Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "thermal performance" wg kryterium: Wszystkie pola


Tytuł:
A Study of Computer-Based Task Performance Under Thermal Stress
Autorzy:
Chase, B.
Karwowski, W.
Benedict, M. E.
Quesada, P. M.
Irwin-Chase, H. M.
Powiązania:
https://bibliotekanauki.pl/articles/90836.pdf
Data publikacji:
2003
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
dual task
thermal environment
cognitive performance
środowisko pracy
obciążenie cieplne
aklimatyzacja w wysokiej temperaturze
mikroklimat
Opis:
A visual-visual dual computer task was designed to test the effect of the thermal environment on dual task performance. The temperatures selected for testing were 20 and 35 °C Wet Bulb Globe Temperature (WBGT). 34 volunteers were randomly assigned to 1 of the 2 temperature conditions. Individual differences in single task performance were controlled by equating the baselines of single task performance. Once individual differences in single task capacity were con-trolled, statistically significant differences in performance were demonstrated. Mean Accuracy was computed over a 1-hr testing period in each temperature condition. Participants’ mean accuracy in the 35° condition (38.18%) was substantially lower than in the 20° condition (50.88%).
Źródło:
International Journal of Occupational Safety and Ergonomics; 2003, 9, 1; 5-15
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Działanie podzespołów sterujących układów hydraulicznych w niskich temperaturach otoczenia w warunkach zasilania gorącym czynnikiem roboczym
Performance of hydraulic control systems fed with hot working fluid in low ambient temperatures
Autorzy:
Jasiński, R.
Powiązania:
https://bibliotekanauki.pl/articles/328794.pdf
Data publikacji:
2004
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
napędy hydrostatyczne
elementy sterujące
procesy cieplne
hydrostatic drive
control
thermal processes
Opis:
Podczas eksploatacji układów hydraulicznych w niskich temperaturach otoczenia powstaje cały szereg trudności ich prawidłowego działania. Może wystąpić między innymi przypadek rozruchu wychłodzonych podzespołów sterujących i wykonawczych zasilanych olejem (nawet gorącym) o temperaturze przewyższającej temperaturę podzespołu. Nagły dopływ gorącego oleju do oziębionego podzespołu hydraulicznego (np. rozdzielacza czy silnika) powoduje tzw. "szok termiczny", któremu towarzyszy niejednakowe nagrzewanie się elementów tego podzespołu w czasie, wskutek różnych cech konstrukcyjnych i własności materiałowych. Przebieg temperatury poszczególnych elementów podzespołu hydraulicznego wywołany warunkami szoku termicznego jest różny. Powoduje to różną w czasie rozszerzalność cieplną elementu podzespołu wpływając na wielkość luzów w procesie przejściowym i może wywołać nieprawidłową pracę całego układu hydraulicznego.
Many problems may be encountered when hydraulic systems are operated in low ambient temperatures. Among them there may be a case of starting-up frozen controls and actuators supplied with oil of temperature higher (even hot) than the temperature of a hydraulic element. An abrupt flow of the hot oil into the frozen hydraulic element (eg directional valve or motor) causes so called "thermal shock", which is accompanied by a non-uniform heating of the element's parts caused by different material and structure properties. The thermal shock causes different temperature responses in particular parts of a hydraulic element. Different thermal expansion of those parts influences height of clearances during this transient process and may jeopardize the performance of the whole hydraulic system.
Źródło:
Diagnostyka; 2004, 30, T. 1; 211-216
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal Performance Assessment of Heat Resistant Fabrics Based on a New Thermal Wave Model of Skin Heat Transfer
Autorzy:
Zhu, F.
Zhang, W.
Song, G.
Powiązania:
https://bibliotekanauki.pl/articles/90033.pdf
Data publikacji:
2006
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
thermal performance
skin burn
skin simulant sensor
heat resistant fabrics
thermal wave skin model
ciepło
temperatura skóry
oparzenie
Opis:
A thermal wave skin model incorporating surface heat flux from a skin simulant sensor is developed to characterize the thermal performance of heat resistant fabrics covering the skin simulant sensor. Comparisons of time to 2nd-degree skin burn and temperature elevation of skin beneath a layer of fabric between the Pennes’ equation and the newly developed thermal wave skin model are performed in this research. Results of tolerance time from the Stoll criterion method are also compared with those from 2 skin models in a thermal protective performance calorimeter. It is concluded that the thermal properties of heat resistant fabrics can be characterized more precisely than previously.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2006, 12, 1; 43-51
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ temperatury środowiska zewnętrznego na sprawność działania człowieka
The influence of thermal stress on mans physical performance
Autorzy:
Sudoł-Szopińska, I.
Łuczak, A.
Powiązania:
https://bibliotekanauki.pl/articles/180482.pdf
Data publikacji:
2006
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
stres termiczny
komfort cieplny
thermal stress
thermal comfort
Opis:
Stres termiczny, będący integralnym elementem pracy w wielu sytuacjach życia zawodowego i pozazawodowego, ma istotny wpływ na sprawność i bezpieczeństwo działania człowieka. W artykule przedstawiono procesy fizjologiczne oraz sprawności i funkcje poznawcze, których poziom ulega istotnemu obniżeniu w warunkach stresu termicznego, jak również czynniki indywidualne i środowiskowe mające znaczenie w relacji stres termiczny - sprawność człowieka. Szczególną sytuacją, zwłaszcza w sezonie letnim, narażenia na mikroklimat gorący jest stosowanie kasku ochronnego, np. motocyklowego, który mimo niepodważalnej roli w zakresie ochrony głowy przed urazami mechanicznymi, może mieć niekorzystny wpływ na szereg procesów poznawczych motocyklisty, z uwagi na tworzące się w przestrzeni pod kaskiem gorące środowisko. W artykule omówiono więc także szczególną rolę głowy w procesie wymiany ciepła między człowiekiem i otoczeniem, podkreślając przy tym znaczenie badań nad wpływem różnych elementów odzieży ochronnej, w tym kasków, m.in. systemów ich chłodzenia, na komfort i bezpieczeństwo człowieka w warunkach stresu termicznego.
Thermal stress, an integral element of work in both professional and non-professional life, has a vital influence on man's physical performance and safety. This article presents physiological as well as cognitive functions and capacities, which decrease considerably under thermal stress, as well as individual and physiological factors, which play a significant role in the relationship between thermal stress and human performance. The use of a protective helmet (for instance, a motorcycle helmet) brings about exposure to a hot microclimate, especially in summer. Admittedly, its role in protecting the head against mechanical trauma is unquestionable; nonetheless due to the hot microclimate generated in the space under the motorcyclists helmet, it can have a negative influence on a number of cognitive processes. The article also discusses the special role the head plays in the process of heat exchange between man and the environment. It emphasizes the significance of research on the impact of various elements of protective clothing (including helmets) and, e. g., their cooling systems on comfort and safety of man under thermal stress.
Źródło:
Bezpieczeństwo Pracy : nauka i praktyka; 2006, 7/8; 16-19
0137-7043
Pojawia się w:
Bezpieczeństwo Pracy : nauka i praktyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza własności optycznych izolacji transparentnej i ich wpływ na efektywność energetyczną przegrody
Analysis of optical properties of transparent insulation and impact on thermal performance
Autorzy:
Heim, D.
Puchała, P.
Powiązania:
https://bibliotekanauki.pl/articles/363042.pdf
Data publikacji:
2007
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
izolacje transparentne
przepuszczalność
promieniowanie słoneczne
energooszczędność
transparent insulation
rock permeability
solar radiation
Opis:
W pracy omówiono zagadnienia związane z charakterystykami optycznymi izolacji półprzezroczystej oraz przeprowadzono teoretyczną analizę jej wybranych parametrów. Wykorzystując zaawansowane modele numeryczne przeanali- zowano zestaw teoretycznych charakterystyk optycznych w celu znalezienia najlepszego rozwiązania dla warunków Polskich. Przyjętym kryterium wyboru była charakterystyka energetyczna warstwy izolacji i jej globalny bilans energetyczny, w szczególności zmienne strumienie zysków i strat ciepła przez warstwę materiału transparentnego.
The properties of transparent plaster covering transparent insulation materials (TIM) were investigated using a whole building simulation program (ESP-r). The results of the initial analysis showed the desirable optical properties, estimated for sun incident angles on the fasade at a latitude of 52 degrees north. Then, simulations based on real climatic data for Poland were conducted to predict the thermal TIM wall behaviour. The influence of the structure on the diurnal heat storage potential was investigated for summer and winter.
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2007, T. 2; 97-100
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Termodynamika strukturalnego zasobnika ciepła z pełnym przebiegiem przemiany fazowej złoża PCM w fazach ładowania i rozładowania w cyklu dobowym
Thermodynamics and daily thermal performance of PCM based storage unit
Autorzy:
Dzieniszewski, W.
Wnuk, R.
Powiązania:
https://bibliotekanauki.pl/articles/362984.pdf
Data publikacji:
2007
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
zasobnik (magazyn) i magazynowanie ciepła [4]
energia wewnętrzna zasobnika
materiał fazowo-zmienny
PCM
równania bilansu energii wewnętrznej i temperatury
phase change material
Opis:
Przedstawiono sformułowanie i ogólne rozwiązanie zagadnienia akumulacji i wymiany ciepła pozyskiwanego z promieniowania słonecznego, w płaskim strukturalnym zasobniku z wypełnieniem materiałem fazowo-zmiennym w stałej temperaturze. Wobec zalożenia możliwości istnienia w zasobniku dodatkowych wspomagających konwencjonalnych źródeł ciepła przyjęto, że w czasie jego funkcjonowania zachodzi pełny przebieg procesów przemiany fazowej złoża, zarówno w fazach ładowania i rozładowania energii cieplnej odpowiednio w porach dziennej i nocnej w cyklu dobowym. Sformułowano równania energii wewnętrznej i temperatury magazynu, określono dobowy przebieg jego temperatury i zrównoważone w cyklu dobowym ilości magazynowanego ciepła, pozyskiwa- nego i oddawanego otoczeniu. Przypadek funkcjonowania zasobnika, bez udziału dodatkowych źródeł ciepła, zilustrowano przykladem funkcjonowania zasobnika z wypełnieniem parafiną, RT26.
Integrated to internal wall PCM based storage unit absorbs solar radiation during daytime and releases the heat at night. The features of storage unit and its thermal characteristics are described. The basic conservation equations of energy for the day and night time are presented. Daily thermal performance is obtained from mathematical calculations for selected commercial PCM- RT 26.
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2007, T. 2; 29-34
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Inwentaryzacja rzeczywistych strat ciepła przez przegrody budynków z wykorzystaniem termografii
Assessment of the actual heat loss through building walls by means of thermal imaging
Autorzy:
Kisilewicz, T.
Wróbel, A.
Powiązania:
https://bibliotekanauki.pl/articles/130546.pdf
Data publikacji:
2008
Wydawca:
Stowarzyszenie Geodetów Polskich
Tematy:
termografia
certyfikat energetyczny
budownictwo mieszkaniowe
straty cieplne
przenikanie ciepła
thermography
energy performance certificate
housing industry
heat losses
heat transfer
Opis:
Prawo budowlane nakłada od 1 stycznia 2009 roku obowiązek certyfikacji energetycznej budynków i mieszkań. Certyfikat winien opisywać aktualną efektywność energetyczną budynku. Do ilościowego określenia rzeczywistych własności cieplnych przegród budowlanych można zastosować termografię. Wykorzystanie badań termograficznych jest ograniczone jednak pewnymi warunkami, które muszą być spełnione, aby w wyniku badań można było wyznaczyć prawdziwą wartość izolacyjności cieplnej przegrody. Budynek musi być zamknięty i ogrzewany. Temperatura powietrza na zewnątrz budynku powinna być znacznie niższa od temperatury wewnątrz budynku. Warunki atmosferyczne przed i w czasie pomiaru powinny zapewniać z wystarczającą dokładnością przepływ ciepła zbliżony do ustalonego, a pomiar termograficzny musi być dokonywany od wnętrza budynku. Określenie strat ciepła poprzez przegrody wymaga nie tylko znajomości parametrów cieplnych ściany, ale i wielkości powierzchni odpowiadającej określonej wartości izolacyjności cieplnej. Wykonane termogramy powinny być, zatem zmontowane w jedną mapę rozkładu temperatury na powierzchni badanej przegrody. Do tego celu można wykorzystać stosowane w fotogrametrii programy do przetwarzania rzutowego. W artykule prezentowane są wyniki badań przeprowadzonych z wykorzystaniem kamery TermaCAM firmy FLIR. Na mapach termograficznych badanych ścian widoczne są zarówno mostki cieplne konstrukcyjne jak i spowodowane błędami wykonania. Straty ciepła obliczono jako sumę iloczynów elementarnych powierzchni izotermicznych i przyporządkowanych do nich strumieni ciepła. Stwierdzono, że rzeczywiste straty ciepła przez zewnętrzne ściany budynków są nawet prawie dwukrotnie większe niż wynikałoby to z projektu
According to the new Polish regulations in force as of 1 January 2009, the energy performance certificate will be required on the construction, sale or rent of buildings and dwellings. The certificate should describe the actual energy performance of the building and should provide information regarding, i.a., thermal resistance of the building shell and air exchange. Calculations based only on a building design - if it exists - may lead to unrealistic results due to changes introduced during construction process, a faulty construction or to insulation ageing. Thermography may be used for quantitative investigation of actual thermal features of a building. To assess the real thermal resistance of the wall, a few vital conditions have to be met. The building examined has to be closed and heated. The indoor air temperature should be significantly higher than the temperature outside. Weather conditions before and during the examination should be stable enough to approximate stationary heat flow through the building shell. Thermal inspection must be done inside the building. It is possible To calculate the total heat loss, it is necessary to know both the wall thermal characteristics (surface temperature distribution or heat transfer coefficient) and the wall area. Thermal images have to be set up into a single temperature distribution map. Computer programmes applied in photogrammetry for projective transformation may be used to draw up the temperature distribution maps. The examples of the actual heat loss assessment for walls of different building systems by means of thermal imaging are presented. The analysis was performed with the ThermaCAM S60 camera and FLIR software. Thermal images of the walls examined revealed not only the presence of structural thermal bridges, but also showed defects due to poor workmanship. Total heat losses were calculated as the sum of the products of the elementary isothermal areas and assigned heat flows. It was shown that the real heat losses through the building outer shell may be even two times higher than the values put forth in the designs.
Źródło:
Archiwum Fotogrametrii, Kartografii i Teledetekcji; 2008, 18a; 231-240
2083-2214
2391-9477
Pojawia się w:
Archiwum Fotogrametrii, Kartografii i Teledetekcji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimizing the Performance of Phase-Change Materials in Personal Protective Clothing Systems
Autorzy:
Reinertsen, R. E.
Ferevik, H.
Holbo, K.
Nesbakken, R.
Reitan, J.
Royset, A.
Le Thi, M. S.
Powiązania:
https://bibliotekanauki.pl/articles/90712.pdf
Data publikacji:
2008
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
phase change materials (PCMs)
protective clothing
thermal stress
Opis:
Phase-change materials (PCM) can be used to reduce thermal stress and improve thermal comfort for workers wearing protective clothing. The aim of this study was to investigate the effect of PCM in protective clothing used in simulated work situations. We hypothesized that it would be possible to optimize cooling performance with a design that focuses on careful positioning of PCM, minimizing total insulation and facilitating moisture transport. Thermal stress and thermal comfort were estimated through measurement of body heat production, body temperatures, sweat production, relative humidity in clothing and subjective ratings of thermal comfort, thermal sensitivity and perception of wetness. Experiments were carried out using 2 types of PCM, the crystalline dehydrate of sodium sulphate and microcapsules in fabrics. The results of 1 field and 2 laboratory experimental series were conclusive in that reduced thermal stress and improved thermal comfort were related to the amount and distribution of PCM, reduced sweat production and adequate transport of moisture.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2008, 14, 1; 43-53
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Performance of Firefighters’ Protective Clothing After Heat Exposure
Autorzy:
Rossi, R. M.
Bolli, W.
Stampfli, R.
Powiązania:
https://bibliotekanauki.pl/articles/89696.pdf
Data publikacji:
2008
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
heat protective clothing
thermal ageing
mechanical resistance
heat protection
Opis:
Heat and mechanical protection properties of 6 fabric combinations commonly used in firefighters’ protective clothing were assessed before and after different heat treatment. It was shown that after heat exposure, the values obtained were generally lower than in the original state. The mechanical properties of the materials were more affected by heat than by heat protective properties. In 2 cases, degradation started before a visible change in the material could be observed, which might be potentially dangerous for the end user who will not realize the alteration of the material.
Źródło:
International Journal of Occupational Safety and Ergonomics; 2008, 14, 1; 55-60
1080-3548
Pojawia się w:
International Journal of Occupational Safety and Ergonomics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Factors affected the performance of fire clay refractory bricks
Czynniki wpływające na wytrzymałość cegieł z gliny ogniotrwałej
Autorzy:
Elngar, M. A. G.
Mohamed, F. M.
El-Bohy, S. A. H.
Sharaby, C. M.
Shalabi, M. E. H.
Powiązania:
https://bibliotekanauki.pl/articles/349655.pdf
Data publikacji:
2009
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
wytrzymałość
kruszywo szamotowe
kaolin
szok termiczny
siła kompresji
refractory
grog
thermal shocks
compressive strength
Opis:
In this investigation some factors affected the performance of the fire clay refractory bricks such as size of grog, percentage of water added to the raw material, percentage of grog and temperature of firing were studied. The results showed that if the percentage of grog increased the shrinkage of bricks decreased, as well as density of bricks was increasing the porosity and water absorption also increased. Furthermore, with increasing of the added water to the raw material the porosity of the bricks increased and if water absorption increased, density decreased. The characteristics of raw material by such methods as x-ray and chemical analysis were also examined.
W pracy zbadano niektóre czynniki wpływające na wytrzymałość cegieł z gliny ogniotrwałej, tj. rozmiar kruszywa szamotowego, procent dodanej wody, zawartość procentowa kruszywa szamotowego, czy temperatura wypalania. Wyniki wskazały, że gdy zawartość procentowa kruszywa szamotowego zwiększyła się to kurczliwość cegieł malała. Analogicznie, gdy gęstość cegieł rosła, porowatość i absorpcja wody również rosła. Zwiększając ilość wody dodawanej do surowca, wywoływało się zwiększenie porowatości cegieł, zaś gdy absorpcja wody zwiększała się - gęstość materiału malała. Charakterystyka materiału za pomocą promieni X oraz analizy chemicznej została również przedstawiona.
Źródło:
Górnictwo i Geoinżynieria; 2009, 33, 4; 49-61
1732-6702
Pojawia się w:
Górnictwo i Geoinżynieria
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena izolacyjności cieplnej metalowo-szklanych ścian osłonowych
Assessment of thermal performance of curtain walling
Autorzy:
Zacharski, A.
Firkowicz-Pogorzelska, K.
Powiązania:
https://bibliotekanauki.pl/articles/182970.pdf
Data publikacji:
2009
Wydawca:
Instytut Techniki Budowlanej
Tematy:
ściana osłonowa
ściana metalowo-szklana
ściana słupowo-ryglowa
współczynnik przenikania ciepła
metoda obliczeń
metoda oceny składnikowa
metoda oceny zbiorcza
izolacyjność cieplna
złącze liniowe
norma
curtail wall
thermal transmittance
calculating method
single assessment method
component assessment method
thermal performance
Opis:
Przedstawiono metody obliczania współczynnika przenikania ciepła metalowo-szklanych ścian osłonowych składających się z przezroczystych i/lub nieprzezroczystych paneli włożonych w ramy lub z nimi połączonych. Opisano dwie metody: zbiorczą metodę oceny i składnikową metodę oceny. Podano ograniczenia obu metod oraz wskazówki przydatne przy ich stosowaniu.
The paper deals with the methods for calculating the thermal transmittance of curtain walls consisting of glazed and/or opaque panels fitted in, or connected to, frames. Two methods were described: single assessment method and component assessment method. The limitations of the methods and advices for their application were given.
Źródło:
Prace Instytutu Techniki Budowlanej; 2009, R. 38, nr 3, 3; 3-26
0138-0796
Pojawia się w:
Prace Instytutu Techniki Budowlanej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Obliczenia energetyczne budynków - dyskusja założeń
Thermal performance of buildings - discussion of assumptions
Autorzy:
Panek, A
Rucińska, J
Powiązania:
https://bibliotekanauki.pl/articles/362744.pdf
Data publikacji:
2010
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
zużycie energii
ocena energetyczna
energy use
energy performance of buildings
Opis:
Artykuł zawiera opis metody godzinowej obliczania zapotrzebowania energii do ogrzewania i chłodzenia. Wyniki zapotrzebowania na energię do ogrzewania i chłodzenia siedmiu budynków testowych uzyskane przy jej pomocy porównano z wynikami otrzymanymi z metody bilansowej, programu Audytor OZC oraz TRNSYS.
The paper presents description of the hourly method used for calculation of required energy usage for heating and cooling. The comparison of results of calculation was done with TRNSYS, Audytor OZC, hourly and seasonal method for seven buildings.
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2010, T. 5, nr 4, 4; 35-41
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
System zacieniająco-izolujący - budowa, działanie, opłacalność
Shading/insulation system ? construction, performance, profitability
Autorzy:
Kęskiewicz, P.
Powiązania:
https://bibliotekanauki.pl/articles/402902.pdf
Data publikacji:
2010
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
zużycie energii
bilans cieplny
aktywne zacienienia
termomodernizacja
nowoczesne budownictwo
power consumption
heat balance
modern construction
thermal efficiency improvement
Opis:
W pracy przedstawiono ideę systemu mającego przynosić oszczędności energii, poprzez ograniczanie przenikania ciepła przez przegrody przezroczyste. Oszczędności wynikają z okresowego zwiększenia izolacyjności przegród przezroczystych w okresie zimnym oraz z dodatkowego zacienienia pomieszczeń w okresie ciepłym. Przybliżono budowę i zasady działania systemu. Przedstawiono możliwości oraz różne parametry sterowania. Przedstawione zostały przewidywane korzyści i potencjalne zastosowania wynikające z zastosowania systemu. Wstępna, teoretyczna analiza ekonomiczna została oparta na zmodyfikowanej metodzie obliczania wskaźnika wartości zaktualizowanej netto, tzn. wskaźnika NPV. Uwzględniono zastosowania różnych źródeł i cen energii cieplnej oraz okresu zwrotu inwestycji. Analizę przedstawiono na przykładzie hali magazynowo-produkcyjnej zlokalizowanej w IV strefie klimatycznej. Symulacje przeprowadzono w programie Purmo OZC 4,0.
Presentation of shading/insulation system, which is supposed to reduce losses (gains) of energy through transparent surfaces. Periodic increase of insulation properties of transparent surfaces during winter period (lower heat loss) and additional protection against excessive sun exposure during warm days (lower demand on cooling energy) which will generate savings. Construction possibilities and operating principles and were shows. Ways to control system, as well as benefits and potential uses. Discussion of economic balance including usage of system, deferent sources of heat energy, theoretical money gains, and potential increase in heat energy costs. The economic balance sheet for an example of theoretical storage depot. Simulation performed on popular computer program Purmo OZC version 4,0.
Źródło:
Budownictwo i Inżynieria Środowiska; 2010, 1, 1; 51-56
2081-3279
Pojawia się w:
Budownictwo i Inżynieria Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal compressor of cascade exchange by pressure
Termiczny kompresor do kaskadowej wymiany ciśnienia
Autorzy:
Krajniuk, A.
Powiązania:
https://bibliotekanauki.pl/articles/374103.pdf
Data publikacji:
2010
Wydawca:
Politechnika Śląska. Wydawnictwo Politechniki Śląskiej
Tematy:
kaskadowa wymiana ciśnienia
kompresor termiczny
cykl pracy
temperatura
energooszczędność
wydajność
charakterystyka obciążenia
cascade pressure exchange
thermal compressor
working cycle
temperature
power efficiency
performance
load characteristic
Opis:
A new method of organization of working cycle of device of direct transformation of heat in the located work of compression of air, based on principle of cascade exchange by pressure, is exposed; the results of pre-selection of basic dimensional and structural parameters of thermal compressor of cascade exchange by pressure are adduced; some special features of its working process are considered; main directions of perfection of working cycle of thermal compressors of cascade exchange of pressure are shown.
Źródło:
Transport Problems; 2010, 5, 1; 15-22
1896-0596
2300-861X
Pojawia się w:
Transport Problems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ dotychczasowych termomodernizacji budynków mieszkalnych na oszczędność energii i planowanie programów rewitalizacji na przykładzie jednego z lubelskich osiedli
The effect of current thermomodernization projects on energy performance of multi-family residential buildings and perspectives for new regeneration projects: the case of a housing estate in Lublin
Autorzy:
Ostańska, A.
Powiązania:
https://bibliotekanauki.pl/articles/390540.pdf
Data publikacji:
2010
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
termomodernizacja
energooszczędność
rewitalizacja
thermal modernisation of buildings
energy saving
urban regeneration
Opis:
Zarządcy wielkich prefabrykowanych osiedli mieszkaniowych powstałych w latach 1970, ze względu na sam rozmiar tych zasobów i ich daleki od doskonałości stan techniczny, są szczególnie zainteresowani poszukiwaniem rozwiązań pozwalających na zmniejszenie zużycia energii. Zakrojone na dużą skalę przedsięwzięcia termomodernizacyjne mogą stać się przyczynkiem do potraktowania problemu tych stosunkowo nowych zasobów w sposób całościowy i traktowanie ich jako punktu wyjścia przedsięwzięć rewitalizacyjnych. W artykule opisano politykę publiczną wobec termomodernizacji w Polsce oraz pilotażowe badania ITB – próby określenia optymalnego zakresu działań termomodernizacyjnych w budynkach wielkopłytowych. Opisano również dotychczasowe działania termomodernizacyjne w skali jednego z lubelskich osiedli i określono kierunek dalszych działań służących oszczędności energii w budownictwie.
Managers of large housing estates whose stocks consist mainly of precast concrete plate buildings of 1970ies, due to their sheer size and technical condition far from being perfect, are especially concerned with searching for solutions that would reduce energy consumption. Thermal modernization projects provide an opportunity to adopt a holistic approach to the problem of obsolescence of this relatively new housing stock and to consider it in terms of urban regeneration. The paper describes the energy saving policies in Poland and results of pilot studies of Building Research Institute (ITB) aimed at defining optimal scope of thermomodernization of precast concrete plate housing. The paper investigates into the effects of thermomodernization of a particular, though typical, housing estate in Lublin in order to give grounds for future actions in the field of energy saving measures.
Źródło:
Budownictwo i Architektura; 2010, 7, 2; 89-103
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies