Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "wastewater infiltration system" wg kryterium: Wszystkie pola


Wyświetlanie 1-4 z 4
Tytuł:
Microbial communities and relationship with biofilm spatial distributions in subsurface wastewater infiltration systems
Autorzy:
Zhang, L.
Yang, J.
Powiązania:
https://bibliotekanauki.pl/articles/207883.pdf
Data publikacji:
2016
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
water treatment
wastewater infiltration system
DGGE
volatile suspended solids
oczyszczanie ścieków oczyszczanie wody
systemy infiltracji ścieków
lotne zawiesiny
Opis:
A pilot-scale subsurface wastewater infiltration system (SWIS) was designed for the treatment of polluted river water. The components of microbial communities have been identified and characterized and their dependences on some indicators of biofilm formation in the SWIS have been determined. The average efficiencies of COD, TN and removal were 43.3%, 28.8% and 79.6%, respectively. According to the denaturing gradient gel electrophoresis (DGGE) profile, high intensity and uniform bands were generated, indicating an abundant microbial community in each layer of the SWIS. Furthermore, the Shannon index analysis showed high correlation to the spatial distribution of microbial communities as well as the quantity of biofilm in each sample, which were characterized by measuring volatile suspended solids (VSS), phospholipids, proteins and polysaccharides. Sequencing of partial 16S rRNA gene fragments revealed that the composition of the total bacterial communities was dominated by Alphaproteobacteria, Gammaproteobacteria, Deltaproteobacteria, Pseudomonas, Bacillus, Flavobacteriaceae, TM-7, and other uncultured bacteria. These bacteria may contribute to nutrient removal in SWIS. +4 NH –N
Źródło:
Environment Protection Engineering; 2016, 42, 3; 55-69
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of hydraulic loading on biofilm properties in a subsurface wastewater infiltration system
Autorzy:
Zhang, L.
Yang, J.
Powiązania:
https://bibliotekanauki.pl/articles/205392.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
subsurface wastewater infiltration system
biofilms
hydraulic loading
spatial distribution
biofilm properties
Opis:
In this study, a pilot-scale subsurface wastewater infiltration system (SWIS) was deployed to study landscape water treatment. The goal of the study was to investigate the effects of hydraulic loading on pollutant removal and the spatial distribution of biofilm properties in SWIS. Results showed that the efficiencies of chemical oxygen demand (COD), total nitrogen (TN) and total phosphorus (TP) removal degraded as hydraulic loading increased. Furthermore, quantities of the biofilm properties parameter s increased with the hydraulic loading. Polysaccharide and protein levels ranged from 560 to 1110 μg/g filler and 60 to 190 μg/g filler, respectively, at a hydraulic loading of 0.2 m/d. At a hydraulic loading of 0.4 m/d, the quantities of polysaccharide and protein ranged from 1200 to 3300 μg/g filler and 80 to 290 μg/g filler, respectively. Biofilm intensity and biofilm activity per unit weight decreased with the increase in hydraulic loading.
Źródło:
Archives of Environmental Protection; 2016, 42, 4; 70-79
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The efficiency of filtration materials (Polonite® and Leca®) supporting phosphorus removal in on site treatment systems with wastewater infiltration
Autorzy:
Karczmarczyk, A.
Woja, K.
Bliska, P.
Baryła, A.
Bus, A.
Powiązania:
https://bibliotekanauki.pl/articles/101107.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
phosphorus
reactive material
on site wastewater treatment
infiltration system
Opis:
The most of the on site wastewater treatment systems in Poland discharges treated effluent to the soil. The goal of phosphorus (P) reduction from dispersed sources of pollution can be achieved by application of P reactive materials in the construction of wastewater infiltration systems. Two P reactive materials were tested in this study: Polonite® in grains of 2÷6 mm and lightweight aggregate Leca® in grains of 4÷10 mm. Apparent P sorption capacity was assesed on 40.9 mg·g-1 (Polonite®) and 5.1 mg·g-1 (Leca®). Both materials sorbed P-PO4 very fast, after 15 min over 90% of P was removed from solution and wastwater. Wastewater used in this study came from the outlet from the septic tank of on site septic system. P-PO4 solution was prepared from KH2 PO4 and the tap water. In the small column experiment, four collumns (2 filled with Polonite® and 2 filled with Leca®) were fed with wastewater and P-PO4 solution in hydraulic loadings of 30÷40 dm3 ·m-2·d-1. All the columns removed significant amounts of P from both solution and wastewater with the reduction between 28.3% and 72.5%. The mean P-PO4 effluent concentrations ranged from 1.21 mg·dm-3 to 7.12 mg·dm-3. The best overall performance was achieved by the Polonite® fed with solution. Both tested materials can support wastewater treatment in on site systems.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2017, IV/1; 1401-1413
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zasady poprawnego wykonania bilansu ilościowego ścieków dopływających do sieci kanalizacji sanitarnej oraz obiektów kanalizacyjnych na niej wybudowanych
Rules of conducting correct quantitative balance of wastewater flowing into sewage network and the objects built within it
Autorzy:
Ćwiertnia, R.
Ćwiertnia, T.
Powiązania:
https://bibliotekanauki.pl/articles/161340.pdf
Data publikacji:
2018
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
system kanalizacyjny
projektowanie
błąd projektowy
odpowiedzialność
bilans ścieków
natężenie objętościowe przepływu
woda deszczowa
woda gruntowa
infiltracja
sewage system
designing
design fault
responsibility
sewage balance
volume flow rate
rain water
ground water
infiltration
Opis:
Tylko poprawnie wykonany bilans ilościowy ścieków zapewni optymalne działanie sieci kanalizacji sanitarnej oraz obiektów na niej wybudowanych. Projektant i użytkownik ww. sieci kanalizacyjnej dowie się, jakie niezależne ilości obciążają tą sieć kanalizacyjną oraz jak je należy obliczać. Z treści artykułu wynika, jak ważne jest wnikliwe dokonanie analizy czynników wpływających na bilans ilościowy ścieków oraz jaki zakres powinna osiągnąć odpowiedzialność za wykonanie projektu, jego uzgodnienie, wydanie warunków technicznych i jego zaopiniowanie lub uzgodnienie.
Only a properly done quantitative balance of wastewater will ensure the optimal performance a sewage network and the objects built within it. Both designers and users of this sewage network will find out how much independent amount of sewage loads the network and how it should be calculated. The contents of the article clearly demonstrates how important it is to make an in-depth analysis of various factors influencing the quantitative balance and what should be the range of designers’ responsibility for a project, meeting its technical conditions, agreeing them and evaluating.
Źródło:
Przegląd Budowlany; 2018, 89, 7-8; 51-56
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies