Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Acharya, P." wg kryterium: Autor


Wyświetlanie 1-5 z 5
Tytuł:
Equilibrium process optimisation for Adsorption of phenol from aqueous solution on fly ash during batch operation
Optymalizacja równowagowa procesu adsorpcji fenolu z wodnego rotworu na popiołach lotnych w czasie operacji okresowych
Autorzy:
Sarkar, M.
Acharya, P.
Powiązania:
https://bibliotekanauki.pl/articles/1826302.pdf
Data publikacji:
2000
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
adsorpcja fenolu
popioły lotne
procesu równowagowego
równanie izotermy adsorpcji Langmuir'a
Opis:
Phenol and its higher homologues are the aromatic molecules that degrade aqueous environments in various ways. The origin is both anthropogenic as well as xenobiotic. Xenobiotic sources are industrial wastes derived from fossil fuel extraction, chemical process industries such as phenol manufacturing plants, pharmaceutical industries, wood processing industry, and pesticide manufacturing plants. Continuous ingestion of phenol for a prolonged period of time may cause mouth sore, diarrhea, excretion of dark urineAnthropogenic sources are from forest fire, natural runoffs from urban area where asphalt is used as binding material and natural decay of lignocellulosic materials. and impaired vision at concentration levels ranging between 10 and 240 mg.dm-3 (1). Carbolic acid and cresols are used as anticeptic agents in surgery, which indicates that they are toxic to microbes. Lethal blood concentration for phenol is around 4.7 to 130 mg.dm-3. Phenols are toxic to several biochemical functions (2) and to fish life (3). It acts as a substrate inhibitor in the biotransformation (4). Phenol at concentration as low as 5.0.10-3 mg.dm-3 imparts typical smell upon chlorination and that is why WHO has prescribed a concentration of 1.0.10-3 mg.dm-3 as the guideline concentration for drinking water (5). Elimination of phenol, thus, is a necessity to preserve the environmental quality. Removal of phenol from wastewater by adsorption on activated carbon, synthetic resins have been reported (6-14). But the high cost and difficult procurement of activated carbon and synthetic resins prohibits their use for wastewater treatment. In an aim to search for an alternative, fly ash, the solid waste generated from thermal power plant is chosen as the adsorbent and its adsorption efficiency for phenol removal is highlighted in the present communication. All the reagents were of analytical reagent grade. Standard solution of phenol (5.0.102 mg.dm-3) was prepared by dissolving it in minimum volume of acetone and diluting the solution with distilled water to prepare the test solutions. Fly ash was collected from Bandel Thermal Power Station, Triveni, West Bengal. It was dried, sieved for a definite size and used without pretreatment. Batch study was performed by shaking 1.0 g of fly ash and 50 ml of aqueous phenol solution of appropriate concentration, temperature and pH in glass bottles placed in a shaking incubator. After attaining the equilibrium the adsorbent was removed and phenol concentration was measured spectrophotometrically at 270 nm. Physico-chemical characterisation of fly ash The chemical analyses of fly ash include loss on ignition at 800°C, silica, aluminium oxide, calcium oxide and magnesium oxide. Physical properties such as specific gravity and surface area are also determined (Table 1). Adsorption occurs due to the accumulation of solute from aqueous solution to the surface of adsorbent. The time at which equilibrium is attained is known as equilibrium time and the concentration at this time is the equilibrium concentration. The adsorption equilibrium and the adsorption time depend on several factors such as nature or speciation of phenol and surface property of fly ash, solution pH as well as the operational temperature. In order to find out the time for equilibrium adsorption, the interaction period for phenol and fly ash was varied and the percent adsorption was plotted for different time intervals. It was found that at the initial stage, rate of adsorption of phenol is quite high and reaches a maximum after 240 minutes that does not change with further lapse of time.
Praca dotyczy optymalizacji procesu równowagowego adsorpcji fenolu z wodnych roztworów przy wykorzystaniu lotnych popiołów. Fenole i ich wyższe homologiczne są związkami aromatycznymi, które powodują degradację środowiska wodnego. Stężenia fenoli w granicach od 10 do 240 mg/dm3 są groźne dla organizmów żywych, nie tylko człowieka ale również świata zwierzęcego. Człowiek odczuwa zapach fenolu już przy stężeniach 5ź10-3 mg/dm3, podczas gdy Światowa Organizacja Zdrowia dopuszcza spożywanie wody pitnej przy stężeniu fenolu poniżej 1ź10-3 mg/dm3. Jest to zatem temat istotny problem badawczy. Autorzy przeprowadzili badania adsorpcji i oczyszczania roztworów z fenolu. Do badań doświadczalnych autorzy przyjęli standardowy roztwór fenolu 5ź10-2 mg/dm3 przez rozpuszczenie go w minimalnej ilości acetonu i wykonanie roztworu do testowania z wodą destylowaną. Lotne popioły do badań pobrano z Ciepłowni Triveni w Zachodnim Bengalu, Indie. Wykonano charakterystykę fizykochemiczną pobranych popiołów a następnie przeprowadzono optymalizację zmiennych operacyjnych. Wiadomo, że szybkość procesu adsorpcji wzrasta wraz z temperaturą, co przedstawiono w postaci modelu. Przy stałej temperaturze, proces adsorpcji zależy jedynie od trzech parametrów: Co - początkowego stężenia fenolu, PS - wielkości cząstki adsorbentu, oraz pH - kwasowości/zasadowości środowiska. Do zbadania danych adsorpcji równowagowej wykorzystano równanie izotermy adsorpcji Langmuir'a. Krzywe izotermy Langmuir'a wykreślono dla trzech różnych temperatur, na podstawie których wyznaczono stałe Langmuir'a Qo (mg/g) i b (dm3/mg). Wysokie współczynniki regresji, wynoszące ponad 0,99 i niskie wartości wariancji (0,27 i mniej) świadczą o prawidłowym wyborze izotermy adsorpcji Langmuir'a. Dla zbadania natury jak i możliwości przeprowadzenia procesu wyznaczono termodynamiczne parametry adsorpcji. Ujemne wartości zmiany energii swobodnej Gibbs'a OG dla trzech badanych temperatur świadczą, że proces adsorpcji fenoli przebiega spontanicznie, natomiast pozytywna wartość entalpii OH poparta rosnącą losowością (dodatnia wartość entropii AS) mówi, że jest to proces endotermiczny.
Źródło:
Rocznik Ochrona Środowiska; 2000, Tom 2; 103-112
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Removal/reduction of organic pollutants from aqueous environment
Usunięcie/redukcja zanieczyszczeń organicznych ze środowiska wodnego
Autorzy:
Sarkar, M.
Das, M.
Manna, S.
Acharya, P.
Powiązania:
https://bibliotekanauki.pl/articles/1826240.pdf
Data publikacji:
2003
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
zanieczyszczenia organiczne wody
adsorpcja siarczanu
jakość wody
Opis:
The problem of considerable contamination of the aqueous environment with organic pollutants still requires the development of quick and simple methods for the removal, separation and determination of these compounds. The main classes of organic compounds that most of the industries use and discharge into the effluents are phenol, surfactant and dye. All these compounds are troublesome contaminants which pose not only to toxicity and health hazards but also hamper the environmental treatment processes. In chemical industry phenol is considered as an important starting materials for numerous intermediates and finished products. It is used for the production of a wide range of consumer goods and process materials ranging from adhesives, resins, emulsifiers and detergents, plasticizers, herbicides, dyes and flavors. The worldwide production of phenol is estimated to be 5 million tons per year. Phenol and its analogues are known to be toxic to microbes. The sign of acute illness induced by phenols in experimental animals as well as in humans is known. Continuous ingestion of phenol for a prolonged period of time causes mouth sore, diarrhoea, excretion of dark urine and impaired vision at concentration levels 10÷240 ppm. Lethal blood concentration for phenol is around 1.3 g/L. phenols are toxic to several biochemical functions and to fish life. It acts as a substrate inhibitor in the bio-transformation. World Health Organization (WHO) prescribed a concentration 1 ppb as the guideline concentration in drinking water [1]. Disposal of dyeing industry waste water pose one of the major problem, because such effluents contain a number of contaminants including acid or base, dissolve solids, surfactants and color. Out of these, color is the first contaminant to be recognized because it is visible to human eye. The dye causes the harmful action to various aquatic lives. As it is resistant to light it protects the sunlight from penetrating through it and reduces the aesthetic quality of water. Possible methods of color removal include chemical oxidation, froth flotation, coagulation, adsorption, etc. The anionic surfactants generally are removed by the chemical precipitation, foam separation, ultrafiltration and adsorption. Possible means of removal of phenols from waste water include ion exchange, reverse osmosis, chemical oxidation, precipitation, distillation, gas stripping, solvent extraction, adsorption or bio remediation. Removal of SDS, 4-nitrophenol and malachite green by activated carbon is an efficient and acceptable process. But the cost of operation is very high. Therefore, the present study is undertaken using fly ash as the adsorbent. Compared to activated carbon the efficiency of removal is less in case of 4-nitrophenol and SDS. But fly ash, being a waste material, is very cheap; only the carrying cost from the site of thermal plant to the laboratory is needed. Thus the use of fly ash in removing organic pollutants appears to be a cost viable. The simplicity of the technique makes the process quite acceptable.
Obecność organicznych zanieczyszczeń w strumieniu ścieków znacznie degraduje jakość wody. Zarówno własność estetyczne jaki i organizmy wodne stają wobec niebezpieczeństwa związanego z taką degradacją. Usunięcie zanieczyszczeń organicznych szczególnie za pomącą prostych i tanich metod jest wyzwaniem dla naukowców zajmujących się środowiskiem. Obecnie komunikaty naukowe mówią o możliwości zastosowania popiołów lotnych, odpadów stałych powstających w elektrociepłowniach, w usuwaniu albo redukcji ładunków niektórych organicznych zanieczyszczeń. W referacie przedstawiono wyniki badań nad adsorpcją siarczanu dodecylu sodu SDS (anionowy środek powierzchniowo czynny), zieleni malachitowej MG oraz 4-nitrofenolu na popiołach lotnych. Usunięcie SDS, 4-nitrofenolu i zieleni malachitowej na węglu aktywnym jest skutecznym i zadowalającym procesem. Ale koszt tej operacji jest bardzo wysoki. Dlatego, przedsięwzięto obecne badania używając popiołów lotnych jako substancji adsorbująca. W porównaniu do węgla aktywnego efektywność usunięcia na popiołach lotnych jest mniejsza w przypadku 4-nitrofenolu i SDS. Ale popioły lotne, będąc odpadem, są bardzo tanie. W ten sposób użycie popiołów lotnych w usuwaniu organicznych zanieczyszczeń okazuje się być wykonalne pod względem kosztów. Proces jest wykonalny kinetycznie i termodynamicznie, prosty w wykonaniu i tani.
Źródło:
Rocznik Ochrona Środowiska; 2003, Tom 5; 79-86
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
In vitro propagation of Nepalese orchids: a review
Autorzy:
da Silva, J.A.T.
Acharya, K.P.
Powiązania:
https://bibliotekanauki.pl/articles/1932.pdf
Data publikacji:
2014
Wydawca:
Instytut Ogrodnictwa
Tematy:
in vitro propagation
Nepal
Orchidaceae
orchid
seed germination
tissue culture
germplasm
Źródło:
Journal of Horticultural Research; 2014, 22, 2
2300-5009
Pojawia się w:
Journal of Horticultural Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Identification and Quantification of Gases Releasing from Furan no Bake Binder
Autorzy:
Acharya, S. G.
Vadher, J. A.
Kanjariya, P. V.
Powiązania:
https://bibliotekanauki.pl/articles/379863.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
furan
GC-MS
FTIR
binder
pyrolysis
furan no bake
spoiwo
piroliza
Opis:
Sand samples with furan binder were prepared using Sand, Furfuryl Alcohol and Toluene Sulfonic Acid with ratio 100:0.85:0.30. To identify and quantify gases releasing from furan binder various studies like FTIR, TGA and GC-MS were carried out. After analyzing our materials using above mentioned characterizations the chemical formula of the Resin and Binder and amount of gases releasing from composition were confirmed. After studying various reports on pyrolysis process of furan binder calculation of the % of various gases emitting during pyrolysis process of furan was carried out. Sample of gas collected from mold was analyzed using GC-MS. Based on GC-MS measurement various gases emitting from furan sand mold were identified and their amount were calculate and compared with the international standers of permissible gas emission limits in a foundry. The purpose of this paper is to assist foundries in pollution prevention by devising clean technologies which maintain or improve the quality of ambient surrounding. This paper aimed at minimization of pollution of air by using various techniques.
Źródło:
Archives of Foundry Engineering; 2016, 16, 3; 5-10
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Functional appliances: The activator and the functional regulator- A review
Autorzy:
Kishnani, R.
Uppal, S.
Patel, G.
Acharya, A.
Metha, P.
Powiązania:
https://bibliotekanauki.pl/articles/1916521.pdf
Data publikacji:
2014
Wydawca:
Uniwersytet Medyczny w Białymstoku
Tematy:
Activator
functional regulator
myofunctional appliances
Opis:
In this review of literature we are discussing the effects of functional appliances on the dentofacial structures in the treatment of Class II malocclusions. Despite recent questions on the effectiveness of early treatment, it is generally recognized that the use of growth modification still has a place in modern orthodontic practices. The aim of this review is to study growth modification of the mandible by two appliances: the activator and the functional regulator. Mechanism of action, design, effect on dentofacial structures, etc. of activator and the functional regulators are discussed here. Regardless of the appliance used, there are a large amount of variations in individual patient response to treatment. A second stage of treatment with a fixed appliance is necessary in most cases to ensure proper alignment and interdigitation of the dentition. Regardless of the appliance used, the success of treatment is dependent on patient cooperation.
Źródło:
Progress in Health Sciences; 2014, 4, 2; 150-156
2083-1617
Pojawia się w:
Progress in Health Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies