Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Bilgic, E." wg kryterium: Autor


Wyświetlanie 1-8 z 8
Tytuł:
Determination of Pulse Width and Pulse Amplitude Characteristics of Materials Used in Pendulum Type Shock Calibration Device
Autorzy:
Bilgic, E.
Powiązania:
https://bibliotekanauki.pl/articles/1031327.pdf
Data publikacji:
2017-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
06.20.Dk
06.20.fb
Opis:
Calibration of shock and vibration transducers is performed by using the methods described in ISO 16063-13 and 16063-22 standards, at primary and secondary levels respectively. At secondary level, the devices, generating mechanical shock, are pendulum shock calibrator, dropball shock calibrator, pneumatically operated piston shock calibrator and Hopkinson bar shock calibrator. The main parameters and requirements of the shock calibrator devices, named here, are also given in ISO 16063-22 standard. Pulse width and pulse amplitude are the important parameters in calibration of the shock and vibration transducers. Pulse width and shape depend on the material properties. In this paper the determination of pulse width and pulse amplitude characteristics of materials used in pendulum type shock calibration device, designed in TUBİTAK UME, is presented.
Źródło:
Acta Physica Polonica A; 2017, 132, 3; 857-860
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effects of Waveform Model on Sensitivity Values of Transducers Used in Mechanical Dynamic Measurements
Autorzy:
Bilgiç, E.
Durgut, Y.
Powiązania:
https://bibliotekanauki.pl/articles/1402011.pdf
Data publikacji:
2015-08
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
06.20.dk
Opis:
Dynamic calibration of the pressure transducers and accelerometers are carried out by applying dynamic mechanical inputs to them. Determination of those transducers' sensitivities, defined as the ratio of electrical output of the transducer to the mechanical input, is an important task for calibration laboratories. Data obtained during calibration are processed in order to have the peak values of the input and output signals which are sampled by data acquisition boards. Different approximations are made such as fitting the data in the range of 90% of the maximum value for parabola or half-sine waveform. It is clear that waveform model used and also the resolution and the sampling rate of the data acquisition boards have effects on the accuracy of the sensitivity of the transducer. For the investigation, the electrical output signal of the transducer corresponding to the mechanical input is recorded and simulated with different resolutions and sampling rates. Those data are processed for the waveforms of half-sine, parabola, Gaussian distribution. The effect of the waveform model of the input quantities on the dynamic sensitivity is discussed in this paper.
Źródło:
Acta Physica Polonica A; 2015, 128, 2B; B-267-B-270
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of Uncertainty Contributions of Measurement Surface and Number of Microphone Positions in Determination of Sound Power Levels
Autorzy:
Bilgic, E.
Mutaf, H.
Kirbas, C.
Sadikoglu, E.
Powiązania:
https://bibliotekanauki.pl/articles/1031890.pdf
Data publikacji:
2017-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
06.20.Dk
06.20.fb
Opis:
Sound power level of a noise source is determined by means of sound pressure level or sound intensity level measurements performed in accordance to relevant ISO standards. The determination of sound power level according to ISO 3744, 3745 and 3746 standards is used for free field or for approximated free field conditions. Kinds of measurement surfaces, enveloping the noise source, number of microphones and their positions over the measurement surface are stated in the applied ISO standard. The effects of measurement surface and number of microphone positions on the determination of sound power level were investigated theoretically. As a measurement surface; hemisphere, parallelepiped rectangular box and cylindrical surfaces were selected. Key and additional microphone positions were taken into account in the calculations as well. Sound pressure levels of a commercially available reference sound source were measured in hemi-anechoic room using FFT with 4 Hz steps and also at 1/1, 1/3, 1/12 and 1/24 octave bands for all surfaces defined in ISO 3744 and 3746 standards. Sound power level, directivity index and uncertainty contributions resulting from measurement surfaces and number of microphone positions were calculated by using data obtained in measurements. In this paper the theoretical and experimental results are presented.
Źródło:
Acta Physica Polonica A; 2017, 132, 3; 642-649
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nanomechanical behaviour and surface roughness of new generation dental fissure sealants
Autorzy:
Arslanoğlu, Z.
Altan, H.
Kale, E.
Bılgıç, F.
Şahin, O.
Powiązania:
https://bibliotekanauki.pl/articles/1068318.pdf
Data publikacji:
2016-07
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
87.85.J-
62.20.-x
Opis:
The aim of this study is the comparative evaluation of surface roughness, elastic modulus and hardness values of some new generation fissure sealants using nanoindentation method and triboindenter. In this study, we have tested five different materials of dental fissure sealant in five groups with six specimens in each. Tested specimens were prepared from the following materials; Fuji Triage as a glass ionomer, Glass Seal as a glass carbomer, Ultra Seal XT Hydro, Teethmate F-1 and Defence Chroma as three resin composites. In the study, Hysitron Triboindenter TI 950 machine was used for nanohardness measurements. This machine has load resolution of less than 1 nN and displacement resolution of 0.04 nm. Data were statistically analysed using one-way analysis of variance (ANOVA) and Kolmogorov-Smirnov Z tests. Hardness values of Fuji Triage, Glass Seal, Ultra Seal XT Hydro were fairly close. Same situation was seen between Teethmate F-1 and Defence Chroma. However, hardness values of the Teethmate F-1 and Defence Chroma was lower than in other examined materials. We can also say that the Defence Chroma has the lowest elastic modulus and Fuji Triage has the highest one among the examined materials. Surface of Teethmate F-1 was the roughest. On the other hand, Ultra Seal XT Hydro has the smoothest surface.
Źródło:
Acta Physica Polonica A; 2016, 130, 1; 388-393
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effects of Third-generation LED LCU on Nanomechanical Properties of Orthodontic Adhesives
Autorzy:
Bilgic, F.
Altan, H.
Akinci Sözer, Ö.
Arslanoglu, Z.
Kale, E.
Özarslan, S.
Powiązania:
https://bibliotekanauki.pl/articles/1031919.pdf
Data publikacji:
2017-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
62.20.-x
62.20.Qp
Opis:
The aim of this study was to compare the hardness and elastic modulus of orthodontic adhesives cured with different light-curing units, based on light-emitting diodes. Standardized samples of orthodontic adhesives, Transbond™ XT, Opal® Bond™ and Light Bond™ were prepared in cylinder blocks and cured for three seconds with Valo Ortho LED (Ultradent Products, South Jordan, Utah) and Valo LED High-Power Mode. After grinding and polishing, specimens were stored in distilled water at 37°C for one day. Specimens were investigated using nanoindenter. Employment of Valo Ortho unit has resulted in significantly higher elastic modules for Transbond™ XT (p=0.041). The highest nanohardness and elastic modules were measured for Transbond™ XT cured with Valo Ortho (9.47 GPa; 81.85 GPa, respectively) and lowest for Opal® Bond™ for both Valo Ortho (0.44 GPa; 14.52 GPa, respectively) and Valo High-Power groups (0.44 GPa; 11.84 GPa, respectively).
Źródło:
Acta Physica Polonica A; 2017, 132, 3; 697-701
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nanomechanical comparison of commonly used dental crown cements to a newly developed one
Autorzy:
Kale, E.
Arslanoğlu, Z.
Altan, H.
Bılgıç, F.
Tuzlali, M.
Köroğlu, A.
Özarslan, S.
Powiązania:
https://bibliotekanauki.pl/articles/1054940.pdf
Data publikacji:
2017-09
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
62.20.-x
62.20.Qp
62.20.de
Opis:
The main goal of nanoindentation tests is to obtain elastic modulus and hardness of the specimen material from load-displacement measurements. With this study, it was aimed to establish a quantitative relationship between the nanomechanical properties of commonly used dental cements in comparison to a newly developed crown cement and to predict its performance potential. Nanomechanical properties of polycarboxylate cement (PCC), glass-ionomer cement (GIC), dual-cure self-adhesive cement (SAC) and a newly developed glass-carbomer cement (GCC) were investigated by nanoindentation tests. All samples were fabricated according to their respective manufacturer's instructions. Available damage on the surface due to manipulation was removed by grinding with 1200, 2400 and 4000 grit sandpaper, and then polishing on 6, 3, and 1 μm diamond-lap-wheel was performed. Nano-mechanical measurements were done using nanoindenter machine with resolution less than 1 nN and displacement resolution of 0.04 nm. Berkovich diamond indenter tip was used for the nanoindentation tests. For each indentation, a set of nanoindentation tests at least on 6 different locations per specimen surface were performed to obtain more representative mean results. Indentation test load-displacement curves were analysed using Oliver-Pharr method, and one-way ANOVA or Kruskal-Wallis test, following Kolmogorov-Smirnov and Shapiro-Wilk, was used to compare the results. Nanohardness (H_{nano}) values were 0.52± 0.25, 0.45± 0.18, 1.03± 0.82 and 0.43± 0.18 GPa for GIC, GCC, PCC, and SAC, respectively. Reduced elastic modulus (E_{r}) values were 9.51± 6.17, 11.77± 5.04, 27.37± 20.61, 10.33± 5.08 GPa for GIC, GCC, PCC, and SAC, respectively. There was no statistical difference between the tested materials. PCC was the hardest, and GIC was the least hard material, whereas the newly developed GCC was the second, in terms of H_{nano}, before SAC. PCC also had the highest E_{r} mean, compared to the other dental crown cements, suggesting lower elastic properties. SAC was more elastic than GCC and less elastic than GIC. GCC had the second highest E_{r}, standing closer to SAC and GIC. Within the limitations of the current study, it can be concluded that the newly developed glass-carbomer cement is comparable to the other tested commonly used dental crown cements, regarding H_{nano} and E_{r}.
Źródło:
Acta Physica Polonica A; 2017, 132, 3; 954-958
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nanomechanical properties of different dental restorative materials
Autorzy:
Altan, H.
Bilgic, F.
Arslanoglu, Z.
Kale, E.
Köroğlu Kale, A.
Altan, A.
Sahin, O.
Powiązania:
https://bibliotekanauki.pl/articles/1068227.pdf
Data publikacji:
2016-07
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
62.20.-x
62.20.Qp
Opis:
The aim of this study is to determine the hardness and roughness of glass ionomer cement, glass carbomer, and compomer by nanoindentation. Three different dental restorative materials: glass ionomer cement, glass carbomer cement, and compomer were used. Disc specimens (10 mm × 1 mm) were prepared from each material using teflon mold. All specimens were light cured according to the manufacturer's instructions. The specimens were then mounted in polyacrilic resin. After grinding and polishing the specimens were stored in distilled water at 37°C for 1 day. The specimens were investigated using nanoindenter. The highest nanohardness was measured for glass ionomer cement and the lowest for glass carbomer. Regarding roughness, glass ionomer cement and compomer showed the highest mean values. Glass ionomer cement and compomer exhibited similar nanomechanical properties. Glass carbomer had superior ability to be polished up.
Źródło:
Acta Physica Polonica A; 2016, 130, 1; 394-396
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hydroxyapatite Synthesis from Fish Bones: Atlantic Salmon (Salmon Salar)
Autorzy:
Komur, B.
Altun, E.
Aydogdu, M.
Bilgiç, D.
Gokce, H.
Ekren, N.
Salman, S.
Inan, A.
Oktar, F.
Gunduz, O.
Powiązania:
https://bibliotekanauki.pl/articles/1032056.pdf
Data publikacji:
2017-03
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
87.85.jj
81.05.-t
Opis:
Production of the bioceramics on the market is presently conducted from typical precipitation method by using reagent grade raw chemicals or through calcination of natural sources like animal bones (especially bovine bone) and fish bones. Usually fish bones were damped near or in the water sources, which can lead to serious environmental pollution. Those were regarded as a trash, even though they still bear economic value, including conjugates. In this study bones of Atlantic Salmon (Salmo salar) were used as a bioceramic material source. Bones of Atlantic Salmon were collected from Besiktas Fish Market. Those were cleaned from possible flesh with reagent grade NaOH. Cleaned parts were washed with demineralized water very neatly. Dry fish bones were calcinated at 850°C for 4 hours. The obtained hydroxyapatite material was characterized with scanning electron microscopy and X-ray diffraction methods. It was found that the bioceramic material consisted of hydroxyapatite and various related phases. Scanning electron microscopy studies have revealed nano-structured bioceramic particles. The aim of this study is to obtain nano-structured bioceramics from bones of Atlantic Salmon in an environmentally friendly and economic way.
Źródło:
Acta Physica Polonica A; 2017, 131, 3; 400-402
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies