Training neural networks with a hybrid differential evolution algorithm
Uczenie sieci neuronowych hybrydowym algorytmem opartym na differential evolution
Autorzy:
Bandurski, K.
Kwedlo, W.
Powiązania:
https://bibliotekanauki.pl/articles/341051.pdf
Data publikacji:
2009
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
sieci neuronowe
differential evolution
gradienty sprzężone
minima lokalne
neural networks
conjugate gradients
local minima
Opis:
A new hybrid method for feed forward neural network training, which combines differential evolution algorithm with a gradient-based approach is proposed. In the method, after each generation of differential evolution, a number of iterations of the conjugate gradient optimization algorithm is applied to each new solution created by the mutation and crossover operators. The experimental results show, that in comparison to the standard differential evolution the hybrid algorithm converges faster. Although this convergence is slower than that of classical gradient based methods, the hybrid algorithm has significantly better capability of avoiding local optima.
W artykule przedstawiono nową, hybrydową metodę uczenia sieci neuronowych, łączącą w sobie algorytm Differential Evolution z podejściem gradientowym. W nowej metodzie po każdej generacji algorytmu Differential Evolution, każde nowe rozwiązanie, powstałe w wyniu działania operatorów krzyżowania i mutacji, poddawane jest kilku iteracjom algorytmu optymalizacji wykorzystującego metodę gradientów sprzężonych.Wyniki eksperymentów wskazują, że nowy, hybrydowy algorytm ma szybszą zbieżność niż standardowy algorytm Differential Evolution. Mimo, iż zbieżność ta jest wolniejsza, niż w przypadku klasycznych metod gradientowych, algorytm hybrydowy potrafi znacznie lepiej unikać minimów lokalnych.
Źródło:
Zeszyty Naukowe Politechniki Białostockiej. Informatyka; 2009, 4; 5-17
1644-0331
Pojawia się w:
Zeszyty Naukowe Politechniki Białostockiej. Informatyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ użytkowania na parametry komfortu w energooszczędnym domu drewnianym DomTrzon – wyniki pomiarów
Effect of the use of energy efficiency wooden house DomTrzon on indoor comfort parameters – measurements results
Autorzy:
Bandurski, K.
Mielczyński, T.
Koczyk, H.
Powiązania:
https://bibliotekanauki.pl/articles/362914.pdf
Data publikacji:
2015
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
pomiar komfortu
użytkownicy
budownictwo energooszczędne
budownictwo ekologiczne
piec akumulacyjny
comfort measurement
users
energy-saving buildings
green building
accumulation stove
Opis:
DomTrzon (znany również jako Bio_Arka) jest drewnianym budynkiem jednorodzinnym, wykonanym w standardzie energooszczędnym, o konstrukcji masywnej. Obiekt jest wyposażony w mechaniczną instalację wentylacyjną z rekuperatorem. Głównym źródłem ciepła na cele grzewcze jest akumulacyjny piec opalany drewnem, który służy również do przygotowywania posiłków. Artykuł prezentuje dziesięciodniowe pomiary (luty 2014r.) wybranych parametrów komfortu wewnętrznego (temperatura, wilgotność, stężenie dwutlenku węgla). Na potrzeby analizy wprowadzono prosty model pieca akumulacyjnego. W referacie przeanalizowano korelacje pomiędzy zawartością wilgoci w powietrzu oraz stężeniem CO2. Osiągnięciem pracy jest również szacunkowa analiza wpływu rodzaju źródła ciepła do przygotowania posiłków na zapotrzebowanie świeżego powietrza. Na podstawie pomiarów zaproponowano kierunki zmian w koncepcji budynku, które mogłyby jeszcze bardziej wykorzystać jego energooszczędny i ekologiczny potencjał.
DomTrzon (also known as Bio_Arka) is wooden, energy-saving, single-family house, with massive construction (exterior walls: 10 cm laminated wood + 30 cm wood fiber insulation). Mechanical ventilation system with cross heat exchanger is installed in the building. Wood-lag accumulation stove is the main heat source in the analyzed object, the stove is used mainly to prepare meals. This paper presents 10–days measurement (February 2014) of selected indoor environment comfort parameters: temperature, relative/absolute humidity, carbon dioxide concentration. In this paper: (1) simple mathematical model of accumulation stove is implemented; (2) correlation between CO2 concentration and absolute humidity is analyzed; (3) influence of kitchen heat source (for meals preparation) on fresh air demand is estimated. Directions of DomTrzon concept development are proposed based on investigation of measurements results. Solutions of indicated imperfections could help to better exploit energy-savings and ecological potential of the building. Authors would like to acknowledge Mr. Joe Huang from White Box Technologies (http://weather.whiteboxtechnologies.com/), who donate climate data used in the analysis.
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2015, T. 7, nr 1, 1; 9-14
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Hiatus hernia – Late complication after gastrectomy followed by double tract reconstruction (DTR): a case report
Autorzy:
Bandurski, R.
Gryko, M.
Dawidziuk, T.
Zaręba, K.
Cepowicz, D.
Kędra, B.
Powiązania:
https://bibliotekanauki.pl/articles/1916509.pdf
Data publikacji:
2014
Wydawca:
Uniwersytet Medyczny w Białymstoku
Tematy:
gastric cancer
hiatus hernia
late complication
surgery
Opis:
In patients with dyspeptic symptoms who have been treated for gastric cancer, other medical conditions apart from cancer recurrence should be considered. A long small-bowel loop left after esophagogastric anastomosis, flaccid diaphragmatic crura, and several external factors such as hard physical exertion can promote the development of postoperative hiatus hernia. The authors of this paper present a rare case of hiatus hernia considered a late complication of primary surgery performed due to gastric cancer. The 63-year-old patient had undergone total gastrectomy with double tract reconstruction (DTR) six years earlier. Gastrectomy was performed with extended lymphadenectomy (>D2). Histopathologic examination of tumor specimens showed mucinous adenocarcinoma with no lymph node metastasis and no distant metastases (pathologic staging: pT2, pN0, pM0). After six years, the patient was admitted to the 2nd Department of General and Gastroenterologic Surgery with abdominal pains, malaise, weight loss and feeling of fullness after small meals. Diagnostic procedures performed showed the presence of hiatus hernia, a very rare complication after this particular surgery, with no features of cancer recurrence. The patient was underwent surgery and the hernia was successfully repaired.
Źródło:
Progress in Health Sciences; 2014, 4, 1; 265-268
2083-1617
Pojawia się w:
Progress in Health Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies