Tytuł:
Range resolution improvement of range-gated vision system in backscattering hazy environments
Autorzy:
Park, S.-K.
Choi, I.-Y.
Baik, S.-H.
Jeong, K.-M.
Powiązania:
https://bibliotekanauki.pl/articles/174523.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
range-gated vision system
range image
windowed center-of-mass
cross-correlation
Gaussian window
Opis:
A range-gated vision system simultaneously provides two-dimensional and range images because its light intensity contains the reflectance as well as depth information. The range-resolution of the system is usually inversely proportional to the induced backscattering noise. In this paper, a range imaging technique is proposed to precisely measure range information from highly backscattering foggy environments. A windowed center-of-mass position extracted from the peak area of a cross-correlation signal of two signals, a Gaussian window signal in reduced size and a range-gated signal according to distance, is adopted as the range depth. The proposed measuring technique provides more robust and more precise range information than conventional measuring techniques for hazy targets by virtue of the reduction of backscattering bias noise usually induced by airborne particles. The experimental results and the signal processing procedures to acquire precise range information from hazy targets are described in this paper.
Źródło:
Optica Applicata; 2017, 47, 4; 533-543
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Error reduction of the Doppler lidar signal using a re-normalization method
Autorzy:
Park, N G
Baik, S H
Park, S K
Kim, D L
Kim, D. H.
Powiązania:
https://bibliotekanauki.pl/articles/173914.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
injection-seeded laser
Doppler lidar
frequency locking
wind lidar
Doppler velocity measurement
Opis:
In this paper, we present a re-normalization method for a Doppler signal of a Doppler lidar system. For the Doppler lidar system, we used an injection-seeded pulsed Nd:YAG laser as a transmitter and an iodine cell as a Doppler frequency discriminator. A frequency locking system that uses the absorption feature of iodine gas is too sensitive to the external or internal noises (iodine cell temperature instability, laser frequency fluctuation, environmental noises, etc.) to maintain its locking point ideally, and this frequency locking error makes the Doppler lidar system acquire the noises as the Doppler frequency shifts. To reduce the Doppler signal error induced by a frequency locking error, we used a re-normalization method by an addition of a laser beam path separated from a transmitter to the Doppler frequency discriminator for re-normalization. In this method, fluctuations of the Doppler signal were reduced using the reference signal. The reduced amount of standard deviation between the Doppler signal and the re-normalization signal was 4.838×10–3 and the Doppler signals showed a 53.3% fluctuation reduction of the averaged error value by this method.
Źródło:
Optica Applicata; 2014, 44, 1; 103-111
0078-5466
1899-7015
Pojawia się w:
Optica Applicata
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies