Wyszukujesz frazę "water boiler" wg kryterium: Wszystkie pola


Wyświetlanie 1-28 z 28
Tytuł:
Air–water heat pump applied as water boiler in singlefamily house, coefficient of performance analysis under the real conditions
Autorzy:
Lisowska-Lis, A.
Leszczyński, R.
Powiązania:
https://bibliotekanauki.pl/articles/93094.pdf
Data publikacji:
2018
Wydawca:
Państwowa Wyższa Szkoła Zawodowa w Tarnowie
Tematy:
heat pump
air-water
coefficient of performance
COP
pompa ciepła
powietrze-woda
współczynnik wydajności
Opis:
The subject of the research was an air-water heat pump, model PCUW 2.5kW from HEWALEX, installed in a single-family house. The pump is only used for heating water. The research was carried out from 25-08-2017 to 18-09-2017 in the village of Zborowice, in Malopolska region, Poland. The data were recorded from the heat pump system: temperature of the lower heat source (external air), temperature of the upper heat source (water temperature in the tank), time of heat pump was calculated during the analysed cycle of work and electrical energy consumption. The Coefficient Of Performance (COP) of the analysed air-water heat pump was determined. The analysis of the results was carried out using the MATLAB and EXCEL statistical tools. The correlation between COP coefficient and external air temperature is strong: 0.67.
Źródło:
Science, Technology and Innovation; 2018, 3, 2; 58-61
2544-9125
Pojawia się w:
Science, Technology and Innovation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ jakości wody kotłowej na eksploatację oraz serwis kotłów wodnych i parowych
Effects of the boiler water quality on the running and maintenance of water and steam boilers
Autorzy:
Ziółkowski, L.
Powiązania:
https://bibliotekanauki.pl/articles/109270.pdf
Data publikacji:
2013
Wydawca:
AXIS MEDIA
Tematy:
woda kotłowa
kamień kotłowy
kocioł wodny
kocioł parowy
boiler water
scaling
water boiler
steam boiler
Opis:
Kamień kotłowy na powierzchni grzewczej jest świetnym izolatorem, jego przewodnictwo cieplne jest 20 razy mniejsze niż stali kotłowej. Nie tylko termin rewizji wewnętrznej, ale też duża ilość osadzonego kamienia powinna być powodem zatrzymania pracy kotła i przeprowadzenia chemicznego czyszczenia.
Limescale on heating surfaces acts as a highly efficient insulator, its thermal conductivity being 20 times lower than that of steel. The boiler should be shut down not only for a standard inspection of the interior surfaces, but also whenever a considerable amount of limescale is observed, which requires chemical cleaning.
Źródło:
Piece Przemysłowe & Kotły; 2013, 9-10; 46-50
2082-9833
Pojawia się w:
Piece Przemysłowe & Kotły
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ob osobennostjakh korrozii dymogarnykh trub vodogrejjnykh kotlov i ikh zashhite
About features of corrosion of fire-tube pipes hot-water boilers and to their defence
Autorzy:
Korokhov, V.
Busarova, N.
Powiązania:
https://bibliotekanauki.pl/articles/78233.pdf
Data publikacji:
2014
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
corrosion
electrochemical corrosion
chemical corrosion
water boiler
steel element
destruction
chemical resistance
construction material
Źródło:
Motrol. Motoryzacja i Energetyka Rolnictwa; 2014, 16, 5
1730-8658
Pojawia się w:
Motrol. Motoryzacja i Energetyka Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Obieg kogeneracyjny w wodnych kotłach ciepłowniczych
Autorzy:
Ostrowski, Piotr
Pronobis, Marek
Świątkowski, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/986605.pdf
Data publikacji:
2019
Wydawca:
Nowa Energia
Tematy:
kocioł ciepłowniczy
kocioł wodny
kogeneracja
energia elektryczna
wytwarzanie energii elektrycznej
ciepło
wytwarzanie ciepła
heating boiler
water boiler
cogeneration
electricity
electricity generation
heat
heat generation
Opis:
Kogeneracja - wspólne wytwarzanie energii elektrycznej i ciepła przynosi oszczędności w zużyciu paliw pierwotnych. W związku z tym przyczynia się do redukcji emisji szkodliwych substancji do atmosfery (CO2), co również oznacza zmniejszenie kosztów zewnętrznych wytwarzania energii i ciepła. Do tej pory cykle kogeneracyjne nie były stosowane w ciepłowniach wyposażonych w kotły wodne (wodno-rurowe lub płomienicowo-płomieniówkowe). W artykule przedstawiono koncepcję innowacyjnego obiegu kogeneracji, który współpracuje z wodnym kotłem ciepłowniczym lub przemysłowym, a instalacja kogeneracji nie zmienia zatwierdzenia parametrów technicznych kotła i nie ogranicza zakresu jego użytkowania. Przedstawiono opracowane obiegi porównawcze w układach h-s i T-s, pasmowy wykres energii Sankey'a oraz wykresy wybranych wskaźników kogeneracji. Ponadto przedstawiono wskaźniki ekonomiczne kogeneracji dla kotłów wodnych.
Źródło:
Nowa Energia; 2019, 1; 21-28
1899-0886
Pojawia się w:
Nowa Energia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Elements of precision agriculture in malting barley cultivation and the use of barley straw for energy purposes
Wykorzystanie elementów rolnictwa precyzyjnego w uprawie jęczmienia browarnego oraz wykorzystanie słomy jęczmiennej na cele energetyczne
Autorzy:
Denisiuk, Wiesław
Powiązania:
https://bibliotekanauki.pl/articles/93487.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
biomass
low temperature tin water boiler
precision agriculture
barley straw
energy value
biomasa
kocioł wodny blaszany niskotemperaturowy
rolnictwo precyzyjne
słoma jęczmienna
wartość energetyczna
Opis:
The paper presents the results of research on the mass and the energy potential of malting barley straw of the "Klas" variety. The research was designated on a 100 ha plantation located in Pojezierze Iławsko-Sztumskie region. Using the Yara N-Sensor processor, precise application of mineral fertilizers according to determined fertilization demand allowed increasing the grain yield by 26% and the straw biomass yield by 74% compared to the control sample. The resulting increase in biomass obtained in the form of straw impacts its possible partial use for energy purposes without negative effects on the environment. The tested energy value of malting barley straw as a function of moisture content allowed a conclusion that between 10 and 25% of water content the energy value drops from 13.1 to 7.4 GJ·t-1 . For an average water content of 15%, this yields an energy potential unit of 23.76 GJ·ha-1 . Following observations of the combustion process, it was concluded that barley straw cannot be used as a source of biomass for the largescale power production since its ash melts at below 800ºC.
W pracy przedstawiono wyniki badań potencjału masy i energii słomy jęczmienia browarnego odmiany ”Klas” wyznaczonego na plantacji 100 ha zlokalizowanej na Pojezierzu Iławsko-Sztumskim. Precyzyjne aplikowanie nawozów mineralnych wg ustalonych potrzeb nawozowych przy pomocy procesora Yara N- Sensor, umożliwiło zwiększenie plonu ziarna o 26% i biomasy słomy o 74% w porównaniu do próby kontrolnej. Uzyskany wzrost pozyskiwanej biomasy w formie słomy wpływa na możliwość jej częściowego wykorzystania energetycznego bez negatywnych skutków dla środowiska. Przeprowadzone badania wartości energetycznej słomy jęczmienia browarnego w funkcji jej wilgotności pozwalają stwierdzić, że w przedziale od 10 do 25 % zawartości wody, wartość energetyczna spada z 13,1 do 7,4 GJ·t-1 co dla średniej zawartości wody 15% daje jednostkowy potencjał energii 23,76 GJ·ha-1 Jak wykazały obserwacje procesu spalania, słoma jęczmienna nie może być stosowana jako źródło biomasy dla sieciowej energetyki, ponieważ występuje zjawisko topienia się popiołu już w temperaturze poniżej 800ºC.
Źródło:
Agricultural Engineering; 2020, 24, 2; 21-27
2083-1587
Pojawia się w:
Agricultural Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efektywność wykorzystania energii pierwotnej do przygotowania ciepłej wody użytkowej w lokalnej kotłowni osiedlowej
PRIMARY ENERGY CONSUMPTION FOR PREPARATION OF HOT WATER IN BOILER ROOM
Autorzy:
Bartnicki, Grzegorz
Chmielewska, Agnieszka
Powiązania:
https://bibliotekanauki.pl/chapters/2231940.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
ciepła woda użytkowa
zmienność zużycia paliwa
efektywność energetyczna
Opis:
W artykule przedstawione zostały wyniki badań zużycia mediów prowadzonych w istniejącym systemie grzewczym, w którym od kilku lat prowadzone są badania dotyczące problematyki efektywności energetycznej systemów grzewczych oraz funkcjonowania współczesnych, lokalnych źródeł ciepła. Na podstawie danych pomiarowych oszacowano udział ciepła na cele przygotowania ciepłej wody użytkowej w mieszkaniach, który jest zdecydowanie większy niż podawany w literaturze. Określono również zmienność zużycia paliwa i ciepłej wody użytkowej w cyklu rocznym i miesięcznym. Na tej podstawie oszacowano ilość zużytego paliwa na cele przygotowania ciepłej wody użytkowej w ciągu roku.
The paper presents the results of the analysis of energy consumption in residential buildings based on an example of a housing estate in Wroclaw. Data were obtained from monthly readings of heatmeters, water metres, and gas consumption of two boilers houses. Based on the measured data was estimated share of heat for domestic hot water purposes and monthly variation of fuel and heat consumption.
Źródło:
Interdyscyplinarne zagadnienia w inżynierii i ochronie środowiska 6; 5-12
9788374938976
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Doświadczenia z projektowania i wdrażania stacji uzdatniania wody kotłowej dla ENERGO-TECH sp. z o.o.
Experience from the design and Implementation of boiler water treatment installation for ENERGO-TECH Co. Ltd.
Autorzy:
Skoczko, I.
Powiązania:
https://bibliotekanauki.pl/articles/1819487.pdf
Data publikacji:
2011
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
woda kotłowa
stacja uzdatniania wody
projektowanie
boiler water
water treatment plant
designing
Opis:
Przedmiotem niniejszej pracy jest podsumowanie rozważań dotyczących doboru optymalnego systemu uzdatniania wody kotłowej dla firmy ENERGO-TECH sp. z o.o., która jest dostawcą ciepła w postaci pary oraz zarządcą stacji uzdatniania wody dla dużej firmy włókienniczej ANDROPOL S.A.W ramach stażu naukowego finansowanego z unijnego projektu Kapitał Ludzki "Wzmocnienie potencjału kadr nauki i biznesu poprzez transfer wiedzy w regionie" w Katedrze Technologii w Inżynierii i Ochronie Środowiska Politechniki Białostockiej podjęto prace nad pro-jektem stacji uzdatniani wody kotłowej dla ENERGO-TECH sp. z o.o., która pozwoliłaby na odpowiednie oczyszczenie wody, a następnie wdrożeniem go w praktyce. Prace przygotowawcze stanowiły szereg analiz wody surowej oraz wody po wstępnym napowietrzeniu. Analizowanymi parametrami były wskaźniki powszechnie stosowane w analizie wody. Przedstawiono je w tabeli 1. Otrzymane wyniki stanowiły średnią z trzech niezależnych pomiarów wykonanych z dostarczonej wody do badań.
The subject of this paper is a summary of considerations for selecting the optimum system for boiler water treatment installation for ENERGO-TECH Co. Ltd., which is a supplier of heat in the form of steam and water treatment plant manager for a large textile company Andropol SA. The water treatment plant functioning up to now was equipped with an open aeration chamber. On its bottom the perforated pipes with bored holes were placed. It was not suitable water treatment for high-pressure boilers. Used technology allowed to decrease turbidity in the water, suspensions, and partly iron and manganese contents. As part of this project and based on previously obtained results of raw water, 3 sand filters and 6 ion-exchange filters filled with a cation bed Purolite 100E were designed for proper preparation of water for boilers. A satisfactory degree of removal of iron, color, turbidity, ammonia nitrogen and oxidability were not obtained as a result of the used processes. Therefore, the following additional processes were considered: coagulation, preoxidation using hydrogen peroxide and sorption, before ion exchange. The effectiveness of these methods was examined in the laboratory. Sorption with activated carbon has proved the most effective of the three selected processes. There is a danger that the purified water in the way described in this study may reveal the corrosion properties, which in future may lead to the destruction of the walls of boilers. The proposed installation should include ion exchangers - anion exchangers, which allow a complete demineralization and deacidification of purified water, to prevent the destruction of the boilers.
Źródło:
Rocznik Ochrona Środowiska; 2011, Tom 13; 1731-1742
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Uzdatnianie wody kotłowej z zastosowaniem fosforanów oraz Kotaminy C
Boiler water treatment using phosphates and the correction agent Kotamina C
Autorzy:
Ignatowicz, K.
Powiązania:
https://bibliotekanauki.pl/articles/236366.pdf
Data publikacji:
2004
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Opis:
Rozwój nowoczesnej energetyki jest nierozłącznie związany z technologią przygotowania wody dodatkowej do kotłów oraz korygowaniem wody w obiegu cieplnym i chłodzącym. Jakość wody decyduje nie tylko o wskaźnikach ekonomicznych produkcji energii, lecz również wpływa w istotnym stopniu na pewność ruchową i trwałość urządzeń cieplnych. Chociaż przez stosowanie jonitowego demineralizowania wody uzyskuje się obecnie bardzo wysoką jakość wody dodatkowej, to jednak nie udało się dotychczas w pełni zapobiec niszczeniu metalowych elementów kotłów i obiegu zasilającego. Ponieważ dotychczas stosowane środki korekcyjne wykazywały również działanie negatywne, dlatego Instytut Ciężkiej Syntezy Organicznej opracował nowy środek korygujący na bazie amin pod nazwą Kotamina C. W pracy uzasadniono celowość stosowania korekcji wody i pary w obiegu wodno-parowym kotłów parowych walczakowych wysokoprężnych w Elektrociepłowni Białystok. Porównano wskaźniki jakości wody i pary uzyskane przy korekcji fosforanowo-hydrazynowej w latach 1996-1997 oraz przy korekcji kotaminowej w latach 2002-2003. Przedstawiono także porównanie składu jakościowego i ilościowego osadów przed i po wprowadzeniu Kotaminy C.
Advances in power engineering are strictly associated with developments in make-up water technology and water correction in the heating and cooling system. Water quality is a decisive factor affecting not only the economics of power generation but the reliability and lifetime of the heating devices as well. Although demineralization by ion exchange yields high-quality make-up water, it is still impossible to fully avoid damage of the metal parts of the boiler and feeding system. As the substances used so far for water correction had exerted an adverse effect on the heating devices, the staff of the Heavy Organic Synthesis Institute developed an amine-based water correction agent called Kotamina C. The study reported on in this paper justifies the need of applying water and steam correction to the high-pressure through-tube boilers operated in the Heat and Power Station of Białystok. The parameters of water and steam quality obtained with phosphate-hydrasine correction in 1996-1997 are compared with those achieved by using Kotamina C as the correction agent in 2002 and 2003. Comparison is also made between the quality and quantity of the sludge before and after implementation of the correction method based on Kotamina C.
Źródło:
Ochrona Środowiska; 2004, R. 26, nr 3, 3; 25-27
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza efektywności modernizacji tradycyjnej instalacji c.w.u. w budynku jednorodzinnym
Analysis of the effectiveness of the modernization of the traditional hot water installation in single-family building
Autorzy:
Nawrot, J.
Powiązania:
https://bibliotekanauki.pl/articles/2065123.pdf
Data publikacji:
2012
Wydawca:
Politechnika Częstochowska
Tematy:
instalacja c.w.u.
kolektory słoneczne
modernizacja instalacji
hot water coal boiler installation
solar collectors
theoretical payback period
modernization of hot water installation
Opis:
W niniejszej pracy przeanalizowano opłacalność modernizacji tradycyjnej instalacji c.w.u. w istniejącym budynku jednorodzinnym poprzez zastosowanie kolek-torów słonecznych. Przedstawiono analizę kosztów instalacji z kolektorem słonecznym oraz określono opłacalność modernizacji istniejącej instalacji c.w.u. poprzez wyznaczenie prostego okresu zwrotu nakładów.
The study presents an analysis of cost reduction by replacing existing hot water coal boiler installation by solar collectors. It discusses both types of installation, operating costs for each, and theoretical payback period after such modernization was been calculated.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2012, 2 (10); 83--89
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zapobieganie osadzaniu kamienia kotłowego w okrętowych kotłach parowych metodą ultradźwiękową
Preventing furring up in marine steam boilers using the ultrasound method
Autorzy:
Adamkiewicz, A.
Valishin, A.
Powiązania:
https://bibliotekanauki.pl/articles/221934.pdf
Data publikacji:
2014
Wydawca:
Akademia Marynarki Wojennej. Wydział Dowodzenia i Operacji Morskich
Tematy:
okrętowy kocioł parowy
uzdatnianie wody kotłowej
kamień kotłowy
zmiękczanie ultradźwiękowe
marine steam engine
boiler water conditioning
ultrasound softening
Opis:
W artykule przedstawiono wyniki badań eksperymentalnych skuteczności uzdatniania/zmiękczania wody kotłowej metodą ultradźwiękową. Następująca w polu ultradźwiękowym koagulacja cząsteczek soli wapnia i magnezu rozpuszczonych w wodzie kotłowej powoduje sedymentację i zatrzymywanie cząstek na filtrze po stronie ssącej pompy wodnej zasilającej kocioł. Zainstalowanie ultradźwiękowego wibratora w skrzyni cieplnej istotnie ogranicza osadzanie się kamienia kotłowego na powierzchniach wymiany ciepła pomocniczego kotła parowego, zmniejszając częstość i zakres okresowego oczyszczania powierzchni wewnętrznych kotła parowego żaglowca „Kruzensztern”.
The article presents the results of experimental investigations on the effectiveness of boiler water conditioning/softening using the ultrasound method. Coagulation of particles of calcium and magnesium salt diluted in boiler water causes sedimentation and arresting of the particles on the filter in the intake part of the water supply pump. Installing an ultrasound vibrator significantly limits the sedimentation of the fur on surfaces of ancillary heat exchange in a steam boiler, reducing the frequency and scope of periodical cleaning of the inside surfaces of the steam engine installed in the sail ship ‘Kruzensztern’.
Źródło:
Zeszyty Naukowe Akademii Marynarki Wojennej; 2014, R. 55 nr 3 (198), 3 (198); 5-20
0860-889X
Pojawia się w:
Zeszyty Naukowe Akademii Marynarki Wojennej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Performance Analysis of Power Boiler Drum Water Level Control Systems
Analiza pracy układów regulacji poziomu wody w walczaku kotła energetycznego
Autorzy:
Pawlak, M.
Powiązania:
https://bibliotekanauki.pl/articles/397604.pdf
Data publikacji:
2016
Wydawca:
ENERGA
Tematy:
control system
steam boiler
power unit
level control
drum
drum model
układ regulacji
kocioł parowy
blok energetyczny
regulacja poziomu
walczak
model walczaka
Opis:
Described in the paper are the structures of water level controls in power boiler drums. A boiler drum’s function is very important for the power unit process, because this is where water separates from steam, which is then superheated and supplied to the turbine. A boiler drum’s dynamic properties as an object of regulation have been listed. The model has been identified on the basis of measurement data from a real object. In the described system the control and measurement devices’ working conditions are difficult due to high temperature and pressure. Incorrect operation of the control system could lead to a major accident. A performance analysis has been presented of three controller level structures, to ensure the system’s stable operation.
Opisano struktury stosowanych regulatorów poziomu wody w walczaku kotła energetycznego. Walczak pełni bardzo odpowiedzialne funkcje w procesie technologicznym bloku energetycznego, ponieważ zachodzi tutaj proces oddzielania wody od pary, która po przegrzaniu jest doprowadzana do turbiny. Przedstawiono właściwości dynamiczne walczaka jako obiektu regulacji. Przeprowadzono identyfikację modelu na podstawie danych pomiarowych z rzeczywistego obiektu. W opisywanym układzie warunki pracy urządzeń regulacyjnych i pomiarowych są trudne ze względu na wysoką temperaturę i ciśnienie. Niepoprawna praca układu regulacji może doprowadzić do poważnej awarii. Zaprezentowano analizę pracy trzech struktur regulatora poziomu w celu zapewnienia stabilnej pracy układu.
Źródło:
Acta Energetica; 2016, 4; 81-89
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optymalizacja parametrów technologicznych filtra z granulowanym złożem polistyrenowym do uzdatniania wody kotłowej (studium przypadku)
Optimization of technological parameters of the filter with granular polystyrene bed for treatment boiler water (case study)
Autorzy:
Trach, Y.
Wichowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/886302.pdf
Data publikacji:
2019
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
woda kotlowa
uzdatnianie wody
filtry wstepnego oczyszczania
parametry filtracji
kinetyka filtracji
efektywnosc filtracji
Źródło:
Scientific Review Engineering and Environmental Sciences; 2019, 28, 3[85]
1732-9353
Pojawia się w:
Scientific Review Engineering and Environmental Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Disturbances of water level indication in the selected smoke- -tube exhaust gas boiler under the real ambient conditions
Autorzy:
Tuński, T.
Powiązania:
https://bibliotekanauki.pl/articles/359957.pdf
Data publikacji:
2013
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
steam production
de-loaded engine
real ambient conditions
Opis:
New ways of the long term operation of low-speed long-stroke marine Diesel engines such as “Slow Steaming” and “Super Slow Steaming” caused disturbances in operation of waste heat recovery systems from main engines exhaust gases. The advancement of the control systems of the water level in smoke-tube exhaust gas boiler created a possibility to change that parameter during operation of the “main engine – exhaust gas boiler” system. It was made use of such a feature to develop a system of readjustment of water level in the smoke-tube boiler to main engine load. However, introduced methods were saddled with simplifications that can bring in additional disturbances in operation of the boiler feed water systems. The bellow paper deals with influence of the ambient condition of the smoke-tube waste heat boiler on the water level indication in the boiler.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2013, 36 (108) z. 2; 182-185
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research on drum water level control of marine auxiliary boiler based on ADRC
Autorzy:
Gan, H.
Lv, B.
Powiązania:
https://bibliotekanauki.pl/articles/258530.pdf
Data publikacji:
2018
Wydawca:
Politechnika Gdańska. Wydział Inżynierii Mechanicznej i Okrętownictwa
Tematy:
ADRC
robustness
adaptability
drum water level
marine auxiliary boiler
Opis:
SThe active disturbance rejection control (ADRC) exhibits strong robustness and adaptability in the presence of strong interference of a large class of uncertain systems. In order to better control the water level of the auxiliary boiler drum, this paper applies the ADRC to improve its control precision, robustness and timeliness. Firstly, the change of drum water level in a large oil tanker auxiliary boiler is analyzed and the dynamic equation is established. After the mathematic changes, the dynamic equation is transformed into a two-order system. Aiming at the characteristics of nonlinear, time-varying and strong disturbance of the boiler water level control system in marine auxiliary boiler, studying the ADRC that includes tracking differentiator (TD), extended state observer (ESO), nonlinear feedback (NLSEF) and disturbance compensation of four parts. The establishment of two kinds of two-order ADRC controller to control the drum level. Through the theoretical analysis and simulation experiment test, and comparing with the cascade control strategy, the experimental results show that the active disturbance rejection controller satisfies the steady state response index of the system, and has good timeliness and accuracy to the control of water level of the drum.
Źródło:
Polish Maritime Research; 2018, S 2; 35-41
1233-2585
Pojawia się w:
Polish Maritime Research
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Self-adaptive whale optimization for the design and modelling of boiler plant
Autorzy:
Savargave, S. B.
Deshpande, A. M.
Powiązania:
https://bibliotekanauki.pl/articles/1839098.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Instytut Badań Systemowych PAN
Tematy:
boiler
whale optimization
neural model
temperature outlet
feed water flow
Opis:
Recently, boiler plants are have been the subject of intensive investigations in the context of energy-saving technologies and management for power saving and reduction of emissions. Modern boiler design offers several benefits with this respect. In the past, improper design of boilers has been the cause of explosions which led to the loss of life and property. Modern designs attempt to avoid such mishaps. This paper presents a novel Self-Adaptive Whale Optimization Algorithm (SAWOA) for improving the learning characteristic of the neural network, the major intention being to model the characteristics of the boiler plant and so to effectively predict the boiler behaviour. The performance analysis of the introduced model has been carried out using the three test cases with consideration of several parameters. In the experimental analysis, the introduced technique is compared with the existing ones, based on such approaches as Neural Model (NM), Firefly (FF-NM), Adaptive Firefly NM (AFF-NM), and Whale Optimization Algorithm-NM (WOANM). In this comparison, the error, i.e. the difference between the actual and the predicted value, was used, and the results revealed that the error is lower for the introduced technique under different experimental scenarios. The experimental results demonstrate that the performance level of SAWOA is by 18% better than those of NM, FF-NM, and AFF-NM, and by 3.74% better than that of WOA-NM. This confirms the quality of performance of the proposed approach regarding boiler plants.
Źródło:
Control and Cybernetics; 2018, 47, 4; 329-356
0324-8569
Pojawia się w:
Control and Cybernetics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ pola magnetycznego na wodę i roztwory wodne
Autorzy:
Szcześ, A.
Chibowski, E.
Hołysz, L.
Powiązania:
https://bibliotekanauki.pl/articles/274175.pdf
Data publikacji:
2012
Wydawca:
Roble
Tematy:
woda
kamień kotłowy
obróbka magnetyczna wody
uzdatnianie wody
water
boiler scale
magnetic water treatment
water treatment
water magnetizer
Źródło:
LAB Laboratoria, Aparatura, Badania; 2012, 17, 1; 32-34
1427-5619
Pojawia się w:
LAB Laboratoria, Aparatura, Badania
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Water level control system for a boiler drum of a power boiler resistant to measuring track damage
Układ regulacji poziomu wody w walczaku kotła energetycznego odporny na uszkodzenia torów pomiarowych
Autorzy:
Pawlak, M.
Powiązania:
https://bibliotekanauki.pl/articles/256422.pdf
Data publikacji:
2016
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
control system
fault tolerance
redundancy
boiler
power unit
boiler drum
diagnostyka
układ regulacji
tolerowanie uszkodzeń
redundancja
rekonfiguracja
kocioł parowy
blok energetyczny
regulacja poziomu
walczak
Opis:
Design and operation methods of automated systems that tolerate measurement track damage are presented. This type of structure for feed water control systems in the drum boilers is described. The study presents a concept of an FTC (Fault Tolerant Control) system in the regulation system of the water level inside a drum. The creation and examination of partial models for the diagnostic system are described. Analytical redundancy has been applied in the presented regulation system. The effects of diagnostics and fault tolerance on the values of reliability and power block operational safety indexes have been determined in the study. Moreover, regulation systems in use are described and backup structures have been developed in order to create a regulation system that would be resistant to fault of the measurement tracks.
Przedstawiono sposób projektowania i działania układów automatyki tolerujących uszkodzenia torów pomiarowych. Opisano układ tego typu dla systemu regulacji zasilania w wodę kotła walczakowego. Praca przedstawia koncepcję systemu FTC (Fault Tolerant Control) w układzie regulacji poziomu wody w walczaku. Opisano sposób tworzenia i badań modeli cząstkowych dla systemu diagnostycznego. W opisywanym układzie regulacji zastosowano redundancję analityczną. W pracy określono wpływ diagnostyki i tolerowania uszkodzeń na wartości wskaźników niezawodności i bezpieczeństwa pracy bloku energetycznego. Opisano także stosowane układy regulacji i opracowano struktury rezerwowe, aby powstał układ regulacji odporny na uszkodzenia torów pomiarowych.
Źródło:
Problemy Eksploatacji; 2016, 2; 135-144
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Issledovanie vodno-khimichekogo rezhima prjamotochnogo parovogo kotla pri podpitke vodojj, proshedshejj elektrokhimicheskuju vodopodgotovku
Research water chemical the mode of the direct-flow boiler at feed by the water which has passed electrochemical water treatment
Autorzy:
Luk'janov, A.
Najjmanov, A.
Antonenko, S.
Powiązania:
https://bibliotekanauki.pl/articles/76846.pdf
Data publikacji:
2013
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Źródło:
Motrol. Motoryzacja i Energetyka Rolnictwa; 2013, 15, 6
1730-8658
Pojawia się w:
Motrol. Motoryzacja i Energetyka Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Improved system of the water level controling in the smoke-tube exhaust gas boiler
Autorzy:
Tuński, T.
Powiązania:
https://bibliotekanauki.pl/articles/360206.pdf
Data publikacji:
2013
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
“Super Slow Steaming”
de-rated engine
steam production
Opis:
There were many changes of ways of operation of low-speed long-stroke marine Diesel engines powering ships introduced last years. Their range of continuous low load operation has been significantly extended. That changes exerted a great influence on operating condition of equipment connected with engines, particularly waste heat boilers. The bellow paper deals with adjustment of water level in smoke – tube exhaust gas boiler depending on real operating condition of the ship powered by the marine slow-speed longstroke Diesel engine operated under the “Super Slow Steaming” program.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2013, 35 (107); 149-153
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The unit cost of hot water preparation
Koszty jednostkowe przygotowania ciepłej wody użytkowej
Autorzy:
Szul, T.
Powiązania:
https://bibliotekanauki.pl/articles/337537.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Maszyn Rolniczych
Tematy:
cost of hot water
solar panels
gas-fired boiler
koszt przygotowania ciepłej wody użytkowej
kolektory słoneczne
gazowy podgrzewacz pojemnościowy
Opis:
On the basis of technical and economic analysis the unit costs of hot water preparation were calculated for single family homes and multiplex houses, assuming the number of people from 2 to 40 at three different options of hot water consumption: 35, 45, 55 dm3/per capita. The comparative analysis used two accumulation systems for hot water preparation, i.e. a set of solar panels and a system using a gas-fired boiler. Conducted calculations have indicated the system using gas-fired boiler as the one, which in view of the assumed 15-year operating period reveals the best economic indicators, i.e. the costs of hot water preparation will be the lowest.
Na podstawie analizy techniczno-ekonomicznej obliczono koszty jednostkowe przygotowania ciepłej wody użytkowej dla domów jednorodzinnych oraz wielorodzinnych, zakładając liczbę osób od 2 do 40 przy trzech wariantach zużycia ciepłej wody: 35, 45, 55 dm3/os. Do analizy porównawczej przyjęto dwa zasobnikowe systemy przygotowania ciepłej wody użytkowej, tj. system solarny oraz wykorzystujący podgrzewacz gazowy. W wyniku przeprowadzonych obliczeń wskazano na system, który w perspektywie założonego 15-letniego okresu eksploatacji cechuje się najlepszymi wskaźnikami ekonomicznymi a więc koszty przygotowania ciepłej wody użytkowej będą najniższe - jest nim system wykorzystujący gazowy podgrzewacz pojemnościowy.
Źródło:
Journal of Research and Applications in Agricultural Engineering; 2013, 58, 2; 158-162
1642-686X
2719-423X
Pojawia się w:
Journal of Research and Applications in Agricultural Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energy performance optimization in a condensing boiler
Autorzy:
Fernández-Cheliz, Diego
Velasco-Gómez, Eloy
Velasco-Gómez, Juan
Tejero-González, Ana
Powiązania:
https://bibliotekanauki.pl/chapters/31233769.pdf
Data publikacji:
2021
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
condensing boiler
Domestic Hot Water
space heating
excess air
energy performance
Opis:
In Europe, primary energy consumption in buildings accounts for up to 25%–40%, depending on the climate conditions. Space heating and Domestic Hot Water (DHW) contribute significantly to this energy consumption. Among the most common sources for heat generation in these appliances is natural gas. Condensing boilers can surpass the 100% energy performance over the lower heating value if the operating conditions enable the water vapor in the exhaust gases to condensate. Consequently, optimizing the operating parameters of condensing boilers is necessary to decrease the fuel consumption without hindering the water heating needs. The present work presents an experimental approach to the operating parameters of a condensing boiler that works with natural gas. The aim is to develop a theoretical model that relates the energy performance to the water temperature, set by the final user, and the excess air set by the maintenance staff.
Źródło:
Innovations – Sustainability – Modernity – Openness. Modernity in engineering; 67-72
9788366391901
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurements of absorbed heat flux and water-side heat transfer coefficient in water wall tubes
Autorzy:
Taler, D.
Taler, J.
Kowal, A.
Powiązania:
https://bibliotekanauki.pl/articles/240076.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
kotło parowe
odwrotne przewodzenie ciepła
strumień ciepła
żużel
heat flux meter
inverse heat conduction problem
slagging
steam boiler
Opis:
The tubular type instrument (flux tube) was developed to identify boundary conditions in water wall tubes of steam boilers. The meter is constructed from a short length of eccentric tube containing four thermocouples on the fire side below the inner and outer surface of the tube. The fifth thermocouple is located at the rear of the tube on the casing side of the water-wall tube. The boundary conditions on the outer and inner surfaces of the water flux-tube are determined based on temperature measurements at the interior locations. Four K-type sheathed thermocouples of 1 mm in diameter, are inserted into holes, which are parallel to the tube axis. The non-linear least squares problem is solved numerically using the Levenberg-Marquardt method. The heat transfer conditions in adjacent boiler tubes have no impact on the temperature distribution in the flux tubes.
Źródło:
Archives of Thermodynamics; 2011, 32, 1; 77-88
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ temperatury wody zasilającej na eksploatację okrętowych kotłów pomocniczych
Feed Water Temperature Influence on Ships Auxiliary Boilers Operation
Autorzy:
Behrendt, C.
Powiązania:
https://bibliotekanauki.pl/articles/360739.pdf
Data publikacji:
2005
Wydawca:
Akademia Morska w Szczecinie. Wydawnictwo AMSz
Tematy:
zanieczyszczenia gazowe i temperatura wody
korozja
wydajność parowa kotłów
badania symulacyjne
OMiUO 2005
gaseous contamination and feed water temperature
corrosion
boiler steam capacity
simulation research
Opis:
W artykule przedstawiono wpływ zanieczyszczeń wody tlenem i dwutlenkiem węgla na procesy korozyjne pomocniczych kotłów okrętowych. Przeanalizowano wpływ temperatury wody zasilającej na proces jej odgazowania i wzrost wydajności parowej kotłów. Zaproponowano system utrzymania stałej, zadanej wartości temperatury w zbiorniku wody zasilającej.
The paper demonstrates the influence of oxygen and carbon dioxide on corrosion processes in ship's auxiliary boilers. The influence of feed water temperature on degassing and on increase of boilers steam output were analysed. A constant feed water temperature system was proposed.
Źródło:
Zeszyty Naukowe Akademii Morskiej w Szczecinie; 2005, 5 (77); 17-25
1733-8670
2392-0378
Pojawia się w:
Zeszyty Naukowe Akademii Morskiej w Szczecinie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmienność poboru paliwa gazowego w lokalnych źródłach ciepła obsługujących grupy budynków mieszkalnych
The natural gas consumption variability in boiler rooms serving groups of residential buildings
Autorzy:
Bartnicki, G.
Nowak, B.
Powiązania:
https://bibliotekanauki.pl/articles/394961.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
nierównomierność zużycia gazu
rozkład dobowy
przygotowanie ciepłej wody użytkowej
kotłownia gazowa
unevenness of the use of gas
daily distribution
preparation of domestic hot water
gas boiler room
Opis:
W bieżącym stuleciu stosowane są dwa najczęściej spotykane sposoby zaopatrzenia w ciepło kompleksów budynków wielolokalowych. Pierwszym z nich jest zasilanie w ciepło systemowe z sieci ciepłowniczej, a drugim – budowa i eksploatacja lokalnych kotłowni gazowych. Wykorzystanie innych nośników ciepła występuje tylko wówczas, gdy nie jest możliwe podłączenie źródła ciepła do sieci gazowej lub sieci ciepłowniczej. Budynki wielolokalowe charakteryzują się daleko idącą specyfiką w wielu obszarach swojego funkcjonowania, w tym także w zakresie zużycia ciepła. W przypadku kotłowni gazowych konsumpcja ciepła bezpośrednio przekłada się na pobór paliwa gazowego. W artykule przedstawiono i scharakteryzowano zużycie paliwa gazowego przez lokalną dwufunkcyjną kotłownię na podstawie pomiarów wykonywanych z dużą częstotliwością odczytu. Wiedza na temat procesu poboru gazu, nawet w przypadku jeżeli dotyczy to niewielkich ilości, w skali zużycia krajowego, może być podstawą dla poprawy przebiegu tego procesu. Dotyczyć może to nie tylko aspektu ekonomicznego, ale również technicznego, a także punktu widzenia bezpieczeństwa energetycznego oraz efektywności energetycznej. Z tego względu wszystkie podmioty związane z dostawą i odbiorem paliwa gazowego dla zespołu budynków wielolokalowych powinny być zainteresowane poszerzeniem wiedzy na temat tego procesu.
In the current century, the two most common ways of supplying heat to groups of multi- family buildings are used. The first is district heating and the second is local gas boilers rooms. The use of other heat carriers only occurs when it is not possible to connect a heat source to a gas or district heating network. Multi- family buildings are specific in many areas of their operation, including heat consumption. In the case of gas boilers rooms, the consumption of heat directly translates into the consumption of gas fuel. The paper presents and characterizes the consumption of gas fuel by a local bifunctional boiler room on the basis of high frequency readings. Knowledge of the gas consumption process, even if it is small in size, on the scale of domestic consumption may be the basis for improving the process. This may not only be related to the economic aspects but also to the technical aspects as well as to energy security and energy efficiency. Therefore, all entities involved in the supply and receipt of gaseous fuel for multi-block buildings should be interested in expanding their knowledge of this process.
Źródło:
Zeszyty Naukowe Instytutu Gospodarki Surowcami Mineralnymi i Energią PAN; 2018, 102; 37-50
2080-0819
Pojawia się w:
Zeszyty Naukowe Instytutu Gospodarki Surowcami Mineralnymi i Energią PAN
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wtrysk balastu wodnego jako metoda zmniejszenia emisji tlenków azotu
Injection of Water Ballast as a Method to Reduce Nitrogen Oxide Emissions
Autorzy:
Szkarowski, A.
Janta-Lipińska, S.
Orłowska, M.
Mamedov, S.
Powiązania:
https://bibliotekanauki.pl/articles/1813913.pdf
Data publikacji:
2017
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
emisja
wtrysk wilgoci
kocioł
tlenki azotu
emissions
injection of humidity
boiler
nitrogen oxides
Opis:
Metoda wtrysku balastu wodnego jest jednym z najbardziej perspektywistycznych rozwiązań naukowo-technicznych. Skierowana jest ona przede wszystkim na zmniejszenie zanieczyszczeń atmosfery szkodliwymi produktami spalania paliwa organicznego. Przeprowadzona analiza pokazuje, że metoda wtrysku charakteryzuje się unikalnymi energo-ekologicznymi i techniczno-ekonomicznymi wskaźnikami spośród innych technologii ochrony atmosfery. Przesłanką do uzasadnienia tej metody jest zjawisko niejednorodności płomienia wzdłuż paleniska zarówno ze względu na jego skład jak i temperaturę. Przy czym różne strefy płomienia w różnym stopniu „odpowiedzialne” są za powstawanie poszczególnych składników. Temperaturowe warunki i koncentracje komponentów reakcji chemicznych w tych strefach wyznaczają intensywność generacji tlenków azotu (NOx) i ich końcowe stężenie w spalinach. Wtrysk wilgoci do dokładnie określonych stref płomienia obniża ich temperaturę będącą głównym czynnikiem przyśpieszającym generację NOx. Ponadto metoda ta pozwala zapewnić zupełne spalanie przy obniżonym stężeniu wolnego tlenu, co również przyczynia się do zdławienia powstawania tlenków azotu. Opracowanie wykonane zostało dla dwóch kotłów PTVM-50 z palnikami DKZ (rys. 1) zainstalowanych w Drugiej Krasnogwadiejskiej kotłowni w Sankt-Petersburgu. Wstępne obliczenia wykazały, że metoda ta zapewnić może zmniejszenie emisji NOx o 25 do 30% przy wtryskiwaniu balastu w ilości do 1% ekwiwalentnej wydajności parowej kotła. Z kolei zmniejszenie nadmiaru powietrza i towarzyszące temu obniżenie strat ciepła spalinowych powinno pozwolić na zwiększenie sprawności kotła brutto o około 1%. Powyższe założenia zrealizowane zostały w trakcie badań. Ponadto opracowana została optymalna konstrukcja głowicy do wtryskiwania wilgoci, która nakręcana była w miejscu głowicy rozpylającej mazut (rys. 3). Wykorzystanie takiego rozwiązania pozwoliło na pomiary emisji NOx w spalinach, które zaprezentowane zostały w pracy (rys. 4 i rys. 5). W trakcie przeprowadzonej analizy uwzględniane zostały trzy poziomy ewentualnego wpływu emisji ze spalinami kotłów na zanieczyszczenie atmosfery.
The water ballast injection method is one of the most prospective scientific and technical solutions. Its chief purpose is to reduce the pollution of air with harmful products of organic fuel combustion. The analysis conducted demonstrates that the injection method is characterized by unique energy efficiency and environmental friendly indices as compared to other air quality protection methods. The phenomenon of the heterogeneity of the flame along the furnace considering both its composition and temperature constitutes the grounds of this method. Various flame areas are “responsible” to a different extent for the occurrence of individual components. The temperature conditions and the concentrations of the components of chemical reactions in these areas determine the intensity of the generation of nitrogen oxides (NOx) and their final concentration in fumes. An injection of humidity into accurately specified flame areas lowers their temperature, which constitutes the main factor that accelerates the generation of NOx. Furthermore, this method guarantees complete combustion with a reduced concentration of free oxygen, which also contributes to a suppressed occurrence of nitrogen oxides. The present study was performed for two PTVM-50 boilers with DKZ burners (Fig. 1) that are installed in the Second Krasnogwadiejski Boiler Plant in Sankt-Petersburg. Preliminary calculations demonstrated that this method may guarantee a reduction of NOx emissions by 30 per cent with a balance injection in a quantity up to 1 per cent of the equivalent steam boiler performance. A reduction of excess air and the accompanying reduction of fume heat loss should permit an increased gross boiler efficiency by ca. 1 per cent. The aforementioned assumptions were realized during the studies. Furthermore, an optimal design was developed of a head for humidity injection, which was installed in the place of a head that sprays mazut (Fig. 3). The use of this solution permitted measurements of NOx emission in fumes, which are presented in the study (Fig. 4 and Fig. 5). In the analysis conducted, three levels were taken into account of the possible impact of the emissions of fumes from boiler on air pollution.
Źródło:
Rocznik Ochrona Środowiska; 2017, Tom 19; 497-510
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of energy costs in a single family house with gas boiler for a heating system and solar collectors in a domestic hot water system
Autorzy:
Wądołowska, Bernadetta
Krawczyk, Dorota Anna
Powiązania:
https://bibliotekanauki.pl/chapters/31015901.pdf
Data publikacji:
2020
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
renewable energy sources
solar collectors
DHW
heating
Opis:
Solar collectors are commonly used in domestic hot water (DHW) systems in different types of buildings. In this paper we conducted the analysis for a single family house located in two countries: Poland (Warsaw) and Spain (Madrid). Various factors like national rules, climatic conditions, investment costs or fuel and electricity prices were taken into consideration. We took into account flat-plate and vacuum pipe collectors to select the best solution. The results show that the use of solar collectors in Poland and Spain is economically justified. Moreover we analyzed heat loses and annual operating costs of the heating installation for both buildings and they were found to be at a similar level, due to high fuel prices in Spain.
Źródło:
Innovations – Sustainability – Modernity – Openness. Energy; 9-17
9788366391291
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Feasibility study of palm oil boiler ash (POBA) as a partial replacement of sand in foamed concrete
Autorzy:
Mohamed Yousuff, Mohamed Khatif Tawaf
Sharipudin, Siti Shahidah
Mohammad, Shahrul Nizam
Roslan, Azmi
Michael, Zeno
Shahrul Azhar, Ilya Izyan
Zainal Abidin, Nurrul Amilin
Powiązania:
https://bibliotekanauki.pl/articles/35547210.pdf
Data publikacji:
2022
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
foamed concrete
compressive strength
water absorption
sand replacement
palm oil boiler ash
POBA
Opis:
A study was conducted to explore the effect of palm oil boiler ash (POBA) on foamed concrete by varying the percentage of POBA over sand quantities (0, 4, 8 and 12%). This paper primarily discusses the water absorption test, uniaxial compressive strength, and dry density findings. It indicates that substituting sand with POBA greatly enhances the strength of foamed concrete. When the quantity of POBA was raised up to 12% throughout all curing times, the compressive strength steadily increased in the range of 4.34–13.50 N·mm–2. Furthermore, the dry density of foamed concrete was shown to be directly related to the fraction of POBA in the mixture. The dry density of foamed concrete increases as the amount of POBA increases. Despite this, water absorption shown that increasing POBA increases water absorption percentage in foamed concrete from 7.4 to 10.4%. This is due to the fact that a composition with a high POBA percentage will generate more pores than a mixture with a low POBA percentage.
Źródło:
Scientific Review Engineering and Environmental Sciences; 2022, 31, 1; 3-13
1732-9353
Pojawia się w:
Scientific Review Engineering and Environmental Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zmniejszenie energochłonności budynku na cele grzewcze oraz energii cieplnej na cele c.w.u. na przykładzie przedszkola samorządowego
The method of the building energy absorption decrease for heating and for warm water preparation on the kindergarten example
Autorzy:
Piotrowska-Woroniak, J.
Powiązania:
https://bibliotekanauki.pl/articles/271080.pdf
Data publikacji:
2010
Wydawca:
Centralny Ośrodek Badawczo-Rozwojowy Aparatury Badawczej i Dydaktycznej, COBRABiD
Tematy:
kotłownie gazowe
kolektory słoneczne
budownictwo
energochłonność
gas fired boiler room
solar panels
buildings
energy adsorption
Opis:
W referacie przedstawiono przyjęte rozwiązanie technologiczne kotłowni gazowej współpracującej z kolektorami słonecznymi. Zaproponowano, również oprócz zmiany sposobu przygotowania c.w.u., sposób przeprowadzenia kompleksowej termomodernizacji bryły budynku przedszkola, która ma na celu zmniejszenie jego energochłonności, a przez to zmniejszenie rocznych kosztów ogrzewania i kosztów podgrzewu ciepłej wody użytkowej ponoszonych przez gminę. Przedstawiono koszt wykonania zaproponowanego przedsięwzięcia termomodernizacyjnego i oszczędności roczne, oraz przykład zastąpienia energii elektrycznej wykorzystywanej do podgrzewu c.w.u. w budynku przedszkola, energią pozyskaną ze źródła niekonwencjonalnego - wykorzystującego promieniowanie słoneczne, tj. przy pomocy kolektorów słonecznych.
The paper shows the accepted technological solution of the gas fired boiler room cooperating with the solar energy collectors. Except of change of the warm water preparation method, the way of the general thermomodernization of the building body is presented, too. The thermomodernization is the way of the building energy absorption decrease and thanks this the decrease of the annual heating and warm water preparation costs, that charge the local commune. The paper also shows the proposed thermomodernization undertaking cost and the annual savings.
Źródło:
Aparatura Badawcza i Dydaktyczna; 2010, 15, 2; 83-89
2392-1765
Pojawia się w:
Aparatura Badawcza i Dydaktyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-28 z 28

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies