oczyszczania i uzdatniania wody. Głównym problem eksploatacyjnym jest zmniejszanie wydajności membrany w trakcie procesu, związane z blokowaniem porów przez substancje organiczne i nieorganiczne (tzw. fouling). Analiza mikroskopem sił atomowych (AFM) umożliwia ilościowe określenie chropowatości powierzchni membrany, co pozwala scharakteryzować powierzchnię membran przed i po foulingu. W artykule przedstawiono wyniki filtracji trzech wód powierzchniowych różniących się głównie specyficzną absorbancją w nadfiolecie (SUVA254).
Źródło:
Ecological Chemistry and Engineering. A; 2012, 19, 12; 1561-1570
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of Water Properties on Fouling Intensity and Fouling Mechanism during Ultrafiltration
Badanie wpływu właściwości wody na intensywność i mechanizm zjawiska foulingu w procesie ultrafiltracji
Autorzy:
Płatkowska-Siwiec, A.
Bodzek, M.
Powiązania:
https://bibliotekanauki.pl/articles/387976.pdf
Data publikacji:
2012
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
ultrafiltracja
NOM
fouling
pH
siła jonowa
ultrafiltration
ionic strength
Opis:
Membrane techniques are an alternative water treatment method for classical processes. However, mostly their capacity and membrane lifetime are limited by the phenomenon called fouling, ie the accumulation of organic and/or inorganic substances on the surface and into the pores of the membrane. The results of the study presenting the dependence of water properties such as pH, kind of organic matters and ionic strength on membrane fouling are discussed in this article. Unified Modified Fouling Index (UMFI) was used to describe intensity of fouling. Also the influence of water properties on fouling mechanism are shown.
Alternatywną metodą oczyszczania i uzdatniania wody w stosunku do metod klasycznych są procesy membranowe, którym towarzyszy nieodłącznie zjawisko foulingu, związane z obniżeniem wydajności i z akumulacją substancji organicznej bądź nieorganicznej na powierzchni membrany. W artykule omówiono wyniki badań wpływu właściwości wód (pH, rodzaj substancji organicznej, siła jonowa) na intensywność foulingu, wyrażoną za pomocą jednostkowego indeksu foulingu UMFI (Unified Membrane Fouling Index) i na mechanizm zjawiska.
Źródło:
Ecological Chemistry and Engineering. A; 2012, 19, 6; 629-638
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kinetyka degradacji kwasów fulwowych w zintegrowanym procesie fotoutlenianie-ultrafiltracja
Kinetics of fulvic acid degradation in the integrated process photooxidation-ultrafiltration
Autorzy:
Rajca, M.
Bodzek, M.
Cichy, J.
Powiązania:
https://bibliotekanauki.pl/articles/237389.pdf
Data publikacji:
2011
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
kwasy fulwowe
oczyszczanie wody
fotokataliza
ultrafiltracja
kataliza
fotoliza
model kinetyczny
fulvic acids
water treatment
photocatalysis
ultrafiltration
catalysis
photolysis
kinetic model
Opis:
Przedstawiono wyniki badań skuteczności usuwania kwasów fulwowych z modelowych roztworów wodnych w procesach katalizy, fotolizy i fotokatalizy oraz w procesie zintegrowanym fotokataliza-ultrafiltracja. Badania przeprowadzono w reaktorze Heraeus, w którym oczyszczano wodę zawierającą kwasy fulwowe w ilości ok. 10 g/m3. Jako fotokatalizator wykorzystano dwutlenek tytanu. Badano wpływ pH (3,5, 7,0 i 10,0) oraz dawki katalizatora (100÷600 gTiO2/m3) na skuteczność utleniania kwasów fulwowych, mierzoną zawartością rozpuszczonego węgla organicznego i absorbancją w nadfiolecie (lambda=254 nm). Wykazano skuteczność procesu fotokatalizy w usuwaniu kwasów fulowych z wody oraz przydatność membrany ultrafiltracyjnej do odzyskiwania katalizatora użytego w procesie fotokatalizy. Wyznaczono wartości stałej szybkości reakcji i czasu połowicznego rozkładu kwasów fulwowych według modelu kinetycznego opartego na reakcji pierwszego rzędu, a także zależność stałej szybkości od pH i ilości fotokatalizatora w środowisku reakcji. Uzyskane wyniki pozwoliły w dokładny sposób określić przebieg fotodegradacji kwasów fulwowych w wodzie.
In this study, fulvic acids were removed from model solutions by catalysis, photolysis and photocatalysis, as well as in the integrated process of photocatalysis and ultrafiltration. Experiments were carried out in the Heraeus reactor, where model water of an approximately 10 g/m3 content of fulvic acids was treated. Titanium dioxide was used as a photocatalyst. The efficiency of fulvic acid oxidation, measured in terms of dissolved organic carbon content and UV absorbance (lambdha=254 nm), was related to the pH of the water (3.5, 7.0 and 10.0) and to the catalyst dose applied (100 to 600 gTiO2/m3). The results substantiated the efficiency of the photocatalysis process at fulvic acid removal from water and the usefulness of the ultrafiltration membrane in the recovery of the catalyst being used in the photocatalytic process. The values of the reaction rate constant and the half-time of fulvic acid degradation were determined using a kinetic model based on a first-order reaction. Established were also the relations between rate constant, pH and photocatalyst concentration in the reaction environment. The results obtained make it possible to precisely describe the progression of fulvic acid photodegradation.
Źródło:
Ochrona Środowiska; 2011, 33, 3; 63-66
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelowanie wydajności ultrafiltracji i mikrofiltracji w oczyszczaniu wód naturalnych w układzie hybrydowym z koagulacją
Modeling the efficiency of ultrafiltration and microfiltration in natural water treatment
Autorzy:
Rajca, M.
Bodzek, M.
Konieczny, K.
Powiązania:
https://bibliotekanauki.pl/articles/237460.pdf
Data publikacji:
2008
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
oczyszczanie wody
ultrafiltracja
mikrofiltracja
koagulacja
proces hybrydowy
water treatment
ultrafiltration
microfiltration
coagulation
hybrid system
Opis:
W pracy przedstawiono wyniki badań wydajności ultrafiltracji (UF), mikrofiltracji (MF) i procesu hybrydowego koagulacja-sedymentacja-UF/MF w procesie oczyszczania wody powierzchniowej z rzeki Czarna Przemsza. Do prognozowania wydajności UF/MF zastosowano model w procesie niestacjonarnym (relaksacyjny) oparty o zmianę objętościowego strumienia permeatu w czasie z wyznaczeniem stałej czasowej (to) oraz model oporowy oparty o analizę oporów, wywołanych wzajemnym oddziaływaniem membrana-zanieczyszczenia w wodzie z wyznaczeniem stałej tRo. W doświadczeniach użyto modułów membranowych z kapilarnymi membranami ultrafiltracyjnymi z polieterosulfonu (PES) oraz mikrofiltracyjnymi z polipropylenu (PP). Stwierdzono, że analizowane modele dobrze opisują proces bezpośredniej UF/MF oraz badany układ hybrydowy, a wartości obliczone pozostają w zgodności z danymi doświadczalnymi.
The efficiency of ultrafiltration/microfiltration (UF/MF) and of the hybrid system coagulation-sedimentation-UF/MF as unit processes in the treatment of natural riverine water (Czarna Przemsza) was made subject to analysis. UF/MF efficiency was predicted using two models: a model in a nonstationary process (a relaxation model) that described time-related changes in the volume flux of the permeate and determined the time constant to, as well as a resistance model that analyzed the resistance induced by the interaction of the membrane with water pollutants, and determined the time constant tRo. The experiments were conducted using modules of capillary polyethersulfone (PES) ultrafiltration and polypropylene (PP) microfiltration membranes. It has been found that the models characterize adequately both the process of direct UF/MF and the hybrid system, and that the calculated values are consistent with the experimental ones.
Źródło:
Ochrona Środowiska; 2008, 30, 1; 13-20
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies