Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "water-air system" wg kryterium: Wszystkie pola


Wyświetlanie 1-20 z 20
Tytuł:
Scaling of two-phase capillary pressure-saturation relationships: water-air and oil-air systems
Autorzy:
Kodesova, R.
Kutilek, M.
Vesela, J.
Matula, S.
Powiązania:
https://bibliotekanauki.pl/articles/25411.pdf
Data publikacji:
2003
Wydawca:
Polska Akademia Nauk. Instytut Agrofizyki PAN
Tematy:
interfacial tension
oil-air system
capillary pressure-saturation relationship
ground water
immiscible phase
water-air system
soil contamination
non-aqueous phase liquid
Źródło:
International Agrophysics; 2003, 17, 4
0236-8722
Pojawia się w:
International Agrophysics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dust control with use of air-water spraying system
Redukcja zapylenia powietrza z wykorzystaniem zraszania powietrzno-wodnego
Autorzy:
Prostański, D.
Powiązania:
https://bibliotekanauki.pl/articles/218814.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
redukcja zapylenia
zapylenie
zraszanie
zraszanie powietrzno-wodne
zagrożenia naturalne
airborne dust control
airborne dust
spraying system
air-and-water spraying system
natural hazards
Opis:
Results from testing the dust control efficiency, when using air-water spraying system in comparison to the typical water spraying system are presented in the paper. The tests were carried out in conditions of longwall mining and at the places of run-of-mine transportation. Also the results of stand tests of different types of nozzles both for air-water and for water spaying systems carried out at KOMAG’s laboratory and in real conditions are presented. The benefits resulting from air-water spraying system have been determined.
W artykule przedstawiono wyniki badań skuteczności redukcji zapylenia z wykorzystaniem zraszania powietrzno-wodnego w odniesieniu do zraszania wodnego. Badania przeprowadzono w warunkach technologii eksploatacji węgla systemem ścianowym oraz w miejscu odstawy urobku. Zaprezentowano również wyniki badań stanowiskowych różnego typu dysz zraszających, zarówno dla zraszania powietrzno-wodnego, jak i wodnego, które przeprowadzono w laboratorium ITG KOMAG oraz w warunkach rzeczywistych. Określono efekty wynikające ze stosowania zraszania powietrzno-wodnego.
Źródło:
Archives of Mining Sciences; 2012, 57, 4; 975-990
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modernizacja ogrzewania domu jednorodzinnego na ogrzewanie powietrzne
Modernization of a single-pipe water heating system into an air heating system in a single family house
Autorzy:
Gładyszewska-Fiedoruk, K.
Bobryk, T.
Powiązania:
https://bibliotekanauki.pl/articles/402737.pdf
Data publikacji:
2017
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
ogrzewanie budynków
ogrzewanie powietrzne
ogrzewanie alternatywne
heating of buildings
air heating
alternative heating
Opis:
W artykule omówiono możliwości modernizacji lub inwestycji dotyczących ogrzewania domów jednorodzinnych. Porównano ogrzewanie nadmuchowe (powietrzne), ogrzewanie grzejnikowe oraz ogrzewanie płaszczyznowe pod względem nośników energii, elementów grzejnych, bezwładności układu, awaryjności, kosztów eksploatacji, wpływu na estetykę wnętrz oraz możliwość rozbudowy o funkcje wentylacji i klimatyzacji. Podano również alternatywne urządzenia wspomagające ogrzewanie domu, takie jak: gruntowe wymienniki ciepła oraz kolektory słoneczne. Omówiono wykonany projekt ogrzewania domu jednorodzinnego ogrzewaniem powietrznym z wykorzystaniem pieca nadmuchowego i centrali wentylacyjnej z odzyskiem ciepła za pomocą GWC. Zaprojektowano także współpracę instalacji wywiewnej z okapem kuchennym. Jako system podgrzewu ciepłej wody użytkowej zaproponowano instalację solarną z pojemnościowym podgrzewaczem. W artykule podano również koszty inwestycyjne oraz eksploatacyjne dla zaproponowanego rozwiązania. Celem artykułu było omówienie zagadnień oraz przepisów dotyczących ogrzewania nadmuchowego oraz odzysku ciepła za pomocą gruntowych wymienników ciepła. Ponadto celem było zaprezentowanie wykonanych rozwiązań i wskazanie zasadności stosowania ogrzewania nadmuchowego w domach jednorodzinnych.
The paper shows the possibility of modernization of the heating systems in single family houses. The air heating was compared with a radiator heating and underfloor heating in terms of energy sources, heating systems elements, inertia of system, failure rates, costs, an impact on the aesthetics of the interior area and the possibility of expansion of the functions for the ventilation and air-conditioning systems. Moreover the alternative ways for heating such as ground heat exchangers and solar collectors were described. The project for a single-family home heating were presented. It was an air heating using the air handling unit with heat recovery and the ground exchangers. The exhaust ventilation cooperated with a cooker hood. For a DHW system solar installation with DHW tank was proposed. The paper also stated capital and operating costs for the proposed solution.
Źródło:
Budownictwo i Inżynieria Środowiska; 2017, 8, 3; 113-122
2081-3279
Pojawia się w:
Budownictwo i Inżynieria Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the Effects of the Water-Flat-Panel Illuminator-Air Optical System on the Size of the Photographed Object
Ocena wpływu układu optycznego woda-iluminator płaskorównoległy-powietrze na wielkość obiektu obfotografowanego
Autorzy:
Sokół, Łukasz
Olejnik, Adam
Powiązania:
https://bibliotekanauki.pl/articles/32717198.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Medycyny i Techniki Hiperbarycznej
Tematy:
mechanical engineering
underwater technology
underwater engineering photogrammetry
inżynieria mechaniczna
technologia prac podwodnych
podwodna fotogrametria inżynieryjna
Opis:
The paper discusses the problem of the effect of the water - flat-panel illuminator - air optical system on the size of an object photographed in an underwater environment as well as presents an analysis of the function describing the angular size of an object photographed with this type of system along with the results of computer simulations. It has been shown that when using this type of an optical system in practice, the value of the angle of incidence of the rays from the photographed object on the illuminator plane has the major influence on output object dimensions.
W materiale omówiono problematykę wpływu układu optycznego woda - iluminator płaskorównoległy - powietrze na wielkość obiektu obfotografowanego w środowisku podwodnym, przedstawiono analizę funkcji opisującej wielkość kątową obiektu obfotografowanego takim układem oraz wyniki symulacji komputerowych. Wskazano, że przy zastosowaniu takiego typu układu optycznego w praktyce największy wpływ na wielkość wyjściową ma wartość kąta padania promieni od fotografowanego obiektu na płaszczyznę iluminatora.
Źródło:
Polish Hyperbaric Research; 2021, 3(76); 7-20
1734-7009
2084-0535
Pojawia się w:
Polish Hyperbaric Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Daily water demand variations in the Bialystok water distribution system in light of chosen economic and environmental conditions
Autorzy:
Kolendo, M.
Powiązania:
https://bibliotekanauki.pl/articles/96587.pdf
Data publikacji:
2018
Wydawca:
Fundacja Ekonomistów Środowiska i Zasobów Naturalnych
Tematy:
water demand irregularity
daily water use
air temperature
rainfall
water price
nieregularność popytu na wodę
codzienne zużycie wody
temperatura powietrza
opad deszczu
cena wody
Opis:
The study presents the analysis of water consumption in Bialystok in north-eastern Poland in the years 2007–2013. It has been shown in the study that demand for water during a week is varying and it fluctuates. A detailed analysis of water consumption on individual days of the week and public holidays is presented. Individual consumption per capita and daily water consumption irregularity coefficients were estimated. In the analysed period, the highest average daily water demand was recorded on Saturdays (43,129 m3 ), and the lowest on Sundays (37,712 m3 ). Moreover, the impact of economic and environmental factors on the process under study has been characterized in the study. In Bialystok, the price of water increased by 42% in the years 2007-2013, with the inflation rate in the country at 119.2% in those years. It is also presented the influence of maximum daily temperature and precipitation sum on daily water consumption on working days and Saturdays, as well as separately, on Sundays and public holidays.
Źródło:
Ekonomia i Środowisko; 2018, 2; 168-179
0867-8898
Pojawia się w:
Ekonomia i Środowisko
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu czynników meteorologicznych na zmienność poboru wody w miejskim systemie wodociągowym
Analysis of influence of meteorological factors on water demand variations in municipal water supply system
Autorzy:
Hotloś, H.
Powiązania:
https://bibliotekanauki.pl/articles/236902.pdf
Data publikacji:
2013
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
water supply
air temperature
rainfall
zaopatrzenie w wodę
temperatura powietrza
opad atmosferyczny
Opis:
Analysis of variations in daily water demand in relationship to meteorological factors, i.e. air temperature and rainfall intensity, was carried out for the city of Wroclaw and the year 2011. 60% of water pumped into the supply system was consumed by households, 22% was used for other communal purposes, while 18% constituted water utilized by the system itself as well as water loss. Studies of the relationship between water demand and meteorological factors were performed for individual months, when the number of residents was almost constant. The relationship, in numbers, between water demand and air temperature (average and maximum) as well as rainfall intensity was estimated separately for working days (including Saturdays) and non-working days (Sundays and holidays). The statistical analysis performed implies strong influence of maximum daily air temperature on daily water demand in summer months (from May until August). Water uptake in May, June and July on days with the highest maximum temperature was higher by 11.8%, 11.1% i 13.3% respectively, than on days with the lowest maximum temperature. A noticeable influence of rainfall intensity on decrease in water demand was identified on working days in June, the warmest and the driest month in the analyzed year.
Przeprowadzono analizę zmian dobowego poboru wody we Wrocławiu w 2011 r. w zależności od czynników meteorologicznych, tj. temperatury powietrza i wysokości opadów atmosferycznych. Prawie 60% z ilości wody wtłoczonej do sieci wodociagowej po-brano na potrzeby gospodarstw domowych, 22% na pozostałe cele komunalne, a 18% sta-nowiła woda zużyta na potrzeby własne systemu wodno-ściekowego oraz straty wody. Badania związków między poborem wody a czynnikami meteorologicznymi przeprowadzono w poszczególnych miesiącach, kiedy liczba mieszkańców była prawie stała. Liczbowe zależności między poborem wody a temperaturą powietrza (średnią i maksymalną) i wysokością opadów atmosferycznych określono oddzielnie w dniach roboczych (z sobotami) oraz wolnych od pracy (niedziele i święta). Z dokonanej analizy statystycznej wynika, że istnieje bardzo wyraźny wpływ maksymalnej dobowej temperatury powietrza na dobowy pobór wody w miesiącach letnich (od maja do sierpnia). W dniach o największej temperaturze maksymalnej w maju, czerwcu i lipcu pobór wody był odpowiednio o 11,8%, 11,1% i 13,3% większy niż w dniach o najmniejszej temperaturze maksymalnej w tych miesiącach. Zauważalny wpływ wysokości opadów deszczu na zmniejszenie poboru wody stwierdzono w dniach roboczych w czerwcu, który był najcieplejszym i najbardziej suchym miesiącem w analizowanym roku.
Źródło:
Ochrona Środowiska; 2013, 35, 2; 57-62
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Założenia technologiczne systemu sterowania procesami koagulacji i flotacji ciśnieniowej w układzie oczyszczania wody
Technological assumptions of coagulation and dissolved air flotation control system in water treatment process
Autorzy:
Kłos, M.
Powiązania:
https://bibliotekanauki.pl/articles/237854.pdf
Data publikacji:
2013
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
water treatment
turbidity
water quality
process control
oczyszczanie wody
mętność
absorbancja w nadfiolecie
sterowanie
Opis:
Based on technical and laboratory scale study results, design recommendations for coagulation and dissolved air flotation control system in water treatment train with high quality variability were presented. Hydrolyzing coagulants, when applied, were demonstrated to require fluent rotational stirrer speed regulation in flocculators. This allows maintenance of adequate floc size which determines bubble-floc agglomerate formation efficacy and their resistance to mechanical tension in the contact zone of flotation tank. In practice, real time rotation regulation in flocculators might be applied, depending on water turbidity or particle number in water fraction leaving flotation tank. Required recirculation factor might be estimated in real time, based on the clarified water quality. However, this solution is very difficult to implement due to many factors that affect efficiency of coagulation and dissolved air flotation processes. It was demonstrated that special attention should be paid to differentiation between the effect of inadequate coagulant dose and the improper recirculation factor. Use of information on the amount and type of suspensions in the intake water, obtained based on UV-absorbance and turbidity measurements, appears to be a better approach.
Na podstawie wyników badań wykonanych w skali laboratoryjnej i technicznej przedstawiono zalecania do projektowania systemu sterowania koagulacją i flotacją ciśnieniową w układzie oczyszczania wody o dużej zmienności jakościowej. Wykazano, że w przypadku stosowania koagulantów hydrolizujących konieczne jest zastosowanie płynnej regulacji prędkości obrotowej mieszadeł w komorach flokulacji. Pozwala to na utrzymanie odpowiedniej wielkości kłaczków, od czego zależy skuteczność powstawania aglomeratów flotacyjnych oraz ich wytrzymałość na naprężenia mechaniczne występujące w strefie kontaktu komory flotacji. W praktyce możliwe jest zastosowanie regulacji obrotów w komorach flokulacji w czasie rzeczywistym w zależności od mętności wody lub liczby cząstek w wodzie opuszczającej komorę flotacji. Wartość wymaganego stopnia recyrkulacji może być określana w czasie rzeczywistym w oparciu o jakość wody sklarowanej. Jednak jest to rozwiązanie bardzo trudne w realizacji z uwagi na to, że na sprawność działania procesów koagulacji i flotacji ciśnieniowej wpływa zbyt wiele czynników. Wykazano, że szczególną uwagę należy zwrócić na rozgraniczenie wpływu nieodpowiedniej dawki koagulantu oraz niewłaściwego stopnia recyrkulacji. Wydaje się, że lepszym rozwiązaniem jest wykorzystanie informacji o ilości i rodzaju zawiesin obecnych w ujmowanej wodzie, uzyskanych na drodze pomiaru absorbancji w nadfiolecie i mętności.
Źródło:
Ochrona Środowiska; 2013, 35, 3; 39-43
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Controlling the distribution of cold water in air cooling systems of underground mines
Regulacja i sterowanie parametrami wody lodowej w instalacjach klimatyzacyjnych kopalń podziemnych
Autorzy:
Szlązak, N.
Obracaj, D.
Swolkień, J.
Piergies, K.
Powiązania:
https://bibliotekanauki.pl/articles/219050.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
klimatyzacja kopalń podziemnych
regulacja
sterowanie
woda lodowa
chłodnice powietrza
underground mines
air cooling systems
water reticulation system
automatic control
Opis:
In Polish underground mines in which excavations are subjected to high heat load, central and group cooling systems based on indirect cooling units are implemented. Chilled water, referred to as cold water and produced in chillers, is distributed through a pipeline network to air coolers located in mining and development districts. The coolers are often moved to other locations and the pipeline network undergoes constant modification. In such a system, parameters of cold water in different branches of the pipeline network need to be controlled. The article presents the principles for controlling the cooling capacity of air coolers installed in an underground mine. Also, the authors propose automatic control of water flow rate in underground pipeline network and in particular coolers, depending on the temporary cooling load in the system. The principles of such a system, controlling cold water distribution, and the functions of its individual components are described. Finally, an example of an automatic control of water flow rate in a central cooling system currently implemented in a mine is presented.
W polskich kopalniach podziemnych o dużym obciążeniu cieplnym wyrobisk stosuje się systemy klimatyzacji grupowej i centralnej, projektowane w oparciu o urządzenia chłodnicze pośredniego działania. Wytwarzana w agregatach chłodniczych woda lodowa rozprowadzana jest siecią rurociągów do chłodnic powietrza w rejonach eksploatacyjnych i przygotowawczych. Chłodnice są często przebudowywane, a sieć rurociągów ulega ciągłej zmianie. Obieg wody w sieci rurociągów wymaga ciągłej regulacji w za kresie wymaganego natężenia przepływu wody lodowej w poszczególnych odgałęzieniach sieci rurociągów. W artykule przedstawiono zasady regulacji wydajności chłodnic powietrza. Zaproponowano układ automatycznego sterowania rozpływem wody lodowej w sieci, jaką tworzą rurociągi i chłodnice powietrza, w zależności od chwilowego zapotrzebowania mocy w chłodnicach. Omówiono zasady takiej regulacji oraz funkcje, jakie muszą spełniać poszczególne elementy układu sterowania rozpływem wody lodowej. Przedstawiono przykład wdrażanego aktualnie sterowania rozpływem wody lodowej w klimatyzacji centralnej.
Źródło:
Archives of Mining Sciences; 2016, 61, 4; 793-807
0860-7001
Pojawia się w:
Archives of Mining Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Innowacyjny system zraszania dla wyrobisk ścianowych
Innovative spraying system for longwall panels
Autorzy:
Bałaga, D.
Siegmund, M.
Prostański, D.
Kalita, M.
Powiązania:
https://bibliotekanauki.pl/articles/198924.pdf
Data publikacji:
2016
Wydawca:
Instytut Techniki Górniczej KOMAG
Tematy:
górnictwo
zagrożenia naturalne
zapylenie
zraszanie powietrzno-wodne
mining industry
natural hazards
airborne dust
air-and-water spraying
Opis:
W artykule przedstawiono innowacyjny system zraszania typu KOMAG, przeznaczony do ograniczania zapylenia generowanego podczas urabiania kombajnami w systemach ścianowych. Zaprezentowano jego budowę, parametry pracy oraz zasadę działania. Omówiono wyniki badań jego skuteczności działania przeprowadzonych w warunkach rzeczywistych.
Innovative spraying system of KOMAG type, designed for reduction of airborne dust generated during longwall shearer operation in longwall panel is presented. Design of the spraying system, its operational parameters and principle of operation are described. The effectiveness of its operation in real conditions is discussed.
Źródło:
Maszyny Górnicze; 2016, 34, 3; 14-22
0209-3693
2450-9442
Pojawia się w:
Maszyny Górnicze
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wskaźnik efektywności COP systemu klimatyzacji z wykorzystaniem wód gruntowych
COP effectiveness indicator for an air-conditioning system using ground water
Autorzy:
Dąbrowska, K.
Dąbrowski, T.
Powiązania:
https://bibliotekanauki.pl/articles/162581.pdf
Data publikacji:
2009
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
klimatyzacja
woda gruntowa
pompa ciepła
wydajność chłodnicza
efektywność kosztowa
air-conditioning
groundwater
heat pump
refrigeration efficiency
cost efficiency
Opis:
Na polskim rynku można kupić różnego rodzaju systemy klimatyzacyjne. Firmy chłodnicze prześcigają się oferując coraz to nowsze, sprawniejsze i bardziej ekonomiczne klimatyzacje. Chociażby tradycyjne freonowe klimatyzatory typu Split, fan-coile, w których agregaty wody lodowej wytwarzają czynnik chłodniczy, czy pompy ciepła z dolnym źródłem. W 2007 roku inż. Tomasz Dąbrowski, absolwent Akademii Techniczno-Rolniczej w Bydgoszczy, zgłosił w Urzędzie Patentowym RP opracowany przez siebie nowy system ekologicznej klimatyzacji, którego głównym czynnikiem chłodniczym są wody gruntowe, czyli naturalne źródło energii.
Various types of air-conditioning systems are available in Poland. Firms compete by offering ever more modern, effective and economical air-conditioners, whether the traditional freon-based split-type devices, fan-coils where ice-water units produce a refrigerant, or heat pumps with lower heat source. In 2007 Tomasz Dąbrowski, an engineering graduate of the University of Technology and Life Sciences in Bydgoszcz, submitted to the Polish Patent office his invention of a new environmentally friendly system of air-conditioning where the main refrigerant is ground water, thus providing a natural energy source.
Źródło:
Przegląd Budowlany; 2009, R. 80, nr 7-8, 7-8; 61-63
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The analysis of possible methods of providing fresh water for sailing vessels based on the example of s/v Dar Młodzieży
Autorzy:
Giernalczyk, M.
Herdzik, P.
Powiązania:
https://bibliotekanauki.pl/articles/242535.pdf
Data publikacji:
2013
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
sailing vessel
air conditioning system
vaporizer
osmotic desalinator
Opis:
In this paper the possibilities of providing fresh water for sailing vessels based on the example of s/v Dar Modziey are presented. Different methods of obtaining fresh water such as rainwater harvesting, replenishing water tanks at harbours, collecting condensed water from air conditioning systems or producing fresh water from seawater by means of desalination equipment were considered. Vacuum vaporizers (heated by fresh water used as a cooling medium of the main propulsion engines) and osmotic desalinators (using the phenomenon of reverse osmosis) were being taken under consideration. Special focus was put on the quality of water obtained; comparing the methods mentioned and pursuing the best solution both in technical and economic terms. The choice of desalinators was preceded by the analysis of quantity and configuration of pumps and membranes that will guarantee optimum performance. Selection of the manufacturer was determined by costs of purchase, costs of operation and the availability of spare parts and consumables. The osmotic desalinator ended up as the final choice of fresh water producing device on s/v Dar Modziey. Excessive water consumption can be satisfied by replenishing supplies at ports. The paper is concluded with comments and suggestions that can be adapted by a ship owner as a solution for the problem of supplying vessels with fresh water.
Źródło:
Journal of KONES; 2013, 20, 1; 95-102
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Matematyczny opis pracy układu górnicza chłodziarka sprężarkowa – wyparna chłodnica wody
Mathematical description of the mining compression refrigerator – evaporating water cooler operating system
Autorzy:
Nowak, B.
Filek, K.
Powiązania:
https://bibliotekanauki.pl/articles/166913.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Górnictwa
Tematy:
chłodzenie powietrza
klimatyzacja kopalń
chłodziarka sprężarkowa
chłodnica wyparna
czynnik chłodniczy
air cooling
mine air conditioning
compression refrigerator
evaporative cooler
refrigerant
Opis:
Bazując na swoich wcześniejszych pracach autorzy artykułu podają układy równań opisujące rzeczywiste procesy fizyczne zachodzące w stanie ustalonym w pracujących górniczych sprężarkowych chłodziarkach powietrza o działaniu bezpośrednim lub pośrednim połączonych z wyparną chłodnicą wody. W opisach matematycznych rozróżniono pracę: wodnej chłodnicy powietrza, parownika, skraplacza, sprężarki, zaworu rozprężnego i wyparnej chłodnicy wody, uwzględniono także ewentualną pracę dochładzacza. Rozwiązanie podanych układów równań, ze względu na ich stopień skomplikowania i występujące w nich nieliniowości, jest możliwe tylko na drodze numerycznej. Korzystając z utworzonego programu komputerowego wykonano przykładowe obliczenia parametrów fizycznych mediów biorących udział w wymianie ciepła przy chłodzeniu bezpośrednim z dochładzaczem oraz chłodzeniu pośrednim bez dochładzacza. Obliczono także moce cieplne poszczególnych elementów tworzących rozważane systemy chłodnicze. Każdy z nich współpracuje z chłodnicą wyparną.
Basing of the papers previously written by the authors, this paper presents a system of equations of the real physical processes occurring in the steady state of operating mining compression refrigerators with evaporating water cooler acting directly or indirectly. Mathematical description of the following operating components was distinguished: water air-cooler, evaporator, condenser, compressor, expansion valve, evaporating water cooler, and potential subcooler. Only a numerical solution is presented due to the complexity and nonlinearity of the given equations. This paper also shows an example of numerical calculations of the physical parameters of the media taking part in the heat exchange process under direct cooling with the use of the subcooler and under indirect cooling without the subcooler. Thermal power of each component of the system under consideration was estimated. Each system cooperates with the evaporating water cooler.
Źródło:
Przegląd Górniczy; 2014, 70, 10; 155-163
0033-216X
Pojawia się w:
Przegląd Górniczy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Technical and economic evaluation of a heating system based on air-to-water heat pumps with photovoltaic - micro-installation within the Prosument program
Ocena techniczno-ekonomiczna systemu grzewczego opartego na pompach ciepła typu powietrze woda współpracującego z mikroinstalacją fotowoltaiczną w ramach programu Prosument
Autorzy:
Szul, T.
Powiązania:
https://bibliotekanauki.pl/articles/334685.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Maszyn Rolniczych
Tematy:
final energy consumption
building
air-water heat pump
PV micro-installation
Prosumer program
economic analysis
zużycie energii końcowej
budynek
pompa ciepła typu powietrze-woda
mikroinstalacja PV
program Prosument
analiza ekonomiczna
Opis:
For an exemplary single-family residential building, final energy consumption for heating and domestic hot water preparation was calculated using an air / water heat pump, consumption of electricity for household purposes (lighting, household appliances, RTV, etc.) was also calculated as based on statistical summaries. On this basis, power was selected and the annual production volume was determined by a photovoltaic micro-installation working in the ON-GIRD system pursuant to prosumer regulations contained in the Act on Renewable Energy. Then, an economic analysis was carried out basing on such static and dynamic methods as SPBT, PBP, NPV, IRR and CCE. The calculations were made for two variants, i.e.: the investment costs of the system are borne entirely by the investor, or the installation is purchased within the "EKOkredyt Prosument II" NFEP&WM program. As a result of the calculations, it was found that the investment in PV microinstallation will be profitable only if the support instruments offered by the NFEP&WM program are used. If the investor uses co-financing, the investment will pay back within 16 years at the latest and if he wants to invest his own funds, the waiting period for the return on investments can be extended to up to 21 years, which, given the twenty-five year period of operation, can turn out to be the risk that the funds invested can never be returned.
Dla przykładowego budynku mieszkalnego jednorodzinnego obliczono zużycie energii końcowej do ogrzewania i przygotowania ciepłej wody użytkowej za pomocą pompy ciepła typu powietrze/woda. Określono również w oparciu o zestawienia statystyczne wielkość zużycia energii elektrycznej na cele bytowe (oświetlenie, AGD, RTV, itp.) Na tej podstawie dobrano moc i określono roczną wielkość produkcji przez mikroinstalację fotowoltaiczną pracującą w systemie ON-GIRD w ramach przepisów dotyczących prosumentów zawartych w ustawie o OZE. Następnie przeprowadzono analizę ekonomiczną w oparciu o metody statyczne i dynamiczne takie jak: SPBT, PBP, NPV, IRR oraz CCE. Obliczenia wykonano dla dwóch wariantów, tj.: koszty inwestycyjne systemu ponoszone są w całości przez inwestora lub instalacja jest zakupiona w ramach programu NFOŚiGW „EKOkredyt Prosument II”. W wyniku przeprowadzonych obliczeń stwierdzono, że inwestycja w mikroinstalację PV będzie opłacalna jedynie w przypadku skorzystania z instrumentów wsparcia oferowanych przez program NFOŚiGW. Jeżeli inwestor skorzysta z dofinansowania to inwestycja zwróci się najpóźniej w ciągu 16 lat, natomiast jeżeli będzie chciał zainwestować środki własne okres oczekiwania na zwrot nakładów może wydłużyć się nawet do 21 lat, co przy zakładanym dwudziestopięcioletnim okresie eksploatacji może okazać się, że inwestycja ta będzie niosła za sobą ryzyko, iż zainwestowane środki mogą się nie zwrócić.
Źródło:
Journal of Research and Applications in Agricultural Engineering; 2018, 63, 4; 197-202
1642-686X
2719-423X
Pojawia się w:
Journal of Research and Applications in Agricultural Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement of air-water oxygen transfer of cylindrical vortex flow regulators at a recirculating system
Autorzy:
Wójtowicz, P.
Szlachta, M.
Kotowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/208207.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
hydrodynamics
storms
vortex flow
aeration efficiencies
hydrodynamic flows
oxygen mass transfer
oxygen transfer rate
recirculating system
stormwater systems
sewerage
oxygen
hydrodynamika
burze
wiry
efektywność napowietrzania
przepływy hydrodynamiczne
przenoszenia masy tlenu
szybkość transferu tlenu
system recyrkulacji
systemy deszczowe
kanalizacja
napowietrzanie
Opis:
Hydrodynamic flow regulators are used for diversion and/or limiting excess discharge in wastewater and stormwater systems as a replacement for traditional flow throttling devices. They are highly efficient, reliable and free from common disadvantages of traditional devices. Recent research of the authors indicated that atomization of a liquid by vortex flow regulators accelerates oxygenation and prevents the putrefaction process in wastewater and storm water collection systems. The study presents experimental results of the oxygen transfer measurements for basic designs of cylindrical hydrodynamic flow regulators in a closed-circuit experimental setup at the semi-commercial scale. The oxygen mass transfer coefficient, standard oxygen transfer rate and standard aeration efficiency were determined for the range of tested configurations by the clean water test.
Źródło:
Environment Protection Engineering; 2013, 39, 3; 207-215
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza stosunków powietrzno-wodnych gleby torfowo-murszowej w zasięgu działania systemu nawodnień podsiąkowych
The analysis of moisture regime in peat-muck soil profile withen the range of sub-irrigation system
Autorzy:
Oleszczuk, R.
Chrzanowski, S.
Gnatowski, T.
Powiązania:
https://bibliotekanauki.pl/articles/338176.pdf
Data publikacji:
2012
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
funkcjonowanie systemu melioracyjnego
gleby torfowo-murszowe
stosunki powietrzno-wodne
zapasy wody
air-moisture conditions
peat-muck soils
sub-irrigation system
water storage
Opis:
W pracy przedstawiono rozkład stosunków powietrzno-wodnych w profilu gleby torfowomurszowej znajdującej się w zasięgu oddziaływania systemu nawodnień podsiąkowych, na podstawie badań przeprowadzonych w okresie wegetacji w 2006 r. (kwatera Biebrza 29, torfowisko Kuwasy - środkowy basen Biebrzy). Zapasy wody zarówno w strefie korzeniowej (0-30 cm), jak i w całym analizowanym profilu (0-100 cm) wykazywały podobną dynamikę zmian i różniły się między sobą o około 600 mm. Stwierdzono skuteczne działanie systemu melioracyjnego, niemniej w przypadku bardzo niskich (lipiec 2006) lub ekstremalnie wysokich opadów atmosferycznych (sierpień 2006) pojawiły się okresowe przekroczenia stanów granicznych zwierciadeł wody gruntowej, natomiast wartości ciśnień ssących w strefie korzeniowej były jedynie nieco większe od przyjętych norm na początku i końcu rozpatrywanego okresu wegetacji.
The paper presents an assessment of sub-irrigation system operating in peat-muck soil within Biebrza 29 site (Kuwasy peatland located in the Middle Biebrza River Basin). Performed measurements of surface water levels in open ditches and the levels of groundwater showed effective functioning of the existing sub-irrigation system. In extremely dry or wet conditions some too low or too high groundwater levels were observed. Water reserves in both root zone and in the whole soil profile showed similar dynamics and differed between each other by almost 600 mm.
Źródło:
Woda-Środowisko-Obszary Wiejskie; 2012, 12, 1; 93-104
1642-8145
Pojawia się w:
Woda-Środowisko-Obszary Wiejskie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efektywność sprężarkowej pompy ciepła powietrze-woda po modernizacji układu kierowniczego dolnego źródła ciepła
Efficiency of compressor heat pump (air-water) after modernisation of guiding system for lower heat source
Autorzy:
Knaga, J.
Powiązania:
https://bibliotekanauki.pl/articles/291636.pdf
Data publikacji:
2009
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
energia
pompa ciepła
źródło ciepła
współczynnik efektywności energetycznej
badanie eksploatacyjne
energy
heat pump
heat source
energy efficiency coefficient
performance test
Opis:
W pracy przedstawiono wyniki badań eksploatacyjnych małej sprężarkowej pompy ciepła OW 150 typu powietrze-woda, przeznaczonej do przygotowania ciepłej wody użytkowej, po przeprowadzonej modernizacji układu kierowniczego na dolnym źródle ciepła. Przeprowadzona szczegółowa analiza wyników badań pokazała, iż współczynnik efektywności energetycznej zmienia się w granicach 1,45-3,45 (przy wartości przeciętnej 2,05) w czasie cyklu nagrzewania wody w zasobniku. Ponadto badania prowadzone w warunkach eksploatacyjnych po modernizacji układu kierowniczego dolnego źródła ciepła, wskazują na istotny wzrost efektywności energetycznej o 11% w odniesieniu do badań wstępnych.
The paper presents results of performance tests carried out for small compressor heat pump (OW 150), air-water type, designed for preparing hot utility water, after completed modernisation of guiding system in lower heat source. Detailed analysis of test results has proven that during water heating cycle in water tank the energy efficiency coefficient value ranges from 1.45 to 3.45 (mean value is 2.05). Moreover, tests performed in service conditions after modernisation of lower heat source guiding system indicate significant increase in energy efficiency by 11%, compared to preliminary tests.
Źródło:
Inżynieria Rolnicza; 2009, R. 13, nr 6, 6; 141-147
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena efektu ekologicznego wynikającego z zastosowania kolektorów słonecznych
Assessment of the Environmental Effects Resulting from the Use of Solar Collectors
Autorzy:
Żukowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/1818047.pdf
Data publikacji:
2016
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
kolektory słoneczne
podgrzewanie wody użytkowej
odnawialne źródła energii
zanieczyszczenia powietrza
pakiet klimatyczno-energetyczny
systemy solarne
solar collectors
solar domestic
hot water system
renewable energy sources
air pollutants
climate and energy package
Opis:
Climate and energy package is a set of rules designed by member states of European Union to combat climate change. According to these directives the greenhouse gas emissions should be reduced by 20% and the share of energy produced from renewable sources should simultaneously be increased by the same percentage. The use of solar collectors can both improve energy security and reduce the environmental impact caused by the thermal energy industry. An ability to reduce the pollutants, which can be achieved using devices for converting solar radiation into the heat, was determined in this paper. The environmental effect, discussed in the present work, is caused by reducing the demand for domestic water heating. This effect results from the application of thermal solar collectors. The amount of pollutants that are released into the air, emitted from combustion of fuels, was estimated on the basis of the annual energy gain from the solar radiation and emission factors of the selected pollutants recommended by the European Environment Agency (EEA). Net gain of energy from solar panels was determined on the basis of experimental data. The object of the study was the solar domestic hot water (SDHW) system located on the roof of the Hotel for the staff of Bialystok University of Technology (Poland). Experimental studies were carried out under the project financed by the Regional Operational Program of Podlasie Province – stage 1.1 named “Study of the effectiveness of active and passive methods to improve the energy efficiency of infrastructure supported by renewable energy sources”. The construction of the research object was the target of the stage – 5.2 named “Improving the energy efficiency of Bialystok University of Technology infrastructure by use of renewable energy sources” (V. Development of environmental protection infrastructure”). The system consists of two parallel-connected installations. The first includes 21 tube collectors with a total gross area of more than 74 m2. The second unit consists of 35 flat plate collectors with a total gross area of about 72 m2. Eight storage tanks with the capacity of 1000 liters each were placed in the basement of the Hotel. The monitoring system was used to record the installation parameters during its operation. It consists of 17 heat meters, 4 electricity recorders, and 42 platinum resistance temperature sensors. The weather station that captures the basic parameters of outside air and insolation is located near the solar collectors. As a result of studies, it was found that the solar system produced 230.61 GJ heat energy throughout the year. The equation necessary to determine an equivalent amount of energy that is produced in a power plant was presented in this paper. Subsequently, the value of a possible reduction of selected pollutant emissions, which are released into the air, was calculated. Moreover, ΔPj coefficients were proposed for determination of the emissions reduction related to 1 m2 gross area of a solar panel. The main conclusions from the assessment of the impact of applying SDHW system to reduce the air pollution in the urban area were presented at the end of the paper.
Źródło:
Rocznik Ochrona Środowiska; 2016, Tom 18, cz. 2; 284-293
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przegląd możliwości wykorzystania wybranego sprzętu ratowniczo-gaśniczego w działaniach jednostek ochrony przeciwpożarowej w kontekście wymagań systemu dopuszczeń
Review of the Potential Exploitation of Selected Firefighting and Rescue Equipment during Incidents Addressed by Fire Service Units in the context of Requirements Stipulated by the Admittance Process
Autorzy:
Kalinowska, J.
Chmiel, M.
Powiązania:
https://bibliotekanauki.pl/articles/373614.pdf
Data publikacji:
2015
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
motopompa pływająca
motopompa do wody zanieczyszczonej
turbopompa
działko wodno-pianowe
hydrauliczne narzędzie ratownicze
poduszki podnoszące
analiza
zastosowanie
eksploatacja
system dopuszczeń
dopuszczenie do użytkowania
floating pump
motopump for contaminated water
turbopump
water-foam monitor
hydraulic rescue tools
air cushions
analysis
application
exploitation
admittance system
admittance for use
Opis:
Cel: Celem głównym niniejszego artykułu jest opisanie budowy, zasady działania i możliwości wykorzystania najczęściej stosowanego sprzętu ratowniczo-gaśniczego oraz wskazanie praktycznych przykładów jego zastosowania w poszczególnych typach zdarzeń przez jednostki ochrony przeciwpożarowej RP. Wprowadzenie: Właściwy dobór sprzętu przez poszczególne jednostki gwarantuje skuteczne i szybkie prowadzenie działań, co przekłada się na poprawę bezpieczeństwa osób ratowanych, jak również minimalizację strat wynikających z poszczególnych zdarzeń. Przy dokonywaniu zakupu ww. sprzętu, z punktu widzenia ergonomii, bezpieczeństwa i funkcjonalności – ważne jest, aby wybierać urządzenia, które posiadają świadectwo dopuszczenia CNBOP-PIB wydane na podstawie rozporządzenia z dnia 27 kwietnia 2010 r. zmieniającego rozporządzenie w sprawie wykazu wyrobów służących zapewnieniu bezpieczeństwa publicznego lub ochronie zdrowia, życia lub mienia, a także zasad wydawania dopuszczenia tych wyrobów do użytkowania (Dz.U. nr 85, poz. 553). Artykuł przedstawia budowę, zasady działania oraz możliwości praktycznego wykorzystania sprzętu, będącego wyposażeniem jednostek ochrony przeciwpożarowej w kontekście wymagań w procesie dopuszczenia omawianego sprzętu. Przedstawiono i sklasyfikowano wyroby takie jak: motopompy przenośne i przewoźne, turbopompy, motopompy do wody czystej i zanieczyszczonej, motopompy pływające i działka wodno-pianowe. Wskazano także wyroby z zakresu sprzętu ratownictwa technicznego: hydrauliczne narzędzia ratownicze oraz poduszki wysoko- i niskociśnieniowe. Zwrócono również uwagę na podstawowe czynności z zakresu obsługi i konserwacji omawianego sprzętu. Metodologia: W artykule przeanalizowano literaturę przedmiotu. Treść opracowano w oparciu o standardy, publikacje i materiały szkoleniowe CNBOP-PIB z zakresu ratownictwa i sprzętu przeznaczonego dla straży pożarnej. Literaturę wzbogacono również o inne opracowania zwarte oraz rozporządzenie dotyczące systemu dopuszczeń w Polsce. Wnioski: W artykule skupiono się na wybranym sprzęcie stosowanym przez jednostki ochrony przeciwpożarowej. Przedstawiono jego budowę oraz główne obszary zastosowania. Zwrócono uwagę na konieczność przestrzegania zaleceń producenta w zakresie konserwacji i eksploatacji. Wskazano również na znaczenie systemu dopuszczeń w kontekście zapewnienia bezpieczeństwa ratowników oraz osób ratowanych, jak również w kwestii gwarancji jakości oraz kompatybilności wyposażenia jednostek ochrony przeciwpożarowej.
Aim: The main purpose of this article is to describe the construction, operating principles and possibilities of exploiting most commonly used firefighting and rescue equipment, and indicate practical examples of application during specific incidents addressed by firefighting units of the Polish State Fire Service. Introduction: Appropriate selection of equipment by Fire Service establishments guarantees effective and efficient conduct of operations, which ultimately results in a more effective provision of safety for rescued people as well as minimization of losses resulting from particular incidents. The acquisition process, apart from features concerned with ergonomics, safety and functionality, includes selection of equipment, which has received a certificate of admittance issued by CNBOP-PIB. Such certificates are awarded in accordance with regulations set by the Minister of the Interior on 27 April 2010, amending regulations, dealing with product specification intended to assure public safety or safeguarding of life, health and property and principles of approving such products for use (Journal of Laws No. 85 item 553). Equipment identified in this article is categorized as: portable and transportable moto pumps, turbopumps, pumps for clean and contaminated water, floating pumps and water-foam monitors. Additionally, equipment used in connection with road traffic accident rescue work is also included, such as: hydraulic rescue tools and air cushions for lifting (low and high pressure). Moreover, attention was drawn to the basic activities concerning operation and maintenance of relevant equipment. Methods: The authors carried out an analysis of literature on the topic. Content of the article is based on standards, publications and training materials issued by CNBOP-PIB on matters concerning rescue work and equipment intended for use by the Fire Service. Literature material was enhanced by other texts and post-conference publications, and regulation concerning the approval system in Poland. Conclusions: The article focused on selected equipment used by the Fire Service and described the construction of such equipment and main applications. Attention was drawn to the need for compliance with manufacturer’s recommendations during maintenance and operation of equipment. Additionally, the article indicated merits and significance of the admittance system in ensuring the safety of rescuers and those being rescued, as well as the issue of quality guarantee and compatibility of equipment used by the Fire Service.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2015, 4; 61-80
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza występowania dolegliwości i objawów ze strony układu oddechowego u osób zatrudnionych w przemyśle na stanowiskach pracy generujących aerozol wodny. Badania pilotażowe jakości mikrobiologicznej powietrza i wody technologicznej
Respiratory symptoms among industrial workers exposed to water aerosol. A pilot study of process water and air microbial quality
Autorzy:
Krogulska, Bożena
Matuszewska, Renata
Bartosik, Marta
Krogulski, Adam
Szczotko, Maciej
Maziarka, Dorota
Powiązania:
https://bibliotekanauki.pl/articles/2168407.pdf
Data publikacji:
2014-10-29
Wydawca:
Instytut Medycyny Pracy im. prof. dra Jerzego Nofera w Łodzi
Tematy:
stanowisko pracy
Legionella
aerozole
mikrobiologia
układ oddechowy
badania ankietowe
workplace
aerosols
microbiology
respiratory system
self report
Opis:
Wstęp: Przedmiotem badań była ocena częstości występowania dolegliwości ze strony układu oddechowego osób narażonych na aerozol wodny w zakładach przemysłowych oraz wstępna ocena skażenia mikrobiologicznego powietrza i wody technologicznej. Materiał i metody: Opracowano ankietę, która zawierała pytania ukierunkowane na warunki pracy oraz występowanie objawów zmian w układzie oddechowym, które mogą sugerować zapalenie płuc, w tym legionelozę. Badania ankietowe przeprowadzono w 9 zakładach mechanicznej obróbki szkła, wzięło w nich udział 131 osób. Badania mikrobiologiczne powietrza i wody wykonano w 1 wybranym zakładzie. W próbkach wody oznaczano obecność bakterii z rodzaju Legionella według PN-EN ISO 11731-2:2008 oraz ogólną liczbę mikroorganizmów według PN-EN ISO 6222:2004. Badania ogólnej liczby pleśni i grzybów w powietrzu prowadzono metodą zderzeniową. Wyniki: Występowanie ostrych dolegliwości ze strony układu oddechowego odnotowano u 28,2% osób, a dolegliwości przewlekłe u 29% osób. Najczęściej występującą dolegliwością był długotrwały kaszel, który zgłaszało 16% badanych. Rzadziej zgłaszana była duszność wysiłkowa (12,9%), świszczący oddech (12,2%) oraz ból w klatce piersiowej (10,7%). Stwierdzono zwiększone ryzyko kaszlu oraz zespołu ostrych objawów, które mogą sugerować zapalenie płuc w grupie osób wykonujących pracę w odległości do 20 m od źródła aerozolu wodno-powietrznego, w porównaniu z pozostałymi pracownikami. Badania mikrobiologiczne wody technologicznej wykazały obecność bakterii Legionella pneumophila w liczbie przekraczającej 1000 jtk/100 ml. Jednocześnie odnotowano wysoką liczbę bakterii i grzybów w powietrzu (> 1000 jtk/m³), których źródłem prawdopodobnie była woda technologiczna. Wnioski: Uzyskane dane ankietowe oraz badania pilotażowe skażenia mikrobiologicznego wody i powietrza na stanowiskach pracy wskazują na istnienie realnego zagrożenia zdrowia pracowników narażonych na wdychanie skażonego aerozolu wodnego. Med. Pr. 2013;64(1):47–55
Background: The frequency of respiratory symptoms in workers exposed to water aerosol was evaluated along with the preliminary assessment of microbiological contamination of air and water used in glass processing plants. Material and Methods: A questionnaire survey was conducted in 131 workers from 9 glass processing plants. Questions focused on working conditions, respiratory symptoms and smoking habits. A pilot study of air and water microbiological contamination in one glass processing plant was performed. Water samples were tested for Legionella in accordance with EN ISO 11731-2:2008 and for total colony count according to PN-EN ISO 6222:2004. Air samples were tested for total numbers of molds and mildews. Results: During the year preceding the survey acute respiratory symptoms occurred in 28.2% of participants, while chronic symptoms were reported by 29% of respondents. Increased risks of cough and acute symptoms suggestive of pneumonia were found among the respondents working at a distance up to 20 m from the source of water aerosol compared to other workers (OR = 2.7), with no difference in the frequency of other symptoms. A microbiological analysis of water samples from selected glass plant revealed the presence of L. pneumophila, exceeding 1000 cfu/100 ml. The number of bacteria and fungi detected in air samples (above 1000 cfu/m³) suggested that water aerosol at workplaces can be one of the sources of the air microbial contamination. Conclusions: The questionnaire survey revealed an increased risk of cough and acute symptoms suggestive of pneumonia in the group working at a shortest distance form the source of water aerosol. Med Pr 2013;64(1):47–55
Źródło:
Medycyna Pracy; 2013, 64, 1; 47-55
0465-5893
2353-1339
Pojawia się w:
Medycyna Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Centralne laboratorium ochrony radiologicznej: retrospekcja i współczesność
Central Laboratory for Radiological Protection
Autorzy:
Bielski, M.
Powiązania:
https://bibliotekanauki.pl/articles/214526.pdf
Data publikacji:
2018
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
materiały radioaktywne
organizacja pracy i zarządzania
BHP i ochrona zdrowia
farby radowe
metody analityczne i pomiarowe
radionuklidy naturalne i sztuczne
przyrządy oraz stacje monitoringu radioaktywnych zanieczyszczeń powietrza
wody i gleby
system Bezpieczeństwa Jądrowego i Ochrony Radiologicznej w Polsce
radioactive materials
work organization and management
work safety and health protection
rad Ra-226 painting
analytical and measurement techniques
natural and anthropogenic
radionuclides
devices and stations for monitoring air contamination
water and soil pollutions
Nuclear Safety and Radiation Protection system in Poland
Opis:
Nawiązując do przypadającego w 2017 r. jubileuszu 60-lecia działalności Centralnego Laboratorium Ochrony Radiologicznej (CLOR) w Warszawie w wywiadzie z dr. Pawłem Krajewskim, dyrektorem CLOR, prezentowane są zagadnienia związane z pracą badawczą i operacyjną tej placówki na przestrzeni lat 1957-2017. Omówiono m.in. opracowane i stosowane w CLOR metody pomiarowe, techniki i technologie oraz skonstruowane w CLOR nowe rodzaje aparatury dozymetrycznej i radiometrycznej, na które uzyskano patenty. Przedstawiono także aktywne uczestnictwo pracowników CLOR w naukowych programach i projektach badawczych krajowych i międzynarodowych. Szczególną uwagę zwrócono na zainicjowaną przez CLOR akcję profilaktyczną, będącą ewenementem na skalę światową, a skierowaną na ochronę ludności, w związku z awarią EJ w Czarnobylu (podanie 18,5 mln Polaków jednorazowej dawki jodu stabilnego, o wielkości zależnej od wieku biorcy). W drugiej części tekstu skoncentrowano się na realizacji zadań, jakie należy podjąć w celu dalszego unowocześnienia systemu Bezpieczeństwa Jądrowego i Ochrony Radiologicznej w Polsce (BJiOR), w tym wzmocnienia systemu zaplecza merytorycznego Technical Suport Organization (TSO).
Referring to the 60th anniversary of the establishment of the Central Laboratory for Radiological Protection in Warsaw, the interview with its Director, Paweł Krajewski presents several issues on research and operational activities of CLOR e during the period of 1957-2017. Among other issues, new measurements methods, developed and implemented in CLOR, new kinds of radiometric and dosimetric devices for which the patents have been granted, were touched upon in the interview. Also, the focus was on the active participation CLOR’s staff in science, research and development projects both at national and international levels. In addition to that, particular attention was paid to the most spectacular action undertaken by CLOR in 1986 just after Chernobyl accident, when prophylactic doses of stable iodine were administered to about 18.5 million of Poles in various amounts depending on a recipient’s age. In the second part of the interview the important questions of modernization and strengthening the Polish system of Nuclear Safety and Radiation Protection and problems of Technical Support Organizations were discussed.
Źródło:
Postępy Techniki Jądrowej; 2018, 1; 2-6
0551-6846
Pojawia się w:
Postępy Techniki Jądrowej
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-20 z 20

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies