Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "stone dust" wg kryterium: Wszystkie pola


Wyświetlanie 1-5 z 5
Tytuł:
Stone dust agglomeration for utilizing as building material
Autorzy:
Borowski, G.
Świderski, T.
Ozga, M.
Powiązania:
https://bibliotekanauki.pl/articles/102858.pdf
Data publikacji:
2017
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
agglomeration
stone dust
amphibolite
utilization
Opis:
In the paper we discuss the possibility of using stone dust for utilizing as building material. The tested material was amphibolite, found in the Sudeten Mountains and the Tatra Mountains in Poland. The chemical composition of dust was determined by means of spectrometry methods. Moreover, the basic physical properties of the material were designated. Stone dust was mixed with starch or cement binder. The binder addition was from 5% to 20% by weight. The water content was adjusted to about 25% humidity. The mixture was then compressed in a hydraulic press at 50 MPa. The results of the mechanical toughness of agglomerates were shown. On the basis of the results, acceptable toughness of agglomerates was found, with the addition of cement in mass share 20% and seasoning for 48 hours. However, starch was not suitable as a binder for agglomeration of amphibolite.
Źródło:
Advances in Science and Technology. Research Journal; 2017, 11, 4; 168-174
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena jakości pyłów w kruszywie. badanie wskaźnika piaskowego
Estimation of stone dust quality upon sand equivalent test
Autorzy:
Siemieniuk, M.
Zięba, M.
Powiązania:
https://bibliotekanauki.pl/articles/89052.pdf
Data publikacji:
2014
Wydawca:
Politechnika Wrocławska. Wydział Geoinżynierii, Górnictwa i Geologii. Instytut Górnictwa
Tematy:
wskaźnik piaskowy
ocena jakości pyłów
mieszanki niezwiązane
kruszywa stabilizowane mechanicznie
Opis:
Producenci kruszyw do podbudów niezwiązanych mają trudności z wyprodukowaniem materiału spełniającego wymagania odnośnie wskaźnika piaskowego. Nie ma znaczenia czy badanie wykonywane jest według wycofanej normy BN-64/8931-01, ale nadal obecnej w licznych specyfikacjach, czy też aktualnego wydania normy europejskiej PN-EN 933-8. W 2012 roku opublikowano nowe wydanie normy do badania wskaźnika piaskowego, w której wprowadzono inny sposób przygotowania próbek dla frakcji 0-2 mm niż w wydaniu z 2001 roku. Głównym celem wykonywanych badań było porównanie wyników uzyskanych dla kruszyw badanych na różnych frakcjach (0-2 mm i 0-4 mm), przy wykorzystaniu roztworów zgodnych z polską i europejską normą oraz przy uwzględnieniu nowego sposobu przygotowania próbki, według ostatniej nowelizacji tej normy.
The main aim of project was correlation between different methods used for estimation of stone dust quality in unbound aggregate mixtures for road sub bases. The program builds on the six unbound mixtures 0-31,5 (basalt, dolomite, gabbro, granite, melaphyre and limestone). Sand equivalent test was executed on the fractions 0-2 mm and 0-4 mm after five times crumbling in Proctor apparatus. The solution for sand equivalent test will be prepared according to Polish and European standards (reagents used for preparation of concentrated solution are the same in both cases, but there are different proportions). On this basis it can be concluded if both test (according to PN and PN-EN) give similar results. In many of the technical specifications, the sand equivalent test is still required according to old Polish standard, which has been replaced by PN-EN. In PN-EN 933-8:2012 there is another method of preparation of the sample than in 2001 edition.
Źródło:
Mining Science; 2014, 21, Special Issue 1; 181-189
2300-9586
2353-5423
Pojawia się w:
Mining Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Skuteczność zapór przeciwwybuchowych zbudowanych z pojemników typu zamkniętego
Efficiency of bagged water and stone dust barriers against coal dust explosion propagation
Autorzy:
Lebecki, K.
Cybulski, K.
Dyduch, Z.
Słotwiński, R.
Powiązania:
https://bibliotekanauki.pl/articles/340713.pdf
Data publikacji:
2002
Wydawca:
Główny Instytut Górnictwa
Tematy:
kopalnia
zapory przeciwwybuchowe
zapora wodna
zapora pyłowa
mine
explosion barrier
water barrier
dust barrier
Opis:
Stosowanie zapór wodnych jest w polskich kopalniach ograniczone do wyrobisk mokrych, gdzie bardziej prawdopodobny jest silny wybuch pyłu węglowego. Zapory wodne stanowią około 20% ogółu zapór przeciwwybuchowych. Są one zbudowane z pojemników w kształcie koryt, o objętości 40 litrów. Wymagana ilość wody wynosi 200 lub 400 kg na jeden metr kwadratowy przekroju poprzecznego wyrobiska w pokładach niemetanowych i metanowych odpowiednio. Oznacza to, że na przykład w wyrobisku o przekroju 15 m2 zapora musi zawierać co najmniej 75 pojemników. Wadą pojemników w kształcie koryt jest ich trudny transport i kruchość, powodujące znaczne straty. W ostatnich kilku latach niemiecka firma Chemisch-Technische Fabrikation dr Klaus Schulte zaprezentowała nowe rozwiązanie pojemników. Są to pojemniki zamknięte w postaci worków o objętości 40 lub 80 litrów, wykonane z folii polietylenowej o grubości 80 lub 110 mikrometrów, niepalnej i antystatycznej. Pojemniki owinięte wokół metalowego pręta nośnego, napełnione wodą zawieszone w przekroju wyrobiska zgodnie z obowiązującymi przepisami stanowią zaporę wodną (rys. 1). Pojemniki te zostały dopuszczone do użytku w górnictwie pod pewnymi warunkami. Celem przedstawionej pracy było zbadanie zachowania się i skuteczności zapór zbudowanych z pojemników zamkniętych w warunkach wybuchów o różnej sile, czyli określenie możliwości rozszerzenia zakresu stosowania zapór zbudowanych z pojemników typu zamkniętego. Badania wykonano w podziemnym chodniku doświadczalnym; zapora zawierająca 160 kg wody na jeden metr kwadratowy przekroju wyrobiska była umieszczona w odległości 70-100 m od źródła zapłonu pyłu, w środku strefy pyłowej zawierającej nominalnie 0,2 kg pyłu na metr sześcienny wyrobiska. Inicjałem wybuchu pyłu był pierwotny wybuch 25 lub 50 m3 stechiometrycznej mieszaniny metanowo-powietrznej. Przebieg wybuchu był rejestrowany przez czujniki płomienia i ciśnienia (rys. 2); uruchomienie zapory było oceniane prze pomiar czasu rozerwania pojemnika (rys. 3). Wyniki badań są następujące: - potwierdza się skuteczność zapory z pojemników zamkniętych w hamowaniu wybuchów silnych, o prędkościach płomienia powyżej 200 m/s (doświadczenia CH2514 i CH2518), - skuteczność ta nie jest dostateczna w przypadku hamowania wybuchów słabych; nie ma podstaw do wystąpienia o rozszerzenie dopuszczenia do stosowania tych zapór, - bardzo istotny jest kierunek nawinięcia worka na pręcie nośnym; rozpraszanie wody jest lepsze w przypadku, gdy nawinięcie jest przeciwne do kierunku fali ciśnienia wybuchu. Przebiegi wybuchów są przedstawione graficznie w postaci funkcji droga - czas. Rejestruje się ciśnienie statyczne, położenie płomienia, czas rozerwania pojemnika (czarny kwadrat na wykresie). Wykonano również badania z pojemnikami napełnionymi pyłem kamiennym, stosując eksperymentalne pojemniki trójkomorowe mieszczące około 30 kg pyłu. Pył wapienny umieszczony w workach jest chroniony przed wilgocią. Doświadczenia wykazały, że pył wapienny jest dobrze rozpraszany przez silny wybuch metanu (rys. 4 i 5). W słabym wybuchu, z ciśnieniem statycznym poniżej 0,5 bara rozpraszanie pyłu jest gorsze. W trzech doświadczeniach nie osiągnięto pozytywnych wyników w gaszeniu wybuchu. Stwierdzono również, że napełnianie pojemników jest kłopotliwe. Istotnym wynikiem projektu jest sonda pomiarowa typu SnobGreg do pomiaru ciśnienia statycznego, dynamicznego i temperatury w strumieniu silnie zapylonego powietrza. Przykładowy wynik pomiaru jest pokazany na wykresie CH2521, a sonda zamontowana w chodniku jest pokazana na rysunku 9. Autorzy wyrażają podziękowanie Komitetowi Badań Naukowych za finansowanie prezentowanej pracy.
The use of water barriers is limited to wet workings, where strong explosion is more likely. In Polish coal mines water barriers constitute about 20% of total number of anti explosion barriers. The barriers are commonly built of containers in form of troughs, with volume of 40 litres. The amount of water should be 200 kg or 400 kg per square meter of working cross section in non gassy and gassy mine respectively. It means that in the cross section of 15 m2 at least 75 containers are needed. Disadvantage of the troughs is their difficult transportation and fragility causing considerable loss. In last several years the new solution presented by German company Chemisch-Technische Fabrikation dr Klaus Schulte appeared. The containers are in form of plastic bags (named also the closed containers), with volume or 40 or 80 litres, made of polyethylene foil, 80 or 110 micrometers thick, non flammable and antistacisized. The bags are simply rolled up around the rod, filled with water and hanged in the mine gallery (Fig. 1). The bags are approved for use in coal mines on certain conditions. The objective of the presented work was to investigate the possibility of weak coal dust explosion suppression that means a broader use of bagged barriers. The tests of explosion suppression were performed in underground gallery ; the barrier with about 160 kg of water per sqm of cross section was located inside of dusty zone (nominal dust concentration 0,2 kg/m3) at distance of 70 or 100m. from ignition point at the closed end of the gallery. The primary explosion of 25 or 50 m3 of stoichiometric methane - air mixture initiated the coal dust explosion. The course of explosion was monitored by flame and pressure sensors (Fig. 2); the action of barriers was estimated by a measuring the time of the bag bursting (Fig. 3). The results of tests were as follows: - efficiency of bagged water barrier is confirmed in case of suppression of strong explosions, with average flame speed about 200m/s (experiments CH2514 and CH2518), - efficiency is insufficient in case of weak explosions; there is no reason to broader approval of bagged water barrier, - the direction of rolling the bags up is very essential; the water dispersion is better in case of rolling up in opposite to the direction of pressure wave flow. Course of explosions is presented graphically as time - distance function. There are recorded: static pressures, flame position, container bursting time (black square). The tests with stone dust bags were also performed, using the experimental bags containing about 30 kg of limestone dust in three chambers. Stone dust placed in the bag is protected against moisture. The experiments proved that stone dust is well dispersed by the pressure wave of strong methane explosion (Fig. 4 and 5). In weak explosion with static pressure below of 0,5 bars the dispersion is worth. In three experiments no positive results were achieved. Also the filling of bags is troublesome. The essential result of the project is the probe of SnobGreg type for measurement of static and dynamic pressures, temperatures in strongly dusted air flow. The results of measurements are shown on figure CH2521 and the probe mounted in gallery on Fig. 9.
Źródło:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa; 2002, 1; 67-90
1643-7608
Pojawia się w:
Prace Naukowe GIG. Górnictwo i Środowisko / Główny Instytut Górnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effective use of construction and demolition waste and stone dust in construction for the production of manufactured aggregates in two pilot regions of the Czech Republic
Autorzy:
Vachuska, Vaclav
Vachuska, Jan
Volosinova, Dagmar
Vachuska, Ales
Powiązania:
https://bibliotekanauki.pl/articles/2086911.pdf
Data publikacji:
2022
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
construction waste
stone dust
mineral dust
demolition waste
waste recovery
odpady budowlane
pył kamienny
pył mineralny
odpady rozbiórkowe
odzysk odpadów
Opis:
The authors present a unique possibility of utilizing hitherto unused and difficult-to-store types of waste such as dust generated during the extraction and treatment of a natural stone, and still difficult to recycle part of construction and demolition waste ??? residual mineral inert material. Stone dust mixed with residual mineral inert material, water, and binders in various proportions formed five types of mixtures which were transformed into manufactured aggregates using hyper-pressing. The properties of these manufactured aggregates ??? resistance to crushing and bulk density ??? presented on laboratory--basedsamples were similar to those of natural aggregates. The production of manufactured aggregates, the processing of unused types of construction and demolition waste, together with stone dust, fully comply with the rules of circular economics. The availability of stone dust has been checked based on data obtained by personally interviewing the authors in the quarries of the pilot regions of South Bohemia and Pilsen. Data on the amount of construction and demolition waste produced were obtained from the publicly available database of produced construction and demolition waste ??? Waste Management Information System (ISOH).
Źródło:
Environment Protection Engineering; 2022, 48, 2; 87--95
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optical reflectometric sensor of lime stone concentration in dust residing in coal mines excavations
Optyczny reflektometryczny czujnik zawartości kamienia wapiennego w pyle zgromadzonym w wyrobiskach kopalń węgla kamiennego
Autorzy:
Sidor, T.
Lebecki, K.
Hadryś, D.
Nowak, P.
Trzcionka, S.
Powiązania:
https://bibliotekanauki.pl/articles/370886.pdf
Data publikacji:
2014
Wydawca:
Wyższa Szkoła Zarządzania Ochroną Pracy w Katowicach
Tematy:
coal mines
coal dust
stone dust
reflectometric sensor
kopalnie węgla kamiennego
pył węglowy
pył kamienny
przetwornik reflektometryczny
Opis:
For safety reason it is required to check periodically concentration of non- flammable components in dust deposited in coal mines entries . The traditional procedurę requires the dust samples to be collected in locations determined by safety regulations and transport them to the surface where the concentration of non- flammable components can be evaluated in the laboratory. It would greatly simplified the required procedurę if the dust samples could be tested directly on site . Attempts to construct the suitable equipment, based on measurements of relative intensity of light reflected from dust sample, although almost completed, finally has been abandoned because the manufacturer of reflectometric sensors ceased its production. The following paper presents results of research project which goals was to develop probe, based on commonly available components, which could substitute, the initial sensor choice and further to make possible to complete finally the measuring device. It seems that the initial goal of the project has been successfully achieved.
Ze względów bezpieczeństwa wymagane jest okresowe sprawdzanie stężenia niepalnych składników w pyle znajdującym się w wyrobiskach kopalń. Tradycyjna procedura badawcza wymaga pobrania próbek pyłu w miejscach określonych przez przepisy bezpieczeństwa i przetransportowania ich na powierzchnię, gdzie stężenie niepalnych składników może być oceniane w laboratorium. Znacznym uproszczeniem wymaganej procedury byłoby badanie próbek pyłu bezpośrednio na miejscu w wyrobisku. Prowadzone były próby skonstruowania odpowiedniego sprzętu badającego względne natężenia światła odbitego od próbki pyłu.Jednak pomimo prawie zakończonych badań pomysł ten został porzucony z uwagi na fakt, iż producent czujników reflektometrycznych zaprzestał ich produkcji. W pracy przedstawiono wyniki badań, których celem było opracowanie sondy, w oparciu o powszechnie dostępne elementy. Mogą one zastąpić pierwotnie wybrany przetwornik reflektometryczny i umożliwić zakończenie budowy urządzenia pomiarowego. Wydaje się, że początkowy cel projektu został skutecznie osiągnięty.
Źródło:
Zeszyty Naukowe Wyższej Szkoły Zarządzania Ochroną Pracy w Katowicach; 2014, 1(10); 24-31
1895-3794
2300-0376
Pojawia się w:
Zeszyty Naukowe Wyższej Szkoły Zarządzania Ochroną Pracy w Katowicach
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies