Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Badura, Henryk" wg kryterium: Autor


Wyświetlanie 1-9 z 9
Tytuł:
Analysis of Exploitation Parameters in Drainage Boreholes of the Longwall Demethylation System. Case Study
Autorzy:
Badura, Henryk
Łukaszczyk, Zygmunt
Powiązania:
https://bibliotekanauki.pl/articles/2064617.pdf
Data publikacji:
2021
Wydawca:
STE GROUP
Tematy:
hard coal mine
degasification
methane concentration
drainage boreholes
Opis:
In hard coal mines with methane, there is often a need to apply demethylation in order to keep the methane concentration not exceeding 2% in the ventilation air. The basic demethylation method in longwall areas is through drainage boreholes made in the roof rocks of the coal bed, from top gate, in front of the longwall. The drainage boreholes are usually made in bundles, in a fan-shaped arrangement, with several boreholes in each bundle. The paper presents the results of measurements and tests of the efficiency of a bundle of four drainage boreholes drilled approximately 100 m in front of the longwall face. The efficiency of individual boreholes was analyzed in time and depending on the distance of borehole outlets from the longwall face. It was found that there is a large variation in the extraction of air-methane mixture by individual drainage boreholes, as well as large differences in the efficiency of individual drainage boreholes during the longwall extraction process.
Źródło:
Multidisciplinary Aspects of Production Engineering; 2021, 4, 1; 23--39
2545-2827
Pojawia się w:
Multidisciplinary Aspects of Production Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of forecasted methane concentration at the top gate of a wall ventilated by means of the “U” system. Case study
Autorzy:
Łukaszczyk, Zygmunt
Badura, Henryk
Powiązania:
https://bibliotekanauki.pl/articles/27315553.pdf
Data publikacji:
2022
Wydawca:
STE GROUP
Tematy:
methane
average concentration of methane
forecast
methane concentration sensors
PROGMET program
Opis:
The release of methane into the mine atmosphere poses a threat to the miners. Methane is an explosive gas at concentrations of 5-15% in air by volume and throughout the history of coal mining has been the cause of devastating explosions in mines around the world. For these reasons, in methane coal mines, the concentration of methane emitted from the coal face and the entire mine is controlled by means of a well-designed ventilation system, a system controlling the concentration of methane in the mine atmosphere and a system for methane drainage of the rock mass and goafs. The presented article concerns the forecast of the average concentration of methane on a given day, in the places of sensors located in the longwall roadways of discharge air exhausted from the longwall: up to 10 m in front of the wall and at the outlet of the roadway. Both forecasts were made using the prognostic equations on the basis of measurement data concerning the ventilation roadways of one of the longwalls at JSW SA.
Źródło:
Management Systems in Production Engineering; 2022, 4 (30); 342--347
2299-0461
Pojawia się w:
Management Systems in Production Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Methane Concentration Distribution at U-Ventilated Longwall Outlet – Case Study
Autorzy:
Niewiadomski, Adam
Badura, Henryk
Ivanova, Tanyana N.
Repko, Alexandr
Yury, Nikitin R.
Powiązania:
https://bibliotekanauki.pl/articles/2064299.pdf
Data publikacji:
2020
Wydawca:
STE GROUP
Tematy:
longwall ventilation
coal mine methane
correlation
autocorrelation
korelacja
autokorelacja
zagrożenie metanowe w kopalniach
wentylacja kopalni
Opis:
The methane hazard concerns a growing number of longwalls in the Polish coal mining industry each year. Mitigating this hazard, both of work safety and economic reasons requires the application of preventive measures adequate to its level. Commonly threat level is estimated based on registered methane concentrations, which fluctuate and highly depends on the place of measurement. The article presents studies on the average and maximum methane concentrations at the longwall outlet, including analyses of the interdependence of methane concentration in methanometry sensors installation locations.
Źródło:
New Trends in Production Engineering; 2020, 3, 1; 149 --168
2545-2843
Pojawia się w:
New Trends in Production Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of Methane Emissions From Air Shafts of the Jastrzębska Coal Mining Company in 2017-2019
Autorzy:
Badura, Henryk
Łukaszczyk, Zygmunt
Powiązania:
https://bibliotekanauki.pl/articles/2064768.pdf
Data publikacji:
2020
Wydawca:
STE GROUP
Tematy:
methane
demethanation
removal of methane
ventilation air methane
JSW Co. Ltd
Opis:
The paper presents formation of the amount of methane released from a coal deposit during coal mining. The total amount of released methane is composed of the amount separated directly into the ventilation air in mines (ventilation methane) and included in the demethanation system, isolated from the ventilation air. Methane from the demethanation system is only partially utilized. The unused part of methane is discharged into the atmosphere. The paper presents how the amount of methane released in individual mines of Jastrzębska Spółka Węglowa S.A. was shaped, with a division into methane released to the ventilation system and included in the demethanation system, taking into account the part used for economic purposes and the part discharged to atmosphere. The research material covers the years 2017-2019.
Źródło:
Multidisciplinary Aspects of Production Engineering; 2020, 3, 1; 435--449
2545-2827
Pojawia się w:
Multidisciplinary Aspects of Production Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of one-day forecasts of the maximum methane concentration in a tailgate of a longwall ventilated with U system - a case study
Autorzy:
Badura, Henryk
Powiązania:
https://bibliotekanauki.pl/articles/27324329.pdf
Data publikacji:
2022
Wydawca:
Instytut Techniki Górniczej KOMAG
Tematy:
methane
maximum methane concentration
methane concentration forecasts
methane concentration sensors
Opis:
Methane that is released into the mine atmosphere poses a threat to the miners working there. Methane at concentrations of 5-15% by volume in air is an explosive gas. It has caused devastating explosions in mines all over the world. Therefore, in methane mines, concentration of methane in the face and in the entire mine is controlled through welldesigned ventilation system. This system controls concentration of methane in the mine atmosphere and in the rock mass as well as in the mine goafs. The article’s main objective includes a presentation of a forecast for maximal methane concentration in the determined time interval. Sensors were installed in the gate draining the air from longwall: up to 10 m in front of the longwall and at the roadway exit. Both forecasts were made using prognostic equations, using the measurement data in the ventilation roadway of one of the longwalls at the JSW S.A. mine.
Źródło:
Mining Machines; 2022, 40, 3; 149--157
2719-3306
Pojawia się w:
Mining Machines
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
One-Day Prognoses of Methane Concentrations for the 102 Longwall in the 325/1 Seam in the “W” Coal Mine Operating in a Continuous System
Autorzy:
Grodzicka, Aneta
Badura, Henryk
Shaidurova, Natalia
Sentyakov, Kirill
Sviatskii, Vladislav
Powiązania:
https://bibliotekanauki.pl/articles/2064336.pdf
Data publikacji:
2020
Wydawca:
STE GROUP
Tematy:
continuous exploitation
methane content
mean methane concentration
methane concentration prognosis
eksploatacja ciągła
średnie stężenie metanu
prognozy stężenia metanu
Opis:
The first part of the paper concerns the natural deposition conditions of the 325/1 seam in the “W” coal mine, in the 102 longwall mining panel. It also presents the most important technical conditions regarding the exploitation at this longwall. To characterize the methane hazard in the longwall area, the parameters of ventilation and total methane concentrations as well as the volumetric flowrate of methane captured by the methane removal system, have been presented graphically. A significant part of the methane flow in the longwall area was released to the air flowing to the longwall. The most significant part of the article is the presentation and analysis of the results of prognoses of mean methane concentrations at the exhaust of the longwall area. The accuracy of the prognoses of methane concentration was verified using two methods: while not considering the release of methane to the air flowing to the longwall and while considering the total flowrate of methane to the ventilation air in the area of the 102 longwall. The method of forecast presented in the article has so far been checked for a 5-day and 6-day work day, as well as for walls operating in a non-regular mode. The article refers to the wall operating in a continuous mode, which required adaptation of the proposed method to this mode. The application of the one-day forecast proposed in the article allows for undertaking temporary methane prevention measures enabling safe use of the wall.
Źródło:
New Trends in Production Engineering; 2020, 3, 1; 169--185
2545-2843
Pojawia się w:
New Trends in Production Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Prognoza stężenia metanu na wylocie ze ściany oraz w chodniku wentylacyjnym - studium przypadku
Forecast of methane concentration at the end of and in the ventilating roadway - a case study
Autorzy:
Badura, Henryk
Powiązania:
https://bibliotekanauki.pl/articles/27323733.pdf
Data publikacji:
2023
Wydawca:
STE GROUP
Tematy:
prognoza metanowości
ściana metanowa
chodnik wentylacyjny
ściana
dokładność prognoz
forecast of methane concentration
methane longwall
ventilating airway
longwall
forecast accuracy
Opis:
Dotychczas stosowne jednodniowe prognozy średniego stężenia metanu dotyczące ścian odnosiły się przede wszystkim do wylotu z chodnika wentylacyjnego, gdyż na podstawie pomiarów w tym miejscu zostały opracowane. W przedstawionym artykule równania prognostyczne zostały zastosowane do prognozowania stężenia metanu na wylocie z chodnika wentylacyjnego, w chodniku wentylacyjnym w odległości do 10 m od czoła ściany oraz na wylocie ze ściany. Wyniki prognoz na wylocie z chodnika stanowiły materiał porównawczy w stosunku do wyników prognoz w pozostałych wymienionych miejscach. Uzyskane wyniki prognoz są bardzo zbliżone do wartości pomiarowych i zachęcają do przeprowadzenia dalszych prac sprawdzających ich praktyczna przydatność.
Until now, the appropriate one-day forecasts of average methane concentration for walls were related primarily to the end of the ventilating roadway, as they were developed on the basis of the measurements made in that place. In the presented article, predictive equations were used to estimate the methane concentration at the end of the ventilating roadway, in a ventilating roadway at a distance of up to 10 m from the face of the wall, and at the wall end. The results of the forecasts at the end of the ventilating roadway were used as a reference material to compare to the results of forecasts in other, above-mentioned, places. The forecast results obtained are very similar to the measured values and encourage further work to be done in order to check their practical usefulness.
Źródło:
Systemy Wspomagania w Inżynierii Produkcji; 2023, 12, 1; 84--94
2391-9361
Pojawia się w:
Systemy Wspomagania w Inżynierii Produkcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of the Accuracy of Methane Concentration Forecasts in the Area of Longwall Outlet B-3 in Seam 407/1 in KWK “Borynia-Zofiówka” Ruch Zofiówka
Autorzy:
Badura, Henryk
Zmarzły, Marian
Trzaskalik, Paweł
Korshunov, Aleksandr Ivanovich
Powiązania:
https://bibliotekanauki.pl/articles/2064273.pdf
Data publikacji:
2020
Wydawca:
STE GROUP
Tematy:
longwalls
methane hazard
methane concentration forecast
testing of forecast accuracy
prognozy stężenia metanu
dokładność prognoz
zagrożenie metanowe
Opis:
In the presented publication, an ex post forecast of methane concentration at the airway outlet was carried out on the basis of equations previously developed and repeatedly tested by H. Badura and its errors were calculated. This forecast was considered as a reference level. Next, using the same forecast equations, the forecasting of methane concentration at the sensor location up to 10 m in front of the longwall face and at the longwall outlet was carried out, followed by the analysis of forecast errors. Since the measurement of methane concentrations in the locations under consideration differed, the results of forecasts also differed. Therefore, in order to assess the accuracy of forecasts, their absolute and relative errors were calculated and then compared with the forecast errors at the airway outlet. The analysis of errors showed that there are differences in forecast accuracy and it is advisable to develop new forecast equations mainly for the longwall outlet, but also for the location of methane concentration sensor installed in the airway up to 10 m in front of the longwall.
Źródło:
New Trends in Production Engineering; 2020, 3, 1; 120--130
2545-2843
Pojawia się w:
New Trends in Production Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zagrożenie pyłami szkodliwymi dla zdrowia w zmechanizowanych robotach przygotowawczych
Hazard of dusts harmful to health in the mechanized preliminary work
Autorzy:
Sołtysiak, Tomasz
Lebecki, Kazimierz
Małachowski, Marcin
Badura, Henryk
Powiązania:
https://bibliotekanauki.pl/articles/1841034.pdf
Data publikacji:
2020
Wydawca:
STE GROUP
Tematy:
zagrożenie pyłami
pomiary zapylenia
optyczne pomiary zapylenia
grawimetryczne pomiary zapylenia
dust hazard
dustiness measurements
optical dust measurement
gravimetric dust monitoring
Opis:
Zmechanizowane, prowadzone z użyciem nowoczesnych kombajnów chodnikowych roboty przygotowawcze są przyczyną wysokich stężeń pyłów szkodliwych dla zdrowia. W artykule przedstawione są wyniki pomiarów zapylenia powietrza w typowym wyrobisku przygotowawczym.
Mechanized preliminary work carried out with the use of modern heading machines is the cause of high concentrations of harmful dust. The article presents the results of air dustiness measurements in a typical development working.
Źródło:
Systemy Wspomagania w Inżynierii Produkcji; 2020, 9, 2; 120-132
2391-9361
Pojawia się w:
Systemy Wspomagania w Inżynierii Produkcji
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-9 z 9

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies