Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Bielecki, J." wg kryterium: Autor


Tytuł:
Applications of the Cracow X-Ray Microprobe in Tomography
Autorzy:
Bielecki, J.
Bożek, S.
Lekki, J.
Stachura, Z.
Kwiatek, W.
Powiązania:
https://bibliotekanauki.pl/articles/1809463.pdf
Data publikacji:
2009-02
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
87.59.-e
87.57.Q-
Opis:
A nuclear microprobe at the IFJ PAN in Cracow has found numerous applications in different fields of research, mostly in biophysics, medical sciences, geology, and material research. In order to extend the research possibilities, a new X-ray microprobe was constructed. This new microprobe consists of three experimental lines dedicated to: (i) X-ray irradiation of biological specimens, (ii) elemental analysis of samples by micro X-ray fluorescence or total reflection X-ray fluorescence methods and (iii) computer microtomography. In this paper the computer microtomography line was described. The line consists of an open type Hamamatsu L9191 X-ray tube with microfocusing to about 2 μm, a high resolution X-ray sensitive CCD camera, and a precise goniometer composed of six piezoelectric motors. Depending on the required X-ray energy, the Hamamatsu tube is used with Ti, Mo, Ag, or W targets. A small focus size and short focus-to-object distance enable to obtain images of samples with a magnification of more than 1000× and resolution of the order of 2 μm. The computer microtomography measurements are carried out using home developed codes combined with commercial software. Details of the microprobe construction and preliminary results of the computer microtomography experiments are presented.
Źródło:
Acta Physica Polonica A; 2009, 115, 2; 537-541
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostic systems for the nuclear fusion and plasma research in the PF-24 plasma focus laboratory at the IFJ PAN
Autorzy:
Marciniak, Ł.
Wójcik-Gargula, A.
Kulińska, A.
Bielecki, J.
Wiącek, U.
Powiązania:
https://bibliotekanauki.pl/articles/147710.pdf
Data publikacji:
2016
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
diagnostics for DD fusion products
fast neutron sources
plasma diagnostics
plasma focus
plasma imaging
Opis:
This paper presents a set of diagnostics dedicated to PF-24 – new medium size – plasma focus (PF) device built and operated at the Institute of Nuclear Physics Polish Academy of Sciences (IFJ PAN). The PF-24 can operate at energy level up to 93 kJ and charging voltage up to 40 kV. Each condenser is connected with a specially designed spark gap with a very small jitter, which ensures a high efficiency and a low current rise time. The working parameters of PF-24 generator make it a suitable tool for testing new detection systems to be used in fusion research. Four types of such detection systems are presented in this article: three diagnostic systems used to measure electric quantities (Rogowski coil, magnetic probe, capacitance probe), neutron counter based on beryllium activation, fast neutron pinhole camera based on small-area BCF-12 plastic scintillation detectors and high-speed four-frame soft X-ray camera with microchannel plate.
Źródło:
Nukleonika; 2016, 61, 4; 413-418
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Preliminary Investigations of Elemental Content, Microporosity, and Specific Surface Area of Porous Rocks Using PIXE and X-ray Microtomography Techniques
Autorzy:
Bielecki, J.
Bożek, S.
Dutkiewicz, E.
Hajduk, R.
Jarzyna, J.
Lekki, J.
Pieprzyca, T.
Stachura, Z.
Szklarz, Z.
Kwiatek, W.
Powiązania:
https://bibliotekanauki.pl/articles/1490118.pdf
Data publikacji:
2012-02
Wydawca:
Polska Akademia Nauk. Instytut Fizyki PAN
Tematy:
81.70.Tx
91.65.-n
47.56.+r
Opis:
Determination of physical properties of porous geological materials is of great importance for oil industry. The knowledge of rocks properties is usually obtained from porosity studies such as pore size distribution, specific surface area determination, and hydrodynamic permeability calculations. This study describes determination of elemental composition and measurements of the particular physical properties of geological samples (porous sandstone rocks) by means of the nuclear and X-ray microprobes at the Institute of Nuclear Physics, Polish Academy of Sciences in Kraków, Poland. The special emphasis has been put on the computed microtomography method. Measurements have been carried out in close cooperation with Department of Geophysics, FGGEP AGH in Kraków, Poland. Chemical composition of the Rotliegend sandstone rock samples (few millimeters diameter), extracted from a borehole at 2679.6 m, 2741.4 m and 2742.4 m depth have been investigated using the 2.2 MeV proton beam (proton induced X-ray emission technique). Next, measurements of the porosity and the specific surface area of the pore space have been carried out using the X-ray microtomography technique. Basing on microtomographic data obtained with the high spatial resolution, simulations of the fluid dynamic in the void space of porous media have been carried out. Lattice Boltzmann method in the 3DQ19 geometrical model has been used in order to predict the hydraulic permeability of the media. In order to avoid viscosity-permeability dependence the multiple-relaxation-time model with half-way bounce back boundary conditions has been used. Computing power-consuming processing has been performed with the use of modern grid infrastructure.
Źródło:
Acta Physica Polonica A; 2012, 121, 2; 474-479
0587-4246
1898-794X
Pojawia się w:
Acta Physica Polonica A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biological diversity of leeches [Clitellata: Hirudinida] based on characteristics of the karyotype
Autorzy:
Cichocka, J.
Bielecki, A.
Powiązania:
https://bibliotekanauki.pl/articles/838553.pdf
Data publikacji:
2008
Wydawca:
Polskie Towarzystwo Parazytologiczne
Tematy:
leech
Clitellata
Hirudinida
internal morphology
external morphology
karyology
biodiversity
cytogenetic analysis
Źródło:
Annals of Parasitology; 2008, 54, 4; 309-314
0043-5163
Pojawia się w:
Annals of Parasitology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stanowisko do badań czułości widmowej detektorów promieniowania o długości fali 13,5 nm
Laboratory setup for measurement of detector responsivity at the wavelength of 13.5 nm
Autorzy:
Mikołajczyk, J.
Bielecki, Z.
Powiązania:
https://bibliotekanauki.pl/articles/158057.pdf
Data publikacji:
2007
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
detekcja promieniowania optycznego
wzorcowanie detektorów
detection of optical signal
detectors calibration
Opis:
W pracy omówiono stanowisko do badań czułości widmowej detektorów promieniowania z zakresu skrajnego nadfioletu. Po raz pierwszy w badaniach tych zastosowano laserowo-plazmowe źródło promieniowania z tarczą gazową. Istotnym elementem tego stanowiska jest dzielnik optyczny z układem zwierciadeł wielowarstwowych. Umożliwia on przeprowadzenie porównawczych pomiarów energii promieniowania za pomocą badanego detektora i wzorcowego miernika. Ogranicza to w znacznym stopniu wpływ niestabilności źródła promieniowania oraz zmianę warunków pomiarowych na dokładność procedury. W pracy przedstawiono wyniki badań poszczególnych elementów zaprojektowanego stanowiska. Dotyczą one wyznaczenia stabilności i wydajności źródła, charakterystyk parametrów zastosowanych układów optycznych oraz właściwości opracowanego dzielnika wiązki. Jednocześnie wyznaczono niepewność pomiarów czułości badanych detektorów za pomocą przyrządu E-Mon i wzorcowego detektora typu AXUV100 firmy National Radation Detectors Inc.
The paper presents a laboratory setup used for a calibration of EUV radiation detectors. For the first time, the laser-plasa source with gas puff target has been applied in such type of measuring procedure. The setup also used an optical beam splitter consisted of two Mo/Si multilayer mirrors. The splitter makes it possible to take comparative measurements by a tested detector and a model energy meter. The instabilities of the source intensity and measurement conditions were minimized in this way. The results of elements investigations of the position were presented. Measurements of the stability and energy efficiency of the radiation source were taken. The features of the beam splitters were determined. The uncertainty of the measuring procedure of detector responsivity at the position was characterized by calibrated E-Mon meter and photodiode model AXUV. A substantial improvement in the calibration systems is demonstrated.
Źródło:
Pomiary Automatyka Kontrola; 2007, R. 53, nr 9 bis, 9 bis; 285-288
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary energii promieniowania skrajnego nadfioletu
Energy measurement of extreme ultraviolet radiation
Autorzy:
Mikołajczyk, J.
Bielecki, Z.
Powiązania:
https://bibliotekanauki.pl/articles/327398.pdf
Data publikacji:
2006
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
optoelektronika
detekcja sygnałów optycznych
pomiar energii
promieniowanie EUV
nanolitografia
optoelectronics
detection of optical signals
energy measurement
EUV radiation
nanolithography
Opis:
W pracy omówiono system detekcji promieniowania skrajnego nadfioletu. Umożliwia on pomiar energii impulsów promieniowania w zakresie długości fal (13,5 š 0,5) nm. Przeprowadzone analizy i badania miały na celu określenie możliwości odniesienia wyników uzyskanych w tym zakresie długości fal do pasma (13,5 š 0,13) nm. W pracy zaprezentowano wyniki pomiaru widma promieniowania emitowanego ze źródła laserowo-plazmowego z ksenonową tarczą gazową dla różnych warunków wytwarzania plazmy. Na podstawie rezultatów otrzymanych za pomocą wzorcowego przyrządu E-Mon wyznaczono wartość tzw. skalibrowanej czułości widmowej systemu, która umożliwia odniesienie wyników pomiarów do pasma (13,5 š 0,13) nm.
The paper presents the IOE detection system for energy measurement of EUV radiation. The system measures energy of radiation pulses within the wavelength range of (13,5 š 0,5) nm. The described analyses and experiments determine possibilities of reference of results obtained from the system to the spectral range of (13,5 š 0,13) nm. The changes of radiation spectrum emitted from a laser-plasma source with xenon gas-puff target are presented. The results obtained from the standard E-Mon meter make it possible to determine a calibrated sensitivity of the IOE detection system within the wavelength range of (13,5 š 0,13) nm.
Źródło:
Diagnostyka; 2006, 3(39); 155-160
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biological diversity of leeches [Clitellata: Hirudinida] based on characteristics of the karyotype
Autorzy:
Cichocka, J.
Bielecki, A.
Powiązania:
https://bibliotekanauki.pl/articles/2143806.pdf
Data publikacji:
2008
Wydawca:
Polskie Towarzystwo Parazytologiczne
Tematy:
leech
Clitellata
Hirudinida
internal morphology
external morphology
karyology
biodiversity
cytogenetic analysis
Opis:
The majority of studies on leeches are related to: internal and external morphology. Fewer molecular research projects focus on molecular studies and karyology. The latter are needed to explain the evolutionary and systematic issues. Karyotypes for 22 species of Hirudinida have hitherto been determined, including: 8 species belonging to the Glossiphoniidae family, 3 species of Piscicolidae, 7 of Erpobdellidae, 1 of Haemopidae and 3 of Hirudinidae. The chromosome number vary among individual groups of leeches. Within Glossiphoniidae the chromosome diploid number ranges from 14 to 32, in Piscicolidae from 20 to 32, in Erpobdelliformes from 16 to 22, and in Hirudiniformes from 24 to 28. The karyological analyses were used to show phylogenetic relations between main groups of Hirudinida, and the diploid number of 16 was suggested to be a primitive value. This number tends to increase as the evolution progresses. The phylogeny scheme of leeches proposed by Mann shows the Glossiphoniidae as primitive to the Piscicolidae, and Hirudinidae as giving rise to the Haemopidae and Erpobdellidae. Those hypotheses are herewith confronted with morphological, molecular, karyological, ecological and behavioral data.
Źródło:
Wiadomości Parazytologiczne; 2008, 54, 4; 309-314
0043-5163
Pojawia się w:
Wiadomości Parazytologiczne
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Operative treatment of pressure ulcers using pedicled flaps
Autorzy:
Bielecki, M.
Bielecki, P.
Żebrowski, P.
Misiak, B.
Lewko, J.
Powiązania:
https://bibliotekanauki.pl/articles/1918770.pdf
Data publikacji:
2018
Wydawca:
Uniwersytet Medyczny w Białymstoku
Tematy:
Surgically treated pressure ulcers
lower back pressure ulcers
ischial pressure ulcers
heel pressure ulcers
pediculate pieces
Opis:
Purpose: To present the results of surgical treatment concerning pressure ulcers. Materials and methods: All patients underwent surgical treatment at the Orthopedics and Traumatology Clinic from 1997 to 2016. One operator performed the procedures. A total of 28 pressure ulcers were operated (25 patients). The clinical material consisted of 15 pressure ulcers located in the lower back area, six pressure ulcers located in the ischial area, three pressure ulcers located in the trochanteric area and four pressure ulcers located in the heel area. Results: One conducted the result evaluation based on the criteria of complications proposed by Seiler. In case of all surgically treated patients, pressure ulcers appeared after 2-5 weeks after the surgery. One patient experienced hematoma below the slide piece. One could observe seroma in case of 5 patients. In this situation, it was required to apply a local postoperative puncture. Four patients experienced marginal skin necrosis (2 of them required resection of dead skin edges in operating block conditions which were later re-stitched using “side to side” technique). During the 3-year follow-up, there was no recurrence of operated pressure ulcers. Conclusions: Deep septic pressure ulcers, according to the division introduced by Seiler, connected with bone infection require the application of muscular-skin pieces. This procedure is aimed at improving local tissue blood supply. Proper preoperative preparation of the patient, careful planning of the surgery and suitable postoperative treatment of the patient are as significant as the surgery itself.
Źródło:
Progress in Health Sciences; 2018, 8(2); 105-111
2083-1617
Pojawia się w:
Progress in Health Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies