Tytuł:
Research and Modeling of Mechanical Crosstalk in Linear Arrays of Ultrasonic Transducers
Autorzy:
Celmer, M.
Opieliński, K.
Powiązania:
https://bibliotekanauki.pl/articles/176916.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
mechanical crosstalk
ultrasonic transducer array
FEM modeling
COMSOL Multiphysics
Opis:
Linear arrays of ultrasonic transducers are commonly used as ultrasonic probes in medical diagnostics for imaging the interior of a human body in vivo. The crosstalk phenomenon occurs during the operation of transducers in which electrical voltages and mechanical vibrations are transmitted to adjacent components. As a result of such additional excitation of the transducers in the array, the directivity characteristics of the aperture used changes, and consequently there is interference with proper operation of a given array and the emergence of distortions in the obtained ultrasound image that reduce its quality. This paper studies the manner of propagation of mechanical crosstalk in the designed model of a linear array of ultrasonic transducers on the basis of unwanted signals, which appeared on elementary piezoelectric transducers when power is supplied to the selected transducer in the array. The universal model of linear array of ultrasonic transducers, which has been developed, allowed the simulation of mechanical crosstalk, taking into account the cross-coupling phenomenon in all of its structure with the use of finite elements method (FEM) implemented in COMSOL Multiphysics software. The analysis of crosstalk signals showed that they consist of aggregated pulses propagating with different speeds and frequencies. This signifies the formation of different vibration modes transmitted simultaneously via different paths. The paper is an original approach which enables to identify different vibration modes and estimate their participation in the crosstalk signal and their ways of propagation. Conclusions from the research allow predicting specific design changes which are significant due to the minimization of mechanical crosstalk in linear arrays of ultrasonic transducers.
Źródło:
Archives of Acoustics; 2016, 41, 3; 599-612
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ultrasonic Mammography with Circular Transducer Array
Autorzy:
Opieliński, K. J.
Pruchnicki, P.
Gudra, T.
Powiązania:
https://bibliotekanauki.pl/articles/177684.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ultrasonic projection imaging
UPI
ultrasonic mammography
circular transducer array
woman’s breast tissue
Opis:
Ultrasonic projection imaging is similar to X-ray radiography. Nowadays, ultrasonic projection methods have been developed in the set-up of multi-element flat arrays with miniature transducers, where one of the array acts as a transmitter and the other one is a receiver. In the paper, a new method of the projection imaging using a 1024-element circular ultrasonic trans- ducer array is presented. It allows the choice of a projection scanning plane for any angle around a studied object submerged in water. Fast acquisition of measurement data is achieved as a result of parallel switch- ing of opposite transmitting and receiving transducers in the circular array and vertical movement of the array. The algorithm equalizing the length of measurement rays and the distances between them was elaborated for the reconstruction of projection images. Projection research results of breast phantom obtained by means of the elaborated measurement set- up and compared with mammography simulations (acquired through overlapping of X-ray tomographic images) show that ultrasonic projection method presented in this paper (so-called ultrasonic mammogra- phy) can be applied to the woman’s breast and be used as a diagnosis for an early detection of cancerous lesions. It can, most of all, be used as an alternative or complementary method to standard mammog- raphy, which is harmful because of ionizing radiation and invasive due to the mechanical compression of tissue.
Źródło:
Archives of Acoustics; 2014, 39, 4; 559-568
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal Effects Induced in Liver Tissues by Pulsed Focused Ultrasonic Beams from Annular Array Transducer
Autorzy:
Kujawska, T.
Secomski, W.
Krawczyk, K.
Nowicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/176937.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
annular array transducer
pulsed focused nonlinear ultrasound
electronically moved focus
tissue heating
biological effects
tissue necrosis
Opis:
Many therapeutic applications of pulsed focused ultrasound are based on heating of detected lesions which may be localized in tissues at different depths under the skin. In order to concentrate the acoustic energy inside tissues at desired depths a new approach using a planar multi-element annular array transducer with an electronically adjusted time-delay of excitation of its elements, was proposed. The 7-elements annular array transducer with 2.4 MHz center operating frequency and 20 mm outer diameter was produced. All its elements (central disc and 6 rings) had the same radiating area. The main purpose of this study was to investigate thermal fields induced in bovine liver in vitro by pulsed focused ultrasonic beams with various acoustic properties and electronically steered focal plane generated from the annular array transducer used. The measurements were performed for the radiating beams with the 20 mm focal depth. In order to maximize nonlinear effects introducing the important local temperature rise, the measurements have been performed in two-layer media comprising of a water layer, whose thickness was specific for the transducer used and equal to 13 mm, and the second layer of a bovine liver with a thickness of 20 mm. The thickness of the water layer was determined numerically as the axial distance where the amplitude of the second harmonics started to increase rapidly. The measurements of the temperature rise versus time were performed using a thermocouple placed inside the liver at the focus of the beam. The temperature rise induced in the bovine liver in vitro by beams with the average acoustic power of 1W, 2Wand 3Wand duty cycle of 1/5, 1/15 and 1/30, respectively, have been measured. For each beam used the exposure time needed for the local tissue heating to the temperature of 43.C (used in therapies based on ultrasonic enhancement of drug delivery or in therapies involving stimulation of immune system by enhancement of the heat shock proteins expression) and to the temperature of 56.C (used in HIFU therapies) was determined. Two sets of measurements were done for each beam considered. First, the thermocouple measurement of the temperature rise was done and next, the real-time monitoring of dynamics of growth of the necrosis area by using ultrasonic imaging technique, while the sample was exposed to the same acoustic beam. It was found that the necrosis area becomes visible in the ultrasonic image only for beams with the average acoustic power of 3 W, although after cutting the sample the thermo ablated area was visible with the naked eye even for the beams with lower acoustic power. The quantitative analysis of the obtained results allowed to determine the exposure time needed to get the necrosis area visible in the ultrasonic image.
Źródło:
Archives of Acoustics; 2011, 36, 4; 937-944
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Model of multipath propagation of ultrasonic pulses in soft tissue using divergent beam tomography method
Autorzy:
Borowski, Jędrzej
Opieliński, Krzysztof J.
Powiązania:
https://bibliotekanauki.pl/articles/127791.pdf
Data publikacji:
2019
Wydawca:
Politechnika Poznańska. Instytut Mechaniki Stosowanej
Tematy:
model of multipath propagation of ultrasonic pulses
ultrasonic transducer ring array
divergent wave beam
soft tissue
ultrasound tomography
model wielościeżkowej propagacji impulsów ultradźwiękowych
pierścieniowa głowica ultradźwiękowa
rozbieżna wiązka fali
tkanka miękka
tomografia ultradźwiękowa
Opis:
The paper presents the model of calculating ultrasound waveform beam emitted inside the circular space of ultrasonic transducer ring array and propagated through a biological medium submerged in water. Each elementary transducer emits a burst signal, which then propagates through a medium and is received by a number of transducers on the opposite side of the ring array. The method allows for calculating runtime and amplitude of ultrasonic bursts while traveling from an emitter to a receiver through a specified soft tissue section geometry, having regard to the refraction and attenuation effects and directivity pattern of transducers. The soft tissue section geometry is constructed using circular shapes with given ultrasound speed and attenuation distribution. The elaborated software creates a set of received waveforms for each transmitting transducer. The presented results produced by the software can be used as a basis for further research on inverse problems in ultrasound waveform tomography.
Źródło:
Vibrations in Physical Systems; 2019, 30, 1; 1-8
0860-6897
Pojawia się w:
Vibrations in Physical Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Annular Array Transducer and Matched Amplifier for Therapeutic Ultrasound
Autorzy:
Secomski, W.
Nowicki, A.
Wójcik, J.
Lewandowski, M.
Walczak, M.
Tymkiewicz, R.
Powiązania:
https://bibliotekanauki.pl/articles/177840.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
ultrasonic therapy
annular array transducer
ultrasonic field
Opis:
The use of therapeutic ultrasound continues to grow. A focused ultrasonic wave can increase the tissue temperature locally for the non-invasive cancer treatment or other medical applications. The authors have designed a seven-element annular array transducer operating at 2.4 MHz. Each element was excited by sine burst supplied by a linear amplifier and FPGA control circuits. The acoustic field, generated by a transducer was initially numerically simulated in a computer and next compared to water tank hydrophone measurements performed at 20, 40 and 60 mm focal depth. The results showed good agreement of the measurements with theory and the possibility to focus the ultrasound in the preselected area. The total acoustic power radiated by the annular array was equal to 2.4 W.
Źródło:
Archives of Acoustics; 2010, 35, 4; 653-660
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A Study of Directional Patterns of Ultrasonic Parametric Array
Autorzy:
Rakov, Denis S.
Rakov, Aleksandr S.
Kudryavtsev, Andrey N.
Krasnenko, Nikolay P.
Chursin, Yury A.
Murin, Maksim A.
Powiązania:
https://bibliotekanauki.pl/articles/176760.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
antenna array
ultrasonic transducer
primary frequency
differential frequency
parametric array
Opis:
The paper presents results of numerical calculations and experimental data on the directional pattern of two 38-element parametric arrays composed of ultrasound sources. Two types of antenna arrays are considered, namely with parallel and coaxial connections of ultrasonic transducers (elements). The results of selecting and functional testing of unit elements are described in this paper. It is found that in the coaxial element connection of the antenna array, the level of side lobes is higher than that in the paralel element connection.
Źródło:
Archives of Acoustics; 2019, 44, 2; 301-307
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies