Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Łokietek, T." wg kryterium: Autor


Wyświetlanie 1-4 z 4
Tytuł:
The energy efficiency monitoring of a refrigeration unit
Autorzy:
Jaszczak, S.
Łokietek, T.
Powiązania:
https://bibliotekanauki.pl/articles/114062.pdf
Data publikacji:
2016
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
refrigeration unit
SCADA system
energy efficiency
Opis:
In the paper, a monitoring system of a refrigeration unit is presented. This system consists of several measurement elements e.g. (pressure, temperature, energy, etc. sensors) connected using a serial RS485 network. A measurement level is a source of data for both SCADA environment and a PLC controller which are essential elements of the whole control system. The first stage of the study was related to the selection of measurement devices and a construction of a serial network. The authors also described how to link a serial 485 network with a PLC controller and how to introduce it into TCP/IP network. In the first part of the paper, there is presented a refrigeration unit as a subject of the monitoring. Then the authors describe a theoretical background needed for the energy efficiency calculation. After that the system structure with selected details about hardware integration and SCADA software implementation is presented. The final part contains selected real time experiments to show typical working modes of the refrigeration unit and to prove the efficiency of the developed monitoring system.
Źródło:
Measurement Automation Monitoring; 2016, 62, 6; 202-205
2450-2855
Pojawia się w:
Measurement Automation Monitoring
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Monitoring pracy centrali klimatyzacyjnej
Monitoring of the Air Handling Unit operation
Autorzy:
Łokietek, T.
Jaszczak, S.
Powiązania:
https://bibliotekanauki.pl/articles/316033.pdf
Data publikacji:
2016
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
monitoring
centrala klimatyzacyjna
SCADA
Air Handling Unit
Opis:
W artykule został przedstawiony system monitorowania centrali klimatyzacyjnej. System ten składa się z kilku elementów pomiarowych (ciśnienie, temperatura, wilgotność, energia, itp. czujników) połączonych za pomocą sieci szeregowej RS485. Sygnały pomiarowe są źródłem danych dla środowiska SCADA. Pierwszy etap rozwoju był związany z wyborem urządzeń pomiarowych i budowy sieci szeregowej. Autorzy opisali również jak wprowadzić dane do sieci TCP / IP. W pierwszej części artykułu przedstawiono centralę klimatyzacyjną jako obiekt monitoringu. Następnie autorzy opisali podstawy teoretyczne, które są potrzebne dla obliczania wydajności chłodniczej, grzewczej i efektywności odzysku ciepła w centrali. Po tym została omówiona struktura systemu z wybranymi szczegółami odnośnie integracji sprzętowej i implementacji oprogramowania SCADA. W końcowej części zostały przedstawione wybrane zrzuty ekranu, aby pokazać typowe tryby pracy centrali oraz skuteczność opracowanego systemu monitorującego.
In the article a monitoring system of the Air Handling Unit (AHU) was presented. This system consists of several measurement elements e.g. (pressure, temperature, humidity, energy, etc. sensors) connected using a serial RS485 network. A measurement level is a source of data for a SCADA environment. The first stage of the development was related to the selection of measurement devices and a construction of the serial network. Authors also described how to introduce the data into TCP/IP network. In the first part of the article the AHU was presented as a subject of the monitoring. Then authors described a theoretical background, which is needed for a calculation of cooling and heating capacity, heat recovery efficiency. After that a structure of the system was presented with selected details about a hardware integration and a SCADA software implementation. In the final part several screenshots were presented to show typical working modes of the AHU and to proof efficiency of the developed monitoring system.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2016, 17, 12; 1144-1148
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessing the applicability of new refrigerants in marine cooling systems
Autorzy:
Zakrzewski, B.
Łokietek, T.
Powiązania:
https://bibliotekanauki.pl/articles/259543.pdf
Data publikacji:
2010
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
TEWI
ODP
GWP
heat pump
air conditioning
cooling installations
refrigerant
R22 substitute
energetic efficiency
R41
R152a
R218
R227ea
RC318
R600a
R290
R1270
Opis:
The article assesses the applicability of new refrigerants, being possible substitution for Freon 22, in marine refrigeration and air-conditioning systems. A collection of technical data on the physical properties of the new refrigerants is presented. Suggestions are made about certain energetic and ecological profits which can be gained when using energetically efficient refrigerants with low GWP values. The results of the TEWI comparison analysis for selected refrigerants are also included.
Źródło:
Polish Maritime Research; 2010, 2; 55-59
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ wycieku ziębnika na efektywność ziębniczą transportowej instalacji klimatyzacji
The impact of refrigerant leakage on the efficiency of the mobile air-conditioning system
Autorzy:
Łokietek, T.
Hillenberg, A.
Piotrowicz, A.
Powiązania:
https://bibliotekanauki.pl/articles/313522.pdf
Data publikacji:
2016
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
klimatyzacja samochodowa
ziębnik
efektywność ziębnicza
car air conditioning
refrigerant
refrigeration efficiency
Opis:
W artykule przedstawiono wyniki analizy wpływu wycieku ziębnika na efektywność ziębniczą samochodowych urządzeń klimatyzacyjnych. Za miarę takiego wpływu przyjęto zmianę wydajności chłodniczej, współczynnika COP oraz wartości dodatkowego zużycia paliwa dla instalacji klimatyzacji o poziomie wycieku w zakresie 0-40%.
Paper discussed the results of the analysis of the impact of refrigerant leakage on energy efficiency of a mobile air conditioning system. As a measure of such an effect, it was adopted the change of cooling capacity, COP, and the additional fuel consumption for the air conditioning system with the level of leakage in the range of 0-40%.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2016, 17, 6; 979-982
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies