Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Bąk, Daniel" wg kryterium: Autor


Wyświetlanie 1-4 z 4
Tytuł:
Waste in the Context of Combustibility – Classification Possibilities in Legal Terms
Odpady w kontekście palności – możliwości klasyfikacji w ujęciu prawnym
Autorzy:
Klapsa, Wojciech
Małozięć, Daniel
Bąk, Damian
Powiązania:
https://bibliotekanauki.pl/articles/2060754.pdf
Data publikacji:
2021
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
combustible waste
non-combustible waste
waste classification
fire protection
landfills
odpad palny
odpad niepalny
klasyfikacja odpadów
ochrona przeciwpożarowa
składowiska odpadów
Opis:
Purpose: The aim of the article is to review the possibility of classifying waste as non-combustible and combustible on the basis of the applicable Polish legal acts and to discuss the problems related to this area. Introduction: In the last decade, there has been a marked increase in the number of fires in landfills in Poland. Therefore, a legislative initiative has been undertaken to tighten and complete the provisions of the law on fire protection of facilities and places where waste is collected and stored. Methodology: The basic act regulating the issues of waste storage in Poland is the Act of 14 December 2012 on waste materials. The Act divides waste into two categories: non-combustible and combustible. In reference to the act, a Regulation of the Minister of the Interior and Administration of 19 February 2020 on fire protection requirements which need to be met by construction structures or their parts and other places for collecting, storing or processing waste, in which stringent fire safety requirements were defined for fire safety of facilities where combustible waste is stored. Results: During the review and analysis of the legal acts, it was discovered that after the division into combustible and non-combustible waste, the classification rules for these two categories were not strictly defined. As a consequence, there was a problem of interpretation and, thus, discretion in classifying waste. Therefore, there was a need to review the knowledge on the possibility of classifying waste. Conclusions: The review of regulations and the state of knowledge on the principles of considering materials and products as non-combustible or combustible presented in the article allows to systematize the knowledge and indicates selected paths of conduct. As waste is not homogeneous materials, the Act leaves the freedom to carry out opinions on whether or not waste is considered combustible. Such an assessment is not simple, hence the need to indicate what are the possible correct ways of proceeding in this action.
Cel: Celem artykułu jest przegląd możliwości klasyfikowania odpadów na niepalne i palne w oparciu o obowiązujące polskie akty prawne oraz omówienie problemów związanych z tym obszarem. Wprowadzenie: W ostatniej dekadzie w Polsce nastąpił wyraźny wzrost liczby pożarów składowisk odpadów i wysypisk śmieci. W związku z tym została podjęta inicjatywa legislacyjna, aby zaostrzyć oraz uzupełnić przepisy prawa dotyczące ochrony przeciwpożarowej obiektów i miejsc, gdzie są gromadzone i przechowywane odpady. Metodologia: Podstawowym aktem regulującym kwestie składowania odpadów w Polsce jest ustawa z dnia 14 grudnia 2012 r. o odpadach. W ustawie dokonano podziału odpadów na niepalne i palne. Co jest istotne dla problemu, nie określono ścisłych wymagań dla potrzeb klasyfikacji odpadów do tych dwóch kategorii. W nawiązaniu do ustawy opracowano rozporządzenie Ministra Spraw Wewnętrznych i Administracji z dnia 19 lutego 2020 r. w sprawie wymagań w zakresie ochrony przeciwpożarowej, jakie mają spełniać obiekty budowlane lub ich części oraz inne miejsca przeznaczone do zbierania, magazynowania lub przetwarzania odpadów, w którym określone zostały rygorystyczne wymagania w zakresie bezpieczeństwa pożarowego obiektów, w których składowane są odpady palne. Wyniki: Podczas przeglądu i analizy aktów prawnych stwierdzono, że po dokonaniu podziału na odpady palne i niepalne nie określono ściśle zasad klasyfikacji do tych dwóch kategorii. W konsekwencji pojawił się problem interpretacji i – co za tym idzie – uznaniowości klasyfikowania odpadów. W związku z tym zaistniała potrzeba przeglądu wiedzy na temat możliwości klasyfikowania odpadów. Wnioski: Przedstawiony w artykule przegląd przepisów i stanu wiedzy na temat zasad uznawania materiałów i wyrobów za niepalne lub palne pozwala usystematyzować wiedzę oraz wskazuje wybrane ścieżki postępowania. Ponieważ odpady nie są materiałami jednorodnymi, ustawa pozostawia dobrowolność w zakresie wykonywania opinii dotyczących uznania odpadów za palne lub nie. Taka ocena nie jest prosta, stąd pojawiła się potrzeba wskazania, jakie są możliwe prawidłowe drogi postępowania w tym działaniu.
Źródło:
Safety and Fire Technology; 2021, 57, 1; 42--48
2657-8808
2658-0810
Pojawia się w:
Safety and Fire Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Męsko-męski seks heteryków, czyli społeczno-kulturowy przewodnik po tym, jak go uprawiać i nie zostać gejem
The Male-to-Male Sex of Straight Guys: A Socio-Cultural Guide on How to Have It and Not Become a Gay Man
Autorzy:
Bąk, Daniel
Powiązania:
https://bibliotekanauki.pl/articles/1372971.pdf
Data publikacji:
2018-06-28
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
male sexuality
male sexual identity
fluidity of sexual identities
homosexuality
męska seksualność
męska tożsamość seksualna
płynność tożsamości seksualnych
homoseksualność
Opis:
Reachable knowledge, which is a collection of socially negotiated constructs and narratives, imposes limits on possible ways of understanding the world around us. A dominant discourse becomes a boundary of cognition. The contemporary discourse on male sexual identity cements and limits it to a homosexual or heterosexual version. The socio-cultural rules producing hetero- and homosexuality can be particularly well viewed in the example of men who identify as heterosexuals yet have sex with other men. This article provides a recipe for the effective union of heterosexuality with homosexual desire, free of the danger of social stigma. At the same time, the article attempts to disclose how the development of male sexuality is restricted by modern modes of knowledge production in regard to male sexuality and by forcing men to practice their sexuality in a pre-specified manner. The article also gives voice to alternative ways of understanding male sexuality, especially through the lens of fluidity, changeability, and vagueness.
Źródło:
Kultura i Społeczeństwo; 2018, 62, 2; 185-196
2300-195X
Pojawia się w:
Kultura i Społeczeństwo
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Medical students in the face of SARS-CoV-2 pandemic: an estimated risk of infection and the need for social support
Autorzy:
Wyszomirska, Julia
Daniel-Sielańczyk, Anna
Bąk-Sosnowska, Monika
Powiązania:
https://bibliotekanauki.pl/articles/2085723.pdf
Data publikacji:
2022-08-01
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
social support
medical students
coronavirus
COVID-19
pandemic
SARS-CoV-2
Opis:
ObjectivesA pandemic triggers certain attitudes and behaviors, resulting in the need for adequate social support. The aim of the study was to determine the factors influencing the estimated risk of SARS-CoV-2 infection and to assess the need for social support in a group of medical students.Material and MethodsThe survey was conducted among 981 people, including 814 women and 167 men. For this purpose, a self-assessment survey with 22 multiple-choice questions was used. The online survey was conducted on March 20–April 2, 2020, which can be considered as the first stage of the pandemic in Poland.ResultsThe tested model for the subjective SARS-CoV-2 infection risk assessment explained 32.6% of the dependent variable variance (F(7.945) = 66.61, p < 0.001). The model for adherence to the recommendations for reducing the risk of SARS-CoV-2 transmission explained 9.5% of the variability (F(8.943) = 12.39, p < 0.001), and the model for an increased need for social support due to the SARS-CoV-2 epidemic explained 27.4% of the variability (χ2(8) = 12.17, p = 0.144).ConclusionsFactors important for estimating the risk of SARS-CoV-2 infection and the need for social support in the group of medical students were determined. The subjective assessment of the stress level, infection symptoms experienced and the field of study proved to be crucial.
Źródło:
International Journal of Occupational Medicine and Environmental Health; 2022, 35, 4; 473-484
1232-1087
1896-494X
Pojawia się w:
International Journal of Occupational Medicine and Environmental Health
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the Effectiveness of Active HRD Systems for Dust Explosion Suppression in a Technology Demonstrator System
Ocena skuteczności tłumienia wybuchu pyłowego w układzie demonstratora przez aktywny system HRD
Autorzy:
Lesiak, Piotr
Bąk, Damian
Małozięć, Daniel
Grabarczyk, Marcin
Kołaczkowski, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/2060848.pdf
Data publikacji:
2019
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
HRD
explosion suppression system
dust explosion
system tłumienia wybuchu
wybuch pyłu
Opis:
Purpose: This paper presents the operation of an active dust explosion (HRD, high rate discharge) suppression system in a confined space. Design and methods: The study involved tests of the developed fire protection system for suppressing dust explosions. The work was carried out under the project entitled “Innovative explosion protection technologies, including for highly protected facilities” No. DOBR-BIO4/052/13073/2013 at the Scientific and Research Centre for Fire Protection in Józefów. A test station designed and constructed to meet the prerequisites of the PN-EN 14034 series of standards was designed for testing. The test equipment consisted of a closed roughly spherical chamber with a volume of 1 m3, an ignition system, a system producing a dust-air atmosphere, and a pressure change detection system. Inside the sphere, a dust-air mixture of a certain concentration was obtained in a reproducible manner. The station was armed with a dust explosion suppression system consisting of: – 5 dm3 fire extinguisher tank containing pressurized fire-extinguishing powder, – a diffusing nozzle, – an explosion detection system. The operation of the extinguishing system is based on the early detection of changes in the explosion pressure of the dust-air mixture, the processing of the signal, and the release of the extinguishing agent inside the apparatus in order to interrupt the explosion process at the earliest possible stage of its development. Results: On the basis of the conducted experiments, it can be concluded that the HRD system effectively interrupts explosive combustion for dust with a Kst ≤ 100 bar · m/s. For the examined potato starch dust, the system significantly reduced the explosion pressure to an acceptable value. The system is also characterised by a short reaction time, and the discharge of the extinguishing powder takes place in less than 100 ms, which is a satisfactory value. Conclusions: The tests were carried out for potato starch and lycopodium. The phenomenon of explosive combustion occurring in the mixture of lycopodium and air is characterised by greater dynamics, compared to starch. This difference allowed to identify the limitation of extinguishing dust explosions in small cubic capacity areas. In addition, research identified issues related to the source of ignition in the form of pyrotechnical heads, the use of which requires the setting of a high-pressure threshold activating the HRD system. This results in a delayed system reaction in the event of ignition of high Kst dust mixtures.
Cel: Celem artykułu jest przedstawienie działania aktywnego systemu tłumienia wybuchów pyłowych (nazwanych HRD od ang. high rate discharge) w przestrzeni ograniczonej. Projekt i metody: W ramach badań przeprowadzono testy wytworzonego systemu gaśniczego do tłumienia wybuchów pyłowych. Prace zostały wykonane w ramach projektu pt. „Innowacyjne technologie zabezpieczeń przed wybuchem, w tym obiektów szczególnie chronionych” nr DOBR-BIO4/052/13073/2013 w Centrum Naukowo-Badawczym Ochrony Przeciwpożarowej w Józefowie. Do badań zaprojektowano i wykonano stanowisko spełniające założenia serii norm PN-EN 14034. Urządzenie badawcze składa się z zamkniętej komory kształtem zbliżonej do kuli o objętości 1 m3 oraz układów: zapłonowego, tworzenia atmosfery pyłowo-powietrznej, detekcji zmian ciśnienia. Wewnątrz sfery uzyskiwano w powtarzalny sposób mieszaninę pyłowo-powietrzną o określonym stężeniu. Stanowisko uzbrojono w system tłumienia wybuchów pyłowych zawierający: – zbiornik gaśnicy o objętości 5 dm3 zawierający proszek gaśniczy pod ciśnieniem, – dyszę rozpraszającą, – system wykrywania wybuchu. Działanie systemu gaśniczego opiera się na wczesnym wykryciu zmiany ciśnienia wybuchu mieszaniny pyłowo-powietrznej, przetworzeniu sygnału oraz wyzwoleniu środka gaśniczego do wnętrza aparatu w celu przerwania procesu wybuchu w jak najwcześniejszej fazie jego rozwoju. Wyniki: Na podstawie przeprowadzonych eksperymentów można stwierdzić, że system HRD skutecznie przerywa spalanie wybuchowe dla pyłu o Kst ≤ 100 bar · m/s. Dla przebadanego pyłu skrobi ziemniaczanej system znacznie redukuje ciśnienie wybuchu do wartości akceptowalnej. Układ charakteryzuje się także krótkim czasem reakcji, a wyładowanie proszku gaśniczego następuje w czasie poniżej 100 ms, co jest wartością satysfakcjonującą. Wnioski: Badania przeprowadzono dla skrobi ziemniaczanej i likopodium. Zjawisko spalania wybuchowego zachodzące w mieszaninie likopodium i powietrza charakteryzuje się większą dynamiką niż w przypadku skrobi. Różnica ta pozwoliła na zidentyfikowanie ograniczenia, jakim jest gaszenie wybuchów pyłowych w niewielkiej kubaturze. Ponadto w badaniach zidentyfikowano problematykę związaną z zastosowanym źródłem zapłonu w postaci główek pirotechnicznych, których zastosowanie narzuca konieczność nastawienia wysokiego progu ciśnienia aktywującego system HRD. Skutkuje to opóźnioną reakcją systemu w przypadku zapłonu mieszanin pyłowych o wysokiej wartości parametru Kst.
Źródło:
Safety and Fire Technology; 2019, 53, 1; 46--66
2657-8808
2658-0810
Pojawia się w:
Safety and Fire Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies